Your browser doesn't support javascript.
loading
Percutaneous treatment of type C distal radius fractures using dual-external fixator.
Yu, Xiaofei; Zhang, Xu; Li, Nan; Yu, Yadong; Yang, Xiaoliang.
Afiliação
  • Yu X; Department of Hand Surgery, Third Hospital of Heibei Medical University, Shijiazhuang, Hebei, 050051, China. Electronic address: yuxiaofei66@126.com.
  • Zhang X; Department of Hand Surgery, Third Hospital of Heibei Medical University, Shijiazhuang, Hebei, 050051, China. Electronic address: ahand@sina.com.
  • Li N; Department of Neuromuscular Diseases, Third Hospital of Heibei Medical University, Shijiazhuang, Hebei, 050051, China. Electronic address: 273960661@qq.com.
  • Yu Y; Department of Hand Surgery, Third Hospital of Heibei Medical University, Shijiazhuang, Hebei, 050051, China. Electronic address: 13313010289@163.com.
  • Yang X; Department of Hand Surgery, Third Hospital of Heibei Medical University, Shijiazhuang, Hebei, 050051, China. Electronic address: 13930156286@163.com.
J Orthop Sci ; 2024 Jul 24.
Article em En | MEDLINE | ID: mdl-39054230
ABSTRACT

BACKGROUND:

This study aimed to introduce a potential alternative percutaneous treatment for AO types C1, C2, and C3 distal radius fractures using dual-external fixator (a no-bridging cemented-pin frame and a conventional wrist-bridging external fixator). MATERIALS AND

METHODS:

From January 2018 to January 2021, 52 patients (52 distal radius fractures) were treated with dual-external fixator. For comparison, 61 patients (61 distal radius fractures) were treated with a plate and screw system. Wrist function was assessed using the Mayo Wrist Score. Patient satisfaction was assessed using the Short Assessment of Patient Satisfaction. A P < 0.05 was considered statistically significant.

RESULTS:

Fracture healing was achieved in all patients. At the final follow-up of 29 months (range, 24-34 months) vs 36 months (range, 26-39 months) (P > 0.05), the patients treated with dual-external fixator and a plate and screw system achieved mean ulnar deviations of 31° vs 29° (P < 0.05), mean Mayo Wrist Scores of 91.12 ± 5.98 vs 88.12 ± 7.54 (P < 0.05), and mean patient satisfaction scores of 23.42 ± 2.47 vs 23.04 ± 2.32 (P > 0.05).

CONCLUSIONS:

AO types C1, C2, and C3 distal radius fractures can be treated successfully using dual-external fixator. The technique is a potential alternative in addition to the conventional treatments. LEVEL OF EVIDENCE Level IIa.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article