Your browser doesn't support javascript.
loading
How green is my reusable bronchoscope?
Massart, Nicolas; Millet, Christophe; Beloeil, Hélène; Fillatre, Pierre; Rouxel, Caroline; Daudin, Magalie; Coullier, Nicolas; Marie, Véronique; Peguet, Elodie; Bardoult, Pierre.
Afiliação
  • Massart N; Service de Réanimation, CH de St BRIEUC, 10, rue Marcel Proust 22000 Saint-Brieuc, France. Electronic address: nicolasmassart@hotmail.fr.
  • Millet C; Service de Réanimation, CH de St BRIEUC, 10, rue Marcel Proust 22000 Saint-Brieuc, France.
  • Beloeil H; Univ Rennes, CHU Rennes, Inserm, COSS 1242, Anesthesia and Intensive Care Department, F-35000 Rennes, France.
  • Fillatre P; Service de Réanimation, CH de St BRIEUC, 10, rue Marcel Proust 22000 Saint-Brieuc, France.
  • Rouxel C; Service d'Urgence, CH de St BRIEUC, 10, rue marcel Proust 22000 Saint-Brieuc, France.
  • Daudin M; Service de Cardiologie, CH de St BRIEUC, 10, rue marcel Proust 22000 Saint-Brieuc, France.
  • Coullier N; Service d'Anesthésie, CH de St BRIEUC,10, rue marcel Proust 22000 Saint-Brieuc, France.
  • Marie V; Service d'hygiène Hospitalière, CH de St BRIEUC,10, rue marcel Proust 22000 Saint-Brieuc, France.
  • Peguet E; Service de Pharmacie, CH de St BRIEUC, 10, rue marcel Proust 22000 Saint-Brieuc, France.
  • Bardoult P; Service de Réanimation, CH de St BRIEUC, 10, rue Marcel Proust 22000 Saint-Brieuc, France; Univ Rennes, CHU Rennes, Inserm, COSS 1242, Anesthesia and Intensive Care Department, F-35000 Rennes, France.
Anaesth Crit Care Pain Med ; : 101420, 2024 Jul 30.
Article em En | MEDLINE | ID: mdl-39089450
ABSTRACT

INTRODUCTION:

Single-use bronchoscopes have replaced reusable ones in many institutions. This study aimed to evaluate the environmental and financial impacts of both strategies reusable and single-use bronchoscopes. MATERIAL AND

METHODS:

We conducted a pragmatic study in a 21-bed polyvalent ICU, in Saint-Brieuc, Bretagne, France. The eco-audit consisted of estimating greenhouse gas (GHG) emissions, considering the life cycle of each strategy. Greenhouse gas (GHG) emissions related to construction, packaging, transport and waste elimination were compared between 2 devices the reusable bronchoscope, a Pentax® FI-16RBS that was disinfected twice daily; and the single-use bronchoscope, the bronchoflex agile® from TSC.

RESULTS:

For the reusable bronchoscope, GHG emissions were marginally impacted by the number of bronchoscopies performed (from 185 kg eq.CO2 per year to 192 kg eq.CO2 for 10 or 110 bronchoscopies per year). For the reusable device, GHG emissions directly depended on the number of bronchoscopies performed with 3.82 kg eq.CO2 emitted per bronchoscopy. The breakeven point for the reusable bronchoscope was estimated at 50 bronchoscopies in terms of GHG emissions and 96 bronchoscopies for financial considerations.

CONCLUSION:

Considering current practice in our ICU, reusable bronchoscopes have lower GHG emissions when used more than 50 times a year and a lower cost when used more than 96 times a year as compared with single-use bronchoscopes.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article