Your browser doesn't support javascript.
loading
Disposable electrochemical sensors based on reduced graphene oxide/polyaniline/poly(alizarin red S)-modified integrated carbon electrodes for the detection of ciprofloxacin in milk.
Elancheziyan, Mari; Lee, Sooyeon; Yoon, Tae Hyun; Singh, Manisha; Lee, Dogyeong; Won, Keehoon.
Afiliação
  • Elancheziyan M; Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea.
  • Lee S; Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea.
  • Yoon TH; Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea.
  • Singh M; Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea.
  • Lee D; Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea.
  • Won K; Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea. keehoon@dongguk.edu.
Mikrochim Acta ; 191(9): 507, 2024 08 05.
Article em En | MEDLINE | ID: mdl-39098931
ABSTRACT
An electrochemical sensor based on an electroactive nanocomposite was designed for the first time consisting of electrochemically reduced graphene oxide (ERGO), polyaniline (PANI), and poly(alizarin red S) (PARS) for ciprofloxacin (CIPF) detection. The ERGO/PANI/PARS-modified screen-printed carbon electrode (SPCE) was constructed through a three-step electrochemical protocol and characterized using FTIR, UV-visible spectroscopy, FESEM, CV, LSV, and EIS. The new electrochemical CIPF sensor demonstrated a low detection limit of 0.0021 µM, a broad linear range of 0.01 to 69.8 µM, a high sensitivity of 5.09 µA/µM/cm2, and reasonable selectivity and reproducibility. Moreover, the ERGO/PANI/PARS/SPCE was successfully utilized to determine CIPF in milk with good recoveries and relative standard deviation (< 5%), which were close to those with HPLC analysis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carbono / Ciprofloxacina / Antraquinonas / Leite / Eletrodos / Técnicas Eletroquímicas / Limite de Detecção / Grafite / Compostos de Anilina Limite: Animals Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carbono / Ciprofloxacina / Antraquinonas / Leite / Eletrodos / Técnicas Eletroquímicas / Limite de Detecção / Grafite / Compostos de Anilina Limite: Animals Idioma: En Ano de publicação: 2024 Tipo de documento: Article