Your browser doesn't support javascript.
loading
Electroactive Molecularly Imprinted Polymer Nanoparticles (eMIPs) for Label-free Detection of Glucose: Toward Wearable Monitoring.
Garg, Saweta; Singla, Pankaj; Kaur, Sarbjeet; Crapnell, Robert D; Banks, Craig E; Seyedin, Shayan; Peeters, Marloes.
Afiliação
  • Garg S; Department of Chemical Engineering, The University of Manchester, Engineering building A, East Booth Street, Oxford Road, Manchester, M13 9PL, UK.
  • Singla P; School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, UK.
  • Kaur S; Department of Chemical Engineering, The University of Manchester, Engineering building A, East Booth Street, Oxford Road, Manchester, M13 9PL, UK.
  • Crapnell RD; School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, UK.
  • Banks CE; School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, UK.
  • Seyedin S; Department of Chemistry, Centre for Advanced Studies, Guru Nanak Dev University, Amritsar, Punjab, 143005, India.
  • Peeters M; Faculty of Science and Engineering, Manchester Metropolitan University, Manchester, M1 5GD, UK.
Small ; : e2403320, 2024 Aug 07.
Article em En | MEDLINE | ID: mdl-39113348
ABSTRACT
The diagnosis of diabetes mellitus (DM) affecting 537 million adults worldwide relies on invasive and costly enzymatic methods that have limited stability. Electroactive polypyrrole (PPy)-based molecularly imprinted polymer nanoparticles (eMIPs) have been developed that rival the affinity of enzymes whilst being low-cost, highly robust, and facile to produce. By drop-casting eMIPs onto low-cost disposable screen-printed electrodes (SPEs), sensors have been manufactured that can electrochemically detect glucose in a wide dynamic range (1 µm-10 mm) with a limit of detection (LOD) of 26 nm. The eMIPs sensors exhibit no cross reactivity to similar compounds and negligible glucose binding to non-imprinted polymeric nanoparticles (eNIPs). Measurements of serum samples of diabetic patients demonstrate excellent correlation (>0.93) between these eMIPs sensor and the current gold standard Roche blood analyzer test. Finally, the eMIPs sensors are highly durable and reproducible (storage >12 months), showcasing excellent robustness and thermal and chemical stability. Proof-of-application is provided via measuring glucose using these eMIPs sensor in a two-electrode configuration in spiked artificial interstitial fluid (AISF), highlighting its potential for non-invasive wearable monitoring. Due to the versatility of the eMIPs that can be adapted to virtually any target, this platform technology holds high promise for sustainable healthcare applications via providing rapid detection, low-cost, and inherent robustness.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article