Your browser doesn't support javascript.
loading
Current use, training, and barriers in point-of-care ultrasound in nephrology: A national survey of VA medical centers.
Clin Nephrol ; 102(5): 257-263, 2024 Nov.
Article em En | MEDLINE | ID: mdl-39120088
ABSTRACT

BACKGROUND:

Point-of-care ultrasound (POCUS) can improve diagnostic accuracy, reduce procedural complications and enhance physician-patient interactions in nephrology. Currently, there is limited knowledge about how practicing nephrologists are using POCUS.

OBJECTIVE:

This study aimed to characterize current POCUS use, training needs, and barriers to use among nephrology groups. MATERIALS AND

METHODS:

A prospective observational study of all Veterans Affairs (VA) medical centers was conducted between August 2019 and March 2020 using a web-based survey sent to all chiefs of staff and nephrology specialty chiefs.

RESULTS:

Chiefs of staff (n = 130) and nephrology chiefs (n = 79) completed surveys on facility- and service-level POCUS use (response rates of 100% and 77%, respectively). Current diagnostic or procedural POCUS use was reported by 41% of nephrology groups, and the most common POCUS applications were central line insertion (28%) and assessment of urinary retention (23%), hydronephrosis (18%), volume status (15%), and bladder (14%). Lack of training was the most common barrier (72%), and most nephrology groups (65%) desired POCUS training. Limited access to ultrasound equipment and POCUS training were barriers reported by 54% and 18% of groups, respectively.

CONCLUSION:

A minority of nephrology groups currently use common POCUS applications including evaluation of urinary retention, hydronephrosis, and volume status. The most common barriers to POCUS use in nephrology were lack of trained providers and ultrasound equipment. Investment in POCUS training and infrastructure is needed to expand and standardize POCUS use in nephrology.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ultrassonografia / Sistemas Automatizados de Assistência Junto ao Leito / Nefrologia Limite: Humans País/Região como assunto: America do norte Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ultrassonografia / Sistemas Automatizados de Assistência Junto ao Leito / Nefrologia Limite: Humans País/Região como assunto: America do norte Idioma: En Ano de publicação: 2024 Tipo de documento: Article