Your browser doesn't support javascript.
loading
Differential phase contrast from electrons that cause inner shell ionization.
Deimetry, Michael; Petersen, Timothy C; Brown, Hamish G; Weyland, Matthew; Findlay, Scott D.
Afiliação
  • Deimetry M; School of Physics and Astronomy, Monash University, Clayton, Victoria, 3800, Australia.
  • Petersen TC; Monash Centre for Electron Microscopy, Monash University, Clayton, Victoria, 3800, Australia.
  • Brown HG; Ian Holmes Imaging Center, University of Melbourne, Parkville, Victoria, 3052, Australia.
  • Weyland M; Monash Centre for Electron Microscopy, Monash University, Clayton, Victoria, 3800, Australia.
  • Findlay SD; School of Physics and Astronomy, Monash University, Clayton, Victoria, 3800, Australia. Electronic address: scott.findlay@monash.edu.
Ultramicroscopy ; 266: 114036, 2024 Dec.
Article em En | MEDLINE | ID: mdl-39213860
ABSTRACT
Differential Phase Contrast (DPC) imaging, in which deviations in the bright field beam are in proportion to the electric field, has been extensively studied in the context of pure elastic scattering. Here we discuss differential phase contrast formed from core-loss scattered electrons, i.e. those that have caused inner shell ionization of atoms in the specimen, using a transition potential approach for which we study the number of final states needed for a converged calculation. In the phase object approximation, we show formally that differential phase contrast formed from core-loss scattered electrons is mainly a result of preservation of elastic contrast. Through simulation we demonstrate that whether the inelastic DPC images show element selective contrast depends on the spatial range of the ionization interaction, and specifically that when the energy loss is low the delocalisation can lead to contributions to the contrast from atoms other than that ionized. We further show that inelastic DPC images remain robustly interpretable to larger thicknesses than is the case for elastic DPC images, owing to the incoherence of the inelastic wavefields, though subtleties due to channelling remain. Lastly, we show that while a very high dose will be needed for sufficient counting statistics to discern differential phase contrast from core-loss scattered electrons, there is some enhancement of the signal-to-noise ratio with thickness that makes inelastic DPC imaging more achievable for thicker samples.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article