Radioxenon ventilation studies with disposable apparatus: technique and application.
Clin Nucl Med ; 4(12): 502-8, 1979 Dec.
Article em En | MEDLINE | ID: mdl-527287
ABSTRACT
Modification of commercially supplied disposable apparatus for radioxenon ventilation imaging solved several problems occasional poor inhalation of the initial bolus of gas, awkward initiation of the wash-out phase, and building up of pressure against which the patient must exhale in the wash-out phase. Two cases illustrate results of ventilation and perfusion imaging in chronic obstructive pulmonary disease and pulmonary embolism. A third case illustrates results before and after bullectomy, including quantitative data analysis of the wash-out phase. Although long-range economy is possible with permanent equipment, the use of the modified disposable apparatus may be preferable in certain circumstances.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração / Radioisótopos de Xenônio / Cintilografia / Pneumopatias Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1979 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração / Radioisótopos de Xenônio / Cintilografia / Pneumopatias Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1979 Tipo de documento: Article