Your browser doesn't support javascript.
loading
Brain perfusion SPECT with 99mTc-bicisate: comparison with PET measurement and linearization based on permeability-surface area product model.
Yonekura, Y; Tsuchida, T; Sadato, N; Nishizawa, S; Iwasaki, Y; Mukai, T; Konishi, J; Shibasaki, H.
Afiliação
  • Yonekura Y; Department of Brain Pathophysiology, Kyoto University School of Medicine, Japan.
J Cereb Blood Flow Metab ; 14 Suppl 1: S58-65, 1994 Jan.
Article em En | MEDLINE | ID: mdl-8263073
To characterize a recently introduced cerebral perfusion tracer, 99mTc-bicisate, single photon emission computed tomography (SPECT) images of 99mTc-bicisate were compared with CBF images obtained by positron emission tomography (PET) using the 15O steady-state method in 10 cases of cerebrovascular disease and dementia. 99mTc-Bicisate SPECT and PET CBF images showed a similar distribution pattern except for two cases with subacute stroke, in which 99mTc-bicisate showed less uptake than CBF in the infarcted area where oxygen metabolism was severely diminished. Comparison of 99mTc-bicisate uptake and CBF in the other eight cases showed less contrast between high- and low-flow regions in 99mTc-bicisate SPECT. Although the SPECT count ratio of cerebral structures to cerebellum showed a good correlation with CBF ratio, it gradually deviated from the linear relationship in the high-flow range. Assuming this nonlinear relationship is due to the limited extraction of the tracer, we estimated the permeability-surface area product (PS) value by a nonlinear least-squares curve-fitting procedure. The correction of the nonlinear relationship using the estimated PS value and a table lookup method resulted in an excellent linear relationship between corrected SPECT counts and CBF.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Tomografia Computadorizada de Emissão / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Circulação Cerebrovascular / Cisteína Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1994 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Tomografia Computadorizada de Emissão / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Circulação Cerebrovascular / Cisteína Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1994 Tipo de documento: Article