Your browser doesn't support javascript.
loading
False pulmonary artery catheter measurements due to the scimitar (hypogenetic lung) syndrome. Potential for iatrogenic pulmonary edema.
Pomerantz, S M; Mirvis, S E; Siegel, E L; Belzberg, H.
Afiliação
  • Pomerantz SM; Department of Diagnostic Radiology, University of Maryland Medical Center, Baltimore.
Chest ; 103(6): 1895-7, 1993 Jun.
Article em En | MEDLINE | ID: mdl-8404123
ABSTRACT
In an acute trauma patient with unrecognized scimitar syndrome, physiologic measurements used in patient management decisions were misleading due to the anatomic and physiologic anomalies of the syndrome. Pulmonary artery catheter measurements believed to reflect left atrial pressures were actually measuring central venous pressures because the catheter was terminating in the scimitar vein. These erroneous measurements led to overly aggressive fluid resuscitation and iatrogenic pulmonary edema. The pathologic features of scimitar syndrome are reviewed, and the mechanism for potential mismanagement of patient volume status created by aberrant pulmonary hemodynamics is discussed.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Pulmonar / Edema Pulmonar / Síndrome de Cimitarra / Cateterismo / Hemodinâmica Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 1993 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Pulmonar / Edema Pulmonar / Síndrome de Cimitarra / Cateterismo / Hemodinâmica Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 1993 Tipo de documento: Article