Do false positive thallium-201 scans lead to unnecessary catheterization? Outcome of patients with perfusion defects on quantitative planar thallium-201 scintigraphy.
J Am Coll Cardiol
; 21(5): 1058-63, 1993 Apr.
Article
em En
| MEDLINE
| ID: mdl-8459058
OBJECTIVES: We postulated that artifactually abnormal thallium-201 scans are well identified at the time of initial clinical interpretation by experienced readers and do not lead to unnecessary coronary angiography. BACKGROUND: Exercise thallium-201 scintigraphy employing quantitative imaging techniques has yielded sensitivity and specificity values of 80% to 90%. There are image artifacts, such as breast shadows, and variants of normal that, if not correctly identified, can lead to a high false positive rate for detection of coronary artery disease. METHODS: Data from 338 consecutive patients with one or more focal thallium-201 defects on quantitative planar images were reviewed. All patients had undergone symptom-limited exercise scintigraphy and were classified as having either artifactual or nonartifactual thallium-201 defects after review of clinical reports. RESULTS: Of the 265 patients with defects judged to be nonartifactual on clinical readings, 167 underwent coronary angiography, which demonstrated significant coronary artery disease (> or = 50% stenosis) in 161 (96%) and normal findings in 6. Four of the latter six had documented prior myocardial infarction. The remaining 73 patients (85% female) had thallium-201 defects deemed to be artifactual on clinical readings, chiefly as a result of breast (66%) and diaphragmatic (8%) attenuation or variants of normal (26%). Only 4 (5%) of the 73 patients underwent subsequent coronary angiography; none had coronary artery disease. One had aortic stenosis and two had variant angina. Follow-up (mean 20 +/- 2 months) of the 69 patients in this group who did not undergo coronary angiography revealed no deaths and one nonfatal non-Q wave myocardial infarction. CONCLUSIONS: Artifactual defects on quantitative planar thallium-201 scintigraphy are well recognized by experienced interpreters and do not result in a high false positive rate leading to unnecessary cardiac catheterization. The incidence of coronary artery disease is high in patients with thallium-201 defects judged to be nonartifactual, and many patients with perfusion defects and angiographically normal coronary arteries have organic heart disease.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Radioisótopos de Tálio
/
Doença das Coronárias
/
Vasos Coronários
Tipo de estudo:
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
1993
Tipo de documento:
Article