Your browser doesn't support javascript.
loading
A biomechanical evaluation of suture anchors in repair of the rotator cuff.
Rossouw, D J; McElroy, B J; Amis, A A; Emery, R J.
Afiliação
  • Rossouw DJ; St Mary's Hospital, London, England, UK.
J Bone Joint Surg Br ; 79(3): 458-61, 1997 May.
Article em En | MEDLINE | ID: mdl-9180329
ABSTRACT
Repair of the rotator cuff requires secure reattachment, but large chronic defects cause osteoporosis of the greater tuberosity which may then have insufficient strength to allow proper fixation of the tendon. Recently, suture anchors have been introduced, but have not been fully evaluated. We have investigated the strength of suture-to-anchor attachment, and the use of suture anchors in repairs of the rotator cuff either to the greater tuberosity or the lateral cortex of the humerus. The second method gave a significant increase in the strength of the repair (p = 0.014). The repairs were loaded cyclically and failed at low loads by cutting into bone and tendon, casting doubt on the integrity of the repair in early mobilisation after surgery. Repairs with suture anchors did not perform better than those with conventional transosseous attachment.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Suturas / Manguito Rotador Limite: Aged / Humans Idioma: En Ano de publicação: 1997 Tipo de documento: Article