Your browser doesn't support javascript.
loading
Diagnostic accuracy of transesophageal echocardiography during cardiopulmonary resuscitation.
van der Wouw, P A; Koster, R W; Delemarre, B J; de Vos, R; Lampe-Schoenmaeckers, A J; Lie, K I.
Afiliação
  • van der Wouw PA; Department of Cardiology, Academic Medical Centre, Amsterdam, The Netherlands. p.a.vanderwouw@amc.uva.nl
J Am Coll Cardiol ; 30(3): 780-3, 1997 Sep.
Article em En | MEDLINE | ID: mdl-9283540
ABSTRACT

OBJECTIVES:

We sought to establish the diagnostic accuracy of transesophageal echocardiography (TEE) during cardiopulmonary resuscitation.

BACKGROUND:

Because of its bedside diagnostic capabilities, excellent cardiac images and lack of interference with resuscitation efforts, TEE is ideally suited to determine the cause of a circulatory arrest that is not due to severe arrhythmia. However, the diagnostic accuracy of TEE during resuscitation is unknown.

METHODS:

TEE was performed in patients with prolonged circulatory arrest. The TEE diagnoses were compared with diagnoses from autopsy, surgery and clinical follow-up.

RESULTS:

Of the 48 study patients (29 male, 19 female, mean age +/- SD 61 +/- 20 years), 28 had an in-hospital cardiac arrest and 20 an out-of-hospital onset of arrest. Forty-four patients eventually died; four survived to discharge. The diagnoses made with TEE were cardiac tamponade (n = 6), myocardial infarction (n = 21), pulmonary embolism (n = 6), ruptured aorta (n = 1), aortic dissection (n = 4), papillary muscle rupture (n = 1), other diagnosis (n = 2) and absence of structural cardiac abnormalities (n = 7). A definite diagnosis from a reference standard was available in 31 patients. The TEE diagnosis was confirmed in 27 of the 31-by postmortem examination (n = 19), operation (n = 2), angiography (n = 2) or clinical course (n = 4). In the other four patients the TEE diagnosis proved incorrect by postmortem examination. The sensitivity, specificity and positive predictive value of TEE were 93%, 50% and 87%, respectively. In 15 patients (31%), major therapeutic decisions were based on TEE findings.

CONCLUSIONS:

TEE can reliably establish the cause of a circulatory arrest during cardiopulmonary resuscitation.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Embolia Pulmonar / Tamponamento Cardíaco / Reanimação Cardiopulmonar / Ecocardiografia Transesofagiana / Parada Cardíaca / Infarto do Miocárdio Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1997 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Embolia Pulmonar / Tamponamento Cardíaco / Reanimação Cardiopulmonar / Ecocardiografia Transesofagiana / Parada Cardíaca / Infarto do Miocárdio Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1997 Tipo de documento: Article