Your browser doesn't support javascript.
loading
Planimetry of aortic valve area using multiplane transoesophageal echocardiography is not a reliable method for assessing severity of aortic stenosis.
Bernard, Y; Meneveau, N; Vuillemenot, A; Magnin, D; Anguenot, T; Schiele, F; Bassand, J P.
Afiliação
  • Bernard Y; Cardiology Department, Saint-Jacques University Hospital, Besançon, France.
Heart ; 78(1): 68-73, 1997 Jul.
Article em En | MEDLINE | ID: mdl-9290405

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Ecocardiografia Transesofagiana Tipo de estudo: Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1997 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Ecocardiografia Transesofagiana Tipo de estudo: Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1997 Tipo de documento: Article