Your browser doesn't support javascript.
loading
Positron emission tomography in the evaluation of the N0 neck.
Myers, L L; Wax, M K; Nabi, H; Simpson, G T; Lamonica, D.
Afiliação
  • Myers LL; Department of Otolaryngology-Head and Neck Surgery, State University of New York at Buffalo, School of Medicine and Biomedical Sciences, Veterans Affairs Medical Center at Buffalo, 14215, USA.
Laryngoscope ; 108(2): 232-6, 1998 Feb.
Article em En | MEDLINE | ID: mdl-9473074
The presence of cervical lymph node metastasis in patients with head and neck cancer is associated with an unfavorable prognosis. Reports vary as to whether various conventional radiographic studies, such as computed tomography (CT) and magnetic resonance imaging, confer an advantage over physical examination in the patient without clinical findings of cervical metastasis (N0). Positron emission tomography (PET) is a functional imaging modality that has recently been used for head and neck neoplasms. The use of PET in the evaluation of the N0-staged neck in 14 consecutive patients with squamous cell carcinoma (SCC) of the upper aerodigestive tract is reported. Seven patients (50%) undergoing 13 neck dissections had pathologic evidence of disease. PET scans were positive in five patients with pathologically confirmed cervical metastasis. PET scans were negative in seven patients (11 neck dissections) with no pathologic evidence of disease. PET scans were positive for unilateral cervical metastasis in two of three patients with involvement of a single lymph node. PET scans were positive in two of three patients with more than two lymph nodes involved. PET had an accuracy of 100% in the eight patients with SCC of the oral cavity. In patients with oropharyngeal or hypopharyngeal carcinoma PET localized cervical metastasis in two of four patients with neck metastasis. In the patient with an N0-staged neck on clinical examination, PET was found to have an overall sensitivity of 78%, specificity of 100%, positive predictive value of 100%, negative predictive value of 88%, and accuracy of 92%. CT demonstrated sensitivity of 57%, specificity of 90%, positive predictive value of 80%, negative predictive value of 75%, and accuracy of 76%. PET showed a trend in increased accuracy (P = 0.11) over CT. PET appears to be a promising diagnostic aid that may be applied when evaluating the N0-staged neck, especially for SCC of the oral cavity.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carcinoma de Células Escamosas / Tomografia Computadorizada de Emissão / Neoplasias de Cabeça e Pescoço Tipo de estudo: Diagnostic_studies / Incidence_studies / Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 1998 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carcinoma de Células Escamosas / Tomografia Computadorizada de Emissão / Neoplasias de Cabeça e Pescoço Tipo de estudo: Diagnostic_studies / Incidence_studies / Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 1998 Tipo de documento: Article