Your browser doesn't support javascript.
loading
Technetium-99m dimercaptosuccinic acid scintigraphy studies of renal cortical scarring and renal length.
Rossleigh, M A; Farnsworth, R H; Leighton, D M; Yong, J L; Rose, M; Christian, C L.
Afiliação
  • Rossleigh MA; Department of Nuclear Medicine, Prince of Wales Hospital, Randwick NSW, Sydney, Australia.
J Nucl Med ; 39(7): 1280-5, 1998 Jul.
Article em En | MEDLINE | ID: mdl-9669411
ABSTRACT
UNLABELLED The aims of this study were to validate 99mTc-dimercaptosuccinic acid (DMSA) scintigraphy appearances with histopathological features of scarring; to evaluate the sensitivity and specificity of 99mTc-DMSA and ultrasound for the detection of renal scarring; to compare planar, pinhole and SPECT techniques when using 99mTc-DMSA; and to compare 99mTc-DMSA and ultrasound renal length measurement.

METHODS:

Reflux nephropathy was induced in large white pigs using established methods. To ensure that the abnormalities detected were scars and not inflammatory changes, the pigs were not studied until 3 mo after the treated episode of acute pyelonephritis confirmed by 99mTc-DMSA.

RESULTS:

Twenty pigs were enrolled in the study. Eleven reached the end point, but only nine pigs (18 kidneys) were available for analysis. Thirty-four scars were identified pathologically; 24 were present macroscopically and a further 10 were seen only on microscopy. Technetium-99m-DMSA abnormalities correlated with scars histopathologically with an accuracy of 92% versus that of ultrasound, 75% (p < 0.001). Technetium-99m-DMSA more accurately identified scarring with a higher sensitivity (76% versus 29%) and specificity (98% versus 92%) than ultrasound. On the 99mTc-DMSA study, pinhole imaging had the highest accuracy (92%) when compared with planar (90%) and SPECT (87%) data. These differences were not statistically significant. Renal lengths as measured on 99mTc-DMSA more closely correlated with length measurement at pathological examination than ultrasound. Technetium-99m-DMSA measurement was, on average, 6% higher than pathology, and ultrasound was, on average, 22% lower.

CONCLUSION:

Technetium-99m-DMSA appears to be the preferred method for the detection of renal cortical scarring and accurate renal length measurement when compared with ultrasound examination.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pielonefrite / Refluxo Vesicoureteral / Compostos Radiofarmacêuticos / Ácido Dimercaptossuccínico Tecnécio Tc 99m / Rim / Córtex Renal Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 1998 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pielonefrite / Refluxo Vesicoureteral / Compostos Radiofarmacêuticos / Ácido Dimercaptossuccínico Tecnécio Tc 99m / Rim / Córtex Renal Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 1998 Tipo de documento: Article