Noninvasive mechanical ventilation in a patient with respiratory failure after hematopoietic progenitor transplantation.
Marín, D; González-Barca, E; Domingo, E; Berlanga, J; Grañena, A.
Afiliação
  • Marín D; Clinical Hematology Service, Ciutat Sanitaria i Universitaria de Bellvitge, Hospital Duran i Reynals, Institut Catalá d'Oncologia, Barcelona, Spain.
Bone Marrow Transplant ; 22(11): 1123-4, 1998 Dec.
Article em En | MEDLINE | ID: mdl-9877278
ABSTRACT
Respiratory failure requiring orotracheal intubation (OTI) and mechanical ventilation (MV) is almost always a fatal complication in patients who undergo hematopoietic progenitor transplantation (HPT). We present the case of a woman who suffered respiratory failure with bilateral infiltrates on a chest X-ray taken on day +14 following autologous bone marrow transplantation. We managed the patient satisfactorily with noninvasive ventilation, avoiding OTI. We believe that patients with non-progressive pulmonary lesions and without multiple system organ failure, may be correctly managed with noninvasive positive-pressure ventilation (NPPV).
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Insuficiência Respiratória / Respiração com Pressão Positiva / Transplante de Células-Tronco Hematopoéticas Limite: Aged / Female / Humans Idioma: En Ano de publicação: 1998 Tipo de documento: Article