1.
São Paulo; s.n; 2010. 89 p. ilus, tab, graf. (BR).
Tese em Português | BBO - Odontologia | ID: biblio-865581

RESUMO

A infiltração de fluido e bactérias nos espaços internos dos implantes foi observada em pilares intermediários parafusados, tanto em situações in vitro quanto in vivo devido à microfenda existente entre o implante e o pilar intermediário. Esse fato pode estar relacionado com a inflamação dos tecidos periimplantares e também com a produção de mau odor. O objetivo do presente estudo in vitro foi avaliar e comparar a ocorrência de infiltração de fluidos pela interface implante-pilar intermediário em três sistemas de implante com conexão do tipo cone Morse, e a capacidade de vedação de um adesivo anaeróbico, utilizando o radioisótopo Tecnécio-99m como marcador. Na primeira etapa, dez conjuntos implante-pilar intermediário de cada sistema foram imersos em solução contendo esse marcador, após a aplicação do torque recomendado pelo fabricante, e foram mantidos em pressão constante de 2 atm por um minuto. Na segunda etapa, um adesivo anaeróbico foi aplicado no pilar intermediário antes do mesmo ser parafusado ao seu respectivo implante. Após a aplicação da pressão, o infiltrado presente no interior dos implantes foi coletado com pontas de papel. Esse material foi depositado em tubos de ensaio para posterior leitura da radioatividade presente. A infiltração de fluido pela interface implante-pilar intermediário mostrou ser um fenômeno mensurável em todas as amostras dos três sistemas de implante com conexão do tipo cone Morse testados...


A quantidade de infiltrado variou entre os sistemas e entre as amostras. A inconstância das amostras foi observada em todos os sistemas, no entanto, foi observado que o valor de infiltrado encontrado no Grupo 1 foi significantemente maior (p<0,05) do que o encontrado no Grupo 2, e não houve diferença estatística significante entre os Grupos 1 e 3, e entre os Grupos 2 e 3. Também foi observado que, com o uso do adesivo anaeróbico, os sistemas apresentaram diminuição da quantidade de infiltrado, sendo que a análise estatística dos valores obtidos com e sem o seu uso, mostraram significância a 1%. Além disso, com o uso do adesivo anaeróbico os três sistemas de implante testados passaram a ter comportamento semelhante, não tendo sido encontrada diferença estatística significante entre eles (p=0,5451). Considerando os limites deste estudo, pode-se concluir que os três sistemas de implante com conexão do tipo cone Morse testados permitiram a passagem de fluido do meio externo para o interior dos implantes, e que o material testado não foi capaz de impedir a penetração de fluido, apesar de ter reduzido significantemente a quantidade de infiltrado em todos os sistemas.


It has been observed that in implants with screw-retained abutments, in in vitro as well as in vivo conditions, bacteria and fluids can penetrate the inner implant space as consequence of an existing microgap at the implant-abutment interface. This fact can be related to peri-implant tissue inflammation and malodor. The aim of the present study was to evaluate and compare the occurrence of fluid penetration throught implant-abutment interface in three cone Morse implant systems and sealing ability of an anaerobic adhesive using a radioisotope as trace. In the first phase, ten implant-abutment sets of each system were immersed in a solution with radioisotope, after manufacture recommended torque application. All assemblies were kept in a constant pressure of 2 atm for one minute. In the second phase, an anaerobic adhesive was applied before the abutments been torque-tightened to the same implant. After the pressure application, material inside implant bodies was colleted using a paper cone that was transferred to tubes for posterior verification of radioactivity.


Fluid penetration at the implant-abutment interface was seen to be a recordable phenomenon in each assembly of the three cone Morse systems tested in this study. The quantity of infiltrated varied between systems and assemblies. The variable of the samples was observed in all systems, however, it was noted that the value of infiltrate found in Group 1 was significantly higher than that found in Group 2, and there was no statistical significant difference between the groups 1 and 3, and between groups 2 and 3. It was also noted that, using the adhesive anaerobic, the implant systems showed reduce infiltrate, and statistical analysis presented significance to 1%. Moreover, with the use of anaerobic adhesive, all three implant systems tested presented similar pattern, and no significant statistical difference was found (p=0,5451). Considering the limits of this study, the following conclusions can be drawn: the three cone Morse implant systems tested allowed the passage of fluid from external to the inside of the implants, and that the material tested was not capable of preventing the fluid penetration, despite having reduced significantly the amount of infiltrate in all systems


Assuntos
Implantes Dentários , Infiltração Dentária/diagnóstico , Radioisótopos/efeitos da radiação
2.
São Paulo; s.n; 2009. 180 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-546295

RESUMO

A importância do aumento da permeabilidade e da limpeza da dentina radicular está ligada à melhora da sanificação e obturação do sistema de canais radiculares...


The permeability increasing and the cleanliness of root dentin walls are important to improve the sanitization and root canal filling. Thus, this study aimed to evaluate the variations of root dentin permebility of human teeth, after endodontic preparation followed by Er:YAG and Nd:YAG laser irradiation, using free Technetium-99m radioisotope (99mTc) as tracer. Additionally, SEM images were analyzed to evaluate the cleanliness of dentin walls and possible bacterial adhesion after Enterococcus faecalis inoculation...


Assuntos
Endodontia , Lasers , Permeabilidade Dentária/efeitos da radiação , Radioisótopos , Tecnécio
3.
Rev. Assoc. Paul. Cir. Dent ; 40(2): 174-82, mar.-abr. 1986. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-108713

RESUMO

Trata-se de um estudo com isótopos radioativos aplicados ao campo da implantologia oral. Foi iniciado em 1973, com a utilizaçäo do estrôncio radioativo 85 e continuou de acordo com a evoluçäo da Medicina Nuclear. Atualmente, os mapeamentos ósseos säo realizados com o tecnécio 99m e os cintilogramas säo obtidos em uma gama-câmara acoplada a um computador. Após 12 anos de estudos, o autor oferece um novo método semiológico, näo invasivo, obtendo informaçöes näo conseguidas por outros métodos na avaliaçäo da estrutura óssea onde se alojam os implantes aloplásticos