Resultados 1 - 20 de 61
Filtrar
1.
Braz. j. oral sci ; 21: e224977, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1354723

RESUMO

Aim: This study aims to evaluate the clinical assessment results of periimplant soft tissue with morse taper (internal abutment connection). Methods: The study was conducted using a rapid review by searching the articles from PubMed NCBI and Cochrane by using keywords. All articles were selected by the year, duplication, title, abstract, full-text, and finally, all selected articles were processed for final review. Following clinical parameters were included; Periimplant Probing Pocket Depth (PPD), Plaque Score (PS), modified Plaque Index (mPI), Mucosal Thickness (MTh), Gingival Height (GH), periimplant mucosal zenith, Pink Esthetic Score (PES), Bleeding On Probing (BOP), Sulcus Bleeding Index (SBI), and modified Gingival Index (mGI). Results: 9 selected articles were obtained from the initial literature searching count of 70 articles. The overall samples included 326 morse taper implants. Based on the evaluation, 3 out of 4 articles reported pocket depth < 4 mm, no bleeding was reported in 2 out of 4 articles. 4 out of 4 articles reported low plaque accumulation, low soft tissue recession was reported in 3 out of 3 articles, and 4 out of 4 articles reported acceptable PES values. Conclusion: The evaluations indicate that the morse taper (internal abutment connection) has favorable assessment results based on various clinical parameters


Assuntos
Implantes Dentários , Dente Suporte , Lesões dos Tecidos Moles , Projeto do Implante Dentário-Pivô , Gengiva , Mucosa Bucal
2.
Araçatuba; s.n; 2022. 127 p. tab, graf, ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1435801

RESUMO

Atualmente, devido a perda do elemento dentário e a procura por um tratamento estético e principalmente funcional, a reabilitação com próteses sobre implante tem sido amplamente empregada, com elevada previsibilidade a longo prazo. Com isso, muito tem sido relatado na literatura acerca das possíveis complicações dessa modalidade de tratamento, principalmente relacionado às possibilidades de falhas mecânicas das próteses implantossuportadas. Por isso, o objetivo do presente projeto foi avaliar a influência na adaptação marginal e interna, da utilização do intermediário protético e do tipo de retenção das próteses (parafusada e cimentada) em implantes cone morse submetidos à ciclagem mecânica. Foram confeccionados 40 corpos de prova, no qual cada um tinha a presença de um implante, com as dimensões de 4mm de diâmetro e 11,5mm de comprimento cone morse (n = 40). Dessa forma, foi avaliado a influência da utilização do intermediário e dos sistemas de retenção em cada conexão de maneira específica. Metade dos corpos de prova de cada sistema de conexão foram confeccionados em UCLA (n=20, sendo 10 parafusadas e 10 cimentadas), enquanto que a outra metade foi utilizado um intermediário pré-fabricado (Pilar Universal (n=20, sendo 10 parafusadas e 10 cimentadas). Os corpos de prova foram submetidos à ciclagem mecânica submersos em água destilada simulando um tempo clínico de cinco anos. Além disso, foram avaliados quanto ao torque e destorque (N) e adaptação marginal e interna (µm) antes e após a ciclagem mecânica. Os dados provenientes das mensurações foram organizados em tabela em formato Excel (Microsoft Office Excel, Redmond, WA, Estados Unidos) e submetidos ao software SigmaPlot (SigmaPlot, San Jose, CA, EUA) versão 12.0. Todos os dados foram analisados inicialmente com a utilização da estatística descritiva. Em seguida, os dados para intrusão (valores positivos), extrusão (valores negativos), destorque inicial, destorque final, e descimentação foram analisados em relação a distribuição de normalidade (teste Shapiro-Wilk e igualdade de variância) e, posteriormente, foi adotada a Análise de Variância (ANOVA) a um fator (Grupos diferentes materiais: G1 a G4), quando houve normalidade dos dados, o pós teste de Tukey foi adotado para as comparações múltiplas, quando não foi identificado uma distribuição normal, empregou-se o teste de Kruskall-Wallis e pós-teste de Dunn's ou Tukey, semelhantemente foi realizada a análise específica das variáveis pilares (UCLA e Pilar Universal) e sistemas de retenção (Parafusado e Cimentado). Para todos os testes aplicou-se nível de significância de 5% (α=0,05). A análise gráfica foi considerada através de um gráfico de barras para os dados que apresentaram normalidade com valores de média e desvio padrão, e as demais análises que não apresentaram normalidade foi considerado a confecção de um boxplot para cada grupo comparativo. As próteses sobre implante utilizando pilares em zircônia tem ganhado cada vez mais espaço, além do estudo in vitro, foi realizada uma revisão sistemática para comparar a perda óssea marginal e as complicações próteticas de reabilitações utilizando pilares de zircônia cimentado e parafusado. Em relação as próteses cimentadas e parafusadas, devido as evidências conflitantes e a presença de muitas revisões sistemáticas sobre o tema, foi realizada uma overview de revisões sistemáticas, com o objetivo de compilar as informações disponiveis e avaliar a qualidade metodologica desses estudos a respeito das complicações presentes nas próteses sobre implante cimentadas ou parafusadas(AU)


Currently, due to the loss of the dental element and the search for an aesthetic and mainly functional treatment, rehabilitation with implant prostheses has been widely used, with high long-term predictability. Thus, much has been reported in the literature about the possible complications of this treatment modality, mainly related to the possibility of mechanical failure of implant-supported prostheses. Therefore, the objective of the present project was to evaluate the influence on the marginal and internal adaptation, the use of the prosthetic intermediate and the type of retention of the prostheses (screwed and cemented) in morse taper implants submitted to mechanical cycling. 40 specimens were made, in which each one had an implant, with dimensions of 4 mm in diameter and 11.5 mm in length (n = 40). In this way, the influence of the use of intermediaries and retention systems in each connection was evaluated in a specific way. Half of the specimens of each connection system were made in UCLA (n=20, being 10 screwed and 10 cemented), while the other half was used a prefabricated intermediate (Universal Abutment (n=20, being 10 screwed) and 10 cemented). The specimens were submitted to mechanical cycling submerged in distilled water simulating a clinical time of five years. In addition, they were evaluated for torque and detorque (N) and marginal and internal adaptation (µm) before and after mechanical cycling. Data from measurements were organized in a table in Excel format (Microsoft Office Excel, Redmond, WA, USA) and submitted to SigmaPlot software (SigmaPlot, San Jose, CA, USA) version 12.0. All data were initially analyzed using descriptive statistics. Then, data for intrusion (positive values), extrusion (negative values), initial detorque, final detorque, and debonding were analyzed in relation to dist determination of normality (Shapiro-Wilk test and equality of variance) and, later, the one-way Analysis of Variance (ANOVA) was adopted (Different material groups: G1 to G4), when there was normality of the data, the Tukey post test was adopted for multiple comparisons, when a normal distribution was not identified, the Kruskall-Wallis test and Dunn's or Tukey post-test were used, similarly the specific analysis of the pillar variables (UCLA and Universal Pillar) and systems retainer (Screwed and Cemented). For all tests, a significance level of 5% (α=0.05) was applied. The graphical analysis was considered through a bar graph for the data that presented normality with mean and standard deviation values, and the other analyzes that did not present normality was considered the creation of a boxplot for each comparative group. Implant prostheses using zirconia abutments have gained more and more space, in addition to the in vitro study, a systematic review was performed to compare marginal bone loss and prosthetic complications of rehabilitations using cemented and screwed zirconia abutments. Regarding cemented and screw-retained prostheses, due to conflicting evidence and the presence of many systematic reviews on the subject, an overview of systematic reviews was performed, with the objective of compiling the available information and evaluating the methodological quality of these studies regarding complications present in cemented or screw-retained implant prostheses(AU)


Assuntos
Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Estresse Mecânico , Implantes Dentários , Dente Suporte , Prótese Dentária , Adaptação Marginal Dentária , Falha de Restauração Dentária
3.
Braz. dent. sci ; 24(3): 1-16, 2021. tab, ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1281922

RESUMO

Objective: This study was performed to evaluate the use of PEEK abutments versus zirconium abutments with lithium disilicate superstructure on the esthetic acceptance and peri-implant clinical parameters. Zirconium abutments were found to have high surface roughness even after polishing. This causes a remarkable collapse of the soft tissue papilla that is a primary factor in the Pink Esthetic Score(PES), resulting in failed esthetic restoration in the anterior esthetic zone. Material and Methods:Twenty patients who needed a single implant restoration in the esthetic zone were included in this study. Eighteen patients completed screening, baseline, three-month, six-month, and twelve-month follow-up visits. At the screening visit, the patients were randomly allocated into two groups: Zirconia abutments (A) Group, and PEEK abutments (B) Group, both of which were restored with IPS e.max CAD superstructure. Patients Satisfaction was assessed by visual analogue scale (VAS). Pink esthetics score (PES), modified plaque index (mPI) and modified gingval index (mGI) were also assessed. Results: All implants were successfully osseo-integrated with a 100% survival rate over one year. Patient satisfaction was significantly higher for the PEEK group than the zirconium group. The pink esthetic score showed no statistical significance between both groups. The modified plaque index was significantly lower for the PEEK group than the zirconium group. The modified gingival index showed no statistical difference between both groups. Conclusion: PEEK revealed to be a versatile material to replace zirconium for implant abutments, due to its lower plaque affinity and higher patient satisfaction (AU)


Objetivo: Este estudo foi realizado para avaliar o uso de pilares PEEK versus pilares de zircônia com estrutura de dissilicato de lítio quanto a aceitação estética e parâmetros clínicos peri-implantares. Os pilares de zircônia apresentam alta rugosidade superficial, mesmo após o polimento. Isso causa um colapso notável da papila do tecido mole, que é um fator primário no índice estético rosa (Pink Esthetic Score - PES), resultando em falha na restauração estética na zona estética anterior. Materiais e Métodos:Vinte pacientes que precisavam de um implante unitário na zona estética foram incluídos neste estudo. Dezoito pacientes completaram a triagem, a consulta inicial e as visitas de acompanhamento de três, seis e doze meses. Durante a triagem, os pacientes foram aleatoriamente divididos em dois grupos: Grupo Pilares de Zircônia (A) e Grupo de Pilares PEEK (B), ambos foram restaurados com IPS e.max CAD. A satisfação dos pacientes foi avaliada pela escala visual analógica (VAS). O PES, o índice de placa modificado (mPI) e o índice gengival modificado (mGI) também foram avaliados. Resultados: Todos os implantes foram osseointegrados com sucesso, com uma taxa de sobrevivência de 100% ao longo de um ano. A satisfação do paciente foi significativamente maior para o grupo PEEK quando comparado com o grupo de pilares de zircônia. O índice da estética rosa não apresentou significância estatística entre os dois grupos. O índice de placa modificado foi significativamente menor para o grupo PEEK quando comparado com o grupo de pilares de zircônia. Conclusão: O PEEK revelou-se um material versátil para substituir a zircônia em pilares de implante, devido a sua menor afinidade de placa e maior satisfação do paciente. (AU)


Assuntos
Humanos , Dente Suporte , Satisfação do Paciente , Implantação Dentária , Implantação Dentária Endóssea
4.
Braz. dent. j ; 31(4): 374-379, July-Aug. 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132322

RESUMO

Abstract The aim of this study was to verify the effect of the implant volume loss, vertical misfit between abutment and prosthetic platform, prosthetic screw loosening torque, and screw stress distribution in titanium and zirconia abutments. Ten CAD/CAM system custom abutments of each material were milled and attached to the titanium implants. The implant volume loss was evaluated by microtomography, the vertical misfit with optical microscopy, and digital torque wrench measured the prosthetic screw loosening. All experimental analyses were performed before and after mechanical cycle (1,000,000 cycles, 100 N/2 Hz). Virtual models of the structures were created for finite element analysis, and the stress on the screw obtained with von Mises procedure. Data were analyzed using an independent t-test, two-way ANOVA for repeated measures, and Tukey's HSD test (a=0.05). There was no significant difference in the implant volume loss for the two abutment materials (p=0.662). Titanium abutments provided higher loosening torque values after mechanical cycling (p<0.001). Lesser marginal misfit was obtained with titanium abutments before and after mechanical cycling (p<0.001). The stress distribution on the screw was similar between abutment materials. In conclusion, CAD/CAM custom titanium abutment reduced the marginal misfit and increased the torque maintenance of prosthetic screws when compared to CAD/CAM custom zirconia abutment.


Resumo O objetivo neste estudo foi verificar o efeito da diminuição de volume do implante, desajuste vertical entre o pilar e plataforma protética, torque de afrouxamento do parafuso protético e distribuição da tensão no parafuso em pilares de titânio e zircônia. Dez pilares personalizados de cada material foram fresados e conectados aos implantes de titânio. A diminuição de volume do implante foi avaliada com microtomografia, o desajuste vertical com microscopia óptica e o torque de afrouxamento do parafuso protético com chave de torque digital. Todas as análises experimentais foram realizadas antes e após aplicação do ciclo mecânico (1.000.000 ciclos, 100 N/2 Hz). Modelos virtuais das estruturas foram criados para análise por elementos finitos e a tensão no parafuso obtida com valores de von Mises. Os dados foram analisados usando teste t independente, análise de varância dois fatores para medidas repetidas e teste de Tukey HSD (a=0,05). Não houve diferença significativa na diminuição de volume do implante para os dois materiais do pilar (p= 0,662). Os pilares de titânio proporcionaram maiores valores de torque de afrouxamento após o ciclo mecânico (p<0,001). O menor desajuste marginal foi obtido com os pilares de titânio antes e após o ciclo mecânico (p<0,001). A distribuição da tensão no parafuso foi similar entre os materiais. Em conclusão, os pilares personalizados de titânio reduziram o desajuste marginal e aumentaram a manutenção do torque dos parafusos protéticos quando comparados aos pilares de zircônia.


Assuntos
Titânio , Dente Suporte , Zircônio , Parafusos Ósseos
5.
Braz. dent. j ; 31(2): 127-134, Mar.-Apr. 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132279

RESUMO

Abstract The aim of this study was to assess the internal and vertical marginal fit of metallic copings to abutments and the fracture strength of different narrow diameter dental implant/abutments, either submitted to thermomechanical cycling or not. Sixty-four implant/abutments (n=16) were divided into 4 groups according to diameter and abutment type: G3.5-UAC (morse taper implant Ø3.5mm + universal abutment with beveled chamfer finish); G2.9-UAS (morse taper implant Ø2.9mm + universal abutment with shoulder finish); G2.8-AA (morse taper friction implant Ø2.8mm + anatomical abutment) and G2.5-HP (one-piece implant Ø2.5mm with indexed hexagonal platform). Each group was divided into two subgroups (n=8): submitted and not submitted to thermomechanical cycling (TMC). To assess internal and vertical marginal fit of metallic copings, the assemblies were scanned using microtomography (micro-CT) (n=5). The samples were subjected to the compressive strength test on a universal test machine. Group G3.5-UAC showed the highest marginal misfit regardless of TMC (p<0.05). All other groups were similar after TMC. Group G2.8-AA showed the lowest internal misfit both with and without TMC (p<0.05). Group G2.8-AA showed the highest fracture strength, similar only to G2.5-HP without TMC and G3.5-UAC with TMC. The type of abutment affects the internal and marginal fit of metallic copings and the anatomical abutment led to the best internal and marginal coping fit. The narrow diameter dental implant/abutments differ in terms of fracture strength, the strongest assembly was that composed by implant of type V grade titanium without internal threads (friction implant).


Resumo O objetivo deste estudo foi avaliar a adaptação marginal e interna de cópings metálicos em pilares sobre implantes, e a resistência a fratura de diferentes conjuntos de implantes/pilares de diâmetro reduzido, submetidos à ciclagem termomecânica ou não. Sessenta e quatro implantes/pilares (n=16) foram divididos em 04 grupos de acordo com o tipo de pilar e diâmetro do implante: G3.5-UAC (implante cone morse Ø3.5mm + munhão universal com término em chanfro); G2.9-UAS (implante cone morse Ø2.9mm + munhão universal com término em ombro); G2.8-AA (implante cone morse friccional Ø2.8mm + munhão anatômico); e G2.5-HP (implante de corpo único de Ø2.5mm com plataforma hexagonal indexada). Cada grupo foi dividio em dois subgrupos (n=8): submetidos ou não à ciclagem termomecânica (TMC). As amostras foram escaneadas por microtomografia (micro-CT) para avaliar a adaptação interna e marginal vertical dos copings metálicos. As amostras foram submetidas à resistência à compressão em uma maquina de ensaios universal. O grupo G3.5-UAC apresentou os maiores valores de desadaptação marginal independentemente da TMC (p<0,05). Todos os outros grupos foram similares entre si após TMC. O grupo G2.8-AA demonstrou o menor desajuste interno independentemente de TMC (p<0,05). O grupo G2.8-AA demonstrou a maior resistência à fratura, similar apenas ao grupo G2.5-HP sem TMC e G3.5-UAC com TMC. O tipo de pilar influencia a adaptação interna e marginal vertical de copings metálicos. O grupo do pilar anatômico (sem entalhes na superfície) levou à melhor adaptação, enquanto o grupo com plataforma expandida hexagonal e os grupos com munhão universal (com entalhes na superfície) proporcionaram os maiores desajustes (especialmente com termino em chanfro). Os implantes/pilares de diâmetro reduzido diferem em termos de resistencia à fratura, sendo que o conjunto mais resistente foi aquele composto por titânio tipo V e sem roscas internas (implante friccional).


Assuntos
Implantes Dentários , Titânio , Zircônio , Teste de Materiais , Dente Suporte , Análise do Estresse Dentário , Projeto do Implante Dentário-Pivô , Resistência à Flexão
6.
J. appl. oral sci ; 28: e20200343, 2020. graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1143144

RESUMO

Abstract An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. Objective: This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (μCT). Methodology: Volumetric and linear (central and marginal) gaps of four Ti-base abutments (n=10/group): (i) Odontofix LTDA (OD), (ii) Singular Implants (SING), (iii) EFF Dental Components (EFF), and (iv) Control Group (S.I.N implants) compatible with an implant system (Strong SW, S.I.N Implants) were measured using μCT reconstructed polyvinyl siloxane replicas. Results: The results showed significantly lower volume gap for Control S.I.N (0.67±0.29 mm3) and SING (0.69±0.28 mm3) Ti-base abutments relative to OD (1.42±0.28 mm3) and EFF groups (1.04±0.28 mm3) (p<0.033), without significant difference between them (p=0.936). While gap values were homogenous in the central region, EFF presented a significantly higher marginal gap. Accordingly, the Control S.I.N and Singular Ti-base abutments showed improved volumetric and marginal fit relative to Odontofix and EFF. Conclusion: The method of manufacturing abutments influenced the misfit at the implant-abutment interface.


Assuntos
Implantes Dentários , Dente Suporte , Titânio , Técnicas de Réplica , Microtomografia por Raio-X , Projeto do Implante Dentário-Pivô
7.
Full dent. sci ; 9(33): 85-91, 2017. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-987489

RESUMO

A seleção de pilares protéticos é um desafio para o cirurgião-dentista, sendo essencial para o sucesso da reabilitação oral sobre implantes, visando à previsibilidade e longevidade. Essa seleção deve obedecer a um planejamento multidisciplinar reverso para obter sucesso estético e biomecânico. Este trabalho tem como finalidade apresentar uma técnica idealizada para desmistificar a escolha de componentes protéticos sobre implantes disponíveis no mercado, auxiliando o cirurgião-dentista a selecionar corretamente os pilares protéticos, bem como suas indicações e contraindicações. A Técnica dos 5 dedos atribui à cada dedo da mão um componente protético e também à cada dedo um fator a ser verificado nessa escolha: distância interoclusal, sulco periimplantar, angulação, elementos isolados ou múltiplos, próteses cimentadas ou aparafusadas. Permitindo, portanto, uma seleção objetiva e simples (AU).


The selection of prosthetic abutments is a challenge for the dentist, being essential for the success of oral rehabilitation on implants, aiming predictability and longevity. This selection must obey a reverse multidisciplinary planning for aesthetic and biomechanical success. This work aims to present an idealized technique to demystify the choice of prosthetic components on implants available in the market, helping the dentist to correctly select prosthetic abutments, as well as their indications and contraindications. The 5-fingers technique defines a prosthetic component to each finger and also to each finger a factor to be checked in this choice: interocclusal distance, periimplantar sulcus, angulation, isolated or multiple elements, cemented or bolted prosthesis. Thus allowing an objective and simple selection (AU).


Assuntos
Dente Suporte , Prótese Dentária , Prótese Dentária Fixada por Implante , Implantação Dentária , Odontólogos , Brasil , Planejamento de Prótese Dentária/métodos
8.
Prosthes. Lab. Sci. ; 5(18): 39-46, jan.-mar. 2016. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-853898

RESUMO

O estudo teve por objetivo avaliar a influência do comprimento do núcleo metálico fundido intrarradicular, bem como da férula em um incisivo central superior com variação de inserção óssea, através do método 3D de elementos finitos. Para tanto, um modelo de incisivo central superior foi reproduzido digitalmente simulando três fatores de variações, bem como suas interações, obtendo-se dezesseis modelos que apresentaram ou não a férula de 2 mm acima da linha de término, inserção óssea normal ou com perda de 3 mm em toda horizontal ou somente na vestibular e palatina. E, ainda, o comprimento do pino variando com 4 mm de guta percha preenchendo o canal ou 9,55 mm. Os modelos foram submetidos a tensões de tração através do software de simulação de elementos finitos Ansys Workbench V10. SP1 (Ansys Inc., Canonsburg, PA, USA). Os resultados mostraram que a presença da férula é responsável pela redução em quase 50% das tensões de tração quando comparado a modelos sem férula. A variação do comprimento do núcleo tem um pequeno efeito sobre a concentração das tensões de tração. Os níveis de tensões de tração mais elevados foram encontrados nos modelos onde havia perda óssea acentuada e nos casos sem presença de nível ósseo ao redor do núcleo. A presença da férula nos casos onde a perda óssea foi acentuada não interferiu significativamente nas tensões de tração, mostrando que a presença da férula é importante, mas não é suficiente para compensar o efeito que a perda óssea causa sobre o dente.


Assuntos
Dente Suporte , Análise de Elementos Finitos , Técnica para Retentor Intrarradicular , Tecnologia Odontológica , Fraturas dos Dentes
9.
Full dent. sci ; 5(19): 454-461, jul. 2014. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-726527

RESUMO

O tema seleção de pilares protéticos é, sem dúvida, um pré-requisito para o sucesso da reabilitação do paciente. Para se realizar um planejamento intelectual da seleção dos pilares protéticos ‚ fundamental conhecer as opções protéticas disponíveis e suas respectivas indicações e contraindicações. Entretanto, determinadas situações clínicas dificultam sua aplicação, devido ás limitações de certos componentes, …ás vezes estéticas, …ás vezes mecânicas. Com isso, vão sendo desenvolvidos novos componentes de acordo com as necessidades práticas, surgindo assim uma gama de pilares com o objetivo de facilitar a resolução de problemas clínicos. Este trabalho tem como finalidade demonstrar, através de um caso clínico, a importância do planejamento intelectual na seleção dos intermediários para se obter sucesso estético e mecânico em uma reabilitação metalocerâmica implantorretida parafusada com sistema tubo-parafuso, lateral ou transversal em implantes com inclinações vestibulares mantendo a reversibilidade


The selection of abutments is a requirement for a successful rehabilitation. To make an intellectual plan for the selection of prosthodontic abutment is extremely important to know the options available, as well as their indication and contraindication. However, some clinical situations may complicate its application, because of aesthetic or mechanical issues and other limitations of some components of the abutments. Therefore, new prosthodontics abutments are developed in order to meet practical needs and facilitate the solution of clinical issues. The present study aimed to present the importance of the intellectual plan for the selection of abutment in order to achieve aesthetic and mechanical success in a rehabilitation using metal ceramic screw retained implant, with lateral or transversal screw-tube system, in buccal angulation keeping the reversibility


Assuntos
Humanos , Estética Dentária , Implantes Dentários , Osseointegração/fisiologia , Próteses e Implantes , Prótese Dentária Fixada por Implante/métodos , Dente Suporte , Procedimentos Cirúrgicos Pré-Protéticos Bucais , Planejamento de Dentadura/métodos
10.
In. Carreiro, Adriana da Fonte Porto; Batista, André Ulisses Dantas. Prótese parcial removível contemporânea. São Paulo, Santos, 2013. p.15-24, ilus. (BR).
Monografia em Português | LILACS, BBO - Odontologia | ID: lil-708386
11.
In. Carreiro, Adriana da Fonte Porto; Batista, André Ulisses Dantas. Prótese parcial removível contemporânea. São Paulo, Santos, 2013. p.267-293, ilus. (BR).
Monografia em Português | LILACS, BBO - Odontologia | ID: lil-708396
12.
J. appl. oral sci ; 21(1): 20-24, 2013. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-684990

RESUMO

Although the use of zirconia abutments for implant-supported restorations has gained momentum with the increasing demand for esthetics, little informed design rationale has been developed to characterize their fatigue behavior under different clinical scenarios. However, to prevent the zirconia from fracturing, the use of a titanium connection in bi-component aesthetic abutments has been suggested. Objective: Mechanical testing of customized thin-walled titanium-zirconia abutments at the connection with the implant was performed in order to characterize the fatigue behavior and the failure modes for straight and angled abutments. Material and Methods: Twenty custom-made bi-component abutments were tested according to ISO 14801:2007 either at a straight or a 25° angle inclination (n=10 each group). Fatigue was conducted at 15 Hz for 5 million cycles in dry conditions at 20°C±5°C. Mean values and standard deviations were calculated for each group. All comparisons were performed by t-tests assuming unequal variances. The level of statistical significance was set at p≤0.05. Failed samples were inspected in a polarized-light and then in a scanning electron microscope. Results: Straight and angled abutments mean maximum load was 296.7 N and 1,145 N, the dynamic loading mean Fmax was 237.4 N and 240.7 N, respectively. No significant differences resulted between the straight and angled bi-component abutments in both static (p=0.253) and dynamic testing (p=0.135). A significant difference in the bending moment required for fracture was detected between the groups (p=0.01). Fractures in the angled group occurred mainly at the point of load application, whereas in the straight abutments, fractures were located coronally and close to the thinly designed areas at the cervical region. Conclusion: Angled or straight thin-walled zirconia abutments presented similar Fmax under fatigue testing despite the different bending moments required for fracture...


Assuntos
Humanos , Dente Suporte , Planejamento de Prótese Dentária , Materiais Dentários/química , Titânio/química , Zircônio/química , Implantes Dentários , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Estresse Mecânico
13.
Dent. press implantol ; 6(4): 93-103, oct.-dec. 2012. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-698315

RESUMO

A remodelação óssea cervical ao redor de implantes com plataforma convencional, conhecida como saucerização, pode comprometer a manutenção dos tecidos duros e moles peri-implantares, gerando comprometimentos estéticos como recessões e/ou perda de papilas. O conceito de plataforma switching, com o posicionamento da união implante-abutment mais internamente, aumentando o distanciamento entre o osso e a plataforma protética, parece minimizar ou impedir essa reabsorção óssea. O presente trabalho tem o objetivo de apresentar um relato de caso clínico de reabilitação estética anterior, com a utilização de um implante plataforma switching associado a recursos plásticos e protéticos peri-implantares que maximizassem o resultado final. Os resultados clínicos e radiográficos demonstraram preservação dos picos ósseos proximais e das papilas, manutenção da espessura de tecido mole e adequado resultado estético final. A escolha do uso de implantes com essas características de plataforma switching pode ser favorável em áreas estéticas.


Assuntos
Humanos , Feminino , Perda do Osso Alveolar , Implantação Dentária , Prótese Dentária , Remodelação Óssea , Dente Suporte , Estética Dentária
14.
Full dent. sci ; 2(5): 16-20, 20100815.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-850823

RESUMO

O desenvolvimento de abutments personalizados tornou-se uma alternativa para modelos de restaurações estéticas nos implantes. A confecção pode ser preparada em laboratório ou no consultório, diretamente na boca do paciente. Pilar personalizado Procera, Nobel Biocare, se baseia no sistema CAD-CAM e é projetado pelo computador e enviado nas especificações exatas obtidas no processo de digitalização. Por não haver período que precede a instalação do pilar protético, o abutment personalizado proporciona melhora na estética, com um aspecto similar ao dente natural promovendo integração social e conforto. Existem vantagens quando o complexo mucogengival é delgado e transparente, evitando sombras acinzentadas na região peri-implantar. A personalização dos pilares melhora a estética por simular mais corretamente a arquitetura gengival marginal ao redor do dente como também as condições de higienização


The development of custom abutments has become an alternative to models of aesthetic restorations on implants. The abutments can be prepared in the laboratory or in the office, inside the mouth. Custom abutment, launched by Nobel Biocare Procera, based on CAD-CAM system and is designed by computer and sent to make the exact specifications obtained in the scanning process. Because there is no period preceding the installation of the abutment, the abutment custom provides improvement in aesthetics, with an appearance similar to natural tooth promoting social integration and comfort. Also, it shows advantages when the mucus-gingival complex is thin and transparent gray shadows on the gums are then eliminated. Personalization improves the aesthetics of the pillars to simulate more accurately the marginal gingival architecture around the tooth as well as the conditions of hygiene


Assuntos
Dente Suporte , Implantes Dentários , Estética Dentária , Materiais Dentários/normas , Desenho Assistido por Computador/instrumentação , Zircônio
15.
Rev. dental press periodontia implantol ; 5(2): 103-110, abr.-jun. 2011.
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-616326

RESUMO

Após a divulgação do conceito de osseointegração por Brãnemark, baseado em anos de estudo, houve uma grande mudança na Odontologia moderna. Os tratamentos ganharam muitas variáveis no planejamento, normalmente mais estéticos e eficazes. Apesar da introdução dos implantes osseointegrados, com grande demanda e evolução da técnica, alguns fatores ainda limitam a colocação de um número adequado de implantes. Com isso, tem-se deparado com uma situação clínica de grande importância na Implantodontia: a restauração do edentulismo parcial utilizando pilares de dentes naturais unidos a implantes. O principal fator de preocupação ao se indicar a união dente/implante é a biomecânica, devido à diferença de absorção das forças oclusais pelos dois componentes distintos, dente e implante. Através de uma revisão de literatura, foram abordados os critérios biomecânicos dessa união, considerações sobre as formas de executá-la, as possíveis complicações e os achados clínicos das pesquisas. Embora os conceitos teóricos revelem problemas em potencial, os resultados clínicos apontam favoravelmente para o uso desse tipo de união. Segundo alguns profissionais, principalmente em segmentos curtos e com conexões rígidas, entretanto, o assunto é ainda bastante controverso.


After the popularization of the osseointegration concept from Branemark, based on years of study, there was a great turn in the modem dentistry. The treatments won many variation during prosthodontic planning related to aesthetics and efficacy. In spite of introduction of osseointegrated implants, technical developments and increase of indications, several factors still limit the use of an appropriate number of implants. With that, a critical situation in the Implantology: to use or not tooth-implant connection, and in using, what is the best way to do so. The main factor of relevance to indicate the tooth-implant connection is the biomechanics, due to the difference of absorption of the occlusal forces on the two different components, tooth and implant. Through literature review, the biomechanical criteria of this union, considerations of how to do it possible and the complications that could occur were discussed. Although the theoretical concepts reveal potentials problems, the clinical results appear favorable to the use of this type of union, mainly in short segments and with rigid connections.


Assuntos
Prótese Dentária , Retenção em Prótese Dentária , Implantes Dentários/métodos , Arcada Parcialmente Edêntula , Fenômenos Biomecânicos , Dente Suporte , Mandíbula , Maxila
16.
RSBO (Impr.) ; 8(1): 97-101, jan.-mar. 2011.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-874398

RESUMO

Introdução: A prótese parcial removível de extremidade livre unilateral ou bilateral apresenta complexa biomecânica. Seus movimentos em diversas direções, juntamente com a forma do rebordo alveolar e a resiliência da fibromucosa, podem levar a forças danosas sobre as estruturas de suporte. A associação entre implantes e prótese parcial removível visa proporcionar melhores propriedades mecânico-biológicas ao sistema estomatognático. Objetivo: Realizar uma revisão de literatura e discussão quanto ao uso dessa alternativa de reabilitação. Revisão de literatura e conclusão: Estudos têm evidenciado que essa associação oferece maior suporte, retenção e estabilidade às próteses, limitando seu movimento de aproximação em direção aos tecidos de suporte e propiciando conforto funcional e psicológico aos pacientes.


Introduction: Unilateral or bilateral distal-extension removable partial dentures present complex biomechanics. The movements in different directions, associated with the alveolar ridge shape and soft tissue resilience can lead to damaging forces on the supporting structures. The association between implants / removable partial denture aims to provide better mechanical and biological properties to the stomatognathic system. Objective: The aim of this paper was to review the articles about the effect of implant support on distal extension removable partial dentures. Literature review and conclusion: Studies have shown that this combination provides greater support, retention and stability to the prosthesis, thus limiting their approach movement toward supporting tissues and providing functional and psychological comfort to patients.


Assuntos
Humanos , Dente Suporte , Implantação Dentária , Prótese Parcial Removível
18.
Arq. odontol ; 47(3): 170-177, 2011. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-620889

RESUMO

O sucesso das próteses fixas adesivas está diretamente relacionado ao sistema adesivo utilizado e ao tipo de preparo realizado para obtenção de uma boa retenção. Essas próteses surgiram como uma alternativa protética, tendo em vista o baixo custo, o uso de uma técnica mais conservadora e a facilidade laboratorial. Este estudo objetivou discutir, por meio de uma revisão de literatura, as formas de preparo, os tipos de materiais e as vantagens e desvantagens do uso de próteses fixas adesivas. Dentre as principais vantagens, destaca-se a conservação da estrutura dentária e como desvantagem, a limitação da estética devido à possibilidade do aparecimento da liga metálica. O desenho do preparo, o tipo de cimento e o tipo de liga, bem como o tratamento de superfície são alguns dos fatores que podem influenciar na longevidade do manuseio desse tipo de prótese. O tratamento com próteses fixas adesivas tem grande potencial na conservação dos dentes pilares e também um percentual significativo de sucesso.


Assuntos
Humanos , Masculino , Feminino , Preparo Prostodôntico do Dente , Prótese Adesiva/tendências , Dente Suporte/tendências
19.
Braz. j. oral sci ; 9(1): 11-15, Jan.-Mar. 2010. ilus, tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-578039

RESUMO

Aim: To evaluate the occurrence of microstrain around morse taper implants in straight configuration under axial load in a cast monoblock framework. Methods: Three implants were inserted in a polyurethane block and microunit abutments were installed on the implants with 20 Ncm torque. Plastic and machined copings were adapted on the preset waxing to fabricate the framework (n=5). Four strain gauges were attached on the upper surface of the block and then each framework was tightened on the abutments and a vertical load of 30 kg was applied to five points of the framework. Results: The data obtained in the strain gauge analysis were subjected to twoway ANOVA and Tukey’s test (=0.05). There was statistically significant difference (p=0.0222) for the factor application point and the mean microstrain values were: application point B 402,04µ, point A 401.21µ, point E 390.44µ, point D 341.76µand point C 309.19 µ. Conclusions: There was no microstrain difference between plastic and machined copings during axial loading. Difference in the application point was observed, but remained within bone physiological limits.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Prótese Parcial Fixa , Análise de Variância , Dente Suporte , Teste de Materiais , Estresse Mecânico
20.
ImplantNews ; 7(6): 837-844, 2010. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-599217

RESUMO

Abutment, também denominado pilar de fixação, é um material metálico ou cerâmico, instalado acima de um implante que provê suporte para próteses dentais. O sucesso significativo destas aumentou a demanda por melhores resultados estéticos e consequentemente resulta em pesquisas para o desenvolvimento de novos componentes, materiais e conceitos de tratamento. Atualmente, os implantes mais utilizados são aqueles a base de titânio e os abutments, que também eram fabricados com materiais metálicos, estão sendo substituídos por materiais cerâmicos como alumina e zircônia estabilizada com ítria. O presente estudo propôs-se avaliar as propriedades mecânicas de pilares cerâmicos estéticos a base de compósitos alumina-zircônia (Al2O3-ZrO2) e zircônia estabilizada (ZrO2 Y-TZP), através de ensaios mecânicos, a fim de verificar sua viabilidade de produção e comercialização para utilização em procedimentos odontológicos em reabilitação oral. Para tanto, obteve-se pilares cerâmicos a base de compósitos de ZrO2 e Al2O3-ZrO2 e submeteu-os a ensaios mecânicos de fadiga cíclica úmida e carregamento por compressão tangencial. Os resultados foram avaliados por meio de avaliações macroscópicas dos corpos de prova, sobrevida de ciclos e valores de resistência à fratura. Dentro das condições experimentais, os resultados obtidos demonstraram que há possibilidade de se obter pilares de ZrO2 e Al2O3-ZrO2, usinados industrialmente, com elevada resistência mecânica e durabilidade clínica quando corretamente instalados baseado em um planejamento minucioso. Apesar da realização dos ensaios em associação, cuja finalidade foi de se aproximar das condições in vivo, os ensaios laboratoriais apresentam limitações, como os vários tipos de forças intraorais.


An abutment is a metallic or ceramic material installed onto the implant providing support for fixed dental prosthesis. The significant success these dental restorations increased patient demand for better esthetic results, which resulted in research to develop new components, materials and treatment concepts. Currently, the most widely used implants are those based on titanium; the abutments, which were also made of metallic materials, are being replaced by ceramic materials such as alumina and yttrium-stabilized zirconia (ZrO2 Y-TZP). The purpose of this study is to evaluate the mechanical properties of ceramic abutments on the aesthetic composite alumina-zirconia (Al2O3-ZrO2) and stabilized zirconia (ZrO2 Y-TZP) by mechanical tests to verify its feasibility and production marketing for use in dental procedures. The abutments ceramic composites of ZrO2 and Al2O3-ZrO2 were submitted to mechanical tests of wet cyclic fatigue and loading by tangential compression. The results were evaluated by macroscopic evaluations of the specimens, survival after cycling and values of fracture resistance. Within the experimental conditions, the results showed that is possible to produce industrially abutments of ZrO2 and Al2O3-ZrO2 with high mechanical strength and clinic success when properly installed, based on careful planning. Although tests were applied to approach in vivo conditions, there are limitations such as several intra-oral forces.


Assuntos
Dente Suporte , Implantes Dentários , Estética Dentária , Ciência dos Materiais