Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros










Filtros aplicados
Intervalo de ano de publicação
1.
Ortho Sci., Orthod. sci. pract ; 16(61): 44-55, 2023. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-1509244

RESUMO

Resumo Proposição: avaliar in vitro a rugosidade superficial de fios ortodônticos antes e após a compressão com pinças ortodônticas. Material E Métodos: 30 fios 0,014" de níckel-titânio termoativados (Neosentalloy, GAC) e 30 fios 0,019 x 0,025" de aço foram usados nos experimentos. Avaliou-se a rugosidade superficial com rugosímetro (NewViewTM 7100, Zygo), antes e após a compressão com alicate Weingart do lado esquerdo e pinça Mathieu do lado direito (Dentaurum). Foram determinados os parâmetros de rugosidade Ra (µm), Rq (µm), PV (µm), Srmax Iso (nm). Testes estat´siticos Wilcoxon foram realizados para analisar a variação dos parâmetros da rugosidade com nível de confiança de 95% e p<0,05. Resultados: Os fios redondos de NiTi apresentaram diferenças significaticas dos parâmetros Ra e Rq antes e após a compressão com pinça Mathieu. O emprego do alicate Weingart não alterou a rugosidade dos fios redondos. Os fios retangulares apresentaram diferenças significativas em todos os parâmetros com uso das duas pinças. As médias das diferenças dos parâmetros entre o alicate Weingart e a pinça Mathieu nos fios redondos, não foram estatisticamente significativos. Os fios retangulares apresentaram maior rugosidade com o emprego do alicate Weingart, com diferenças significativas. Conclusão: O uso do alicate tipo Weingart e da pinça tipo Mathieu aumentam a rugosidade dos fios de NiTi e de aço (AU)


Abstract Proposition: the surface roughness of orthodontic wires was evaluated in vitro before and after gripping with two different orthodontic pliers. Material And Methods: Units were made of 30 round heat-activated Nickel Titanium alloy wires 0,014" (Neosentalloy, GAC), and another group with 30 rectangular steel wires 0,019 x 0,025". The surface roughness was evaluated with a rugosimeter (NewViewTM 7100, Zygo), before and after gripping with Weingart plier on the left side and Mathieu plier on the right side (Dentaurum), in addition to the average difference in roughness between groups of the same types of wires with parameters Ra (µm), Rq (µm), PV (µm), Srmax Iso (nm). The variation of parameters with different clamps was evaluated (Wilcoxon test); different alloys by the same clamp, 95% confidence level and p<0.05. Results: The round wires showed significant differences (Ra and Rq) before and after being gripped with Mathieu plier. The roughness was higher after being gripped. Weingart pliers and round wires obtained the same results, with greater roughness after being clamped. Rectangular wires showed significant differences in all parameters, with both clamps. The means of the differences in the parameters between the Weingart pliers and the Mathieu forceps on the round wires were not statistically significant. In the rectangular wire, the values between the tweezers showed greater roughness with the grip of the Weingart pliers, with significant differences.Conclusion: After securing the orthodontic wires, the Weingart pliers and the Mathieu tweezers increased the roughness parameters (AU)


Assuntos
Fios Ortodônticos , Instrumentos Cirúrgicos , Estatísticas não Paramétricas , Atrito Dentário
2.
Prosthes. Esthet. Sci ; 7(27): 19-24, abr.-jun. 2018. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-906903

RESUMO

Este artigo descreve o passo a passo e a sequência clínica de instalação do clipe sobre a barra de sobredentaduras, utilizando o sistema Straumann®.


This article describes step by step and the clinical installation sequence of a bar-clip overdenture, using the Straumann® Dental Implant System.


Assuntos
Implantes Dentários , Falha de Restauração Dentária , Implantação Dentária , Revestimento de Dentadura , Instrumentos Cirúrgicos/estatística & dados numéricos
3.
São José dos Campos; s.n; 2014. 79 p. ilus, tab, graf.
Tese em Português | BBO - Odontologia | ID: biblio-867582

RESUMO

O bisturi harmônico Harmonic® foi introduzido na prática cirúrgica há mais de uma década, com o intuito de minimizar os riscos das tecnologias eletro-cirúrgicas, dano energético local e/ou periférico, além de complicações associadas a energia monopolar. Tem como característica a conversão da energia elétrica em energia mecânica, levando a lâmina ativa à vibração de 55.500 Hz por segundo produzindo um aquecimento secundário, que promove a formação de um coágulo adesivo enquanto corta, selando veias e vasos linfáticos de até 5 mm de diâmetro. Contribui com a diminuição do tempo de cirurgia, perda sanguínea e dor pós-operatória, com temperaturas inferiores quando comparado com bisturi elétrico e lasers de alta potência. Tendo em vista as diversas vantagens atribuídas ao bisturi harmônico e a escassez de literatura concernente, julgou-se necessário um estudo que avalie os parâmetros na reparação tecidual do tratamento cirúrgico com bisturi harmônico Harmônic® quando comparado com o convencional, levando-se em consideração os estágios da reparação tecidual na língua. Para isso, foi realizada indução a necrose em borda lateral de língua em 18 ratos, divididos em 2 grupos para remoção cirúrgica da lesão com bisturi harmônico Harmônic® e bisturi convencional. Tomadas as medidas pós-operatórias, 3 ratos por grupo foram sacrificados em 7, 14 e 28 dias e submetidos às análises macroscópica e microscópica. Apesar das diferenças clínicas e histológicas observadas nos tempos iniciais, ao final, a qualidade do processo de reparo foi semelhante em ambos os grupos


The Harmonic® scalpel (HS) was shown in surgical practice for more than a decade, with the aim of minimizing the risks of electro-surgical technologies, local energy damage and/or peripheral, in addition to complications associated with monopolar energy. Characterize by the conversion of electrical energy into mechanical energy leading to active blade vibration of 55,500 Hz per second producing a secondary heating which promotes the formation of a blood clot while cutting, adhesive sealing veins and lymphatic vessels of up to 5 mm in diameter. Contributes to the reduction of the time of surgery, postoperative pain and blood loss with lower temperatures when compared to electric scalpel and high-power lasers radiation. Considering the several advantages attributed to HS and the paucity of literature regarding was de emed necessary a study that evaluates the parameters on tissue repair of surgical treatment with HS when compared with the conventional scalpel (CS), taking into account the stages of tissue repair in the tongue. For that a necrosis induction of lateral border of tongue was held in 18 rats divided into 2 groups for surgical removal of the lesion with HS and CS. Three rats per group were sacrificed at 7, 14 and 28 days and subjected to macroscopic and microscopic analyses. Despite the clinical and histological differences observed in early times and in the end, the quality of the repair process was similar in both groups


Assuntos
Humanos , Língua/patologia , Cirurgia Bucal , Terapia a Laser , Instrumentos Cirúrgicos
4.
São Paulo; s.n; 2013. 54 p. ilus, tab, graf. (BR).
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-867041

RESUMO

O objetivo deste estudo foi avaliar histomorfometricamente a influência da piezocirurgia (PZ) sobre a reparação óssea ao redor de implantes de titânio. Foram utilizados 15 ratos machos Wistar, com aproximadamente 300g, nos quais em uma das patas o leito para instalação de um implante de titânio foi realizado com um motor rotatório convencional (Grupo Controle) e na outra com ultrassom cirúrgico piezoelétrico (Grupo Piezo). Após 30 dias, os animais foram sacrificados para obtenção do material para análise histológica. Foram avaliados os seguintes parâmetros histomorfométricos (em porcentagem), separadamente, para a região cortical e medular: a proporção de tecido mineralizado (PTM) na região adjacente ao implante (500m adjacentes); área de tecido mineralizado (AO) dentro dos limites das roscas do implante; e a extensão de tecido ósseo em contato direto (CD) com a superfície do implante. Os resultados deste estudo mostraram que não foram observadas diferenças para CD na região medular (p>0,05) e para PTM na região cortical (p>0,05). Por outro lado, um maior preenchimento das roscas foi observado quando utilizou-se a PZ tanto na região cortical (71,50 + 6,91 e 78,28 + 4,38; média + dp para os grupos Controle e Piezo; respectivamente p<0,05) quanto na região medular (9,62 + 4,06 e 19,94 + 14,18; média + dp para os grupos Controle e Piezo; respectivamente p<0,05)


Resultados semelhantes foram observados para o parâmetro PTM na região medular (9,35 + 5,54 e 18,72 + 13,21; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Já a técnica convencional foi superior à PZ em relação a CD na região cortical (80,42 + 10,88 e 70,25 + 16,93; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Dentro dos limites do presente estudo, pode-se concluir que a piezocirurgia apresenta-se como uma alternativa viável no preparo de leito para instalação de implantes de titânio


The aim of this study was to investigate the influence of two techniques of dental implant site preparation on bone healing around titanium dental implants. Fifteen male Wistar rats (+ 300g) were used in the study. In each rat tibiae was randomly assigned to receive the implant site preparation with a conventional drilling technique (Control) or with piezoelectric device (Piezo). After thirty days the animals were sacrificed and then the following histomorphometric parameters were evaluated (in percentage) separately to cortical and cancellous regions: Proportion of mineralized tissue (PMT) adjacent to implant threads (500um adjacent); bone area within the threads (BA); and bone-implant contact (BIC). The results demonstrated that there were no differences between the two groups for cancellous BIC (p>0.05) and cortical PTM (p>0.05). Meanwhile, a higher percentage of BA was observed in PIEZO group in the cortical (71,50 + 6,91 and 78,28 + 4,38; mean + stdev for groups Control and Piezo; respectively p<0.05) and cancellous regions (9,62 + 4,06 and 19,94 + 14,18; mean + stdev for groups Control and Piezo; respectively p<0.05)


The piezosurgery also showed higher PTM values in the cancellous zone (9,35 + 5,54 and 18,72 + 13,21; mean + stdev for groups Control and Piezo; respectively p<0.05). However, Control presented better results for BIC in cortical region (80,42 + 10,88 and 70,25 + 16,93; mean + stdev for groups CTRL and PIEZO; respectively p<0.05). Within the limits of the present study, it can be concluded that piezosurgery is a feasible alternative in implant site preparation


Assuntos
Animais , Ratos , /métodos , Implantação Dentária/métodos , Instrumentos Cirúrgicos , Instrumentos Odontológicos , Osseointegração/fisiologia , Osteotomia/métodos
5.
ImplantNews ; 10(4): 428-436, 2013. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-694444

RESUMO

A fresagem óssea para instalação de implante é um procedimento de alta precisão, onde o planejamento adequado e a atenção aos detalhes são fundamentais para o sucesso do procedimento cirúrgico, principalmente quando executada próxima a áreas nobres, como o nervo alveolar inferior. Esta situação tornou-se mais frequente, devido à utilização dos implantes curtos. Durante a cirurgia, a mistura de soro, saliva e sangue, associados à localização do implante a ser instalado e à velocidade de rotação da fresa pode, mesmo com as melhores condições de iluminação, pode ser difícil saber quando uma determinada profundidade foi atingida. O objetivo neste trabalho foi avaliar o uso do stopper pelos dentistas, por meio de questionário, analisando sua necessidade, dificuldades, praticidade, rapidez e segurança de seu uso, considerando as motivações para o uso ou não deste dispositivo. Foi elaborado um questionário com dez questões e aplicado a 128 profissionais que executam cirurgia para instalação de implantes sem prévia orientação sobre o assunto. Os dados foram submetidos à análise descritiva com resultados em números absolutos e porcentagens. Nos resultados, 20,3% dos profissionais relataram que já tiveram histórico de parestesia do nervo alveolar inferior devido à fresagem, 58,5% nunca usaram nenhum tipo de dispositivo limitador de profundidade e 17,5% dos profissionais relataram desconhecer o dispositivo. Pôde-se concluir que, embora os profissionais tenham a percepção de que o stopper de fresas é um acessório importante durante a cirurgia, a sua utilização é pouco difundida, o que pode estar associado aos altos índices de complicações relatados neste estudo.


Bone drilling for installation of implant is a procedure of high accuracy in which the proper planning and attention to details are key to the success of the surgical procedure, especially when drilling is done next to noble structures as the inferior alveolar nerve. This situation is becoming increasingly frequent due the increased use of short implants. During the surgery, the mixture of saline solution, saliva and blood, associated with the location of the implant to be installed and cutter rotational speed, can even under the best lighting conditions make it difficult to know exactly when a given depth. The objective of this study was to evaluate the use of stopper by dentists through the questionnaire, analyzing your needs, difficulties, convenience, speed and safety of its use, considering what the motivations for use of this device or not. A questionnaire was developed consisting of ten questions and applied to 128 practitioners who perform surgery to implant placement without prior guidance on the subject. The data were submitted to descriptive analysis of absolute numbers and percentages. In the results reported that surgeons had 20.3% cases of inferior alveolar nerve paresthesia due to milling, 58.5% never used any kind of depth limiting device and 17.5% of professionals reported that do not know the device. It can be concluded that although professionals have the perception that the stopper is a drill accessory important during surgery, their use is not very wide spread, which may be associated with high complication rates reported in this study.


Assuntos
Implantes Dentários , Complicações Intraoperatórias , Instrumentos Cirúrgicos
6.
Rev. Assoc. Paul. Cir. Dent ; 66(2): 147-150, abr.-jun. 2012. ilus, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-667466

RESUMO

A fresagem óssea em implantodontia é um evento que demanda muito cuidado no que diz respeito ao controle da elevação da temperatura. Através da instalação de termopares, foram mensuradas as temperaturas máximas atingidas no osso medular e no osso cortical de fêmur bovino durante osteotomias para instalação de implantes osseointegrados. Foram realizadas 32 perfurações com profundidade de 15 mm, velocidade rotacional da broca em 1.200 rpm, torque de 35 N, carga de 2 Kg e brocas helicoidais de 2,0 mm de diâmetro. Para medir a temperatura do osso foram utilizados dois termopares tipo K acoplados a um termômetro digital portátil, sendo um na cortical óssea a 3 mm de profundidade (termopar 1), e o segundo a 15 mm de profundidade, no tecido ósseo medular (terrnopar 2). Em metade das perfurações foi utilizada a técnica de dupla irrigação que permite, além da irrigação externa ao osso, a passagem do líquido irrigante pelo interior da broca. Nas outras 16 perfurações foram utilizadas apenas a irrigação externa a fim de diminuir o calor gerado durante o preparo do local de instalação do implante. Os resultados comprovam que o aumento maior da temperatura está no osso cortical apesar da profundidade da perfuração e que, em comparação com a irrigação externa, a dupla irrigação é mais eficiente no controle do aquecimento durante as osteotomias, diminuindo o risco de superaquecimento e consequentes injúrias ósseas.


The drilling bone in implantology is an event that demands a lot of care with respect to the control of tem peratu re i ncrease. By usi ng thermocou pies, the h ig hest tem peratu res reached in medular and cortical bones of bovine femur were measured during osteotomies to install osseointegrated implants. It was performed 32 perforations with rotational speed of the drill in 1200 rpm, 15 mm of depth, 35 N torque, 2 Kg-Ioad and helicoid drills with 2 mm of diameter. To measure the temperature of the bone were used two type K thermocouples attached to a portable digital thermometer, and a cortical bone 3 mm in depth (thermocouple 1). and the second 15 mm deep in the bone marrow (thermocouple 2). In half of the total number of the perforations it was used the double-irrigation technique which promotes the externa I irrigation and also allows flowing of irrigating solution inside the drill. In the other 16 perforations it was used only the external irrigation to reduce the heat generated during the perforation. The results prove that temperature increases most in the cortical bone despite the perforation depth and in comparison with the external irrigation only, the double-irrigation technique is more efficient to control the heating during osteotomies decreasing the risk of overheating and consequent bone injuries.


Assuntos
Animais , Bovinos , Implantação Dentária/métodos , Osseointegração , Osteotomia , Temperatura Extrema , Instrumentos Cirúrgicos
7.
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-618563

RESUMO

O aço inoxidável é um dos principais materiais empregados na fabricação de instrumentais cirúrgicos devido à combinação de propriedades mecânicas adequadas e elevada resistência à corrosão. Apesar de apresentar uma resistência à corrosão superior à maioria dos metais, em meios muito agressivos os aços inoxidáveis podem sofrer algum tipo de corrosão, podendo prejudicar de alguma forma sua durabilidade ou aparência. Este trabalho apresenta características e resultados de ensaios realizados em um cisalhador de placas de titânio com propósito de avaliar a resistência à corrosão do aço inoxidável M340. O objetivo principal deste estudo é determinar as resistências à esterilização em autoclave, à corrosão e à exposição térmica dos instrumentais cirúrgicos (cisalhador de placas de titânio) fabricadas em aço inoxidável.


tainless steel is one of the main materials used in the manufacture of surgical instruments through the combination of mechanical properties and high corrosion resistance. Despite presenting a corrosion resistance superior to most metals in very aggressive media stainless steels can suffer some type of corrosion, may somehow undermine their durability or appearance. This paper presents features and results of tests on a shear of titanium plates with purpose of evaluating the corrosion resistance of stainless steel M340. The main objective of this study is to determine the resistance to autoclaving, corrosion and thermal exposure of the surgical instruments (shear titanium plates) made of stainless steel.


Assuntos
Implantes Dentários , Aço Inoxidável , Instrumentos Cirúrgicos
8.
ImplantNews ; 4(1): 45-49, jan.-fev. 2007. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-461748

RESUMO

O objetivo nessa pesquisa foi comparar e eficiência de corte de duas brocas para implantes, de formatos iguais e recobrimentos de superfície diferentes ((B1) com e (B2) sem recobrimento de nitreto de titânio). Para isso, foram utilizadas amostras de osso cortical de fêmur bovino, nas quais foram feitas perfurações (testes “cegos”) por 50 operadores. O teste foi conduzido com velocidade de 1500 rpm e irrigação constante de soro fisiológico. Foram registradas as forças exercidas e o tempo despendido durante perfurações ósseas, comparando seu desempenho entre os diferentes operadores. Os resultados foram submetidos a um teste estatístico de análise de variância Anova e seguidos pelo teste de Tukey 5%. O valor médio de tempo máximo despendido durante a perfuração com a B1(T1= 36,58 s) diferiu do tempo da B2 (T2= 22,2 s)e o valor médio de pressão máxima exercida durante a perfuração com a B1 (P1 = 3,55 kg) diferiu da pressão máxima da B2 (P2 = 3,264 kg). Pode-se concluir que a broca sem o recobrimento de nitreto de titânio apresentou comportamento mais favorável, requerendo menor pressão e menos tempo de perfuração.


Assuntos
Animais , Bovinos , Implantação Dentária Endóssea , Instrumentos Odontológicos , Procedimentos Cirúrgicos Bucais , Instrumentos Cirúrgicos , Titânio , Análise de Variância
9.
ImplantNews ; 3(3): 236-241, maio-jun. 2006. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-457395

RESUMO

Limitações anatômicas quantitativas e qualitativas do tecido ósseo, bem como reabsorçõesdiversas, limitam a realição dos procedimentos cirúrgicosna implantodontia. O formato do rebordo reabsorvido com conseqüente instalação de implantes com inclinações inadequadas, muitas vezes, resulta no comprometimento doperfil de emergência do transmucoso interferindo na resolução estética e biomecânica da prótese. Além disso , o alto grau de exig~encia estética dos pacientes e profissionais, o tempo, a morbilidade e o custo do tratamanto passaram a ter utualmente um grau de relevância muito maior. Assim sendo, a busca para as soluções de alta qualidade em espaço de tempo cada vez menos tornou-se fundamental. Cirurgias reconstrutivas como o enxerto ósseo t~em sido indicadas como alternativa para compensar essas limitações. Embasada na literatura científica a abordagem cirúrgica simultânea de reconstrução de áreas com defeitos ósseos e a colocaçãode implantes tornou-se uma alternativa terapêutica eficaz quando utilizada de forma criteriosa. esse estudo tem como objetivo relatar uma técnica cirúrgica alternativa de colocação de implante e a correção simultânea de uma área com defeito ósseo.


Assuntos
Humanos , Feminino , Transplante Ósseo , Implantação Dentária Endóssea , Implantes Dentários para Um Único Dente , Osteogênese por Distração , Colágeno , Estética Dentária , Osseointegração , Instrumentos Cirúrgicos
10.
ImplantNews ; 3(3): 257-260, maio-jun. 2006. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-457398

RESUMO

Apesar da reabilitação de pacientes parcial e totalmente edêntulos com implantes osseointegrados ser clinicamente aceitável na Odontologia moderna, muitas falhas ainda podem ocorrer nesse tipo de tratamento protético. Freqüentemente o afrouxamento e fratura dos parafusos de fixação e/ou retenção dos componentes dos implantes serve como um sinal de alerta, indicando que o sistema de conexões necessita de uma reavaliação. Assim, a proposta deste trabalho foi relatar a situação clínica da fratura de um parafuso de fixação e a técnica de remoção do fragmento no interior do implante.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Implantação Dentária Endóssea , Instrumentos Odontológicos , Falha de Restauração Dentária , Instrumentos Cirúrgicos , Fenômenos Biomecânicos
11.
ImplantNews ; 3(1): 30-35, jan.-fev. 2006. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-457347

RESUMO

As fixações zigomáticas (FZs) são alternativas às reconstruções por enxertos autógenos extrabucais no tratamento das maxilas atróficas. este artigo propôe um modificação no protocolo original para a instalação destas fixações.


Assuntos
Humanos , Cirurgia Bucal/métodos , Implantação Dentária Endóssea , Seio Maxilar/cirurgia , Zigoma/cirurgia , Materiais Dentários , Instrumentos Cirúrgicos
12.
Ciênc. odontol. bras ; 8(4): 56-67, out.-dez. 2005. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-850681

RESUMO

Avaliou-se neste estudo, a temperatura gerada durante o preparo do tecido ósseo comparando-se brocas de três sistemas de implantes: Conexão, Nobel e 3i. As perfurações foram feitas em osso cortical de fêmur bovino, com brocas de 2,0 e 3,0mm de diâmetro, até a profundidade de 13mm, a uma velocidade de 1500 rpm com pressão intermitente de 2kg e sob constante irrigação de soro fisiológico 0,9% a temperatura ambiente (24 ±1o C). As amostras foram mantidas em água a 36±1o C durante as perfurações. As temperaturas foram medidas com termopares inseridos no osso a 1mm da perfuração, em profundidades de 5 e 13mm e registradas com o auxílio de um coletor de dados conectado a um computador. Os dados de temperatura foram analisados pelo teste RM ANOVA (3 fatores). A profundidade foi o fator repetido. As análises foram seguidas pelo teste de Tukey (5%). Os resultados indicaram que a melhor condição experimental foi obtida para a broca Conexão de diâmetro 2mm na profundidade de 5mm (36,10±0,52oC) e a condição menos favorável foi para a broca Nobel de diâmetro 2mm na profundidade de 13mm (38,84±1,15oC). Concluiu-se que os maiores valores de temperatura foram obtidos para a profundidade de 13mm, independentemente do tipo de broca. O aumento do diâmetro induziu uma diminuição da temperatura para as brocas 3i e Nobel e um aumento para as brocas Conexão. Nenhuma temperatura registrada excedeu o limite biológico.


Assuntos
Animais , Bovinos , Calorimetria , Instrumentos Odontológicos , Temperatura Alta , /instrumentação , Osseointegração , Implantes Dentários , Microanálise por Sonda Eletrônica , Microscopia Eletrônica de Varredura , Instrumentos Cirúrgicos
13.
Rev. Odontol. Araçatuba (Impr.) ; 26(1): 73-77, 2005. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-856750

RESUMO

Os autores estudaram o comprimento das hastes dos fórceps e sua compatibilidade com a mão do usuário. A amostra foi composta por 160 graduandos da Faculdade de Odontologia de Araçatuba - UNESP. A mensuração da largura e comprimento foi realizada e os dados obtidos foram empregados para planificar as dimensões da mão. Os valores foram tratados estatisticamente empregando o teste t-Student e a descrição demonstrativa. O comprimento ideal da haste foi determinado multiplicando-se o comprimento da mão pela raiz quadrada de dois e dividindo esse resultado por dois. Concluiram que: a) existe diferença estatisticamente significante entre o comprimento da mão masculina e feminina; b) aproximadamente 50% dos alunos avaliados apresentam dificuldades para manusear o fórceps com haste com 12 cm de comprimento; c) é necessário adequar o comprimento das hastes dos fórceps para usuários com mãos pequenas


Assuntos
Cirurgia Bucal , Instrumentos Cirúrgicos , Extração Dentária
14.
Rev. bras. odontol ; 61(2): 80-83, abr.-maio 2004. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-405677

RESUMO

Nesta revisão, os autores tecem comentários sobre as vantagens da microcirurgia com abordagem microinvasiva e relatam um instrumento auxiliar na osteotomia: um cinzel ultra-sônico e um par de curetas ultra-sônicas, que permitem não só uma osteotomia restrita como também a coleta do osso, ajudando na regeneração óssea e permitindo uma curetagem mais rápida e acurada, para melhor orientar o profissional quando esse tipo de procedimento for indicado


Assuntos
Endodontia , Microcirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Osteotomia , Instrumentos Cirúrgicos
17.
Rev. odonto ciênc ; 16(32): 7-16, jan.-abr. 2001. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-308147

RESUMO

O objetivo deste trabalho foi avaliar, in vitro, a resistência à traçäo proporcionada por 1 e por 2 clipes conectados a uma barra cilíndrica, simulando a capacidade retentiva de uma overdenture. Foram utilizados 30 clipes em liga de ouro e 20 barras também em liga de ouro da NOBEL BIOCARE - Säo Paulo, Brasil. Foram confeccionados 10 corpos-de-prova compostos por 2 clipes e uma barra cilíndrica. A barra que compöe o corpo-de-prova mede 1,96mm de diâmetro por 15mm de comprimento. Os corpos-de-prova foram submetidos a um teste de resistência à traçäo, totalizando 6000 traçöes, em uma máquina de ensaio universal EMIC DL-2000 com velocidade de 50mm por minuto. As médias de resistência à traçäo foram: 1 clipe 7,47N, 2 clipes 14,36N. Os resultados foram submetidos ao tratamento estatístico pela Análise de Variância (ANOVA) e pelo teste t-student ao nível de significância de 1 por cento. Foi possível concluir que, na comparaçäo entre as médias obtidas após os ensaios de resistência à traçäo de 1 e 2 clipes, a média geral obtida por 2 clipes foi superior à média geral obtida por um clip (p= 0.01). Na análise comparativa entre os diferentes níveis de traçäo com 1 e 2 clipes, observa-se que, em todos os níveis, as médias de resistência à traçäo säo superiores nos corpos-de-prova de 2 clipes. Os corpos-de-prova compostos por 2 clipes mantiveram sua capacidade de retençäo estável após as 50 traçöes iniciais; enquanto que os corpos-de-prova compostos por um clipe, após as 50 traçöes iniciais continuaram perdendo capacidade de retençäo ao longo dos ensaios. Os corpos-de-prova compostos por 2 clipes apresentaram diferença estatística significate do nível 1 (50 traçöes iniciais) para os demais níveis, que diferiram entre si. Os corpos-de-prova compostos por 1 clip näo apresentaram diferença estatística significante entre os diferentes níveis de traçäo


Assuntos
Ligas de Ouro , Instrumentos Cirúrgicos , Técnicas In Vitro , Prótese Total , Retenção em Prótese Dentária
19.
RPG rev. pos-grad ; 6(4): 346-53, out.-dez. 1999. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-298243

RESUMO

O objetivo desta pesquisa foi obter uma mensuraçäo acurada do trabalho mecânico desenvolvido pela lâmina de elevadores de Seldin angulados, de números IR e IL, portadores de dimensöes e procedências diferentes, frente a uma resistência padronizada, e procurar relacionar as variaçöes do trabalho mecânico com as dimensöes geométricas da lâmina do instrumento cirúrgico. Vinte e seis elevadores dentais - quatro americanos, quatro alemäes e dezoito nacionais, de três marcas diferentes - foram submetidos a um dispositivo de ensaio de elevadores (DEE). Após a colocaçäo do modelo da arcada dentária mandibular no DEE, posicionamos a ponta da lâmina do elevador no espaço existente entre a raiz de resina e o modelo suporte e acionamos a manivela do DEE, imprimindo um movimento de rotaçäo na lâmina do elevador, que resulta no desalojamento da raiz. Os registros gráficos da força e do deslocamento angular permitiram-nos calcular o trabalho mecânico. Os valores médios do trabalho mecânico em joules desencadeado pela açäo da lâmina de elevadores angulados de Seldin, de números IR e IL, permitiram-nos concluir que existem variaçöes do trabalho mecânico presente na lâmina desses elevadores, que pela procedência diversificada apresentam diferentes dimensöes, sendo os elevadores alemäes e nacionais B os que apresentaram diferenças altamente significantes (teste Mann-Whitney) p < 0,01. Os elevadores alemäes foram os mais precisos (p < 0,01), e os americanos, os que apresentaram maior variabilidade que os nacionais B e C. Näo foi encontrada correlaçäo matemática evidente entre as variaçöes de trabalho mecânico e as dimensöes principais das lâminas


Assuntos
Extração Dentária/instrumentação , Instrumentos Cirúrgicos , Fenômenos Biomecânicos , Engenharia Biomédica , Instrumentos Odontológicos
20.
Rev. bras. odontol ; 55(5): 293-6, set.-out. 1998. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-230293

RESUMO

Avaliou-se a capacidade de vedamento da regiäo cervical intracanal de três materiais: cimento fosfato de zinco, cimento de ionômero de vidro e cimento endodôntico Sealer 26 associado a cones de guta-percha usados na confecçäo do tampäo cervical, durante o clareamento intracoronário. Os melhores resultados foram apresentados pelo cimento endodôntico Sealer 26 + guta-percha, seguido pelo cimento de ionômero de vidro. O cimento fosfato de zinco comportou-se, estatisticamente, semelhante ao grupo controle, isto é, com precárias propriedade seladoras


Assuntos
Humanos , Adulto , Raiz Dentária , Reabsorção da Raiz , Instrumentos Cirúrgicos , Clareamento Dental/efeitos adversos , Dente Canino , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Guta-Percha , Cimento de Fosfato de Zinco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...