Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros










Filtros aplicados
Intervalo de ano de publicação
1.
Braz. dent. sci ; 26(1): 1-9, 2023. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1411424

RESUMO

Objective: Evaluate the mechanical properties of experimental adhesive models with different photoinitiators (PI) polymerized by LED units of different power densities. Material and Methods: Three groups of adhesive models based on HEMA/BisGMA (45/55) were prepared in association with different PI combinations: G2 (control) ­ 2 PI: 0.5% CQ, 0.5% EDMAB; G3 - 3 PI: 0.5% CQ; 0.5% DMAEMA, 0.5% DPIHP; G4 - 4 PI: 0.5% CQ; 0.5% EDMAB; 0.5% DMAEMA; 0.5% DPIHP. The three formulations were polymerized at two different LED power densities: 550 mW/cm2 and 1200 mW/cm2. The degree of conversion (DC) of adhesive monomers was monitored in situ through the FTIR for 600 s. Specimens were prepared for each formulation for analysis mong adhesive systems (G2

Objetivo: Avaliar as propriedades mecânicas de modelos adesivos experimentais com diferentes fotoiniciadores (PI) polimerizados por unidades de LED de diferentes densidades de energia. Material e Métodos: Três grupos de modelos adesivos baseados em HEMA/BisGMA (45/55) foram preparados em associação com diferentes combinações de PI: G2 (controle) ­ 2 PI: 0,5% CQ, 0,5% EDMAB; G3 - 3PI: 0,5% CQ; 0,5% DMAEMA, 0,5% DPIHP; G4 - 4 PI: 0,5% CQ; 0,5% EDMAB; 0,5% DMAEMA; 0,5% DPIHP. As três formulações foram polimerizadas em duas densidades de potência de LED: 550 mW/cm2 e 1200 mW/cm2. O grau de conversão (DC) dos monômeros adesivos foi monitorado in situ através do FTIR durante 600 s. Amostras foram preparadas para cada formulação para análise de resistência à flexão (FS), módulo de elasticidade (ME), sorção (SOR) e solubilidade (SOL). Os dados foram submetidos aos testes ANOVA 2-fatores e Tukey (5%). Resultados: DC: houve diferença significativa entre os sistemas adesivos (G2

Assuntos
Radiação , Adesivos Dentinários , Cura Luminosa de Adesivos Dentários , Fotoiniciadores Dentários
2.
São José dos Campos; s.n; 2022. 46 p. tab, ilus.
Tese em Português | BBO - Odontologia | ID: biblio-1397775

RESUMO

O objetivo do presente estudo in vitro é investigar possíveis alterações nas propriedades mecânicas de alinhadores transparentes de poliuretano (PU). Em um estudo piloto, amostras de alinhadores foram submetidas à Espectroscopia Raman antes e depois de irradiações de UV e de LED, e os resultados demonstraram evidente alteração da estrutura molecular. Em virtude disso, foi levantada a hipótese de que as radiações também provoquem alterações nas propriedades mecânicas. Foram confeccionados trinta alinhadores, pela empresa Align Technology Inc. (Invisalign ®), distribuídos em três grupos de dez alinhadores cada. Um grupo controle não sofreu irradiação, e os outros dois grupos foram irradiados: um com radiação UV dentro de uma câmara construída para esse tipo de experimento e um terceiro grupo com radiação LED por fotopolimerizador específico. Os grupos foram definidos, as irradiações foram efetuadas sob sigilo por um operador e as identificações, armazenadas em envelopes lacrados, somente foram reveladas após a conclusão dos testes e tabulação dos dados obtidos. Para avaliação das propriedades mecânicas, neste caso resistência à deformação, utilizou-se uma máquina de ensaio universal para o teste de carga. Os alinhadores foram preenchidos com gesso, com um alívio que deixou livres as áreas a serem testadas. O teste de tensão mostrou que tendo como referência o grupo controle, os alinhadores submetidos à radiação UV tornaram-se menos rígidos e os submetidos à radiação LED tornaram-se mais rígidos. O teste de H de Kruskal-Wallis foi realizado e evidenciou não haver diferença estatisticamente significativa na carga aplicada nas amostras dos diferentes grupos. O mesmo teste foi utilizado para avaliar a diferença entre a deformação ocorrida e o módulo de elasticidade nos três grupos. A hipótese nula foi rejeitada em ambos os testes, considerando o nível de 5% de significância, o que assegura que há uma diferença significativa entre os três grupos quanto à irradiação de UV ou LED. Ainda assim, para uma avaliação mais minuciosa utilizou-se o teste de Mann-Whtiney comparando os grupos dois a dois. O resultado apontou que as irradiações aplicadas neste estudo são responsáveis pelas diferenças estatísticas apresentadas. (AU)


The aim of the present in vitro study is to investigate possible changes in the mechanical properties of transparent polyurethane (PU) aligners. In a pilot study, specimens of aligners were subjected to Raman Spectroscopy before and after UV and LED irradiation, and the results showed evident alteration of the molecular structure. Because of this, it was hypothesized that the radiations also cause changes in the mechanical properties. Thirty aligners were made by Align Technology Inc. (Invisalign®), distributed in three groups of ten aligners each. A control group was not irradiated, and the other two groups were irradiated: one with UV radiation inside a chamber built for this type of experiment, and the third group with LED radiation by a specific photopolymerizer. The groups were defined, the irradiations were done under confidentiality by an operator and the identifications, stored in sealed envelopes, were only revealed after the completion of the tests and tabulation of the data obtained. To evaluate the mechanical properties, in this case resistance to deformation, a universal testing machine was used for the load test. The aligners were filled with plaster, with a relief that left free the areas to be tested. The tension test showed that taking the control group as reference, the aligners submitted to UV radiation became less rigid and those submitted to LED radiation became more rigid. The Kruskal-Wallis H test was performed and showed that there was no statistically significant difference in the load applied to the samples of the different groups. The same test was used to evaluate the difference between the deformation occurred and the modulus of elasticity in the three groups. The null hypothesis was rejected in both tests, considering the 5% significance level, which ensures that there is a significant difference between the three groups regarding UV or LED irradiation. Even so, for a more detailed evaluation the Mann-Whtiney test was used, comparing the groups two by two. The result pointed out that the irradiations applied in this study are responsible for the statistical differences presented (AU)


Assuntos
Aparelhos Ortodônticos Removíveis , Poliuretanos , Análise Espectral Raman , Radiação , Raios Ultravioleta , Testes Mecânicos
3.
Rio de Janeiro; s.n; s.n; 2016. 67 p. ilus.
Tese em Português | BBO - Odontologia | ID: biblio-915692

RESUMO

Radiotherapy (RXT) is one of the main treatments in cases of head and neck cancer and effects of radiation, such as radiation caries, xerostomia and oral mucositis are among the most observed effects after treatment. Chlorhexidine association to glass ionomer cement (GIC) has shown effective antimicrobial activity against the Streptococcus mutans in vitro conditions. However it has only been tested without the use of radiation. The objective of this work is to study the antibacterial effect against S. mutans, the biocompatibility and the pro-inflammatory process induced by a GIC with or without incorporation of chlorhexidine diacetate (dCHX) before and after being radiated under radiotherapy treatment conditions. Test specimens were made in dimensions of 2.5 mm radius x 2 mm thick with GIC incorporated with dCHX percentages at 0%, 0.5%, 1.0% and 2.0%. Half of the samples of each concentration were irradiated with 60 Gy. Antimicrobial activity was tested after exhaustion, with daily changes of sterile distilled water for 270 days. The cytotoxicity was performed by MTT assay according to ISO 10993-5/2009. The pro-inflammatory response was evaluated histologically from the implantation of the samples in subcutaneous tissue of rats. Statistical analysis was performed by Kruskal-Wallis and Dunn tests (p <0.05). All experimental groups were able to inhibit the growth of S. mutans. Cytotoxicity was higher in irradiated groups, regardless of the percentage of incorporation of dCHX. The group without dCHX and subjected to radiation was the condition with higher pro-inflammatory effects, whereas the group with 0.05% dCHX and also submitted to radiation showed less pro-inflammatory effect was (p <0.05). Considering the limitations of this work the following conclusions can be made: 1- radiation or incorporation of dCHX not interfere with the antimicrobial activity against S. mutans for up to 270 days of exhaustion; 2 - the radiation influenced the cytotoxicity, reducing cell viability in all groups, suggesting the use of GIC incorporated with less than 2% dCHX if there is submission to radiation under the conditions of this study; 3 - the proinflammatory analysis also adivse that, in radiation exposure cases, to choose the use of GIV embedded with dCHX and, otherwise, to choose GIC without dCHX.


Radiotherapy (RXT) is one of the main treatments in cases of head and neck cancer and effects of radiation, such as radiation caries, xerostomia and oral mucositis are among the most observed effects after treatment. Chlorhexidine association to glass ionomer cement (GIC) has shown effective antimicrobial activity against the Streptococcus mutans in vitro conditions. However it has only been tested without the use of radiation. The objective of this work is to study the antibacterial effect against S. mutans, the biocompatibility and the pro-inflammatory process induced by a GIC with or without incorporation of chlorhexidine diacetate (dCHX) before and after being radiated under radiotherapy treatment conditions. Test specimens were made in dimensions of 2.5 mm radius x 2 mm thick with GIC incorporated with dCHX percentages at 0%, 0.5%, 1.0% and 2.0%. Half of the samples of each concentration were irradiated with 60 Gy. Antimicrobial activity was tested after exhaustion, with daily changes of sterile distilled water for 270 days. The cytotoxicity was performed by MTT assay according to ISO 10993-5/2009. The pro-inflammatory response was evaluated histologically from the implantation of the samples in subcutaneous tissue of rats. Statistical analysis was performed by Kruskal-Wallis and Dunn tests (p <0.05). All experimental groups were able to inhibit the growth of S. mutans. Cytotoxicity was higher in irradiated groups, regardless of the percentage of incorporation of dCHX. The group without dCHX and subjected to radiation was the condition with higher pro-inflammatory effects, whereas the group with 0.05% dCHX and also submitted to radiation showed less pro-inflammatory effect was (p <0.05). Considering the limitations of this work the following conclusions can be made: 1- radiation or incorporation of dCHX not interfere with the antimicrobial activity against S. mutans for up to 270 days of exhaustion; 2 - the radiation influenced the cytotoxicity, reducing cell viability in all groups, suggesting the use of GIC incorporated with less than 2% dCHX if there is submission to radiation under the conditions of this study; 3 - the proinflammatory analysis also adivse that, in radiation exposure cases, to choose the use of GIV embedded with dCHX and, otherwise, to choose GIC without dCHX.


Assuntos
Anti-Infecciosos Locais/farmacologia , Clorexidina/farmacologia , Dentística Operatória , Cimentos de Ionômeros de Vidro/efeitos da radiação , Cimentos de Ionômeros de Vidro/toxicidade , Teste de Materiais , Streptococcus mutans/efeitos dos fármacos , Sobrevivência Celular , Radiação , Estatísticas não Paramétricas
4.
Rev. odontol. UNESP (Online) ; 44(3): 131-136, May-Jun/2015. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-749887

RESUMO

Aim: The present study evaluated the morphological and chemical changes of dentin produced by different sterilization methods, using scanning electron microscopy (SEM) and energy-dispersive X-ray spectrometry (EDS) analysis. Material and method: Five human teeth were sectioned into 4 samples, each divided into 3 specimens. The specimens were separated into sterilization groups, as follows: wet heat under pressure; cobalt 60 gamma radiation; and control (without sterilization). After sterilization, the 60 specimens were analyzed by SEM under 3 magnifications: 1500X, 5000X, and 10000X. The images were analyzed by 3 calibrated examiners, who assigned scores according to the changes observed in the dentinal tubules: 0 = no morphological change; 1, 2 and 3 = slight, medium and complete obliteration of the dentinal tubules. The chemical composition of dentin was assessed by EDS, with 15 kV incidence and 1  µm penetration. Result: The data obtained were submitted to the statistical tests of Kruskall-Wallis and ANOVA. It was observed that both sterilization methods – with autoclave and with cobalt 60 gamma radiation - produced no significant changes to the morphology of the dentinal tubules or to the chemical composition of dentin. Conclusion: Both methods may thus be used to sterilize teeth for research conducted in vitro. .


Objetivo: O presente estudo teve como objetivo avaliar as alterações morfológicas e químicas na dentina geradas por diferentes métodos de esterilização, através de microscopia eletrônica de varredura (MEV) e da análise por espectrometria de energia dispersiva de raios-X. Material e método: Seccionaram-se 5 dentes humanos em 4 amostras, as quais foram divididas em 3 espécimes cada, totalizando 60 espécimes. Os espécimes foram separados conforme os grupos de esterilização: calor úmido sob pressão; radiação gama cobalto 60; controle (sem esterilização). Após a esterilização, os 60 espécimes foram analisados por MEV, usando 3 aumentos: 1500X, 5000X, 10000X. As imagens foram analisadas por 3 examinadores previamente calibrados, que distribuíram escores referentes às alterações observadas nos túbulos dentinários: 0 = sem alteração morfológica, 1 = baixa obliteração dos túbulos dentinários, 2 = moderada obliteração, 3 = completa obliteração. A composição química da dentina foi avaliada por meio do processo EDS, com 15 kV de incidência e penetração de 1 µm. Os dados obtidos foram submetidos ao teste estatístico de Kruskall-Wallis com nível de significância de 5%. Resultado: De acordo com os resultados obtidos, verificou-se que a esterilização tanto por autoclave quanto por radiação gama cobalto 60 não provocou alterações significativas na morfologia dos túbulos dentinários e na constituição química da dentina. Conclusão: Concluiu-se que ambos os métodos podem ser utilizados para a esterilização de dentes em pesquisa in vitro. .


Assuntos
Análise Espectral , Microscopia Eletrônica de Varredura , Esterilização , Estatísticas não Paramétricas , Dentina , Radiação , Técnicas In Vitro , Fenômenos Químicos
5.
Natal; s.n; dez. 2013. 61 p. (BR).
Tese em Português | BBO - Odontologia | ID: biblio-866928

RESUMO

O laser de baixa intensidade (LBI) tem sido utilizado na Odontologia com a finalidade de promover cicatrização e regeneração dos tecidos. A literatura mostra um efeito positivo do LBI na proliferação celular, porém pouco se sabe sobre a sua eficácia na proliferação de células-tronco. O objetivo deste estudo foi avaliar o efeito da irradiação do LBI na taxa proliferativa de células-tronco do ligamento periodontal humano. Extratos de ligamento periodontal foram isolados de dois terceiros molares hígidos removidos por indicação cirúrgica e/ou ortodôntica. Após a digestão enzimática, as células foram cultivadas em meio de cultura α-MEM suplementado com antibióticos e 15% de soro fetal bovino. No terceiro subcultivo, as células foram irradiadas com um laser diodo InGaAlP, utilizando-se duas diferentes densidades de energia (0,5J/cm2 - 16 segundos e 1,0J/cm² - 33 segundos), comprimento de onda de 660nm e potência de 30mW. Uma nova irradiação, utilizando os mesmos parâmetros, foi realizada 48 h após a primeira. Um grupo controle (não irradiado) foi mantido nas mesmas condições experimentais de cultivo. O método de exclusão por azul de Tripan e a atividade mitocondrial das células medida através do ensaio de MTT [brometo de 3-(4,5-dimetiltiazol-2-il)-2,5-difeniltetrazólio], nos intervalos de 0, 24, 48 e 72 h pós-irradiação, foram utilizados a fim de avaliar a proliferação celular. Os dados das contagens celulares foram submetidos a testes estatísticos não paramétricos de Kruskal-Wallis e Mann-Whitney, considerando um intervalo de confiança de 95%. Com o objetivo de verificar possíveis alterações morfológicas nucleares induzidas pelo laser, as células foram submetidas à marcação com DAPI (4'-6-Diamidino-2-phenylindole) no intervalo de 72 h. Os resultados do presente estudo mostraram que a densidade de energia de 1,0 J/cm² promoveu maior proliferação das células em comparação com os outros grupos (controle e laser 0,5 J/cm²) nos intervalos de 48 e 72 h. A atividade mitocondrial, medida pelo ensaio de MTT, apresentou resultados semelhantes às contagem celulares com azul de Tripan, com o grupo irradiado com 1,0 J/cm² exibindo uma atividade significativamente maior do MTT nos intervalos de 48 e 72 h, quando comparado com o grupo irradiado com 0,5 J/cm². Nenhuma alteração morfológica nuclear foi observada, tanto das células do grupo controle quanto nas células irradiadas. Conclui-se que o LBI apresenta efeitos estimulantes sobre a proliferação de células-tronco do ligamento periodontal humano. Portanto, a aplicação da laserterapia neste tipo celular pode ser importante para futuros avanços na regeneração periodontal. (AU)


Low level laser irradiation (LLLI) has been used in Dentistry to promote wound healing and tissue regeneration. The literature shows a positive effect of LLLI on cell proliferation, but little is known about their effectiveness in promoting stem cells proliferation. The aim of this study was to evaluate the effect of LLLI on the proliferative rate of human periodontal ligament stem cells. Extracts of periodontal ligament were isolated from two third molars removed by surgical and/or orthodontic indication. After enzymatic digestion, the cells were grown in α-MEM culture medium supplemented with antibiotics and 15% fetal bovine serum. On the third subculture, the cells were irradiated with a InGaAlP-diode laser, using two different energy densities (0,5J/cm2 - 16 seconds and 1,0J/cm² - 33 seconds), with wavelength of 660nm and output power of 30mW. A new irradiation, using the same parameters, was performed 48h after the first. A control group (non irradiated) was kept under the same experimental culture conditions. The Trypan blue exclusion test and the mitochondrial activity of the cells measured by MTT [3-(4,5-Dimethylthiazol-2-yl)-2,5-Diphenyltetrazolium Bromide] essay were performed to assess the cell proliferation in the intervals of 0, 24, 48 e 72 h after irradiation. The data of cell counts were submitted to nonparametrical statistical tests (Kruskal-Wallis and Mann-Whitney), considering a confidence interval of 95%. DAPI (4'-6-Diamidino-2-phenylindole) staining of the cells was performed at 72h interval to evaluate possible nuclear morphological changes induced by LLLI. The results of this study show that the energy density of 1,0 J/cm² promoted greater cell proliferation compared to the other groups (control and 0,5 J/cm²) at intervals of 48 and 72h. The mitochondrial activity measured by MTT essay showed similar results to the Trypan blue cell counting test. The group irradiated with 1,0J/cm² exhibited a significantly higher MTT activity in the intervals of 48 and 72h, when compared to the group irradiated with 0,5J/cm². No nuclear morphological change was observed in the cells from the three groups studied. It is concluded that LLLI has stimulatory effects on the proliferation of human periodontal ligament stem cells. Therefore, the use of laser irradiation in this cell type may be important to promote future advances in periodontal regeneration. (AU)


Assuntos
Cicatrização , Células-Tronco , Dente Serotino , Ligamento Periodontal , Proliferação de Células , Radiação , Regeneração Tecidual Guiada , Regeneração Óssea , Terapia a Laser , Estatísticas não Paramétricas , Técnicas In Vitro , Terapia com Luz de Baixa Intensidade/métodos
6.
São José dos Campos; s.n; 2013. 119 p. ilus, tab, graf.
Tese em Português | BBO - Odontologia | ID: biblio-867548

RESUMO

O objetivo deste estudo foi avaliar os efeitos da irradiação de Nd:YAGlaser e da pressão pulpar simulada na variação de temperatura intrapulpar. Cem molares humanos hígidos foram seccionados 1 mm abaixo da junção amelocementária para separação da coroa da porção radicular e seccionados paralelos à superfície oclusal para exposição de 2 mm de espessura de dentina. As amostras foram divididas aleatoriamente em 2 grupos (n=50) de acordo com a presença e ausência de pressão pulpar simulada. Cada grupo foi dividido em 5 subgrupos (n=10) conforme a variação nos parâmetros de energia do Nd:YAG laser: 60, 80, 100, 120 e 140 mJ. As amostras foram tratadas com: ácido fosfórico 37%(Scotchbond Universal), sistema adesivo Scotchbond Universal (3M ESPE), irradiação com Nd:YAG laser por 60 s e fotopolimerização por 10 s. Avaliou-se a temperatura intrapulpar por meio de um termômetro digital posicionado no corno pulpar mais alto. A pressão pulpar simulada foi de 15 cm de H2O. Para o grupo sem pressão pulpar simulada, a câmara pulpar foi preenchida com pasta térmica. A análise estatística consistiu nos testes ANOVA 2-fatores (parâmetros de energia do laser e pressão pulpar) e Tukey com nível de significância de 5% (p<0,05). Segundo o teste ANOVA 2-fatores todos os fatores (parâmetros de energia do laser e pressão pulpar) apresentaram efeito estatisticamente significante (p<0,05)na variação da temperatura. A maior média (14,30ºC) foi observada no grupo irradiado com 140 mJ sem pressão pulpar simulada, enquanto que a menor média (3,90ºC) foi apresentada pelo grupo irradiado a 60 mJ compressão pulpar simulada. Observou-se que os grupos irradiados compressão pulpar simulada apresentaram temperaturas médias inferiores; e as médias aumentaram conforme o aumento dos parâmetros de energia do laser. Assim, concluiu-se que a variação de temperatura durante a irradiação laser é dependente dos parâmetros de energia do Nd:YAG laser e da pressão intrapulpar simulada


The aim of the present study was to evaluate the effects of Nd:YAG laser irradiation and simulated pulpal pressure on intrapulpal temperature. One hundred sound human molar were sectioned 1 mm below the cemento enamel junction to separate the crown and root portions. A parallel section to the occlusal surfaces exposed 2 mm thickness of dentin. The samples were divided into two groups (n=50) according to presence and absence of simulated pulpal pressure. Each group was divided into five groups (n=10) depending on the variation of Nd:YAG laser energy parameters: 60, 80, 100, 120, 140 mJ. The samples were treated with: phosphoric acid 37% (Scotchbond Universal), adhesive system(Scotchbond Universal/ 3M ESPE), irradiation with Nd:YAG laser for 60 sand light cure for 10 s. A digital thermometer was positioned in the highest pulp horn to evaluate the intrapulpal temperature. The simulated pulpal pressure was of 15 cm. For the group with out simulated pulpal pressure,the pulp chamber was filled with thermal paste. Statistical analysis consisted of two-way analysis of variance (ANOVA; laser energy parameters and pulpal pressure) and Tukey’s test with a significance level of 5% (p<0.05). ANOVA revealed statistically significant effect in the temperature range (p<0.05). The highest average (14.30 ºC) was observed in the group irradiated with 140 mJ without pulpal pressure simulation, while the lowest average (3.90 ºC) was observed in the group irradiated at 60 mJ with simulated pulpal pressure. It was observed that the groups treated with simulated pulpal pressure had lower temperature mean values, and the mean values increased with increasing laser energy parameters. Thus, this study concluded that the variation in temperature during laser irradiation is dependent on the energy parameters of Nd:YAGlaser and intrapulpal pressure simulation


Assuntos
Cavidade Pulpar , Pressão Hidrostática , Lasers , Radiação , Termômetros
7.
Rev. Assoc. Paul. Cir. Dent ; 62(3): 184-187, maio-jun. 2008. ilus, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-539256

RESUMO

A microcirculação pode ser considerada uma unidade funcional do sistema circulatório, sendo constituída pelos menores vasos distais. A radiação eletromagnética pode influenciar essa unidade agindo sobre esfíncteres pré-capilares. Essa influência pode gerar alterações na pressão hidrostática capilar, contribuindo na reabsorção de exsudato inflamatório e eliminando acúmulos de catabólitos intermediários. O efeito da radiação eletromagnética coerente na região do visível (vermelho) tem sido estudado principalmente no processo inflamatório, tendo sido encontrado aumento da permeabilidade capilar e vasodilatação. Contudo, poucos trabalhos foram realizados com o emprego de radiação eletromagnética não-coerente (LED) na região do visível. Dessa forma, o objetivo deste estudo foi observar o efeito do LED (640 :!: 20 nm, 100 m W, 1,77 cm2) sobre a microcirculação auricular em camundongos. Para tal, foram utilizados oito animais divididos em dois grupos (grupo placebo e grupo 3 J/cm2). A superfície auricular externa dos animais foi monitorada (durante 15 minutos) sob microscopia óptica (100x) e analisada com o auxílio do programa ImageJ. Observou-se uma diferença significativa no diâmetro dos vasos nos primeiros minutos após a irradiação, comprovando a existência de um efeito vasodilatador da radiação eletromagnética não-coerente, na região do vermelho, com os parâmetros testados. Esse resultado pode ser otimizado empregando-se maior fluência.


Microcirculation, considered a functional unit of the circulatory system, is composed of many smaller distal vessels. The electromagnetic radiation can influence this unit acting on the precapillary sphincters. This influence might generate alterations on the capillary hydrostatic pressure, contributing to the reabsortion of the inflammatory exudation and eliminating intermediate catabolite accumulation. The effect of coherent electromagnetic radiation on the visible region (red) has been studied mainly in the inflammatory process, and an increase in the capillary permeability and vasodilation was found. However few studies have been conducted on the use of noncoherent electromagnetic radiation (LED) in the visible region. Therefore, the aim of this study was to observe the effect of the LED (640:!: 20 nm, 100 mW, 1.77 cm2) on the auricular circulation of mice. To this end 8 animals were separated into 2 groups (placebo group and 3 J/cm2 group). The external auricular surface was monitored (15 minutes) under light microscopy (100X) and analysed with the help of IMAGEJ program. A significant difference was observed in the vessel diameter in the first minutes after the irradiation, proving the existence of a vasodilator effect of non coherent electromagnetic radiation in the red region of the tested parameters. This result can be optimized with the use of greater fluence.


Assuntos
Animais , Camundongos , Microcirculação , Fototerapia , Permeabilidade Capilar/efeitos da radiação , Radiação , Vasodilatação/efeitos da radiação
8.
Porto Alegre; s.n; 2007. 44 p. ilus.
Tese em Português | BBO - Odontologia | ID: biblio-864214

RESUMO

Esta pesquisa teve como objetivo estudar o efeito da radiação X, em baixas doses, nos processos de perda e reparação óssea alveolar em camundongos submetidos ao descolamento de retalho mucoperiostal. O processo de perda óssea alveolar é um fenômeno comum em todos os indivíduos, entretanto, sabe-se que o descolamento da mucosa nesta região estimula tal fenômeno. Sabendo dos efeitos biológicos da radiação X sobre os tecidos, procurou-se analisar a possível interferência de ação da mesma como agente adicional a este processo. Foram utilizados 72 camundongos CF 1 Mus Domesticus divididos em grupo teste (expostos à quatro doses semanais de 0,002C/Kg de radiação) e controle (não expostos à radiação). Os resultados mostraram, segundo análises estatísticas, utilizando o teste Kruskal Wallis e teste U de Mann-Whitney, que não houve diferença significativa, considerando p= 0,05, em relação a perda e reparação óssea alveolar entre o grupo teste e controle. Pôde-se concluir que dose de radiação compatível com exames de investigação por imagem, por um período de quatro semanas, não altera os padrões de reabsorção e reparação óssea alveolar em camundongos submetidos ao descolamento do retalho mucoperiostal.


Assuntos
Camundongos , Animais , Perda do Osso Alveolar , Radiação , Retalhos Cirúrgicos
11.
Pesqui. odontol. bras ; 16(4): 293-298, out.-dez. 2002. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-327300

RESUMO

O objetivo desta pesquisa experimental foi estudar os efeitos da irradiaçäo por elétrons sobre o conteúdo de colágeno e a organizaçäo macromolecular do tecido de granulaçäo, na pele de ratos diabéticos. Para tanto, 48 ratos da linhagem Wistar foram separados em 4 grupos: controle; irradiado; diabético e diabético irradiado. Inicialmente, a diabetes melito foi induzida, nos dois últimos grupos, por meio da administraçäo intravenosa de estreptozotocina. Após quinze dias da induçäo, todos os animais foram submetidos a uma cirurgia para a produçäo de uma ferida excisional, na regiäo dorsal anterior. No terceiro dia pós-operatório, aplicou-se uma dose única de 1Gy, de feixes de elétrons com 6MeV de energia, em uma área externa que compreendia cerca de 1cm lateralmente às bordas das feridas. Amostras teciduais dos 4 grupos foram examinadas por microscopia de luz polarizada aos 4, 7, 13 e 21 dias pós-operatórios. Por meio de uma avaliaçäo essencialmente qualitativa, foi possível concluir que a irradiaçäo local por elétrons e as disfunçöes associadas à diabetes determinaram um decréscimo no conteúdo de colágeno do tecido neoformado, que foi mais pronunciado nos animais diabéticos irradiados. A organizaçäo macromolecular do tecido de granulaçäo apresentou-se retardada nos animais irradiados, diabéticos e diabéticos irradiados, em comparaçäo com os animais do grupo controle


Assuntos
Cicatrização , Colágeno , Diabetes Mellitus , Radiação , Ratos Wistar
13.
Bauru; s.n; 1999. 148 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-250457

RESUMO

Este estudo comparou, usando duas resinas compostas, a utilizaçäo de uma técnica de fotoativaçäo contínua com uma sequencial em duas fases, começando com baixa intensidade de luz seguida de uma intensidade maior. A interferência das diferentes intensidades utilizadas foi analisada näo só quanto à formaçäo de fendas marginais mas, também, quanto aos graus de polimerizaçäo dessas resinas, com avaliaçäo da dureza Vickers. Paralelamente, foi verificada a viabilidade de um método simplificado de moldes de polivinilsiloxana para o estudo das fendas. Foi utilizada para a contínua, 650 mW/cm² durante 60 segundos e, para a sequencial, intensidades de 180 mW/cm², 280 mW/cm² e 380 mW/cm², respectivamente, por períodos de 20 segundos seguidos de uma intensidade de 650 mW/cm² por 40 segundos. Foram mensuradas as fendas na interface de restauraçöes com a dentina usando as resinas compostas Z100 e Solitaire, em cavidades dentinárias cilíndricas de molares humanos recém-extraídos, através da microscopia óptica, feita diretamente nesses espécimes, e indiretamente nos moldes. Por meio do tratamento estatístico dos resultados com a ANOVA e o teste de Tukey, concluiu-se que as fendas marginais foram menores, quando se utilizou a ativaçäo em duas etapas, com a intensidade inicial de 180 mW/cm² por 20 segundos, seguida da maior intensidade de 650 mW/cm² por 40 segundos...


Assuntos
Resinas Compostas/análise , Resinas Compostas/efeitos da radiação , Dentina/química , Luz , Materiais Dentários/análise , Materiais Dentários/efeitos da radiação , Microscopia , Radiação , Efeitos da Radiação
14.
In. Freitas, Aguinaldo de; Rosa, José Edu; Souza, Icléo Faria e. Radiologia odontológica. Säo Paulo, Artes Médicas, 4 ed; 1998. p.15-25, ilus, tab, graf.
Monografia em Português | LILACS, BBO - Odontologia | ID: lil-246540
17.
Rev. odontol. Univ. Säo Paulo ; 11(1): 5-10, jan.-mar. 1997. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-187519

RESUMO

No presente estudo, foram utilizadas combinaçöes de filtros de alumínio e cobre/alumínio, filmes dos grupos D e E e colimaçäo circular e retangular, para determinar a qualidade da imagem radiográfica e as exposiçöes às radiaçöes resultantes dessas interaçöes. O estudo foi dividido em uma parte laboratorial e em outra simulando condiçöes clínicas. A análise estatística pela ANOVA permitiu as seguintes conclusöes: a) houve concordância entre os dois métodos com relaçäo ao fato de que os melhores valores de densidade e contraste foram obtidos com filme do grupo D, filtro de alumínio e colimaçäo retangular; b) a colimaçäo retangular melhorou o constrate, porém, o exame clínico näo observou essa diferença; c) a combinaçäo filme do grupo E, filtraçäo com cobre/alumínio e colimaçäo retangular reduziu significativamente a exposiçäo à radiaçäo


Assuntos
Controle de Qualidade , Intensificação de Imagem Radiográfica , Radiografia Dentária/normas , Radiação
19.
Rev. odontol. UNESP ; 25(2): 259-67, jul.-dez. 1996. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-197514

RESUMO

Realizou-se estudo histomorfológico de glândulas submandibulares de ratos submetidas a doses baixas de radiaçäo X, tendo em vista o näo conhecimento da dose mínima capaz de produzir reaçöes celulares e a escassez de trabalhos na literatura empregando doses consideradas baixas. O corpo dos animais foi recoberto por lâmina de chumbo perfurada na regiäo cervical onde se localizam as glândulas submandibulares, que foram expostas a 1,80 Gy de radiaçäo X em dose única. Após 24, 48, 72 horas, 7, 14 e 21 dias, as glândulas foram removidas e processadas para estudos em microscopia de luz, tendo sido observadas alteraçöes degenerativas discretas e pleomorfismo nuclear, principalmente nos primeiros três períodos experimentais


Assuntos
Animais , Ratos , Efeitos da Radiação , Glândulas Salivares , Radiação
20.
Rev. Fac. Odontol. Bauru ; 4(3/4): 27-31, jul.-dez. 1996. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-222565

RESUMO

A radiaçäo eletromagnética (REM) na faixa de rádio-frequência (rf) que ocupa de 300 KHz a 300 MHz é utilizada atualmente para inúmeros fins industriais, médicos e científicos. A REM ao interagir com materiais biológicos pode ser transmitida, absorvida e refletida em vários graus, podendo resultar tanto em efeitos benéficos medicinais quanto em danos biológicos. Esse trabalho teve o objetivo de estudar morfometricamente os possíveis efeitos da radiofrequência e de gradientes de campos magnéticos em glândulas submandibulares de fetos de ratos. Para tal, foram irradiadas fêmeas com rf de 20 MHz, 7,4 mW de potência e SAR=30 mW/kg (Specific Absortion Rate), durante 10 minutos diários, até o 20§ dia de gestaçäo, após o qual foram sacrificadas. Seus fetos foram retirados e processados para análise em microscópio de luz. Foram feitas avaliaçöes morfométricas da densidade de volume, volume absoluto e relaçäo núcleo-citoplasma das células de túbulos terminais, vasos sanguíneos e tecido conjuntivo da glândula submandibular. A comparaçäo dos resultados pela análise de variância demonstrou ocorrer um significativo aumento da densidade de volume e volume absoluto nuclear e citoplasmático das células dos túbulos terminais do grupo irradiado em relaçäo ao controle. Em relaçäo as células de ductos näo houve diferença estatística significante. A densidade de volume de tecido conjuntivo foi maior no controle. Em base a esses dados é possível pressupor que radiaçöes eletromagnéticas mesmo as de baixa intensidade podem promover alteraçöes volumétricas de células dos túbulos terminais


Assuntos
Animais , Feminino , Ratos , Glândula Submandibular/efeitos da radiação , Radiação , Glândula Submandibular/lesões , Glândula Submandibular/metabolismo , Lesões por Radiação/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...