Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Filtros aplicados
Base de dados
Intervalo de ano de publicação
1.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 23(4): 208-212, abr. 2005. tab
Artigo em Es | IBECS | ID: ibc-036171

RESUMO

INTRODUCCIÓN. El objetivo de este trabajo fue evaluarla eficacia del sistema LightCycler para la detección de Staphylococcus aureus y estafilococos coagulasa negativos(ECN), y la identificación de resistencia a meticilina directamente en botellas Bactec de hemocultivos positivos. MÉTODOS. Se procesaron 131 botellas de hemocultivos positivos en los que se observaron cocos grampositivos en racimos tras la tinción de Gram y 40 botellas con microorganismos diferentes a estafilococos. Para la extracción del ADN se utilizó el sistema automático MagNAPure LC (Roche Diagnostic). Los cebadores y las sondas dehibridación se diseñaron para la amplificación y detección de las secuencias específicas de un fragmento de 408 pb del gen mecA y de un fragmento de 279 pb del gen nucA. RESULTADOS. Todas las botellas con cepas de S. aureusresistente a meticilina (SARM), sensible a meticilina(SASM) o ECN resistentes a meticilina (ECNRM) fueron correctamente identificados mediante reacción en cadena de la polimerasa (PCR) de los genes nucA y mecA. Una botella con un cultivo mixto de SASM y ECNRM dio resultados positivos para ambos genes. Las 21 botellas con cepas de ECN sensible a meticilina (ECNSM) fueron correctamente identificadas con el gen nucA, pero dos de ellas fueron positivas para el gen mecA. La sensibilidad y la especificidad fueron del 100% para el gen nucA, y del 100 y 97,5%, respectivamente, para el gen mecA. CONCLUSIÓN. Este es un método sensible y específico para la identificación de estafilococos en hemocultivos, y permite también la identificación de cepas resistentes a meticilina en un tiempo máximo de 3 h a partir de la visualización de la tinción de Gram (AU)


INTRODUCTION. The aim of this study was to evaluate the feasibility of detecting Staphylococcus aureus and coagulase-negative staphylococci (CoNS) and of identifying methicillin resistance directly in positive BACTEC blood culture bottles using the LightCycler system. METHODS. One hundred thirty-one positive blood culture bottles in which Gram-positive cocci in cluster were observed after Gram staining and 40 positive bottles with microorganisms other than staphylococci were studied. A molecular assay based on an automated DNA extraction protocol with a MagNA Pure LC instrument was used. Oligonucleotide primers and fluorescence-labeled hybridization probes were designed for amplification and sequence-specific detection of both a 408-pb fragment within the mecA gene and a 279-pb fragment within the S. aureus-specific nucA gene. RESULTS. All the bottles that yielded methicillin-resistant S.aureus (MRSA), methicillin-sensitive S. aureus (MSSA) ormethicillin-resistant CoNS (MRCoNS) strains were correctly identified by the nucA and mecA PCR assays. One bottle that yielded a mixed culture of MSSA and MRCoNSgave positive results for both genes. In the 21 bottles with methicillin-susceptible CoNS (MSCoNS), nucA PCR were negative, but two of these bottles gave positive results forthe mecA gene. The sensitivity and specificity of the nucA gene assay were 100%. The sensitivity and specificity of the PCR assay for detection of methicillin resistance with the mecA gene were 100% and 97.5%, respectively. CONCLUSION. This is a sensitive and highly specific method for identifying staphylococci in positive blood cultures, allowing discrimination between methicillin-susceptible and –resistant strains in less than 3 hours after Gramstain (AU)


Assuntos
Humanos , Bacteriemia/microbiologia , Proteínas de Bactérias/genética , Técnicas Bacteriológicas/instrumentação , DNA Bacteriano/genética , Resistência a Meticilina/genética , Nuclease do Micrococo/genética , Reação em Cadeia da Polimerase/instrumentação , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus , Automação , Bacteriemia/tratamento farmacológico , Coleta de Amostras Sanguíneas/instrumentação , DNA Bacteriano/isolamento & purificação , Infecções Estafilocócicas/tratamento farmacológico , Staphylococcus aureus/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...