Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Arch. esp. urol. (Ed. impr.) ; 76(10): 796-801, diciembre 2023. tab
Artigo em Inglês | IBECS | ID: ibc-229540

RESUMO

Objective: This study aimed to explore the clinical and differential diagnostic value of real-time ultrasound elastography combinedwith transabdominal prostate calcification in prostate cancer (PCa).Methods: This study retrospectively analysed the clinical pathological data of 97 patients with PCa and 105 patients with benignprostatic hyperplasia (BPH) diagnosed by postoperative pathology in our hospital from May 2020 to May 2021; Comparativelyanalysed the clinical data of the two groups, including the elastic strain ratio, elastic image compression index, types of prostatecalcification and calcification diameter; And used logistic regression analysis to screen out the independent risk factors for identifyingPCa and BPH.Results: No significant difference in age, body weight, body mass index, location of calcification and calcification diameter wasobserved between the two groups (p > 0.05), and overt differences in elastic strain ratio, elastic image compression index, typesof calcification, and testosterone were found between the PCa group and BPH group (p < 0.05). Logistic regression analysisshowed that the elastic strain ratio, elastic image compression index and types of calcification were independent risk factors foridentifying PCa (p < 0.05). The area under curve value of combined diagnosis under receiver operating characteristic curve wasas high as 0.756 (95% CI: 0.691–0.813), with a sensitivity of 67.60% and a specificity of 76.30%.Conclusions: A certain correlation is observed amongst elastic strain ratio, elastic image compression index, types of prostatecalcification and the occurrence and development of PCa. The application of real-time ultrasound elastography combined withthe detection of transabdominal prostate calcification in clinical diagnosis can improve the detection rate of PCa, which has animportant clinical application value. (AU)


Assuntos
Humanos , Diagnóstico Diferencial , Elasticidade , Próstata/diagnóstico por imagem , Hiperplasia Prostática , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos
2.
Rev. int. androl. (Internet) ; 21(4): 1-8, oct.-dic. 2023. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-226002

RESUMO

Purpose: The aim of this study is to evaluate the anatomical factors influencing elasticity values of normal testicular parenchyma using shear wave elastography (SWE). Methods: This study examined 68 healthy male volunteers (117 testes in which standard transverse axis ultrasonography views could be obtained) via conventional scrotal ultrasonography and SWE. Both the mean (EMean) and standard deviation (ESD) elasticity values were acquired. Results: In the standard transverse axis view of the rete testis at the mid-lateral edge of the testes, the EMean values in 2mm the testicular parenchyma from the rete testis and the testicular capsule at the same level as the rete testis were all significantly larger than in the central zone (P<0.001, P<0.001, respectively). The EMean value in the testicular parenchyma 2mm from the testicular capsule on the line formed approximately 45° below the horizontal line of the rete testis was significantly larger than in the rete testis approximately 45° above the horizontal line (P<0.001). In two standard transverse axis views, the ESD values in other regions were significantly larger than those in the central zones (all P<0.001). Also, the EMean values in the transmediastinal arteries were larger than those of the surrounding normal testicular parenchyma (P<0.001). Conclusion: Based on SWE, factors including the testicular capsule, the density of testicular fibrous septa, the depth of the Q-Box™, and the transmediastinal artery may influence the testes elasticity measurement. (AU)


Assuntos
Humanos , Masculino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Elasticidade , Tecido Parenquimatoso , Testículo/diagnóstico por imagem , Testículo/anatomia & histologia , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia
3.
Rev. int. med. cienc. act. fis. deporte ; 22(87): 437-453, sept. 2022. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-211081

RESUMO

Los objetivos del estudio fueron describir las propiedades estructurales y mecánicas de los tendones rotuliano y de Aquiles en jugadores senior (>35 años) de bádminton y detectar posibles asimetrías entre el lado dominante y no dominante. La muestra estuvo compuesta por 206 jugadores senior de bádminton (Edad: 52.2±9.6 años) que participaron en el campeonato de Europa Senior en 2018. Se evaluaron las propiedades estructurales (grosor, anchura y área de sección transversal) por medio de un ecógrafo Logiq® S8 y las propiedades mecánicas (elasticidad, tono, rigidez e índice de elastografía) con miotonometría y sonoelastografía de los tendones rotuliano y de Aquiles. Los resultados mostraron que fueron mayores el grosor (5.34±19.90%, p = 0.027) y la anchura (1.57±8.52%, p=0.036) en el tendón de Aquiles no dominante mientras que el tendón rotuliano dominante mostró unos valores mayores para el tono (2.09±12.96%, p=0.002) y para la rigidez (4.41±21.11%, p=0.002) respecto al no dominante. (AU)


The purposes of the study were to describe the structural and mechanical properties of the patellar and Achilles tendons in senior badminton players (>35 years) and to detect possible asymmetries between dominant and non-dominant lower limb. Two hundred and six senior badminton players (52.2±9.6 years old) who participated in the 2018 Senior European Championship volunteered to participate in the study. The structural properties (thickness, width and cross-sectional area) by a Logiq® S8 ultrasound system and the mechanical properties (elasticity, tone, stiffness and elastography index) with myotonometry and sonoelastography of the patellar and Achilles tendons were assessed. Non-dominant Achilles tendon showed greater values for the thickness (5.34±19.90%, p=0.027) and width (1.57±8.52%, p=0.036) than those of the dominant tendon, while the dominant patellar tendon showed higher values for tone (2.09±12.96%, p=0.002) and stiffness (4.41±21.11%, p=0.002) compared to the non-dominant one. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Ligamento Patelar , Esportes com Raquete , Tendão do Calcâneo , Atletas , Elasticidade
4.
Av. odontoestomatol ; 33(6): 263-274, nov.-dic. 2017.
Artigo em Espanhol | IBECS | ID: ibc-172651

RESUMO

En los últimos años, las resinas compuestas han sido mejoradas en cuanto al desgaste, estética y otras propiedades físicas. El mayor problema que persiste con las resinas compuestas es que estos materiales se contraen durante la polimerización. Contracción significa densificación o pérdida de volumen. En la cavidad dental, esta pérdida de volumen compromete la integridad de la interfase entre resina y diente, lo cual favorece la formación de grietas con el riesgo de hipersensibilidad, recidiva de caries o, incluso, fractura de la restauración. En el presente artículo, se expone la actualidad acerca del conocimiento sobre la contracción de polimerización de las resinas compuestas y su relación con el tipo de lámpara de polimerizar. Así mismo, se desarrollan los conceptos de fase obscura, expansión higroscópica, el consecuente estrés de contracción o los nuevos materiales que se presumen carentes de contracción; todo ello, en el marco de la dinámica lógica y normal llevada a cabo a la hora de realizar una obturación utilizando resinas compuestas con independencia de su relleno o partícula de éste. Respecto a las fuentes de polimerización, tanto las lámparas halógenas convencionales o las de alta densidad de potencia, como las LEDs, ofrecen un incremento gradual de la intensidad lumínica, lo que resulta muy útil para disminuir la contracción volumétrica del material


In recent years, composite resins have been improved in terms of wear, aesthetics and other physical properties. The major problem persists with composite resins is that these materials shrink during polymerization. Contraction means densification or loss of volume. In the dental cavity this loss of volume compromises the integrity of the interface between resin and tooth, which favors the formation of cracks with the risk of hypersensitivity, recurrence of caries or even fracture of the restoration. This article presents the current knowledge about the polymerization contraction knowledge of the composite resins and its relation to the type of polymerization lamp. Also the concepts of obscure phase, hygroscopic expansion, the consequent stress of contraction or the new materials that are presumed devoid of contraction are developed, all this in the frame of the logical and normal dynamics carried out at the time of making a seal using composite resins, regardless of their filler or particle thereof. Regarding the sources of polymerization, both conventional halogen lamps and high power density lamps, such as LEDs, offer a gradual increase in light intensity, which is very useful to decrease the volume shrinkage of the material


Assuntos
Humanos , Resinas Compostas/análise , Cura Luminosa de Adesivos Dentários/métodos , Polimerização , Molhabilidade , Análise do Estresse Dentário/métodos , Compômeros/análise , Restauração Dentária Permanente/efeitos adversos , Elasticidade
5.
Nutr. hosp ; 31(1): 334-340, ene. 2015. tab, ilus, graf
Artigo em Espanhol | IBECS | ID: ibc-132613

RESUMO

Las gomitas son golosinas de consumo difundido entre personas de diferentes edades aunque principalmente por los niños. La formulación de este producto requiere azúcar que contribuye a su sabor y consistencia, aunque con el efecto indeseable de incrementar su índice glicémico y calorías provenientes de azúcares simples; se sabe que el consumo de productos con estas dos últimas características están relacionados con la obesidad infantil, la cual es una enfermedad en crecimiento a nivel mundial. La Stevia rebaudiana es una planta que naturalmente contiene glucósidos con alto poder endulzante y que se considera segura para su consumo. El objetivo de este trabajo fue desarrollar una golosina tipo «gomita» reducida en calorías mediante la sustitución de azúcares con Stevia rebaudiana B. y analizar su textura y grado de aceptación. Se elaboraron gomitas con diferente porcentaje de reducción de azúcar (-20, -40, -60, -80 y -100%) y un producto control (100% azúcar), a las cuales se evaluó su desplazamiento y deformación máxima para evaluar la elasticidad, así como la fuerza de ruptura para determinar la resistencia; aquellas gomitas con mejores parámetros de elasticidad y resistencia se les realizaron el análisis proximal y el análisis sensorial con una escala no estructurada aplicada a 90 niños escolares con edades comprendidas entre 6 y 10 años. Se desarrolló una golosina tipo «gomita» reducida en calorías con un porcentaje de sustitución de azúcar de hasta 60% con S. rebaudiana, cuyo nivel de agrado en niños escolares fue estadísticamente igual comparado con la gomita realizada con 100% de azúcar (p<0.05) (AU)


The consumption of gummy candy is widespread among people of different ages but mainly by children. The formulation of this product requires sugar that contributes to their flavor and consistency, but with the undesirable effect of increase its glycemic index and its calories from simple sugars; it is known that consumption of products with these last two characteristics are related to childhood obesity, which is a worldwide growing disease. Stevia rebaudiana is a plant that naturally contains glycosides with high sweetening power and it is considered safe for consumption. Therefore the aim of this work was to develop a gummy candy reduced in calories by replacing sugar with Stevia rebaudiana B., and analyzes its texture and acceptability. Gummy candy were prepared with different percentage of sugar reduction (-20, -40, -60, -80 and -100%) and a product control (100% sugar); gummy elasticity was assess by displacement and maximum deformation, whereas resistance was evaluated by breaking strength; those gummies with better elasticity and resistance parameters underwent proximate analysis and sensory evaluations with a unstructured scale applied to 90 school children aged between 6 and 10 years old. A gummy candy reduced in calories with 60% sugar substitution with S. rebaudiana was developed; the level of satisfaction in school children was statistically the same respect to the gummy made of 100% sugar (p <0.05) (AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Doces , Ingestão de Energia , Stevia/química , Edulcorantes/farmacologia , Elasticidade , Preferências Alimentares , Extratos Vegetais
6.
Med. oral patol. oral cir. bucal (Internet) ; 18(4): 721-724, jul. 2013. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-114497

RESUMO

NiTi spring coils were used to obtain large deformation under a constant force. The device consists on a NiTi coil spring, superelastic at body temperature, in order to have a stress plateau during the austenitic retransformation during the unloading. The temperature variations induced changes in the spring force. Objectives: The aim of this study is to investigate the effect of the temperature variations in the spring forces and corrosion behaviour simulating the ingestion hot/cold drinks and food. Study Design: The springs were subjected to a tensile force using universal testing machine MTS-Adamel (100 N load cell). All tests were performed in artificial saliva maintained at different temperatures. The corrosion tests were performed according to the ISO-standard 10993-15:2000. Results: The increase in temperature of 18oC induced an increase in the spring force of 30%. However, when the temperature returns to 37oC the distraction force recovers near the initial level. After cooling down the spring to 15oC, the force decreased by 46%. This investigation show as the temperature increase, the corrosion potential shifts towards negative values and the corrosion density is rising. Conclusions: The changes of the temperatures do not modify the superelastic behaviour of the NiTi closed-coil springs. The corrosion potential of NiTi in artificial saliva is decreasing by the rise of the temperatures (AU)


Assuntos
Humanos , Temperatura Corporal , Aparelhos Ortodônticos , Ligas Dentárias/análise , Elasticidade , Níquel/análise , Titânio/análise , Corrosão , Modelos Biológicos
7.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 26(9): 561-563, nov. 2008. tab
Artigo em Es | IBECS | ID: ibc-70173

RESUMO

La fibrosis hepática avanzada disminuye la cifra absoluta de linfocitos CD4+ en pacientes con infección por el virus de la inmunodeficiencia humana (VIH). Se desconoce si existe una correlación entre rigidez hepática medida por elastografía transitoria y la cifra absoluta de linfocitosCD4+.Se realiza análisis de la correlación entre resultados de elastografía transitoria y cifras de linfocitos CD4+ en223 sujetos coinfectados por VIH y virus hepatotropos. Los valores absolutos de linfocitos CD4+ fueron menores en pacientes con fibrosis significativa (384 céls./ml frentea 431 céls./ml; p = 0,023) y en pacientes con fibrosisavanzada (330 céls./ml frente a 431 céls./ml; p = 0,002).Existe una asociación significativa entre la fibrosishepática medida por elastografía transitoria y los valores absolutos de linfocitos CD4+ en pacientes coinfectados por VIH y virus hepatotropos (AU)


Advanced hepatic fibrosis decreases absoluteCD4+ lymphocyte count in HIV-infected patients. The correlation between hepatic stiffness measured by transient elastography and absolute CD4+ lymphocytecount is unknown. Analysis of the correlation between transient elastography parameters and absolute CD4+ lymphocyte count in223 HIV-infected patients with chronic viral hepatitis. As compared to patients without significant fibrosis, absolute CD4+ cell count was lower in patients with significant hepatic fibrosis (384 cel/mL vs. 431 cel/mL;P = 0.023) and in patients with advanced hepatic fibrosis(330 cel/mL vs. 431 cel/mL; P = 0.002). There is a significant association between hepatic stiffness measured by transient elastography and absoluteCD4 lymphocyte count in HIV-infected patients with chronic viral hepatitis (AU)


Assuntos
Humanos , Cirrose Hepática/diagnóstico , Antígenos CD4/isolamento & purificação , Cirrose Hepática/fisiopatologia , Elasticidade , Infecções por HIV/complicações , Hepatite Viral Humana/complicações
8.
Arch. Soc. Esp. Oftalmol ; 82(8): 489-494, ago. 2007. ilus
Artigo em Es | IBECS | ID: ibc-055761

RESUMO

Propósito: Comparar el comportamiento de ambos viscoelásticos intraoperatoriamente. Método: Estudio prospectivo aleatorio en el que se incluyen 35 pacientes con catarata, intervenidos mediante facoemulsificación ultrasónica e implantación de lente intraocular. En el grupo A, se incluyeron 17 pacientes en los que se utilizó Healon(R) (hialuronato sódico 1%) y en el grupo B, 18 pacientes en los que se utilizó DisCoVisc(R) (ácido hialurónico al 1,6% y condroitín sulfato al 4%). Tras la intervención el cirujano rellenó un cuestionario sobre el comportamiento de los viscoelásticos en cada momento de la cirugía. Resultados: El DisCoVisc(R) se ha comportado como dispersivo y cohesivo durante la capsulorrexis, la facoemulsificación y la aspiración del viscoelástico, mientras el Healon® ha demostrado ser una sustancia cohesiva en dichas fases. El DisCo- Visc(R) permite una mejor visualización y transparencia durante todos los pasos quirúrgicos, y mantiene mejor el el espacio capsular durante la implantación de la lente intraocular. La aspiración del viscoelástico ha resultado ser más fácil utilizando Healon(R). Conclusiones: El DisCoVisc(R) es un nuevo viscoelástico que presenta propiedades dispersivas y cohesivas, evitando la utilización de dos viscoelásticos (uno cohesivo y otro dispersivo) para adaptarse a las necesidades de todos los pasos de la facoemulsificación. Ha demostrado ofrecer mayor transparencia en la cirugía con respecto al Healon(R) y un mejor mantenimiento de la cámara anterior en todas las fases de la cirugía. La aspiración del Healon(R) se realizó con mayor sencillez por su carácter cohesivo


Objective: To compare the intraoperative behaviour of both, DisCoVisc(R) and Healon(R) used as viscoelastics in cataract surgery. Method: We prospectively evaluated 35 patients with cataracts who underwent phacoemulsification and intraocular lens implantation. Patients were randomized into two groups. Group A included 17 patients in where Healon(R) was used as a viscoelastic, whereas group B included 18 patients in where the viscoelastic used was DisCoVisc(R). After each procedure, the surgeon filled in a questionnaire describing the behaviour of the viscoelastic during the different stages of phacoemulsification. Results: DisCoVisc(R) behaved as both cohesive and dispersive viscoelastic during capsulorrhexis, phacoemulsification and viscoelastic aspiration, whereas Healon® acted as a cohesive substance during all surgical stages. DisCoVisc(R) enabled better visualization and transparency during all the surgical stages and maintains the capsular bag better during the intraocular lens implantation. Viscoelastic aspiration was easier with Healon(R). Conclusions: DisCoVisc(R) is a new viscosurgical device with both cohesive and dispersive properties, which avoids using two different viscoelastics to improve the performance at different surgical stages. DisCoVisc(R) has been shown to be more transparent and provides better anterior chamber maintenance when compared with Healon®. Healon® was more easily aspirated due to its cohesive character


Assuntos
Humanos , Implante de Lente Intraocular , Facoemulsificação/métodos , Condroitina/administração & dosagem , Ácido Hialurônico/administração & dosagem , Resultado do Tratamento , Estudos Prospectivos , Elasticidade , Viscosidade
9.
Dentum (Barc.) ; 7(1): 31-36, ene.-mar. 2007. ilus, tab
Artigo em Es | IBECS | ID: ibc-056032

RESUMO

Diente e implante son elementos que presentan un comportamiento biomecánico diferente debido a la presencia de un ligamento periodontal en uno y no en el otro. Debemos tener en cuenta este hecho cuando diseñemos una prótesis que vaya a ser soportada por estos dos pilares diferentes, para intentar disminuir en lo posible las tensiones que tendrán que soportar tanto los pilares como las estructuras de soporte que los rodean. Para estudiar dichas tensiones, fabricamos un modelo de simulación consistente en . un prisma de resina con propiedades fotoelásticas dentro del cual incluimos un implante y un diente que uniremos con prótesis fijas de tres diseños diferentes. Ejerceremos cargas de intensidades diferentes, sobre tres puntos diferentes de las prótesis, para comparar el patrón dé distribución de tensiones que se genera en cada una de las situaciones recreadas (AU)


Teeth and implants are elements with a different biomechanic behaviour due to the presence of a periodontal ligament around the tooth and its absence around the implant. This must be taken Into consideration whenever we plan to design a tooth-implant supported prosthesis so that the stress generated around the abutments could be reducedas much as posible, A simulation model made of resin with photoelastic properties, with an implant and a tooth included in it and connected by three types of fixed prosthesis, was fabricated to study these tensions. Forces of different intensity will be exerted over three different points of the prosthesis and we will compare the distribution pattern of the generated tensions in each situation (AU)


Assuntos
Humanos , Análise do Estresse Dentário/métodos , Implantação Dentária/métodos , Elasticidade , Força de Mordida , 28574
11.
Rehabilitación (Madr., Ed. impr.) ; 40(5): 235-240, sept. 2006. ilus, graf
Artigo em Es | IBECS | ID: ibc-051057

RESUMO

Introducción. Los campos electromagnéticos están en investigación desde hace décadas. Actúan, principalmente, mediante el fenómeno piezoeléctrico, factor clave del desarrollo normal y remodelado óseo. Nuestro objetivo fue la búsqueda de los efectos de dos tipos de campos electromagnéticos, variables en el tiempo, sobre las características biomecánicas del hueso en crecimiento en conejos sanos. Material y método. El estudio fue realizado siguiendo las normas de la Comunidad Europea sobre la investigación animal. Usamos 34 conejos de raza híbrida Grande Español, con cuatro meses de edad. Se dividieron en un grupo control y dos grupos de tratamiento, el primero con campos electromagnéticos mediante bobinas de Helmholtz dispuestas en paralelo, y el segundo en el interior de un solenoide. Se sometieron a 18 sesiones de una hora de duración cada una en días alternos. Las patas traseras, obtenidas tras sacrificar a los animales, fueron analizadas biomecánicamente. Estudiamos la carga, la extensión y el esfuerzo flector de rotura, módulo de elasticidad, esfuerzo de abandono de la primera zona elástica y relación entre extensión de la zona elástica y total hasta la rotura. Resultados. Se obtuvieron datos estadísticamente significativos para el esfuerzo de abandono de la primera zona elástica en los grupos primero y segundo, y para el esfuerzo flector de rotura en el primer grupo. Conclusiones. Nuestros datos indican la necesidad de una mayor carga para llegar al punto en el que el hueso presentara una deformación residual al retirar el esfuerzo ejercido tras la aplicación de campos electromagnéticos. Se podría afirmar que probablemente tras la aplicación de campos electromagnéticos pulsados al tejido óseo de animales en crecimiento conseguiríamos un hueso más elástico


Introduction. The electromagnetic fields have been under research for decades. They mainly act by piezoelectric phenomenon, a clear factor of normal development and bone remodelling. Our objective was to discover the effects of two types of electromagnetic fields, variables in time, on the biomechanical characteristics of the growing bone, in healthy rabbits. Material and methods. The study was conducted following the Europeas Comunity guidelines on animal research. We used 24 rabbits of the Spanish Giant hybrid race, with four months of age. They were divided into a control group and two treatment groups, the 1st with electromagnetic fields by Helmholtz coils arranged in parallel and the 2nd in the inside of an solenoid. They were subjected to 18 sessions of one hour long each one, on alternate days. The back lags, obtained after sacrificing the animals, were analyzed biomechanically. We studied: load, extension and flexural break stress, elasticity module, abandonment stress of the first elastic zone and relationship between extension of the elastic zone and total zone to the rupture. Results. Statistically significant data were obtained for the abandonment stress of the first elastic zone in groups 1 and 2 and for the flexural break stress in-group 1. Conclusions. Our data indicate the need of greater load to reach the point in which the bone would have a residual deformation on withdrawing force applied after the application of electromagnetic fields. It could be stated that we would probably achieve a more elastic bone after the application of pulsed electromagnetic fields to the bone tissue of growing animals


Assuntos
Animais , Coelhos , Campos Eletromagnéticos , Tíbia/fisiologia , Fenômenos Biomecânicos , Resistência à Tração/fisiologia , Suporte de Carga/fisiologia , Fatores de Tempo , Elasticidade
12.
Rev. esp. cardiol. (Ed. impr.) ; 59(7): 679-687, jul. 2006. ilus, tab
Artigo em Es | IBECS | ID: ibc-048569

RESUMO

Introducción y objetivos. No se ha establecido si las técnicas de criopreservación permiten mantener las propiedades viscoelásticas vasculares y si los homoinjertos criopreservados presentan mayor similitud biomecánica con las arterias nativas que las prótesis más utilizadas. Los objetivos fueron: a) evaluar la capacidad de la metodología de criopreservación utilizada para mantener las propiedades viscoelásticas y funcionales de homoinjertos arteriales y venosos criopreservados, y b) analizar la similitud de los homoinjertos y de otros sustitutos actualmente utilizados (venas safenas y politetrafluoroetileno expandido [ePTFE]) con arterias femorales de pacientes receptores. Métodos. Se midieron la presión (tonometría), el diámetro y el espesor parietal (ecografía) en 15 arterias musculares (femorales) de pacientes mediante métodos no invasivos. In vitro, en condiciones hemodinámicas similares a las de los pacientes, se midieron la presión, el diámetro y el espesor en 15 segmentos frescos y 15 segmentos criopreservados de arterias musculares (femorales) y venas safenas humanas, y en 15 prótesis de ePTFE. Se utilizó el modelo Kelvin-Voigt para obtener los índices presión-diámetro, elástico (Epd, mmHg/mm) y viscoso (Vpd, mmHg·s/mm), y se cuantificó la función de amortiguamiento parietal como Vpd/Epd, y la función de conducción como 1/Zc (Zc: impedancia característica). Se calcularon el módulo de Young incremental y elástico presión-deformación y la velocidad del pulso. Resultados. Los homoinjertos frescos y criopreservados no mostraron diferencias viscoelásticas ni funcionales. Los homoinjertos arteriales presentaron la mayor similitud viscoelástica y funcional con las arterias de pacientes. Conclusiones. La criopreservación mantuvo las propiedades viscoelásticas y funcionales de homoinjertos arteriales y venosos. Los homoinjertos arteriales presentaron la mayor similitud con las arterias femorales nativas


Introduction and objectives. It is not yet known whether cryopreservation enables vessels to retain their viscoelastic properties or whether cryopreserved homografts are biomechanically more like native arteries than currently used vascular prostheses. The study objectives were: a) to determine whether our cryopreservation methodology enables arterial and venous homografts to retain their viscoelastic and functional properties; and b) to assess similarities between patients' femoral arteries, homografts, and other vascular prostheses in common use. Methods. The pressure and the diameter and parietal thickness of 15 muscular (femoral) arteries were measured in patients using tonometry and echography, both noninvasive techniques. In addition, the pressure in and diameter and parietal thickness of 15 fresh and 15 cryopreserved human muscular (femoral) artery segments, saphenous veins, and 15 expanded polytetrafluoroethylene (ePTFE) vascular prostheses were measured in vitro under hemodynamic conditions similar to those in patients. A Kelvin-Voigt model of the segment wall was used to derive elastic (Epd, mm Hg/mm) and viscous (Vpd, mm Hg·s/mm) pressure-diameter indices, the buffering function (Vpd/Epd), and the conduit function (1/Zc, where Zc is the characteristic impedance). The incremental Young modulus, the pressure-strain elastic modulus, and pulse wave velocity were also calculated. Results. No difference was observed between either the viscoelastic or functional properties of fresh and cryopreserved homografts. Arterial homografts were the most similar to the patient's arteries. Conclusions. Cryopreservation enabled venous and arterial homografts to retain their viscoelastic and functional properties. Of all the grafts investigated, arterial homografts were most similar, both biomechanically and functionally, to the patient's femoral arteries


Assuntos
Humanos , Criopreservação , Viscosidade , Politetrafluoretileno/uso terapêutico , Prótese Vascular , Velocidade do Fluxo Sanguíneo/fisiologia , Artéria Femoral/fisiologia , Artéria Femoral/transplante , Elasticidade , Hemodinâmica/fisiologia , Transplante Homólogo , Vasoconstrição , Vasodilatação , Manometria
15.
Rev. esp. cardiol. (Ed. impr.) ; 58(2): 167-174, feb. 2005. tab
Artigo em Es | IBECS | ID: ibc-037160

RESUMO

Introducción y objetivos. Variaciones regionales en la incidencia de diversas afecciones vasculares se han relacionado con diferencias regionales en la viscoelasticidad arterial. El objetivo de este trabajo fue caracterizar las diferencias regionales en el módulo elástico, viscoso y en el amortiguamiento parietal de arterias sistémicas, centrales y periféricas, mediante el análisis de la relación instantánea presión-diámetro arterial en el dominio temporal. Material y método. Se midieron la presión y el diámetro en 7 segmentos arteriales extraídos de 6 ovejas: carótida, tronco braquiocefálico, aorta ascendente, aorta torácica descendente proximal, media y distal, y arteria femoral. Cada segmento fue montado en un sistema circulatorio in vitro y perfundido con solución Tyrode, con frecuencia de estimulación de 1,8 Hz y valores de presión sistémica. Utilizando un modelo Kelvin-Voigt, se obtuvieron el módulo presión-diámetro elástico (Epd, mmHg/mm)y viscoso (Vpd, mmHg×s/mm), y se cuantificó la función de amortiguamiento parietal (FAP) como Vpd/Epd. Adicionalmente, se calculó el módulo de Young incremental y elástico presión-deformación y la velocidad de onda del pulso de cada segmento. Resultados. Los módulos elásticos y viscoso aumentaron hacia los segmentos periféricos, mientras que la FAPn o mostró diferencias entre segmentos. La menor rigidez en las arterias centrales y la mayor viscosidad en las arterias periféricas podrían indicar que la función de reservorio arterial sistólico se concentra en las primeras y la disipación viscosa de energía en las segundas. Conclusiones. La respuesta elástica y viscosa arterial podrían considerarse dependientes de la región arterial, mientras que la constante de FAP sería un indicador independiente de la región arterial


Introduction and objectives. Regional variations in the incidence of vascular diseases have been related to regional differences in arterial viscoelasticity. The aim of this study was to characterize the differences in the elastic and viscous modulus and in wall buffering function between central and peripheral systemic arteries, through a time-series analysis of the pressure-diameter relationship. Material and method. Pressure and diameter were measured in seven arterial segments (carotid, brachiocephalic trunk, ascending aorta, proximal, middle and distal descending thoracic aorta, and femoral artery) from sixs heep. Each segment was mounted on an in vitro mock circulatory system and perfused with Tyrode solution, with a pulse frequency of 1.8 Hz and systemic pressure levels. We used the Kelvin-Voigt model to calculate the pressure-diameter elastic (Epd, mmHg/mm) and viscous (Vpd,mmHg•s/mm) modulus, and to quantify the local wall buffering function (Vpd/Epd). We also calculated the incremental Young’s and pressure-strain elastic modulus and pulse wave velocity for each segment. Results. The elastic and viscous modulus increased from proximal to distal segments. The wall buffering function did not differ significantly between arteries. The lower rigidity of the central arteries compared to the distal ones may indicate that the systolic arterial compliance function is concentrated in the central arterial segments. On the other hand, the greater viscosity in the distal segments may indicate that viscous energy loss is concentrated in these segments. Conclusions. Arterial elasticity and viscosity can be interpreted as properties that are dependent on the region of the vessel, whereas wall buffering function can be considered region-independent


Assuntos
Artérias/fisiologia , Elasticidade , Viscosidade , Fenômenos Biomecânicos , Fenômenos Fisiológicos Cardiovasculares , Pulso Arterial , Ovinos
16.
Ars pharm ; 45(1): 59-71, ene. 2004. tab, ilus
Artigo em En | IBECS | ID: ibc-32176

RESUMO

El comportamiento biomecánico de la piel humana in vivo es un indicador importante de una buena condición cutánea en lo que es su organización funcional. Los tejidos subyacentes también contribuyen a estas propiedades, lo que imposibilita una evaluación estrictamente biomecánica de este comportamiento. Ocurre además, que los sistemas tecnológicos corrientemente utilizados para este tipo de evaluación in vivo, no permiten obtener la medida directa de las características biofísicas del órgano, ya que no es posible cuantificar la contribución relativa de cada tejido para este comportamiento. Las variables y los parámetros obtenidos deben ser, sobre todo, considerados como "descriptores" mecánicos, lo que enfatiza el cuidado especial que hay que tener al interpretar su variación. También por este motivo una de las preguntas fundamentales en relación a la contribución relativa de la epidermis a este comportamiento, sigue aun mal esclarecida. El presente protocolo fue elaborado en este complejo marco para responder, en especial, a esta última cuestión a través de dos diferentes tratamientos tópicos susceptibles de modificar el equilibrio hídrico de la epidermis de voluntarios sanos (agua corriente y una solución al 10 por ciento de glicerina), registrándose la respectiva respuesta biológica. Los resultados obtenidos sugieren que el comportamiento biomecánico de la piel in vivo puede ser modificado y eventualmente modulado a través de intervenciones tópicas, proponiendo que la epidermis influencia de hecho el comportamiento biomecánico global de toda la piel (AU)


Assuntos
Adulto , Feminino , Masculino , Humanos , Fenômenos Biomecânicos , Epiderme , Pele/anatomia & histologia , Pele/fisiologia , Protocolos Clínicos/classificação , Envelhecimento da Pele , Envelhecimento da Pele/fisiologia , Estatísticas não Paramétricas , Elasticidade , Biofísica/métodos , Biofísica/organização & administração , Glicerol/administração & dosagem , Glicerol/uso terapêutico
17.
Rev. esp. cardiol. (Ed. impr.) ; 56(12): 1202-1209, dic. 2003.
Artigo em Es | IBECS | ID: ibc-28275

RESUMO

Introducción y objetivos. Determinar la viscosidad y elasticidad de las arterias aorta y pulmonar y el efecto de la activación del músculo liso vascular sobre la capacidad de amortiguamiento arterial. Material y método. En 6 ovejas anestesiadas se midieron la presión y el diámetro aórtico y pulmonar, en condiciones basales y de hipertensión: a) pasiva, mediante la oclusión mecánica vascular, y b) activa, mediante fenilefrina intravenosa. Se calcularon la elasticidad y viscosidad parietal y se caracterizó la capacidad de amortiguamiento: a) la parietal, mediante el cociente viscosidad/elasticidad, y b) la global de cada circuito mediante la constante de tiempo de descenso de la presión arterial diastólica. Resultados. La viscoelasticidad aórtica fue mayor que la pulmonar (p < 0,05), mientras que ambas arterias tuvieron un amortiguamiento parietal similar. El circuito sistémico presentó un mayor amortiguamiento global (p < 0,05). Durante la hipertensión pasiva se produjo un aumento significativo de la elasticidad sin cambios en la viscosidad, lo que determinó una reducción significativa del amortiguamiento parietal, mientras que el amortiguamiento global de cada circuito disminuyó significativamente. En la hipertensión activa aumentó la viscosidad (p < 0,05), mientras que el amortiguamiento parietal y global recuperaron los valores basales. Conclusiones. La aorta presentó mayor viscoelasticidad que la arteria pulmonar, con un amortiguamiento parietal similar. El amortiguamiento global sistémico fue mayor que el pulmonar. Mientras que la elasticidad depende de la presión intravascular, la viscosidad es un marcador de la activación muscular. La activación muscular resultaría beneficiosa para el sistema cardiovascular, al mantener las funciones de amortiguamiento parietal y global (AU)


Assuntos
Animais , Ovinos , Músculo Liso Vascular , Artéria Pulmonar , Aorta Torácica , Fenômenos Biomecânicos , Elasticidade
18.
Av. odontoestomatol ; 19(6): 291-297, nov.-dic. 2003. tab
Artigo em Es | IBECS | ID: ibc-28604

RESUMO

Objetivo: Determinar la resistencia a la flexión y el módulo de elasticidad de cinco resinas compuestas: Tetric Ceram, Ecusit, Spectrum TPH, Filtek Z-250, Degufill mineral; y dos resinas modificadas con poliácidos: Luxat e Ionosit. Material y método: Se prepararon cinco muestras de cada material en un molde metálico rectangular (22x2x2 mm). Las muestras fueron polimerizadas, primero en el centro y luego en ambos extremos con una lámpara de luz halógena y después se conservaron en agua a 37° C durante 48 horas. Las muestras se pulieron para eliminar la capa de resina superficial y se sometieron al ensayo de flexión en 3 puntos con una máquina de tracción universal Instron con una velocidad de travesaño del mm/min. Los resultados (MPa) fueron analizados mediante los tests de AMOVA y Student-Newman-Keuls (p<0.05). Resultados: La resistencia a la flexión y el módulo de elasticidad de la resina compuesta modificada con poliácidos Ionosit fueron significativamente menores que los determinados para los demás materiales evaluados (AU)


The aim of this study was to determine the flexural strength and modulus of elasticity of five resin composites: Tetric Ceram, Ecusit, Spectrum TPH, Filtek Z-250, Degufill mineral; and two polyacid-modified resin composites: Luxat e lonosit. Five rectangular specimens of each material were prepared (22x2x2 mm). They were light-cured, first in the middle and after in both extremes, by means of a visible-light curing unit. The specimens were stored in water at 37° C for 48 hours and ground to eliminate the resin layer inhibited by oxygen. Three-point bending test was performed in an universal testing machine (Instron) at a cross-head speed of 1mm/min. Results were expressed in MPa and analysed by ANOVA and Student-Newman-Keuls tests (p<0.05). Flexural strength and modulus of elasticity of the polyacid-modified resin composite, lonosit, were significantly lower than the values obtained for the rest of the materials evaluated (AU)


Assuntos
Humanos , Compômeros/uso terapêutico , Restauração Dentária Permanente/métodos , Compômeros/química , Elasticidade , Cimentos de Ionômeros de Vidro/uso terapêutico , Maleabilidade , Resistência à Tração
19.
An. R. Acad. Farm ; 68(2): 251-264, abr. 2002. tab, graf
Artigo em Es | IBECS | ID: ibc-23768

RESUMO

En el presente trabajo se ha estudiado la influencia del aumento de la plasticidad en la liberación de un anti-inflamatorio no esteroideo (Fentiazac) vehiculado en gel, en función del tiempo y temperatura de almacenaje. A través de ensayos reológicos y de liberación in vitro utilizando membranas epidérmicas artificiales (SARTORIUS), se concluye que estos dos parámetros (tiempo y temperatura de almacenaje) influyen en el comportamiento reológico del producto y, consecuentemente, en la liberación del anti-inflamatorio (AU)


Assuntos
Anti-Inflamatórios não Esteroides/farmacocinética , Armazenamento de Medicamentos/métodos , Anti-Inflamatórios/farmacocinética , Reologia/métodos , Elasticidade , Géis/análise , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA