Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 208
Filtrar
1.
Int. j. morphol ; 41(3): 804-810, jun. 2023. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1514282

RESUMO

SUMMARY: The preserved form of all components of the nerve fiber is a prerequisite for the proper conduction of the nerve impulse. various factors can change the shape of nerve fibers. In everyday practice, qualitative histological analysis is the gold standard for detecting changes in shape. Geometric morphometry is an innovative method that objectively enables the assessment of changes in nerve fibers' shape after local anesthetics action. A total of sixty sciatic nerves were used as material, which was intraneural injected with saline solution in the control group (n=30), and a solution of 1.33 % liposomal bupivacaine (n=30) in the test group. After the animals were sacrificed, nerve samples were taken and histological preparations were made. The preparations were first described and examined using a qualitative histological method, after which digital images were made. The images were entered into the MorphoJ program and processed using the method of geometric morphometry. Qualitative histological examination revealed no differences in nerve fibers after intraneurally applied physiological solution and liposomal bupivacaine. Using the method of geometric morphometry, a statistically significant change in the shape of axons was found after intraneurally applied saline solution and liposomal bupivacaine (p=0.0059). No significant differences in histological changes were found after the qualitative histological analysis of nerve fiber cross-section preparations. A statistically significant change in the shape of nerve fiber axons was observed after geometric morphometric analysis of digital images after intraneural application of saline and liposomal bupivacaine.


La forma conservada de todos los componentes de la fibra nerviosa es un requisito previo para la conducción correcta del impulso nervioso. Varios factores pueden cambiar la forma de las fibras nerviosas. En la práctica diaria, el análisis histológico cualitativo es el estándar de oro para detectar cambios de forma. La morfometría geométrica es un método innovador que permite evaluar objetivamente los cambios en la forma de las fibras nerviosas después de la acción de los anestésicos locales. Se utilizó como material un total de sesenta nervios ciáticos, que se inyectaron intraneuralmente con solución salina en el grupo control (n=30), y una solución de bupivacaína liposomal al 1,33 % (n=30) en el grupo de prueba. Después de sacrificados los animales, se tomaron muestras de nervios y se realizaron preparaciones histológicas. Primero se describieron y examinaron las preparaciones utilizando un método histológico cualitativo, después de lo cual se tomaron imágenes digitales. Las imágenes fueron ingresadas al programa MorphoJ y procesadas mediante el método de morfometría geométrica. El examen histológico cualitativo no reveló diferencias en las fibras nerviosas después de la aplicación intraneural de solución fisiológica y bupivacaína liposomal. Usando el método de morfometría geométrica, se encontró un cambio estadísticamente significativo en la forma de los axones después de la aplicación intraneural de solución salina y bupivacaína liposomal (p = 0,0059). No se encontraron diferencias significativas en los cambios histológicos después del análisis histológico cualitativo de las preparaciones de secciones transversales de fibras nerviosas. Se observó un cambio estadísticamente significativo en la forma de los axones de las fibras nerviosas después del análisis de morfometría geométrica de imágenes digitales después de la aplicación intraneural de solución salina y bupivacaína liposomal.


Assuntos
Animais , Ratos , Bupivacaína/administração & dosagem , Técnicas Histológicas/métodos , Anestésicos Locais/administração & dosagem , Fibras Nervosas/efeitos dos fármacos , Análise Discriminante , Ratos Wistar , Análise de Componente Principal , Solução Salina/administração & dosagem , Injeções , Lipossomos/administração & dosagem
2.
Int. j. morphol ; 40(6): 1594-1601, dic. 2022. ilus, tab, graf
Artigo em Inglês | LILACS | ID: biblio-1421826

RESUMO

SUMMARY: Anatomy education has gathered together a great many of many new modalities and was modified from classical lecture-based and laboratory practice system to the blended modules. In the scope of the present study, we develop a new, practical, cost- effective and efficient three dimensional (3D) educational model, which aimed to be helpful for the detection and better understanding of basic neuroanatomy education. Tractographic imaging, fiber dissection, microscopic anatomy and plastination techniques were applied to the white matter regions of the two brains. After the photographs that were taken were converted to 3D images, the specimens were plastinated. By way of establishing an educational model as a whole, we applied it to 202 second-year medical students. The students were separated into two groups when they attended to the theoretical lecture. Group 1 took the classical laboratory education; on the other hand, Group 2 received the newly designed educational model. Pre and post-tests were introduced to each group before and after laboratory sessions, respectively. The success scores were put to comparison. The average achievement scores of each group showed increase significantly (p<0.05) after the laboratory sessions, besides the increase in the post-test results of Group 2 was more statistically significant (p<0.05). Consequently, this new educational model enriched by newly designed unified methods could be regarded as useful for grasping and improving the basic neuroanatomy knowledge.


La educación en anatomía ha reunido una gran cantidad de nuevas modalidades, modificándose el sistema clásico de la práctica del laboratorio y de las clases basadas en conferencias, hacia los módulos combinados. En el ámbito del presente estudio, desarrollamos un modelo educativo tridimensional (3D) nuevo, práctico, rentable y eficiente, que pretendía ser útil para la detección y una mejor comprensión de la educación básica en neuroanatomía. Se tomaron imágenes tractográficas, disección de fibras, anatomía microscópica y técnicas de plastinación en los cerebros. Después de convertir las fotografías que se tomaron en imágenes 3D, se plastinaron los especímenes. A modo de establecer un modelo educativo en su conjunto, lo aplicamos a 202 estudiantes de segundo año de medicina. Los estudiantes fueron separados en dos grupos cuando asistieron a la clase teórica. El Grupo 1 tomó la educación clásica de laboratorio; por su parte, el Grupo 2 recibió el nuevo modelo educativo diseñado para el estudio. Se introdujeron pruebas previas y posteriores a cada grupo, antes y después de las sesiones de laboratorio. Se compararon las puntuaciones. Los puntajes promedio de rendimiento de cada grupo mostraron un aumento significativo (p<0,05) después de las sesiones de laboratorio. Además, se obtuvo un aumento en los resultados positivos, posteriores a la prueba del Grupo 2, siendo estadísticamente significativo (p<0,05). En consecuencia, este modelo educativo, enriquecido por métodos unificados de nuevo diseño, podría considerarse útil para captar y mejorar los conocimientos básicos de neuroanatomía.


Assuntos
Humanos , Modelos Educacionais , Educação Médica/métodos , Neuroanatomia/educação , Dissecação , Cérebro/anatomia & histologia , Imagem de Tensor de Difusão , Substância Branca/anatomia & histologia , Plastinação , Microscopia , Fibras Nervosas
3.
Rev. bras. oftalmol ; 81: e0069, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1407675

RESUMO

ABSTRACT Objective: To evaluate structural and visual field (VF) changes after ≥1 year of a single acute primary angle closure (APAC) attack using spectral-domain optical coherence tomography (SD-OCT) and standard automated perimetry (SAP). Methods: Patients with a single unilateral APAC crisis at least 1 year ago were included consecutively from 2013 to 2016. Contralateral eye was used as control. All patients underwent ophthalmic examination, RNFL imaging by SD-OCT, and SAP using Octopus 1-2-3. Results: 54 eyes (27 patients) were enrolled. Male-to-female ratio was 1:2. Mean time for the SD-OCT and SAP assessment after the crisis was 5.0±5.1 (1.0-23.5) years, and IOP was 52.5±9.8 mmHg. In APAC eyes, the thicknesses of all quadrants of peripapillary RNFL (36.3%; P<0.001) and some macular sections (from 2.1% to 4.7%; P<0.01) were reduced compared to contralateral eyes. Additionally, in APAC eyes, the mean defect on VF was negatively and statistically correlated with the reduction of all quadrants of peripapillary RNFL thickness. Conclusion: A single episode of APAC was associated with peripapillary RNFL and macular thickness and with VF defects after ≥1 year of the crisis in the affected eye. Statistically meaningful correlations were found between structural and functional damage.


RESUMO Objetivo: Avaliar alterações estruturais e do campo visual 1 ano ou mais após uma crise única de fechamento angular primário agudo utilizando tomografia de coerência óptica de domínio espectral e perimetria automatizada padronizada. Métodos: Pacientes que apresentaram crise unilateral única de fechamento angular primário agudo há pelo menos 1 ano foram consecutivamente incluídos entre 2013 e 2016. Os olhos contralaterais foram utilizados como controles. Todos os pacientes foram submetidos a exame oftalmológico, avaliação das camadas de fibras nervosas da retina utilizando tomografia de coerência óptica de domínio espectral e perimetria automatizada padronizada com o Octopus 1-2-3. Resultados: Foram incluídos 54 olhos (27 pacientes) com razão homem:mulher de 1:2. O tempo médio após a crise foi de 5,0±5,1 anos (1,0 a 23,5) e a pressão intraocular na crise foi 52,5±9,8mmHg. Nos olhos com fechamento angular primário agudo, todas as espessuras das camadas de fibras nervosas da retina peripapilares (36,3%; p<0,001) e de algumas seções maculares (de 2,1 a 4,7%; p<0,01) estavam reduzidas em comparação aos olhos contralaterais. Além do mais, nos olhos submetidos a fechamento angular primário agudo, o mean defect do campo visual foi estatisticamente e negativamente correlacionado com a redução da espessura de todos os quadrantes peripapilares da camada de fibras nervosas da retina. Conclusão: Um único episódio de fechamento angular primário agudo foi associado com redução na espessura da camada de fibras nervosas da retina peripapilar e da espessura macular e com defeitos de campo visual 1 ano ou mais após a crise no olho afetado. Correlações estatisticamente significativas foram identificadas entre danos estruturais e funcionais.


Assuntos
Humanos , Masculino , Feminino , Disco Óptico/patologia , Glaucoma de Ângulo Fechado/diagnóstico por imagem , Doenças do Nervo Óptico/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Fibras Nervosas/patologia , Campos Visuais , Glaucoma de Ângulo Fechado/complicações , Doenças do Nervo Óptico/etiologia , Doença Aguda , Iridectomia , Testes de Campo Visual , Pressão Intraocular , Macula Lutea
4.
Rev. colomb. radiol ; 33(1): 5697-5704, mar. 2022. imag
Artigo em Inglês, Espanhol | LILACS, COLNAL | ID: biblio-1428760

RESUMO

Los recientes avances en los equipos de ultrasonido y de sus transductores han permitido la mayor competitividad del método, posicionándose como la primera opción sobre otras modalidades de imagen en la valoración de las enfermedades de los tendones y nervios, gracias al incremento en la resolución para visualizar y explorar los tendones y los nervios periféricos. El ultrasonido (US) se consideraba un complemento de la resonancia magnética (RM); sin embargo, con los equipos modernos, se ha convertido en la mejor modalidad diagnóstica para la revisión de los nervios periféricos, aceptada cada día más, debido a la rapidez, disponibilidad y la característica dinámica del método ecográfico. La desventaja principal es que depende del operador y que la experiencia de quien lo realiza es fundamental para su adquisición e interpretación. Este trabajo muestra una breve revisión de la técnica y de los marcadores anatómicos en la valoración de los nervios periféricos más comunes de la extremidad inferior.


Recent advances in ultrasound technology and the development of high-resolution ultrasound transducers have enabled detailed depiction of superficial musculoskeletal structures, tendons and nerves, allowing the method to become more competitive, positioning it as the first choice over other imaging modalities in the assessment of tendon and nerve diseases. While in the past considered as complementary to magnetic resonance (MR) imaging, modern ultrasound has clearly become competitive. It is now the imaging modality of choice for evaluating tendon and neural pathology. The major advantages of ultrasound include dynamic evaluation of structures, low cost and wide availability. The main disadvantage is a high degree of operator dependency and the experience of the operator is essential for its acquisition and interpretation. This article reviews the technique and anatomical markers in the ultrasound appearance of the most common peripheral nerves of the lower limb.


Assuntos
Ultrassom , Extremidade Inferior , Fibras Nervosas
5.
Rev. bras. oftalmol ; 81: e0103, 2022. graf
Artigo em Inglês | LILACS | ID: biblio-1407672

RESUMO

ABSTRACT Optical coherence tomography is often used for detection of glaucoma as well as to monitor progression. This paper reviews the most common types of artifacts on the optical coherence tomography report that may be confused with glaucomatous damage. We mainly focus on anatomy-related artifacts in which the retinal layer segmentation and thickness measurements are correct. In such cases, the probability maps (also known as deviation maps) show abnormal (red and yellow) regions, which may mislead the clinician to assume disease is present. This is due to the anatomic variability of the individual, and the normative database must be taken into account.


RESUMO A tomografia de coerência óptica é frequentemente usada para detectar glaucoma, bem como para monitorar a progressão. Este artigo analisa os tipos mais comuns de artefatos no relatório de tomografia de coerência óptica que podem ser confundidos com danos glaucomatosos. Nós nos concentramos principalmente nos artefatos relacionados à anatomia em que a segmentação da camada da retina e as medidas de espessura estão corretas. Nesses casos, os mapas de probabilidade (também conhecidos como mapas de desvio) mostram regiões anormais (vermelho e amarelo), o que pode induzir o clínico em erro ao supor que a doença está presente. Isto se deve à variabilidade anatômica do indivíduo, e o banco de dados normativo deve ser levado em conta.


Assuntos
Humanos , Glaucoma/diagnóstico por imagem , Artefatos , Tomografia de Coerência Óptica/métodos , Postura , Retina/diagnóstico por imagem , Anormalidade Torcional , Movimentos da Cabeça , Erros de Diagnóstico , Movimentos Oculares , Fóvea Central , Fibras Nervosas/patologia
6.
Rev. bras. oftalmol ; 81: e0038, 2022. graf
Artigo em Inglês | LILACS | ID: biblio-1376777

RESUMO

ABSTRACT Myelinated retinal nerve fibers are rare congenital anomalies that appear as gray-white patches. They may be present in a syndrome characterized by ipsilateral myelinated retinal nerve fibers, myopia and amblyopia. The author reported an ellipsoid zone defect on spectral domain optical coherence tomography in a case of Straatsma syndrome without macular extension.


RESUMO Fibras nervosas retinais mielinizadas são anomalias congênitas raras que aparecem como manchas branco-acinzentadas. Eles podem se apresentar em uma síndrome caracterizada por fibras nervosas retinais mielinizadas ipsilaterais, miopia e ambliopia. O autor relatou um defeito na zona elipsoide na tomografia de coerência óptica de domínio espectral em um caso de síndrome de Straatsma sem extensão macular.


Assuntos
Humanos , Feminino , Adolescente , Doenças Retinianas/patologia , Doenças Retinianas/diagnóstico por imagem , Fibras Nervosas/patologia , Fibras Nervosas Mielinizadas/patologia , Disco Óptico , Ambliopia , Anormalidades do Olho/diagnóstico por imagem , Tomografia de Coerência Óptica , Fundo de Olho , Bainha de Mielina , Miopia
7.
Rev. bras. oftalmol ; 80(2): 96-99, Mar.-Apr. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1280112

RESUMO

ABSTRACT Purpose: to compare the Subfoveal choroidal thickness (SFCT) and Retinal Nerve Fiber Layer Thickness (RNFL) of amblyopic and normal fellow eyes. Design: Prospective, cross-sectional, observational case series. Methods: Forty patients age 12 to 41 years (mean 23.73 ± 6.42) with unilateral amblyopia were studied. Among them, 11(28.2%) patients had amblyopia secondary to strabismus and 29(71.8 %) had anisometropic amblyopia. Optical coherence tomography (OCT) of the peripapillary RNFL thickness of amblyopic and fellow eyes was performed. RNFL thickness measurements were taken from the superior, inferior, nasal and temporal quadrants in the peripapillary region. Also, subfoveal choroidal thickness (SFCT) was measured using spectral domain optical coherence tomography (SD-OCT). Results: Mean global RNFL thickness of the amblyopic and fellow eyes was 104.48 microns and 102.83 microns, respectively. The difference between the two groups was not statistically significant (p>0.05%). The thicknesses of the superior, inferior, nasal and temporal quadrants of the retinal nerve fiber layer between the amblyopic and normal fellow eyes showed no statistically significant difference (p>0.05%). However, the SFCT of amblyopic eye was 11 or more microns thicker than the fellow eye and this was statistically significant different (p<0.05%). Conclusions: This study demonstrated SFCT in amblyopic eyes was significantly thicker than the normal fellow eyes. The amblyopic process may involve the choroid, but not the prepapillary NFL.


RESUMO Objetivo: comparar a espessura da coroide subfoveal (CSF) e da camada de fibra nervosa retinal (CFNR) de olhos amblíopes e normais. Design: série de casos prospectivos, transversais e observacionais. Métodos: Quarenta pacientes com idade entre 12 e 41 anos (média 23,73 ± 6,42) com ambliopia unilateral foram estudados. Entre eles, 11 (28,2%) pacientes apresentavam ambliopia secundária a estrabismo e 29 (71,8%) apresentavam ambliopia anisometrópica. Foi realizada tomografia de coerência óptica (TCO) da espessura da CFNR peripapilar do olho amblíope e do outro olho. As medidas de espessura da CFNR foram realizadas nos quadrantes superior, inferior, nasal e temporal na região peripapilar. Além disso, a espessura da coroide subfoveal (CSF) foi medida através de tomografia de coerência óptica de domínio espectral (TCO-DE). Resultados: A espessura média global da CFNR do olho amblíope e do outro olho foi de 104,48 mícrons e 102,83 mícrons, respectivamente. A diferença entre os dois grupos não foi estatisticamente significativa (p > 0,05%). As espessuras dos quadrantes superior, inferior, nasal e temporal da camada de fibras nervosas da retina entre o olho amblíope e o normal não apresentaram diferença estatisticamente significativa (p > 0,05%). No entanto, a CSF do olho amblíope foi 11 mícrons mais espessa (ou mais) do que a do outro olho - essa diferença foi estatisticamente significativa (p < 0,05%). Conclusões: Este estudo demonstrou que a CSF dos olhos amblíopes foi significativamente mais espessa do que a dos olhos normais. O processo amblíope pode envolver a coroide, mas ele não envolve a CFNR peripapilar.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Ambliopia/complicações , Ambliopia/diagnóstico por imagem , Corioide/diagnóstico por imagem , Fibras Nervosas/patologia , Disco Óptico/patologia , Nervo Óptico/patologia , Tamanho do Órgão , Células Ganglionares da Retina/patologia , Acuidade Visual , Estudos Transversais , Estudos Prospectivos , Corioide/patologia , Tomografia de Coerência Óptica/métodos , Fóvea Central/patologia
9.
Arq. bras. oftalmol ; 83(5): 383-388, Sept.-Oct. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1131623

RESUMO

ABSTRACT Purpose: This study aimed to evaluate optic nerve head parameters and inner retinal layer thicknesses in obese children and adolescents. Methods: Forty-one eyes of 41 pediatric obese participants and 41 eyes of 41 age- and sex-matched healthy controls were included in this study. Body mass index was calculated, based on sex and age, using body weight and height measurements. Blood lipid values (i.e., cholesterol, low-density lipoprotein, high-density lipoprotein, and triglyceride) were measured in obese participants. Optical coherence tomography was used to examine optic nerve head parameters, including rim area, disc area, cup-to-disc ratio, and cup volume, as well as the thicknesses of retinal nerve fiber layers and macular ganglion cell-inner plexiform layers. Results: Optic disc parameters were similar in obese and healthy children (p>0.05). The percentage of binocular retinal nerve fiber layer thickness symmetry was significantly different between obese and control groups (p=0.003). Compared to the control group, participants in the obese group exhibited thinner retinal nerve fiber layers in the superior quadrants (p=0.04) and thinner ganglion cell-inner plexiform layers in the superior-temporal sectors (p=0.04). There were no statistically significant correlations between the ocular parameters and lipid blood test values assessed in this study (p>0.05). Body mass index was significantly negatively correlated with the mean retinal nerve fiber layer thickness (r=-0.33, p=0.03) in the obese group. There was no significant correlation between intraocular pressure and body mass index (r=0.05, p=0.74). Conclusion: Compared to healthy children, obese children had greater binocular retinal nerve fiber layer thickness asymmetry and thinner retinal nerve fiber and ganglion cell-inner plexiform layers in several sectors. Blood lipid levels were not associated with retinal thickness or optic disc parameters in obese children.


RESUMO Objetivo: O objetivo deste estudo foi avaliar os parâmetros da cabeça do nervo óptico e a espessura da camada interna da retina em crianças e adolescentes obesos. Métodos: Quarenta e um olhos de 41 participantes pediátricos obesos e 41 olhos de 41 controles saudáveis pareados por idade e sexo foram incluídos neste estudo. O índice de massa corporal foi calculado com base no sexo e na idade, utilizando medidas de peso e estatura corporal. Os valores de lipídios no sangue (colesterol, lipoproteína de baixa e alta densidade e triglicérides) foram medidos nos participantes obesos. A tomografia de coerência óptica foi usada para examinar os parâmetros da cabeça do nervo óptico, incluindo a área da borda, área do disco, razão escavação/disco, volume da escavação, espessura s camadas de fibra nervosa da retina e as camadas plexiformes internas das células ganglionares da mácula. Resultados: Os parâmetros do disco óptico foram semelhantes em crianças obesas e saudáveis (p>0,05). A porcentagem da simetria da espessura da camada de fibras nervosas da retina binocular foi significativamente diferente entre os grupos obesos e controle (p=0,003). Comparados ao grupo controle, os participantes do grupo obeso exibiram camadas mais finas de fibras nervosas da retina nos quadrantes superiores (p=0,04) e camadas plexiformes mais finas da célula ganglionar interna nos setores temporal superior (p=0,04). Não houve correlação significante entre os parâmetros oculares e os valores dos exames de sangue lipídico avaliados neste estudo (p>0,05). O índice de massa corporal foi significativamente correlacionado negativamente com a espessura média da camada de fibras nervosas da retina (r=-0,33, p=0,03) no grupo obeso. Não houve correlação significativa entre a pressão intraocular e o índice de massa corporal (r=0,05, p=0,74). Conclusão: Comparadas às crianças saudáveis, as crianças obe sas apresentaram maior assimetria binocular na espessura da ca mada de fibras nervosas da retina e fibras nervosas da retina mais finas e camadas plexiformes internas das células ganglionares em vários setores. Os níveis de lipídios no sangue não foram associados à espessura da retina ou aos parâmetros do disco óptico em crianças obesas.


Assuntos
Humanos , Adolescente , Adulto , Disco Óptico , Obesidade , Disco Óptico/anatomia & histologia , Disco Óptico/diagnóstico por imagem , Retina , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Fibras Nervosas , Obesidade/complicações
10.
Arq. bras. oftalmol ; 83(4): 269-276, July-Aug. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1131618

RESUMO

ABSTRACT Purpose: To evaluate the influence of ocular axial length on circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in healthy eyes after correcting for ocular magnification effect. Methods: In this cross-sectional study, we evaluated 120 eyes from 60 volunteer participants (myopes, emmetropes, and hyperopes). The thickness of the circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer were measured using the spectral optical coherence tomography (OCT)-Cirrus HD-OCT and correlated with ocular axial length. Adjustment for ocular magnification was performed by applying Littmann's formula. Results: Before the adjustment for ocular magnification, age-adjusted mixed models analysis demonstrated a significant negative correlation between axial length and average circumpapillary retinal nerve fiber layer thickness (r=-0.43, p<0.001), inferior circumpapillary retinal nerve fiber layer thickness (r=-0.46, p<0.001), superior circumpapillary retinal nerve fiber layer thickness (r=-0.31, p<0.05), nasal circumpapillary retinal nerve fiber layer thickness (r=-0.35, p<0.001), and average ganglion cell-inner plexiform layer thickness (r=-0.35, p<0.05). However, after correcting for magnification effect, the results were considerably different, revealing only a positive correlation between axial length and temporal retinal nerve fiber layer thickness (r=0.42, p<0.001). Additionally, we demonstrated a positive correlation between axial length and average ganglion cell-inner plexiform layer thickness (r=0.48, p<0.001). All other correlations were not found to be statistically significant. Conclusions: Before adjustment for ocular magnification, axial length was negatively correlated with circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness measured by Cirrus-OCT. We attributed this effect to ocular magnification associated with greater axial lengths, which was corrected with the Littman's formula. Further studies are required to investigate the impact of ocular magnification correction on the diagnostic accuracy of Cirrus-OCT.


RESUMO Objetivo: Avaliar a influência do comprimento axial ocular na espessura da camada de fibras nervosas da retina peripapilar e na espessura da camada de células ganglionares-plexiforme interna em olhos saudáveis após correção para efeito de magnificação ocular. Métodos: Neste estudo transversal, avaliamos 120 olhos de 60 participantes voluntários (míopes, emétropes e hipermétropes). A espessura da camada de fibras nervosas da retina peripapilar e da camada de células ganglionares-plexiforme interna foram medidas usando a tomografia de coerência óptica espectral (OCT)-Cirrus HD-OCT e correlacionada com o comprimento axial ocular. O ajuste para a magnificação ocular foi realizado aplicando a fórmula de Littmann. Resultados: Antes do ajuste para magnificação ocular, a análise de modelos mistos ajustada por idade demonstrou uma correlação negativa significante entre o comprimento axial e a espessura média da camada de fibras nervosas da retina peripapilar (r=-0,43; p<0,001), espessura da camada de fibras nervosas da retina peripapilar inferior (r=-0,46; p <0,001), espessura da camada de fibras nervosas da retina peripapilar superior (r=-0,31; p<0,05), espessura da camada de fibras nervosas da retina peripapilar nasal (r=-0,35; p<0,001) e espessura média das células ganglionares-plexiforme interna (r=-0,35; p<0,05). No entanto, após a correção do efeito de magnificação, os resultados foram consideravelmente diferentes, revelando apenas uma correlação positiva entre o comprimento axial e a espessura temporal da camada de fibras nervosas da retina(r=0,42; p<0,001). Além disso, demonstramos uma correlação positiva entre o comprimento axial e a espessura média das células ganglionares-plexiforme interna (r=0,48; p<0,001). Todas as outras correlações não foram consideradas estatisticamente significativas. Conclusão: Antes do ajuste para o efeito de magnificação ocular, o comprimento axial estava negativamente correlacionado com a espessura da camada de fibras nervosas da retina peripapilar e das células ganglionares-plexiforme interna medido pelo Cirrus-OCT. Atribuimos esse efeito à magnificação ocular associada a comprimentos axiais maiores, o que foi corrigido com a fórmula de Littman. Mais estudos são necessários para investigaro impactoda correçãoda magnificação ocular na acurácia diagnóstica do Cirrus-OCT.


Assuntos
Humanos , Tomografia de Coerência Óptica , Células Ganglionares da Retina , Glaucoma , Estudos Transversais , Fibras Nervosas
11.
Braz. J. Psychiatry (São Paulo, 1999, Impr.) ; 42(3): 309-313, May-June 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1132084

RESUMO

Objective: To compare intraocular pressure (IOP) and macular, retinal nerve fiber layer (RNFL), and ganglion cell layer (GCL) thicknesses in treatment-naive children with attention-deficit/hyperactivity disorder (ADHD), children with ADHD on regular methylphenidate (MPH) treatment for at least 3 months, and healthy controls. Methods: A total of 58 treatment-naive children with ADHD, 45 children with ADHD on regular MPH treatment, and 44 healthy controls were enrolled in this study. All participants underwent a comprehensive eye examination. Optical coherence tomography (OCT) was used to assess global RNFL thickness, central macular thickness, and GCL thickness in both eyes. Results: Separate univariate analysis of covariance (ANCOVA) on the outcome variables revealed a significant difference among the research groups with respect to IOP in the left eye. Post-hoc univariate analyses indicated that left IOP was significantly higher in children with ADHD under MPH treatment than among healthy controls. However, global RNFL thickness, central macular thickness, and GCL thickness of both eyes, as well as IOP in the right eye, were not significantly different across groups. Conclusion: Further longitudinal follow-up studies are needed to determine whether MPH treatment has any effect on IOP or OCT findings.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Células Ganglionares da Retina/patologia , Transtorno do Deficit de Atenção com Hiperatividade/fisiopatologia , Transtorno do Deficit de Atenção com Hiperatividade/patologia , Pressão Intraocular/fisiologia , Macula Lutea/patologia , Fibras Nervosas/patologia , Valores de Referência , Retina/patologia , Estudos de Casos e Controles , Análise de Variância , Tomografia de Coerência Óptica
12.
Arq. bras. oftalmol ; 83(2): 132-140, Mar.-Apr. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1088966

RESUMO

ABSTRACT Purpose: To investigate the relationships between (i) thickness of the retinal nerve fiber layer, optic nerve head topography, and visual field parameters and (ii) corneal biomechanical properties in normal controls and patients with ocular hypertension and primary open-angle glaucoma. Methods: This observational, cross-sectional study included 68 eyes with primary open-angle glaucoma, 99 eyes with ocular hypertension and 133 control eyes. Corneal biomechanical properties, optic nerve head topographic features, retinal nerve fiber layer thickness, and visual fields were assessed in all cases. Corneal biomechanical properties, retinal nerve fiber layer thicknesses, and optic nerve head topographic features were compared among the groups. The associations between structural and functional measures of glaucomatous damage and corneal biomechanical factors were also evaluated. Results: Significantly lower corneal hysteresis and corneal resistance factor values were observed in the primary open-angle glaucoma and ocular hypertension groups as compared with the control group, but there were no significant differences between the primary open-angle glaucoma and ocular hypertension groups. In the ocular hypertension group, no associations were observed between the corneal hysteresis and corneal resistance factor with values and the structural and functional parameters. In the primary open-angle glaucoma group, positive correlations were observed between the corneal hysteresis values and the global retinal nerve fiber layer thickness (p<0.01, r=0.27), mean retinal nerve fiber layer thickness (p<0.01, r=0.33), and mean deviation (p<0.01, r=0.26), and negative correlations were observed between the corneal resistance factor values, and the cup area (p<0.01, r=-0.39), cup-to-disk ratio (p=0.02, r=-0.28), linear cup-to-disk ratio (p=0.02, r=-0.28), and cup shape (p=0.03, r=-0.26). In the control group, weak correlations were detected between the corneal hysteresis and the cup area (p=0.03, r=0.19), cup-to-disk ratio (p=0.01, r=0.21), and linear cup-to-disk ratio (p=0.01, r=0.22). Conclusions: Distinct correlations were identified between the corneal hysteresis and corneal resistance factor values and the functional and structural parameters in the primary open-angle glaucoma and control groups. Corneal hysteresis and corneal resistance factor may have different roles in the pathophysiology of glaucoma.


RESUMO Objetivo: Investigar as relações entre (i) espessura da camada de fibras nervosas da retina, topografia do nervo óptico e parâmetros do campo visual e (ii) propriedades biomecânicas da córnea, em controles normais e pacientes com hiperten são ocular e glaucoma primário de ângulo aberto. Métodos: Este estudo observacional, transversal, incluiu 68 olhos com glaucoma primário de ângulo aberto, 99 olhos com hipertensão ocular e 133 olhos controle. As propriedades biomecânicas da córnea, as características topográficas da cabeça do nervo óptico, a espessura da camada de fibras nervosas da retina e os campos visuais foram avaliados em todos os casos. As propriedades biomecânicas da córnea, a espessura da camada de fibras nervosas da retina e as características topográficas da cabeça do nervo óptico foram comparadas entre os grupos. As associações entre medidas estruturais e funcionais de danos glaucomatosos e fatores biomecânicos da córnea também foram avaliadas. Resultados: Valores de histerese corneana e da resistência corneana foram significativamente menores nos grupos com glaucoma primário de ângulo aberto e hipertensão ocular em com paração ao grupo controle, mas não houve diferenças significativas entre os grupos de glaucoma primário de ângulo aberto e hipertensão ocular. No grupo com hipertensão ocular, não foram observadas associações entre histerese da córnea e o fator de resistência corneana com os valores e os parâmetros estruturais e funcionais. No grupo com glaucoma primário de ângulo aberto foram observadas correlações positivas entre os valores de histerese corneana e a espessura a camada de fibras nervosas da retina (p<0,01, r=0,27), espessura média da camada de fibras nervosas da retina (p<0,01, r=0,33) e desvio médio (p<0,01, r=0,26), e correlações negativas entre o os valores do fator de resistência da córnea e a área de escavação (p<0,01, r=-0,39), a relação escavação/disco (p=0,02, r=-0,28), a relação copo-para-disco linear (p=0,02, r=-0,28) e a forma da escavação (p=0,03, r=-0,26). No grupo controle, correlações foram detectadas entre a histerese da córnea e área de escavação (p=0,03, r=0,19), relação escavação/disco (p=0,01, r=0,21) e relação copo-para-disco linear (p=0,01, r=0,22). Conclusões: Correlações distintas foram identificadas entre histerese da córnea e os valores de resistência da córnea e os parâmetros funcionais e estruturais nos grupos de glaucoma primário de ângulo aberto e controle. A histerese da córnea e o fator de resistência da córnea podem ter diferentes papéis na fisiopatologia do glaucoma.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Retina/patologia , Glaucoma de Ângulo Aberto/patologia , Hipertensão Ocular/patologia , Córnea/patologia , Fibras Nervosas/patologia , Valores de Referência , Retina/fisiopatologia , Fenômenos Biomecânicos , Campos Visuais/fisiologia , Estudos de Casos e Controles , Modelos Lineares , Glaucoma de Ângulo Aberto/fisiopatologia , Hipertensão Ocular/fisiopatologia , Estudos Transversais , Córnea/fisiopatologia , Pressão Intraocular
13.
Rev. bras. oftalmol ; 78(6): 409-412, nov.-dez. 2019. tab, graf
Artigo em Português | LILACS | ID: biblio-1057910

RESUMO

Resumo A Síndrome de Wolfram consiste em uma patologia neurodegenerativa de caráter genético, também conhecida pela sigla DIDMOAD que traduz os principais achados dessa doença, Diabetes Insipidus, Diabetes Mellitus, Atrofia Óptica e Surdez. O artigo visa relatar ocaso de um paciente diagnosticado clinicamente com essa síndrome em um ambulatório geral de oftalmologia. Tendo em vistaque os pacientes portadores dessa alteração genética apresentam mais de um par craniano afetado e quadro clínico sem históricode meningite ou outras alterações neurológicas, tem-se que pensar em alterações raras, como é o caso dessa síndrome. A partir dodiagnóstico, aplicou-se o questionário WRUS em consulta, o qual permitiu a comparação do paciente abordado com dados obtidosinternacionalmente disponíveis na literatura.


Abstract Wolfram Syndrome consists of a neurodegenerative pathology of genetic character, also known by the acronym DIDMOAD that translates the main findings of this disease, Diabetes Insipidus, Diabetes Mellitus, Optic Atrophy and Deafness. The article report the case of a patient diagnosed clinically with this syndrome in a general ophthalmology out patient clinic. Considering that patients with this genetic alteration have more than one cranial nerve affected by the disease and clinical history without meningitis or other neurological alterations, one has to think about rare alterations, as is the case with this syndrome. From the diagnosis, the WRUS questionnaire was applied in consultation, which all owed the comparation of the patient with concepts obtained internationally available in the literature.


Assuntos
Humanos , Masculino , Adolescente , Síndrome de Wolfram/diagnóstico , Atrofia Óptica/diagnóstico , Doenças do Nervo Óptico/diagnóstico , Oftalmoscopia , Transtornos da Visão/diagnóstico , Síndrome de Wolfram/genética , Acuidade Visual , Defeitos da Visão Cromática , Tomografia de Coerência Óptica/métodos , Diabetes Mellitus Tipo 1 , Fundo de Olho , Perda Auditiva , Fibras Nervosas/patologia
14.
Arch. Clin. Psychiatry (Impr.) ; 46(5): 125-131, Sept.-Oct. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1054907

RESUMO

Abstract Background Optical coherence tomography (OCT) has been recently used to investigate neuropsychiatric disorders. Objective The aim of this study was to compare the retinal nerve fiber layer thickness (RNFLT) and the ganglion cell layer (GCL) volume in patients with type 1 bipolar disorder (BPD1, diagnosed according to DSM 5) to the values in healthy controls. Methods Eighty consecutive outpatients with a diagnosis of euthymic BPD1 and 80 healthy controls were enrolled in the study. Following assessment with the Sociodemographic Data Form, Structured Clinical Interview for DSM-IV (SCID-I), Hamilton Depression Scale and Young Mania Evaluation Scale, both groups underwent Optical coherence tomography (OCT). Results The mean RNFL thickness and mean GCL volume were significantly lower in the BPD1 group than in the controls (p < 0.05). The GCL global value had a significant and independent effect in distinguishing the BPD1 patients from the controls. A cut-off value of 101 mm3 for global GCL volume was proposed to distinguish BPD1 patients from controls with a sensitivity of 87.5%. Discussion Lower values of GCL volume and RNFLT in patients suffering from BPD1 suggest that neurodegeneration may occur during the course of BPD and that this degeneration can be characterized in particular by a thinning of the GCL volume.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Células Ganglionares da Retina/patologia , Transtorno Bipolar/diagnóstico por imagem , Tomografia de Coerência Óptica , Fibras Nervosas/patologia , Escalas de Graduação Psiquiátrica , Transtorno Bipolar/tratamento farmacológico , Inquéritos e Questionários , Análise de Regressão , Ácido Valproico/uso terapêutico , Ácido Valproico/farmacologia , Compostos de Lítio/uso terapêutico , Compostos de Lítio/farmacologia , Antimaníacos/uso terapêutico , Antimaníacos/farmacologia , Doenças Neurodegenerativas/prevenção & controle , Doenças Neurodegenerativas/diagnóstico por imagem , Entrevista Psicológica
15.
Rev. argent. radiol ; 83(3): 95-101, set. 2019. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1057407

RESUMO

Objetivo Desde la aparición de la tractografía, al tratarse de una técnica no invasiva y que usa la ampliamente conocida resonancia magnética (RM), el estudio de la sustancia blanca se ha facilitado. A partir de eso, se han logrado grandes descubrimientos en cuanto a fascículos cerebrales involucrados en funciones cognitivas. Sin embargo, su evaluación sigue siendo subjetiva y depende de la experiencia y entrenamiento del evaluador, razón por la cual se ha limitado su aplicabilidad en la práctica clínica. En ese sentido, es conveniente parametrizar volúmenes cerebrales de sustancia blanca en población sana a través de una herramienta electrónica que se pueda reproducir y así poderlo aplicar en enfermos. Materiales y métodos Se reportan 10 sujetos sanos desde el punto de vista neurológico. Para cada sujeto, se adquirieron imágenes ponderadas por difusión y los resultados se visualizaron mediante FiberNavigator (http://scilus.github.io/fibernavigator). Finalmente, esa misma herramienta fue utilizada para purificar los fascículos objeto de estudio y realizar el conteo de las fibras. Resultados Se obtuvieron valores de volumetría del fascículo longitudinal superior (FLS), fascículo longitudinal inferior (FLI), fascículo frontoccipital inferior (FFI), fascículo uncinado (FU) y fascículo del cíngulo (FC), identificando que no existen diferencias estadísticamente significativas entre el número de fibras que componen los fascículos cerebrales. Discusión Los resultados alcanzados de la anatomía y la direccionalidad de fibras de los fascículos cerebrales de este estudio coinciden con el resto de la evidencia publicada hasta el momento, sin encontrar diferencias en cuanto a su organización y recorrido. Conclusión Aunque esos resultados no sirven como valores de referencia para ser aplicados en pacientes con patología neurológica, brindamos información inexistente hasta el momento, con ese equipo en específico y la reproducción entre los distintos usuarios y el software.


Objective Since the appearance of tractography, as it is a non-invasive technique and uses the widely known magnetic resonance (MR), the study of white matter has been facilitated. After this, great discoveries have been made regarding the brain fascicles involved in cognitive functions. However, its evaluation continues to be subjective and depends on the evaluator's experience and training. That the reason why its applicability has been limited in clinical practice. Because of this, it is convenient to parametrize cerebral volumes of white matter in healthy population through an electronic, reproducible tool that could be applied in patients. Materials and Methods Ten neurologically healthy subjects are reported, for each subject we acquired images weighted by diffusion and the results were visualized by means of FiberNavigator (http://scilus.github.io/fibernavigator). Finally, this same tool was used to purify the fascicles under study and perform the fiber count. Results Volumetric values of the upper longitudinal fasciculus, inferior longitudinal fasciculus, inferior frontoccipital fasciculus, uncinated fasciculus and cingulate fasciculus were obtained, identifying that there are not statistically significant differences in the number of fibers that make up the cerebral fascicles. Discussion The results achieved of the anatomical and fiber directionality of the cerebral fascicles of this study, coincide with the rest of the evidence published up to now, without finding differences regarding its organization and route. Conclusion Although these results do not serve as reference values to be applied in patients with neurological pathology, do we provide nonexistent information so far, with this specific equipment and the reproducibility between the different users and the software.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Cognição/fisiologia , Substância Branca/diagnóstico por imagem , Valores de Referência , Anisotropia , Titulometria/normas , Imagem de Tensor de Difusão/normas , Fibras Nervosas
16.
Arq. bras. oftalmol ; 82(4): 263-269, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019422

RESUMO

ABSTRACT Purpose: To compare retinal and choroidal thickness in patients with Behçet's disease with and without ocular involvement as well as to evaluate the correlation between erythrocyte sedimentation rate and choroidal thickness among patients with Behçet's disease. Methods: This was a prospective interventional study investigating erythrocyte sedimentation as well as choroidal and retinal thickness among patients with Behçet's disease. Patients who were diagnosed based on The International Criteria for Behçet's Disease with (Group A) or without (Group B) ocular involvement and a matched control group (Group C) participated in the study. Optical coherence tomography measurements and blood tests were performed on the same day. Retinal and choroidal thickness were measured using spectral-domain optical coherence tomography (Spectralis, Heidelberg Engineering, Heidelberg, Germany), and central macular thickness, central subfoveal choroidal thickness, and retinal nerve fiber layer thickness were measured using optical coherence tomography. Results: Average erythrocyte sedimenta­tion values were 9.89 mm/h in Group A, 16.21 mm/h in Group B, and 3.89 mm/h in Group C; average central subfoveal choroidal thickness values were 350.66, 331.74, and 325.95 mm, respectively. Average central macular thickness and retinal nerve fiber layer thickness values of patients in Groups A, B and C were 226.39 and 225.97mm; 234.11 and 92.00 mm; and 97.58 and 99.84 mm, respectively. No significant difference was seen between Group A and B patients in central subfoveal choroidal thickness, central macular thickness, or retinal nerve fiber layer thickness values. Central macular thickness was statistically significantly thinner in Groups A and B than in Group C (p=0.016). Group A had thinning in the nasal quadrant of the retinal and general retinal nerve fiber layers when compared with those in Group C (p=0.010 and 0.041, respectively). A connection could not be established between the erythrocyte sedimentation, central subfoveal cho­roidal thickness, central macular thickness, and retinal nerve fiber layer thickness in the patients with Behçet's disease. Conclusion: The erythrocyte sedimentation rate is typically used to test for activation of Behçet's disease and assess treatment response. In our study, we could not establish a connection between the erythrocyte sedimentation rate and central subfoveal choroidal thickness, central macular thickness, and retinal nerve fiber layer thickness in patients with systematically active Behçet's disease without ocular involvement.


RESUMO Objetivos: Comparar a espessura da retina e da coroide em pacientes com doença de Behçet, com e sem acometimento ocular e avaliar a correlação entre a taxa de sedimentação de eritrócitos e a espessura da coroide em pacientes com doença de Behçet. Métodos: Estudo prospectivo intervencional que investigou a sedimentação de eritrócitos, espessura de coroide e da retina em pacientes com doença de Behçet. Os pacientes que foram diagnosticados com base nos Critérios Internacionais para a Doença de Behçet com (Grupo A) ou sem (Grupo B) envolvimento ocular e um grupo controle correspondente (Grupo C) participaram do estudo. Medidas de tomografia de coerência óptica e exames de sangue foram realizados no mesmo dia. As espessuras da retina e da coroide foram medidas utilizando tomografia de coerência óptica de domínio espectral (Spectralis, Heidelberg Engineering, Hidelberg, Germany) e a espessura macular central, a espessura coroidal subfoveal central e a espessura da camada de fibra nervosa da retina foram medidas usando tomografia de coerência óptica. Resultados: Os valores médios de sedimentação de eritrócitos foram de 9,89 mm/h no Grupo A, 16,21 mm/h no Grupo B e 3,89 mm/h no Grupo C; os valores médios da espessura da coroide subfoveal central foram 350,66, 331,74 e 325,95 mm respectivamente. Os valores médios da espessura macular central e da espessura da camada de fibra nervosa da retina dos pacientes nos grupos A, B e C foram de 226,39, 225,97, 234,11 mm e 92,00, 97,58, 99,84 mm respectivamente. Não houve diferença significativa entre pacientes do Grupo A e B na espessura da coroide subfoveal central, espessura macular central ou valores da espessura da camada de fibra nervosa da retina. A espessura macular central foi estatisticamente significativamente mais fina nos Grupos A e B do que no Grupo C (p=0,016). O Grupo A apresentou afinamento na porção nasal das camadas retiniana e geral da fibra nervosa da retina quando comparado com o Grupo C (p=0,010, p=0,041, respectivamente). Não foi possível estabelecer uma conexão entre a sedimentação dos eritrócitos, a espessura subfoveal central da coroide, a espessura macular central e espessura da camada de fibras nervosas da retina nos pacientes com doença de Behçet. Conclusão: A taxa de sedimentação de eritrócitos é comumente utilizada para testar a ativação da doença de Behçet e avaliar a resposta ao tratamento. Em nosso estudo, não foi possível estabelecer uma conexão entre a taxa de sedimentação de eritrócitos e a espessura da coroide subfoveal central, espessura macular central e espessura da camada de fibras nervosas da retina em pacientes com doença de Behçet sistematicamente ativa sem envolvimento ocular.


Assuntos
Humanos , Masculino , Feminino , Adulto , Retina/patologia , Sedimentação Sanguínea , Síndrome de Behçet/patologia , Síndrome de Behçet/sangue , Corioide/patologia , Valores de Referência , Retina/diagnóstico por imagem , Uveíte/etiologia , Uveíte/patologia , Estudos de Casos e Controles , Síndrome de Behçet/complicações , Estudos Prospectivos , Corioide/diagnóstico por imagem , Estatísticas não Paramétricas , Tomografia de Coerência Óptica/métodos , Pressão Intraocular , Fibras Nervosas/patologia
17.
Arq. bras. oftalmol ; 82(3): 183-188, May-June 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001301

RESUMO

ABSTRACT Purpose: To test the hypothesis that Chagas disease predisposes to optic nerve and retinal nerve fiber layer alterations. Methods: We conducted a cross-sectional study including 41 patients diagnosed with Chagas disease and 41 controls, paired by sex and age. The patients underwent ophthalmologic examinations, including intraocular pressure measurements, optic nerve and retinal nerve fiber layer screening with retinography, optical coherence tomography, and standard automated perimetry. Results: All of the patients with Chagas disease had a recent cardiologic study; 15 (36.6%) had heart failure, 14 (34.1%) had cardiac form without left ventricular dysfunction, and 12 (29.3%) had indeterminate form. Optic nerve/retinal nerve fiber layer alterations were observed in 24 patients (58.5%) in the Chagas disease group and 7 controls (17.1%) (p£0.01). Among these, optic nerve pallor, optic nerve alterations suggestive of glaucoma, notch, peripapillary hemorrhage, and localized retinal nerve fiber layer defect were detected. Alterations were more prominent in patients with Chagas disease and heart failure (11 patients), although they also occurred in those with Chagas disease without left ventricular dysfunction (7 patients) and those with indeterminate form (6 patients). Optical coherence tomography showed that themean of the average retinal nerve fiber layer thickness measured 89 ± 9.7 mm, and the mean of retinal nerve fiber layer superior and inferior thickness measured 109 ± 17.5 and 113 ± 16.8 mm, respectively were lower in patients with Chagas disease. In controls, these values were 94 ± 10.6 (p=0.02); 117 ± 18.1 (p=0.04), and 122 ± 18.4 mm (p=0.03). Conclusion: Changes in optic nerve/ retinal nerve fiber layer were more prevalent in patients with Chagas disease.


RESUMO Objetivo: Testar a hipótese de que a doença de Chagas predispõe a alterações no nervo óptico e camada de fibras nervosas peripapilar. Métodos: Foi realizado um estudo transversal com 41 pacientes diagnosticados com doença de Chagas e 41 controles, pareados por sexo e idade. Os pacientes foram submetidos a exames oftalmológicos, incluindo medida da pressão intraocular, avaliação do nervo óptico e camada de fibras nervosas através de retinografia, tomografia de coerência óptica e perimetria automatizada padrão. Resultados: Todos os pacientes com doença de Chagas apresentavam estudo cardiológico recente; 15 pacientes (36,6%) apresentavam insuficiência cardíaca; 14 (34,1%) forma cardíaca sem disfunção de ventrículo esquerdo e 12 (29,3%), forma indeterminada. Alterações do nervo óptico/camada de fibras nervosas foram observadas em 24 pacientes (58,5%) do grupo com doença de Chagas e 07 controles (17,1%) (p£0,01). Dentre estas, palidez do nervo óptico, alterações do nervo óptico sugestivas de glaucoma, entalhe, hemorragia peripapilar e defeito da camada de fibras localizado foram detectados. As alterações foram mais proeminentes nos pacientes com doença de Chagas e insuficiência cardíaca (11 pacientes) embora também ocorressem naqueles com doença de Chagas sem disfunção de ventrículo esquerdo (7 pacientes) e com forma indeterminada (6 pacientes). A tomografia de coerência óptica mostrou que a média da espessura da camada de fibras nervosas da retina mediu 89 ± 9,7 mm), e a média da espessura da camada de fibras nervosas superior e inferior mediu 109 ± 17,5 e 113 ± 16,8 mm, respectivamente, foi menor em pacientes com doença de Chagas. Nos controles, esses valores foram de 94 ± 10,6 mm (p=0,02); 117 ± 18,1 (p=0,04) e 122 ± 18,4 mm (p=0,03). Conclusão: Alterações do nervo óptico/camada de fibras nervosas da retina foram mais prevalentes nos pacientes com doença de Chagas.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Nervo Óptico/patologia , Retina/patologia , Doença de Chagas/patologia , Fibras Nervosas/patologia , Nervo Óptico/fisiopatologia , Nervo Óptico/diagnóstico por imagem , Valores de Referência , Retina/fisiopatologia , Doenças Retinianas/etiologia , Doenças Retinianas/patologia , Estudos de Casos e Controles , Doenças do Nervo Óptico/fisiopatologia , Doenças do Nervo Óptico/patologia , Estudos Transversais , Análise de Variância , Doença de Chagas/complicações , Doença de Chagas/fisiopatologia , Tomografia de Coerência Óptica , Testes de Campo Visual , Pressão Intraocular
18.
Rev. bras. oftalmol ; 77(6): 356-359, nov.-dez. 2018. graf
Artigo em Português | LILACS | ID: biblio-985303

RESUMO

Resumo Relato de caso de um paciente de 46 anos com glaucoma juvenil de controle clínico insatisfatório, portador de retinosquise peripapilar que, após ser submetido à esclerectomia profunda não penetrante, evoluiu com descolamento seroso da retina neuro-sensorial. A associação entre retinosquise peripapilar e o descolamento seroso pós cirurgia filtrante é de ocorrência rara, tendo sido descrito apenas um caso na literatura. A partir deste relato temos por objetivo, além de enfatizar a raridade da associação, mostrar a importância de investigar retinosquise peripapilar em pacientes glaucomatosos, em especial se associada a camada de fibras nervosas, e a importância da explanação adequada aos pacientes de um possível descolamento seroso de retina no pós-operatório de cirurgia filtrante.


Abstract Case report of a 46-year-old patient with unsatisfactory clinical controlled juvenile glaucoma and peripapillary retinoschisis who, after being submitted to non-penetrating deep sclerectomy, evolved with serous detachment of the neurosensory retina. The association between peripapillary retinoschisis and serous detachment after filtering surgery is rare and only one case has been described in the literature. The purpose of this report is, besides to emphasize the rarity of the association, to show the importance of investigating peripapillary retinoschisis in glaucomatous patients, especially if associated with retinal nerve fiber layer, and the importance of adequate explanation to patients of possible serous detachment of retina in the postoperative of filtering surgery.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Descolamento Retiniano/etiologia , Glaucoma/cirurgia , Cirurgia Filtrante/efeitos adversos , Retinosquise/complicações , Disco Óptico , Retina/diagnóstico por imagem , Esclera/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Descolamento Retiniano/diagnóstico , Cirurgia Filtrante/métodos , Tomografia de Coerência Óptica , Pressão Intraocular , Fibras Nervosas
19.
Rev. bras. oftalmol ; 77(6): 316-319, nov.-dez. 2018. tab
Artigo em Inglês | LILACS | ID: biblio-985302

RESUMO

Abstract Objective: To compare macular and peripapillary retinal nerve fiber layer thicknesses of dominant eye and non-dominant eye using optical coherence tomography (OCT). Methods: 104 eyes of 52 healthy young adults were included. Ophthalmological examinations; including measuring refraction, best corrected visual acuity, intraocular pressure (IOP) measurement, slit-lamb biomicroscopy, dilated fundus examination, measuring of central macular thickness (CMT), and peripapillary retinal nerve fiber layer (PRNFL) thickness were performed on each subject. Hole-in-the-card test was used to detect the ocular dominance. Results: There were 25 females (48%) and 27 males (52%) in the study. Eight participants had left eye dominance (15%), forty-four participants had right eye dominance (85%). Mean CMT was 192.5µm in dominant group and 191.9 µm in non-dominant group. There was no statistically significant difference between dominant eye group and non-dominant eye group in either macular thickness or peripapillary retinal nerve fiber layer thickness. Conclusions: No difference between macular and peripapillary retinal nerve fiber layer thicknesses were detected in dominant and non-dominant groups. Further evaluation is needed.


Resumo Objetivo: Comparar as espessuras da camada de fibras nervosas da retina macular e peripapilar do olho dominante e não dominante usando a tomografia de coerência óptica (OCT). Métodos: 104 olhos de 52 adultos jovens saudáveis foram incluídos. Exames oftalmológicos; incluindo medidas de refração, melhor acuidade visual corrigida, medição da pressão intraocular (PIO), biomicroscopia de fenda-cordeiro, exame do fundo dilatado, medição da espessura macular central (CMT) e espessura da camada de fibras nervosas da retina peripapilar (PRNFL) foram realizadas em cada sujeito. O teste Hole-in-the-card foi usado para detectar a dominância ocular. Resultados: houve 25 mulheres (48%) e 27 homens (52%) no estudo. Oito participantes tinham deixado a dominância do olho (15%), quarenta e quatro participantes tinham dominância do olho direito (85%). A CMT média foi de 192,5 µm no grupo dominante e 191,9 µm no grupo não dominante. Não houve diferença estatisticamente significativa entre o grupo dominante de olho e o grupo de olho não dominante tanto na espessura macular quanto na espessura da camada de fibras nervosas da retina peripapilar. Conclusões: Não houve diferença entre as espessuras das camadas de fibras nervosas da retina macular e peripapilar nos grupos dominante e não dominante. Mais avaliações são necessárias.


Assuntos
Humanos , Masculino , Feminino , Adulto , Retina/anatomia & histologia , Dominância Ocular/fisiologia , Macula Lutea/anatomia & histologia , Fibras Nervosas , Estudo Comparativo , Estudos Prospectivos , Tomografia de Coerência Óptica , Pressão Intraocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA