Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 141
Filtrar
1.
Artigo em Inglês | LILACS | ID: biblio-1444047

RESUMO

OBJECTIVE: To investigate the importance of improving visual assessment for community-dwelling older adult fallers. METHODS: Cross-sectional study with eligible older adults (> 60 years old) living in the community and who suffered at least one fall in the last 12 months from the PrevQuedas Brasil clinical trial. Sociodemographic data, information on previous falls, physical and functional assessment (BOMFAQ and FES-I) were collected. We evaluated impairments in visual acuity and contrast sensitivity using the Snellen E chart and low-contrast visual acuity tests, respectively. Dual visual impairment refers to the presence of both impairments. For statistical analysis we compared the participants in relation to the number of falls (single fallers or recurrent fallers) using Chi-square or Fisher's exact test and the significance level was <0.05 for all analyses. RESULTS: Visual acuity, low contrast sensitivity, and dual visual impairment were associated with recurrent falls (OR 1.85); visual impairment was more prevalent among the oldest old. Approximately 90% of the participants reported using glasses, and 63.80% used multifocal lenses. Dual impairment was identified in 143 (20.30%) participants. In multivariate logistic regression, the predictive variables for recurrent falls were low contrast sensitivity (95%CI 1.15­2.47), dual visual impairment (95%CI 1.16­2.83), and self-perceived fall risk (95%CI 1.16­2.46) which was measured using the Falls Efficacy Scale-International. CONCLUSION: Older adults with dual visual impairment are more likely to suffer recurrent falls. Low contrast sensitivity is crucial for fall risk assessment


OBJETIVO: Este estudo investiga a importância de avaliar a visão de idosos caidores na comunidade. METODOLOGIA: Estudo transversal com idosos elegíveis (> 60 anos) residentes na comunidade e que sofreram pelo menos uma queda nos últimos 12 meses do ensaio clínico PrevQuedas Brasil. Foram coletados dados sociodemográficos, informações sobre quedas pregressas, exames físicos e funcionais (BOMFAQ e FES-I). Avaliamos os comprometimentos da acuidade visual e da sensibilidade ao contraste por meio da Tabela E de Snellen e testes de acuidade visual de baixo contraste, respectivamente. O duplo déficit visual refere-se à presença de ambas as deficiências. Para análise estatística comparamos os idosos com relação ao número de quedas (caidores únicos ou caidores recorrentes) usando Qui-quadrado ou Teste exato de Fisher e o nível de significância foi <0.05 para todas as análises. RESULTADOS: Baixa acuidade visual, baixa sensibilidade ao contraste e duplo déficit visual foram associados a quedas recorrentes com odds ratio ­ OR 1,85, frequentemente mais prevalente entre os idosos longevos. Cerca de 90,00% dos idosos relataram usar óculos e 63,80% usavam lentes multifocais. O duplo déficit visual foi identificado em 143 (20,30%) participantes. Nos modelos de regressão logística multivariados, verificamos que as variáveis preditoras para queda recorrente foram a baixa sensibilidade ao contraste (intervalo de confiança ­ IC95% 1,15­2,47), duplo déficit (IC95% 1,16­2,83) e a autopercepção do risco de cair (IC95% 1,16­2,46) medido pela Falls Efficacy Scale-International. CONCLUSÃO: Idosos com baixa sensibilidade ao contraste e duplo déficit visual têm maiores chances de sofrerem múltiplas quedas quando comparados com idosos que possuem apenas baixa acuidade visual. Assim, a baixa sensibilidade ao contraste é essencial na avaliação do risco de quedas dos idosos


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Transtornos da Visão/epidemiologia , Acidentes por Quedas/estatística & dados numéricos , Sensibilidades de Contraste , Acuidade Visual , Estudos Transversais , Fatores de Risco , Fatores Sociodemográficos
2.
Rev. cuba. oftalmol ; 35(3)sept. 2022.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1441736

RESUMO

Objetivo: Determinar el cambio de la sensibilidad al contraste en pacientes operados de miopía con técnicas de superficie y su relación con la aberrometría ocular. Métodos: Se realizó un estudio experimental con 324 ojos de 162 pacientes miopes atendidos en la consulta de Cirugía Refractiva del Instituto Cubano de Oftalmología "Ramón Pando Ferrer" en el período de enero 2019 y marzo de 2020 y que fueron operados de cirugía refractiva con láser de excímero, técnicas de superficie y perfil de ablación asférico. La sensibilidad al contraste fue la variable principal de comparación entre ambas técnicas quirúrgicas. Se formaron dos grupos de pacientes, cuya asignación fue secuencial, al primer grupo, se le realizó la técnica quirúrgica PRK-MMC (81) y al segundo LASEK-MMC (81) con un seguimiento de 3 meses. Resultados: Predominaron las mujeres con miopía leve y edades entre 21 y 28 años. A los tres meses la sensibilidad al contraste, agudeza visual sin corrección, equivalente esférico y el valor cuadrático medio total mejoraron de manera significativa, mostrando una relación positiva con la sensibilidad al contraste en ambos grupos, sin diferencias entre ellos. Conclusiones: La sensibilidad al contraste mejora con técnicas de superficie y posee una relación positiva y significativa con los resultados visuales, refractivos y aberrométricos. El estudio de las aberraciones oculares proporciona un arma fundamental para valorar la calidad óptica del ojo humano, información que permite conocer la calidad visual que se puede esperar en los pacientes evaluados(AU)


Objective: To determine the change in contrast sensitivity in patients operated on for myopia with surface techniques and its relationship with ocular aberrometry. Methods: An experimental study was carried out with 324 eyes of 162 myopic patients treated at the Refractive Surgery Clinic of the Cuban Institute of Ophthalmology "Ramón Pando Ferrer" between January 2019 and March 2020 who underwent refractive surgery with excimer laser and surface techniques and aspheric ablation profile. Contrast sensitivity was the main variable of comparison between both surgical techniques. Two groups of patients were sequentially assigned, the first group underwent PRK-MMC (81) and the second LASEK-MMC (81) with a 3-month follow-up. Results: Women with mild myopia and ages between 21 and 28 years predominated. After 3 months contrast sensitivity, uncorrected visual acuity, spherical equivalent and total average square value improved significantly, showing a positive relationship with contrast sensitivity in both groups, with no differences between them. Conclusions: Contrast sensitivity improves with surface techniques and has a positive and significant relationship with visual, refractive and aberrometric outcomes. The study of ocular aberrations provides a fundamental tool to assess the optical quality of the human eye, information that allows us to know the vision quality that can be expected in the patients evaluated(AU)


Assuntos
Humanos , Feminino , Adulto , Sensibilidades de Contraste , Miopia/cirurgia
3.
Rev. bras. oftalmol ; 81: e0034, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1376787

RESUMO

ABSTRACT Objective: To measure visual acuity in high contrast and low contrast sensitivities in different grades of visible light transmission films in three different positions (front, lateral and rear windows). Methods: Forty-four healthy volunteers between 30-75 y-o, with BCVA better than 0,5, were tested in the 5 following vehicles with different grades of visible light transmission films. Vehicle 1: 75% in the front and 70% in the lateral and rear windows; Vehicle 2: 70% in the front and lateral windows and 28% in the rear; Vehicle 3: 70% in the front, 28% in the lateral and 15% rear; Vehicle 4: 35% in all 3 windows; Vehicle 5: 50% in the front, 20% in the lateral and 15% in the rear. Descriptive statistics were used and the average of the 3 measurements of VA was considered. Wilcoxon Test was applied to compare the average visual acuity in each vehicle and position. P value<0.05 was considered statistically significant. Results: According to the Brazilian Traffic Regulations for driving in categories C/D/E, when low contrast was tested in the front window, all visible light transmissions were borderline, in the lateral window they were all outside the limit, while in the rear window for both low and high contrast, all visible light transmissions tested were outside the limit and also borderline for driving in categories A/B, with the exception of the vehicle with visible light transmission of 35%. Conclusion: Visual acuity is affected, especially in the rear window, by the use of automotive films. The study is an alert that window films is a possible cause of accidents and may contribute to the revision of traffic regulations worldwide.


RESUMO Objetivo: Medir a acuidade visual em alto e baixo contraste nas diversas graduações de transparência de filmes em três janelas de veículos: frontal, lateral e traseira. Métodos: Foram avaliados 44 voluntários saudáveis entre 30 e 75 anos, com acuidade visual melhor corrigida acima de 0,5, em cinco veículos, sendo: veículo 1, com 75% de transparência frontal e 70% na lateral e traseira; veículo 2, com 70% na frontal e na lateral e 28% na traseira; veículo 3, com 70% na frontal, 28% na lateral e 15% na traseira; veículo 4, com 35% nas três janelas; e veículo 5, com 50% na frontal, 20% na lateral e 15% na traseira. Foi realizada estatística descritiva utilizando a média de três medidas consecutivas, com teste de Wilcoxon para comparar a média de acuidade visual em cada janela, e foi considerado estatisticamente significativo quando valor de p<0,05. Resultados: Todas as transparências testadas nos vidros reduziram a acuidade visual em situação de baixo contraste para níveis limítrofes na janela frontal e níveis ilegais na lateral para conduzir veículos nas categorias C/D/E. Na janela traseira, tanto em alto quanto em baixo contraste, todas as transparências mostraram redução da acuidade visual para níveis ilegais para categorias C/D/E e limítrofes para as categorias A/B, exceto na transparência de 35%. Conclusão: A acuidade visual é reduzida pelo uso dos filmes automotivos, especialmente na janela traseira. Condutores de veículos com filmes devem ser alertados pelo risco aumentado de acidentes. Esse dado científico propõe revisões nas regulações de tráfego mundiais.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Condução de Veículo/legislação & jurisprudência , Automóveis/legislação & jurisprudência , Automóveis/normas , Sensibilidades de Contraste , Acuidade Visual , Percepção Espacial , Testes Visuais , Iluminação , Acidentes de Trânsito , Estudos Transversais , Cor , Vidro , Luz
4.
Rev. cuba. oftalmol ; 34(3): e992, 2021. graf
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1352030

RESUMO

La sensibilidad al contraste es considerada como la capacidad de discriminar diferencias de iluminación entre áreas adyacentes, cuyo umbral se estima como la menor cantidad de contraste que se necesita para lograr esta distinción. La medida de la agudeza visual cuantifica la visión en alto contraste; sin embargo, los objetos que nos encontramos en la vida real no son solo de alto contraste, sino que presentan diferentes niveles de contraste y tamaño, lo cual puede ser determinado con el estudio de la sensibilidad al contraste, ya sea a través de cartillas de bajo contraste o de las pruebas que evalúan las frecuencias espaciales, que serán utilizadas según la edad del paciente pediátrico. Con este trabajo se pretende mostrar los diferentes criterios relacionados con la sensibilidad al contraste en edades pediátricas, para lo cual se realizó una búsqueda en diferentes publicaciones y textos de la especialidad. Existe controversia relacionada con la edad pediátrica en la cual se alcanza la sensibilidad al contraste al nivel del adulto, así como los valores normativos en la infancia con las diferentes pruebas empleadas. La valoración de la sensibilidad al contraste constituye una herramienta más para evaluar la función visual conjuntamente con la determinación de la agudeza visual y la visión de colores. Se necesitan más estudios sobre este tema para unificar criterios con el fin de perfeccionar la atención a la población pediátrica(AU)


Contrast sensitivity is the ability to distinguish differences in luminance between adjacent areas. Its threshold is estimated as the smallest amount of contrast needed to achieve such a distinction. Visual acuity measurement quantifies high contrast vision. However, the objects around us are not only characterized by high contrast: they display different levels of contrast and size, which may be determined through the study of contrast sensitivity, either with low contrast charts or spatial frequency tests, to be used according to the pediatric patient's age. The purpose of the study was to present various criteria about contrast sensitivity in pediatric ages. To achieve this end, a search was conducted in different publications and texts from the specialty. A debate is currently in progress about the pediatric age in which adult contrast sensitivity is achieved and the standard values to be verified with the different tests applied in childhood. Contrast sensitivity assessment is one more tool to evaluate visual function and determine visual acuity and color vision. Further studies are required about the subject aimed at unifying criteria so as to improve the care of the pediatric population(AU)


Assuntos
Humanos , Pré-Escolar , Criança , Visão Ocular , Sensibilidades de Contraste , Acuidade Visual , Literatura de Revisão como Assunto
5.
Rev. cuba. oftalmol ; 33(3): e734, tab
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1139089

RESUMO

RESUMEN Objetivo: Comparar la sensibilidad al contraste evaluada en un grupo de mexicanos con diabetes mellitus contra uno sin diabetes como control. Métodos: Un total de 31 voluntarios, 14 participantes con DM con un tiempo de diagnóstico entre 2 y 20 años (sin retinopatía diabética), y 17 en el grupo control iniciaron el estudio; 4 diabéticos y 5 no diabéticos fueron excluidos por no cumplir con los criterios de inclusión. Por lo tanto, los datos analizados fueron de un grupo de 10 diabéticos (52 ± 10 años) y otro de 12 no diabéticos (52 ± 6 años). Se evaluó la sensibilidad al contraste con la cartilla Vector Vision CSV1000E a una distancia de 2,5 metros con una iluminación de 85 cd/m2. Resultados: Un mayor porcentaje de ojos diabéticos alcanzaron un mejor umbral de contraste en 3, 6 y 18 ciclos por grado en comparación con el grupo control. En 12 ciclos por grado solamente en los umbrales 1 y 5. Conclusiones: La sensibilidad al contraste de la población mexicana con diabetes mellitus presenta mejor percepción de contraste en las frecuencias evaluadas que el grupo control(AU)


ABSTRACT Objective: Compare contrast sensitivity as measured in a group of Mexican diabetes mellitus patients versus a control non-diabetic group. Methods: A group of 31 volunteers, 14 participants with DM with a diagnosis time between 2 and 20 years (without diabetic retinopathy), and 17 in the control group started the study; 4 diabetics and 5 non-diabetics were excluded because they did not meet the inclusion criteria. Therefore, the data analyzed were from a group of 10 diabetics (52 ± 10 years) and another of 12 non-diabetics (52 ± 6 years). Contrast sensitivity was evaluated with a Vector Vision CSV1000E chart at a distance of 2.5 meters and a luminance of 85 cd/m2. Results: A higher percentage of diabetic eyes reached a better contrast threshold at 3, 6 and 18 cycles per degree in comparison with the control group. At 12 cycles per degree only at thresholds 1 and 5. Conclusions: Contrast sensitivity in the Mexican population with diabetes mellitus displays better contrast perception at the frequencies evaluated than the control group(AU)


Assuntos
Humanos , Visão Ocular , Sensibilidades de Contraste , Diabetes Mellitus/epidemiologia , Retinopatia Diabética/etiologia
6.
Braz. J. Psychiatry (São Paulo, 1999, Impr.) ; 42(1): 27-32, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1055350

RESUMO

Objective: Patients with schizophrenia have visual processing impairments. The main findings from the literature indicate that these deficits may be related to differences in paradigms, medications, and illness duration. This study is part of a large-scale study investigating visual sensitivity in schizophrenia. Here we aimed to investigate the combined effects of illness duration and antipsychotic use on contrast sensitivity function. Methods: Data were collected from 50 healthy controls and 50 outpatients with schizophrenia (classified according to illness duration and medication type) aged 20-45 years old. The contrast sensitivity function was measured for spatial frequencies ranging from 0.2 to 20 cycles per degree using linear sine-wave gratings. Results: Patients with an illness duration > 5 years had more pronounced deficits. Differences in the combined effects of illness duration and antipsychotic use were marked in patients on typical antipsychotics who had been ill > 10 years. No significant differences were found between typical and atypical antipsychotics in patients with an illness duration < 5 years. Conclusion: Visual impairment was related to both long illness duration and medication type. These results should be tested in further studies to investigate pharmacological mechanisms.


Assuntos
Humanos , Masculino , Feminino , Adulto , Adulto Jovem , Esquizofrenia/tratamento farmacológico , Antipsicóticos/efeitos adversos , Transtornos da Visão/induzido quimicamente , Escalas de Graduação Psiquiátrica , Esquizofrenia/complicações , Fatores de Tempo , Visão Ocular/efeitos dos fármacos , Sensibilidades de Contraste/efeitos dos fármacos , Estudos de Casos e Controles , Clorpromazina/efeitos adversos , Resultado do Tratamento , Pessoa de Meia-Idade
7.
Psicol. reflex. crit ; 33: 14, 2020. tab, graf
Artigo em Inglês | LILACS, Index Psicologia - Periódicos | ID: biblio-1135897

RESUMO

Abstract The aim of this study was to analyze the contrast sensitivity of spatial luminance and the color discrimination thresholds of the protan, deutan, and tritan axes of people with leprosy. This study included 8 subjects with leprosy (M = 4, W = 4, M = 33.38 ± 8.7) and 8 healthy subjects (M = 4, W = 4, M = 30.89 ± 5.8). The contrast sensitivity was evaluated by the Metropsis software version 11.0 with vertical sinusoidal grids of frequencies of 0.2, 0.5, 1, 5, 10, and 16 cycles per degree of visual angle (cpd) and color vision by the desaturated Lanthony D15 tests and the trivector and ellipse protocols of the Cambridge Color Test. The results showed significant differences between the groups in the processing of spatial frequencies of 0.2 (U = 14; p = .018); 5.0 (U = 45.0; p = .001); 10.0 (U = 45.0; p = .001), and 16.0 (U = 45.0; p = .001) cpd. The difference in color recognition through D15d (U = 4.0; p = .002). Ellipse 2 (U = 10.0; p = .012) and ellipse 3 (U = 9.0; p = .009) were discriminated against. Overall, the results indicate that leprosy changes the visual processing of low, medium, and high spatial frequencies, as well as the sensitivity of the short wavelength (tritan line of confusion) and long (protan line of confusion) cones.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Transtornos da Visão/epidemiologia , Sensibilidades de Contraste , Percepção de Cores , Hanseníase/complicações
8.
Psico (Porto Alegre) ; 51(4): 38077, 2020.
Artigo em Português | LILACS | ID: biblio-1178129

RESUMO

A medida de Sensibilidade ao Contraste (SC) de primeira ordem é frequentemente utilizada para avaliação da percepção espacial. Nosso objetivo foi desenvolver e validar um teste de SC de segunda ordem para aplicação clínica. Modificações metodológicas foram realizadas na rotina psicofísica para redução do tempo de testagem em um primeiro experimento, validamos a nova metodologia. Em um segundo experimento, valores de normalidade foram derivados do resultado de 16 participantes e foram testados nas mesmas condições do primeiro experimento. As medidas de validade foram obtidas por meio do Spearman-Brown Split-Half Reliability Coefficient para todas as frequências espaciais testadas (r> 0,90). O desenvolvimento e a validação deste novo experimento para as medidas de SC de segunda ordem permitirão avançar nos estudos dos mecanismos básicos da percepção de espaço para estímulos complexos, assim como a aplicação clínica em diversas doenças.


The first-order Contrast Sensitivity (SC) measure is often used to assess spatial perception. Our goal was to develop and validate a second-order SC test for clinical application. Methodological changes were made in the psychophysical routine to reduce testing time and in the first experiment we validated the new methodology. In a second experiment, normal values were derived from the result of sixteen participants who were tested under the same conditions as the first experiment. Validity measures were obtained using Spearman-Brown Split-Half Reliability Coefficient for all tested spatial frequencies (r> 0.90). The development and validation of this new experiment for second-order SC measures will allow to advance in the studies of the basic mechanisms of the perception of space for complex stimuli, as well as the clinical application in several diseases.


La medida de sensibilidad al contraste (SC) de primer orden se utiliza a menudo para evaluar la percepción espacial. Nuestro objetivo era desarrollar y validar una prueba SC de segundo orden para aplicación clínica. Se realizaron cambios metodológicos en la rutina psicofísica para reducir el tiempo de prueba y en el primer experimento validamos la nueva metodología. En un segundo experimento, los valores normales se derivaron del resultado de dieciséis participantes que fueron evaluados en las mismas condiciones que el primer experimento. Las medidas de validez se obtuvieron utilizando el coeficiente de confiabilidad de la mitad dividida de Spear-man-Brown para todas las frecuencias espaciales probadas (r> 0.90). El desarrollo y validación de este nuevo experimento para medidas CS de segundo orden permitirá avanzar en los estudios de los mecanismos básicos de percepción del espacio para estímulos complejos, así como la aplicación clínica en diversas enfermedades.


Assuntos
Humanos , Masculino , Feminino , Psicofísica , Percepção Espacial , Sensibilidades de Contraste
9.
Rev. bras. oftalmol ; 77(5): 292-295, set.-out. 2018. tab, graf
Artigo em Português | LILACS | ID: biblio-977862

RESUMO

Resumo A toxoplasmose ocular congênita é uma manifestação da infecção pelo parasita Toxoplasma gondii que ocorrer por meio placentário. Essa doença pode provocar importantes sequelas visuais. Este trabalho descreve um estudo de caso que utilizou avaliação psicofísica visual para descrever alterações funcionais decorrentes da toxoplasmose ocular congênita. A avaliação foi realizada em paciente de 30 anos, sexo masculino, residente em São Luís (MA), hígido com histórico da mãe ter apresentado infecção por toxoplasmose no período gestacional. Somente aos 26 anos foi feita uma avaliação médica detalhada que descreveu lesão na fóvea do olho direito. Na avaliação clínica clássica e na avaliação psicofísica visual, o paciente apresentou visão normal para o olho esquerdo. O olho direito apresentou baixa acuidade visual (valor decimal: 0,028), campo visual com escotomas localizados até 20º de ângulo visual e alteração da visão de cor. O estudo fornece informações médicas seguras e relevantes para o diagnóstico de toxoplasmose ocular congênita utilizando testes eficazes, de baixo custo e boa portabilidade, possibilitando uma alternativa de diagnóstico funcional para ser aplicada em locais de difícil acesso pelo interior do Brasil.


Abstract Congenital ocular toxoplasmosis is a manifestation of infection by the parasite Toxoplasma gondii that occurs through the placenta. This disease can lead to important visual sequelae. This paper describes a case report that uses visual psychophysics for the alterations of congenital ocular toxoplasmosis. The evaluation was performed in a 30-year-old man, a resident of São Luís (MA), with a history of his mother have had toxoplasmosis in the gestational period. Only at 26 years-old he did the detailed medical evaluation that described a lesion the fovea of the right eye. In the classic clinical examination and in visual psychophysical evaluation, the patient presented normal vision for the left eye. The right eye had low visual acuity (decimal value: 0.028), visual field with scotomas up to 20º of visual angle and alteration of color vision. The study offers safe and relevant medical information for the diagnosis of congenital ocular toxoplasmosis using a low-cost evaluation and with good portability, allowing a functional diagnostic alternative to be applied in places difficult to access in the interior of Brazil.


Assuntos
Humanos , Masculino , Adulto , Psicofísica/métodos , Acuidade Visual , Toxoplasmose Ocular/congênito , Toxoplasmose Ocular/diagnóstico , Toxoplasma , Sensibilidades de Contraste/fisiologia , Campos Visuais/fisiologia , Toxoplasmose/transmissão , Complicações Parasitárias na Gravidez , Percepção de Cores/fisiologia , Testes de Percepção de Cores/métodos , Transmissão Vertical de Doenças Infecciosas , Testes de Campo Visual/métodos
10.
Braz. j. med. biol. res ; 51(3): e6568, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889051

RESUMO

The goal of this study was to compare the visual contrast sensitivity (CS) of men and women exposed and not exposed to organic solvents. Forty-six volunteers of both genders aged between 18 and 41 years (mean±SD=27.72±6.28) participated. Gas station attendants were exposed to gas containing 46.30 ppm of solvents at a temperature of 304±274.39 K, humidity of 62.25±7.59% and ventilation of 0.69±0.46 m/s (a passive gas chromatography-based sampling method was used considering the microclimate variables). Visual CS was measured via the psychophysical method of two-alternative forced choice using vertical sinusoidal gratings with spatial frequencies of 0.2, 0.5, 1.0, 2.0, 5.0, 10.0, and 16.0 cpd (cycles per degree) and an average luminance of 34.4 cd/m2. The results showed that visual CS was significantly lower (P<0.05) in the following groups: i) exposed men compared to unexposed men at frequencies of 0.2, 0.5, 1.0, and 2.0 cpd; ii) exposed women compared to unexposed women at a frequency of 5.0 cpd; and iii) exposed women compared to exposed men at a frequency of 0.5 cpd, even at exposures below the tolerance limit (300 ppm). These results suggest that the visual CS of exposed men was impaired over a wider range of spatial frequencies than that of exposed women. This difference may have been due to the higher body fat content of women compared to that of men, suggesting that body fat in women can serve as a protective factor against neurotoxic effects.


Assuntos
Humanos , Masculino , Feminino , Adulto , Adulto Jovem , Sensibilidades de Contraste/efeitos dos fármacos , Exposição Ocupacional/efeitos adversos , Solventes/efeitos adversos , Percepção Visual/fisiologia , Tecido Adiposo/anatomia & histologia , Brasil/epidemiologia , Escolaridade , Microclima , Exposição Ocupacional/estatística & dados numéricos , Limiar Sensorial/fisiologia , Fatores Sexuais , Aprendizagem Espacial/fisiologia
11.
Rev. bras. oftalmol ; 76(2): 61-64, Mar.-Apr. 2017. tab, graf
Artigo em Português | LILACS | ID: biblio-899042

RESUMO

Resumo Objetivo: Correlacionar o coeficiente de asfericidade com a aberração esférica longitudinal na superfície corneana, correlacionando também cada uma dessas variáveis com a ceratometria média Métodos: Realizou-se um estudo observacional através da coleta de dados pré-operatórios nos prontuários de indivíduos candidatos a facectomia. Os dados coletados se referiam ao sexo e idade, além do Q, LSA da superfície corneana e ceratometria média (Km). Foram excluídos do estudo os pacientes que realizaram qualquer procedimento cirúrgico corneano, por alterar as medidas da Q, LSA e Km. O topógrafo selecionou, de maneira fixa, uma área 4,5mm da superfície anterior da córnea para medida do Q e da LSA, tendo como ponto central o eixo pupilar. A ocorrência da LSA é relevante em ambientes de penumbra, em indivíduos com pupila maior que 3mm. Resultados: A amostra foi composta por 70 olhos de 35 indivíduos: 24 (68,6%) mulheres e 11 (31,4%) homens. A idade variou de 48 a 89 anos (média de 69,97 ± 8,29). A Km variou de 41,00D a 46,50D com média de 43,94 ± 1,48D. Na avaliação do Q da superfície corneana se observou uma média de -0,15 ± 0,15. Seis (8,57%) córneas apresentaram desenho esférico com Q= 0 e apenas uma córnea apresentou desenho asférico com Q= -0,50, gerando LSA= 0,0µm. Em relação a LSA da superfície corneana se observou média de +0,33 ± 0,14 µm. Quarenta e dois olhos (60,0%) apresentaram LSA entre +0,31 a +0,64µm e 19 (27,15%) entre +0,16 a +0,30µm. Não houve correção entre a Km e o Q (r= -0,005 / p= 0,965), assim como entre Km e a LSA (r= 0,167 / p= 0,170). Observou-se correlação (r= 0,962 / p= 0,000) entre as variáveis Q x LSA. Conclusão: Foi observada correlação entre o Q e a LSA da superfície corneana. Não foi observado correlações entre o coeficiente de asfericidade ou aberração esférica longitudinal com a ceratometria média.


Abstract Objective: To correlate the asphericity coefficient (Q) with longitudinal spherical aberration (LSA) of the corneal surface, also correlating each of these variables with the average keratometry Methods: An observational study was conducted by collecting preoperative data from the medical records of individuals candidate cataract surgery, i.e., patient sex and age, as well as Q, LSA of the corneal surface and mean keratometry (Km). Patients who had been subjected to any corneal surgical procedure who would alter Q, LSA and Km measuements were excluded. The corneanl topograph selected, fixedly, a 4.5 mm area of the anterior surface of the cornea for the measurement of Q and LSA, having the pupillary axis as the central point, since the occurrence of LSA is relevant in dim environments in individuals with a pupil wider than 3 mm Results: The sample consisted of 70 eyes of 35 individuals, 24 of them women (68.6%) and 11 men (31.4%) ranging in age from 48 to 89 years (mean: 69.97 ± 8.29). Km ranged from 41.00 to 46.50 D, with a mean of 43.94 ± 1.48D, and mean Q of the corneal surface was -0.15 ± 0.15. Six corneas showed a spherical design (Q= 0.0) and only one showed an aspheric design with Q = -0.50, generating an LSA of 0.0. Mean LSA of the corneal surface was +0.33 ± 0.14 µm. Only one eye showed an LSA equal to 0.0µm, and five showed an LSA of +0.10 to +0.30µm. No eye showed a negative LSA of the corneal surface. There was no correlation between Km and Q (r = -0.005 / p = 0.965) or between Km and LSA (r = 0.167 / p = 0.170). A correlation (r = 0.962 / p = 0.000) was observed between Q and LSA Conclusion: There was a correlation between Q and LSA of the corneal surface. There was no correlation between the sphericity coefficient or longitudinal spherical aberration with the average keratometry.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Córnea/anatomia & histologia , Topografia da Córnea/métodos , Tamanho do Órgão , Sensibilidades de Contraste , Pupila , Registros Médicos , Córnea/fisiologia , Implante de Lente Intraocular , Estudo Observacional , Matemática , Fenômenos Fisiológicos Oculares
12.
Arq. bras. oftalmol ; 79(5): 323-327, Sept.-Oct. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-827969

RESUMO

ABSTRACT Purpose: To analyze the intrasession and intersession repeatability of contrast sensitivity (CS) measurements in patients with glaucoma, cataract, or age-related macular degeneration (AMD) and healthy controls. Methods: CS measurements were performed using the OPTEC-Functional Vision Analyzer (FVA), which uses a standardized and closed (view-in) system. Measurements for patients with glaucoma, cataract, or AMD and healthy controls were repeated within 30 minutes (intrasession) and during two sessions (intersession), separated by one week to one month. Test-retest reliability and correlation were measured using the intraclass correlation coefficient (ICC) and coefficient of repeatability (COR). Results: Ninety subjects (90 eyes) with visual acuity of 0.17 logMAR or higher in the cataract group or 0.00 logMAR in the other groups were included. During the first session, the ICC values were 0.87, 0.90, 0.76, and 0.69, and COR values were 0.24, 0.20, 0.38, and 0.25 for the control, glaucoma, cataract, and AMD groups, respectively. The reliability scores significantly improved during the second session, except in the glaucoma group. There was an acceptable floor effect and no ceiling effect at higher frequencies in the glaucoma and AMD groups. Conclusion: In subjects with good visual acuity, the FVA system is useful for evaluating CS and demonstrates good repeatability, as shown by ICC and COR. Because there is no ceiling effect, this system is beneficial for evaluation of early changes in CS, particularly in patients with glaucoma or AMD.


RESUMO Objetivo: Analisar a reprodutibilidade intrassessão e intersessão das medidas de sensibilidade ao contraste (CS) em pacientes com degeneração macular relacionada à idade (AMD), glaucoma e catarata. Método: As medidas de CS foram feitas pelo OPTEC-Funcional Visão Analyzer (FVA), que utiliza um sistema padronizado e fechado de avaliação da acuidade visual. Medidas em pacientes com AMD, glaucoma, catarata e nos controles saudáveis foram repetidas no prazo de 30 minutos (intrassessão) em duas visitas (intersessão), separadas por uma semana a um mês. A confiabilidade e correlação teste-reteste foram calculados por meio do coeficiente de correlação intraclasse (ICC) e coeficiente de reprodutibilidade (COR). Resultados: Noventa olhos de 90 indivíduos foram recrutados com acuidade visual de 0,17 logMAR ou melhor em catarata e 0,00 logMAR nos outros grupos. A confiabilidade da CS na primeira visita dos grupos normal, glaucoma, catarata e AMD foram, respectivamente, ICC 0,87; 0,90; 0,76; 0,69, e COR 0,24; 0,20; 0,38; 0,25. Os índices de confiabilidade foram significativamente melhorados nas segundas visitas, exceto no grupo glaucoma. Houve um efeito chão aceitável e nenhum efeito teto em frequências mais altas nos grupos glaucoma e AMD. Conclusões: Em indivíduos com boa acuidade visual, o sistema FVA de avaliação da CS é útil e apresenta boa confiabilidade, como mostrado pelas análises de ICC e COR. Por não apresentar efeito teto, este sistema parece ser benéfico para a avaliação das alterações precoces de CS, especialmente no glaucoma e AMD.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Catarata/fisiopatologia , Sensibilidades de Contraste/fisiologia , Glaucoma/fisiopatologia , Degeneração Macular/fisiopatologia , Valores de Referência , Fatores de Tempo , Testes Visuais/instrumentação , Testes Visuais/métodos , Catarata/diagnóstico , Estudos de Casos e Controles , Glaucoma/diagnóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores Etários , Estatísticas não Paramétricas , Degeneração Macular/diagnóstico
13.
Arq. bras. oftalmol ; 79(2): 73-77, Mar.-Apr. 2016. tab
Artigo em Inglês | LILACS | ID: lil-782797

RESUMO

ABSTRACT Purpose: To compare visual acuity (VA), contrast sensitivity, stereopsis, and subjective visual performance of Acuvue® Oasys® for Presbyopia (AOP), Air Optix® Aqua Multifocal (AOMF), and Air Optix® Aqua Single Vision (AOSV) lenses in patients with presbyopia. Methods: A single-blinded crossover trial was conducted. Twenty patients with mild presbyopia (add ≤+1.25 D) and 22 with moderate/severe presbyopia (add ≥+1.50 D) who wore lenses bilaterally for 1 h, with a minimum overnight washout period between the use of each lens. Measurements included high- and low-contrast visual acuity (HCVA and LCVA, respectively) at a distance, contrast sensitivity (CS) at a distance, HCVA at intermediate (70 cm) and near (50 cm & 40 cm) distances, stereopsis, and subjective questionnaires regarding vision clarity, ghosting, overall vision satisfaction, and comfort. The test variables were compared among the lens types using repeated-measures ANOVA. Results: Distance variables (HCVA, LCVA, and CS) were significantly worse with multifocal lens than with AOSV lens (p≤0.008), except for AOMF lens in the mild presbyopia group in which no significant difference was observed (p>0.05). Multifocal lenses had significantly greater HCVA at 40 cm than AOSV lens (p≤0.026). AOMF lens had greater intermediate HCVA than AOP lens (p<0.03). AOP lens demonstrated greater improvements in stereopsis than AOMF and AOSV lens in the moderate/severe presbyopia group (p≤0.03). Few significant differences in subjective variables were observed, with no significant difference in the overall vision satisfaction observed between lens types (p>0.05). The proportions of patients willing to buy AOSV, AOMF, and AOP lenses were 20%, 40%, and 50%, respectively, in the mild presbyopia group and 14%, 32%, and 23%, respectively, in the moderate/severe presbyopia group; however, these differences were not statistically significant (p≥0.159). Conclusions: Further development of multifocal lenses is required before significant advantages of multifocal lenses over single vision lens are observed in patients with presbyopia.


RESUMO Objetivo: Comparar a acuidade visual, sensibilidade ao contraste, estereopsia e desempenho visual subjetivo de présbitas usando lentes de contato Acuvue Oasys para presbiopia (AOP), Air Optix Aqua Multifocal (AOMF) e Air Optix Aqua Single Vision (AOSV). Método: Foi realizado estudo mascarado simples, cruzado. Vinte pacientes com presbiopia baixa (adição ≤+1,25 D) e 22 com presbiopia média/alta (adição ≥+1,50 D) usaram cada lente bilateralmente durante 1 hora, com descanso mínimo de uma noite entre as diferentes lentes. As medições incluíram acuidade visual para distância em alto e baixo contraste (HCVA, LCVA), sensibilidade ao contraste para distância (CS), HCVA para distância intermediária (70 cm) e para perto (50 cm e 40 cm), estereopsia e questionários subjetivos sobre nitidez visual, fantasmas, satisfação visão geral e conforto. As variáveis foram comparadas entre os tipos de lentes, utilizando medidas repetidas ANOVA. Resultados: As variáveis para distância (HCVA, LCVA, CS) foram significativamente piores com as multifocais em relação a AOSV (p≤0,008), exceto para AOMF no grupo de baixa adição, que não foi significativamente diferente (p>0,05). As multifocais foram significativamente melhores do que a AOSV para HCVA em 40 cm (p≤0,026). AOMF superou AOP para HCVA intermediária (p<0,03). AOP superou AOMF e AOSV em relação à estereopsia no grupo de presbiopia médio/alto (p≤0,03). Houve poucas diferenças significativas nas variáveis subjetivas, mas a satisfação visual global não foi significativamente diferente entre as lentes (p>0,05). A disposição para comprar lentes AOSV, AOMF e AOP foi: 20%, 40%, 50%, respectivamente, no grupo de presbiopia baixa; 14%, 32%, 23% no grupo de presbiopia média/alto, mas essas diferenças não foram estatisticamente significativas (p≥0,159). Conclusões: Melhorias futuras parecem ser necessárias para produção de uma lente multifocal que forneça aos présbitas uma vantagem significativa sobre a lente de visão única.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Presbiopia/reabilitação , Lentes de Contato Hidrofílicas , Desenho de Equipamento , Presbiopia/classificação , Testes Visuais , Sensibilidades de Contraste/fisiologia , Acuidade Visual/fisiologia , Método Simples-Cego , Estudos Prospectivos , Inquéritos e Questionários , Satisfação do Paciente , Estudos Cross-Over , Percepção de Profundidade/fisiologia
14.
Psicol. reflex. crit ; 29: 14, 2016. tab, graf
Artigo em Inglês | Index Psicologia - Periódicos, LILACS | ID: lil-785105

RESUMO

The aim of this study was to measure visual contrast sensitivity (CS) of luminance using vertical sinusoidal gratings with spatial frequencies of 0.6, 2.5, 5.0 and 20.0 cycles per degree of visual angle in chronic alcoholics in abstinence period. The participants were 20 volunteers ((26­59 years of age) divided into two groups: the study group (SG) consisted of 10 volunteers with a clinical history of chronic alcoholism abstinence and the control group (CG) consisted of 10 healthy volunteers. Each group had five female and five male participants. All participants had normal or corrected visual acuity and were free of identifiable diseases. The psychophysical method of forced choice between two temporal alternatives (2AFC) was used to measure visual CS of luminance of 41.2 cd/m2. The results showed significant differences between groups for all spatial frequencies tested (p< 0.001). These results suggest alterations in the visual perception related to chronic alcohol consumption even after years of abstinence. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Alcoolismo , Sensibilidades de Contraste , Percepção Visual , Abstinência de Álcool/psicologia
15.
Rev. cuba. inform. méd ; 7(2)July.-Dec. 2015.
Artigo em Espanhol | LILACS, CUMED | ID: lil-769429

RESUMO

Las pruebas clínicas para evaluar la supresión están diseñadas generalmente para comprobar solamente su presencia. En este trabajo se evalúa la fiabilidad de la cuantificación de la supresión basada en contraste. Se utilizó una tarea dicóptica de discriminación de movimiento global con kinematogramas de puntos aleatorios, una técnica de codificación cromática basada en la división del espectro visible, para la construcción de la presentación dicóptica, y la variante de cuantificación que comprende una etapa binocular y otra dicóptica. Para determinar el desempeño se utilizó el método de la escalera. A pesar de las limitaciones del experimento, los resultados apoyan la teoría sobre la relevancia del desequilibrio de contraste intraocular en el proceso de la supresión, corroboran la fiabilidad de la cuantificación de la supresión basada en contraste y validan la viabilidad de la técnica cromática dicóptica(AU)


Clinic trials to evaluate suppression are generally designed to check only their presence. In this work the reliability of quantifying suppression based on contrast is evaluated. Dichoptic task for discrimination of global motion was used with a random dot kinematograms. A chromatic technique based on division of visible spectra, was used for development of dichoptic presentation, and the quantification variant comprising binocular and dichoptic stages was selected. To determinate the performance the staircase method was used. Despite the limitations of experiment, the results support the theory on the relevance of intraocular contrast imbalance in the suppression process; they confirm the reliability of quantifying suppression based on contrast and validate the feasibility of dichoptic chromatic technique(AU)


Assuntos
Humanos , Masculino , Feminino , Sensibilidades de Contraste , Técnicas de Diagnóstico Oftalmológico , Visão de Cores
16.
Arq. bras. oftalmol ; 78(5): 273-277, Sep.-Oct. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-761522

RESUMO

ABSTRACTPurpose:To evaluate the visual function and architecture of the central and peripapillary retina in patients with inactive toxoplasmic retinochoroiditis outside the macular and peripapillary regions (zones 2 and 3).Methods:Cross-sectional study of 20 eyes (18 patients) with zone 2 and 3 toxoplasmic scars and visual acuity ≥20/25. Patients underwent Humphrey 10-2 perimetry, contrast sensitivity (Mars test), and color vision testing (L'Anthony desaturated D-15). The retinal nerve fiber layer (RNFL) and macular thicknesses were determined by optical coherence tomography.Results:The patients' mean age was 27.4 ± 10.3 years, and the mean duration of remission was 6.15 ± 5.19 months. Abnormal contrast sensitivity and color vision were observed in three (15.0%) and four eyes (20.0%), respectively. Mean deviation (MD) and pattern standard deviation (PSD) fell outside the 95% normal confidence limits of the perimeter's database in 14 (70.0%) and seven eyes (35.0%), respectively. Foveal and mean RNFL thicknesses were within the normal limits in all eyes. Eyes with zone 2 retinochoroiditis had lower foveal sensitivity than eyes with zone 3 lesions (p=0.041). Eyes with a longer duration of remission had a higher MD (r=0.575; p=0.013) and a lower PSD (r=-0.593; p=0.010).Conclusions:Despite normal central and peripapillary retinal architecture, eyes with inactive zone 2 and 3 toxoplasmic retinochoroiditis can present with abnormal color, contrast, and macular perimetric sensitivity. Zone 2 retinochoroiditis was associated with lower foveal sensitivity, and a longer duration of retinochoroiditis remission was associated with better perimetric parameters (MD and PSD).


RESUMOObjetivo:Avaliar a função visual e arquitetura da retina central e peripapilar em pacientes com retinocoroidite toxoplásmica inativa fora da região macular e peripapilar (zonas 2 e 3).Métodos:Estudo transversal de 20 olhos (18 pacientes) com cicatrizes toxoplásmicas nas zonas 2 e 3 com acuidade visual ≥20/25. Os pacientes foram submetidos à perimetria Humphrey 10-2, teste de sensibilidade ao contraste (Teste Mars) e teste de visão de cores (L'Anthony D-15 dessaturado). As espessuras da camada de fibras nervosas da retina (CFNR) e da mácula foram determinadas pela tomografia de coerência óptica.Resultados:A média de idade dos pacientes foi 27,4 ± 10,3 anos, e a duração média da remissão da retinocoroidite foi de 6,15 ± 5,19 meses. Alterações na sensibilidade ao contraste e cores foram observada em, respectivamente, 3 olhos (15,0%) e 4 olhos (20,0%). Os índices perimétricos mean deviation (MD) e pattern standard deviation (PSD) estiveram fora do intervalo de confiança de 95% do perímetro em 14 olhos (70,0%) e 7 olhos (35,0%), respectivamente. A espessura foveal e da CFNR média estiveram dentro do limite da normalidade em todos os olhos. Olhos com retinocoroidite na zona 2 tiveram menor sensibilidade foveal que olhos com lesões na zona 3 (p=0,041). Olhos com remissão de longa duração tiveram um MD mais alto (r=0,575; p=0,013) e um PSD mais baixo (r=-0,593; p=0,010).Conclusão:Apesar da arquitetura normal da retina central e peripapilar, olhos com retinocoroidite inativa nas zonas 2 e 3 podem apresentar anormalidades da visão de cores, sensibilidade ao contras e perimetria macular. A retinocoroidite na zona 2 está associada a uma menor sensibilidade foveal. Longos intervalos de remissão da retinocoroidite estiveram associados a melhores parâmetros perimétricos (MD e PSD).


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Coriorretinite/fisiopatologia , Macula Lutea/fisiopatologia , Toxoplasmose Ocular/fisiopatologia , Visão Ocular/fisiologia , Estudos Transversais , Coriorretinite/patologia , Sensibilidades de Contraste/fisiologia , Macula Lutea/patologia , Nervo Óptico/patologia , Nervo Óptico/fisiopatologia , Valores de Referência , Estatísticas não Paramétricas , Tomografia de Coerência Óptica , Toxoplasmose Ocular/patologia , Testes de Campo Visual , Campos Visuais/fisiologia
17.
Psicol. reflex. crit ; 28(3): 522-531, Jul-Sep/2015. tab, graf
Artigo em Português | LILACS, Index Psicologia - Periódicos | ID: lil-752004

RESUMO

Este estudo teve como objetivo avaliar a curva de sensibilidade ao contraste para estímulos de grades senoidais verticais de frequências espaciais de 0,2; 0,6; 1; 3,1; 6,1; 8,8; 13,2 e 15,6 ciclos por grau de ângulo visual; em um ritmo de 24 horas de adultos saudáveis de diferentes cronotipos. Participaram desta pesquisa 18 voluntários do sexo masculino com idade de 19 a 31 anos (M=23,8; DP=3,29). Os participantes foram divididos em grupos de acordo com o cronotipo: Matutino (n=5), Intermediário (n=9) e Moderadamente vespertino (n=4). Utilizaram-se como instrumentos medidas neuropsicológicas e o software Metropsis para avaliar a Função de Sensibilidade ao Contraste (FSC). As medidas da FSC foram realizadas com o método psicofísico da escolha forçada entre duas alternativas espaciais. Os resultados apresentaram alterações nas dimensões relacionadas ao processamento cognitivo e na FSC de sujeitos Matutinos [F (14; 76303) = 38,92; p<0,05], Intermediários [F(14; 505) = 2,79; p<0,05] e Moderadamente vespertinos [F(14; 279) = 2,75; p<0,05] de acordo com os horários de medida. Concluiu-se que a sensibilidade ao contraste é um aspecto importante para o estudo da percepção visual circadiana, sugerindo que os mecanismos sensórios que processam o contraste visual estão diretamente relacionados à hora e o padrão do cronotipo. (AU)


This study aimed to evaluate the contrast sensitivity curve for the stimuli of vertical sinusoidal grids with spatial frequencies of .2; .6; 1; 3.1; 6.1; 8.8; 13.2 and 15.6 cycles per degree of visual angle, in a 24- hour rhythm of healthy adults of different chronotypes. This study had 18 participants aged 19 to 31 years (M=23.8; SD=3.29) divided into groups according to the chronotype: Morningness (n=5), Intermediate (n=9) and Moderate Eveningness (n=4). Neuropsychological measures and the Metropsis software were used to evaluate the Contrast Sensitivity Function (CSF). CSF measurements were performed by the psychophysical method of forced choice between two spatial alternatives. Results showed significant changes in the dimensions related to cognitive processing and CSF for morning subjects [F (14; 76303) = 38.92; p < .05], Intermediate subjects [F (14, 505) = 2.79; p< .05] and moderately evening subjects [F (14, 279) = 2.75; p< .05] in accordance with the measured time. The study concluded that contrast sensitivity is an important aspect to the study of circadian visual perception, suggesting that the sensorial mechanisms which process visual contrast are directly related to the time and pattern of people's chronotypes.(AU)


Assuntos
Humanos , Masculino , Adolescente , Adulto , Psicofísica , Sensibilidades de Contraste , Ritmo Circadiano , Atenção , Sono , Fadiga
18.
Arq. bras. oftalmol ; 78(3): 150-153, May-Jun/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-753025

RESUMO

ABSTRACT Purpose: The contrast sensitivity (CS) function in patients with primary Sjögren’s syndrome (pSS) may be impaired either frequently as a result of dry eye diseases or rarely as a result of optic neuropathy. In this study, we aimed to evaluate the CS function in pSS patients as well as to assess corneal aberrations and thickness of the peripapillary retinal nerve fiber layer (pRNFL). Methods: Fourteen eyes of 14 pSS patients (pSS group) and 14 eyes of 14 healthy participants (control group) were subjected to assessment of CS at the spatial frequencies of 1.5, 3.0, 6.0, 12, and 18 cycles/degree (cpd) using a functional visual acuity contrast test (FACT); measurement of corneal high-order aberrations (HOAs) in terms of coma-like, spherical-like, and total HOAs using Scheimpflug corneal topography; and measurement of the thickness of both the macular ganglion cell-inner plexiform layer (mGCIPL) and pRNFL in all quadrants using optical coherence tomography. None of the participants were under treatment with artificial tears. Results: The results of the CS test did not differ between the 2 groups at all spatial frequencies (p>0.05). In addition, there were no statistically significant differences between the 2 groups in terms of corneal HOAs (p>0.05) and thickness of mGCIPL (p>0.05). However, among all quadrants, only the inferior quadrant of pRNFL in pSS patients was statistically significantly thinner than that in the healthy participants (p=0.04). Conclusions: The CS function in pSS patients can be maintained with normal thickness of both pRNFL and mGCIPL and with lack of increased corneal HOAs, which may be present even in the absence of artificial tear usage. .


RESUMO Objetivo: A função de sensibilidade ao contraste em pacientes com síndrome de Sjögren primário (pSS) pode ser prejudicada, quer frequentemente como resultado de doenças do olho seco, ou mais raramente como um resultado de neuropatia óptica. Neste estudo, objetivamos avaliar a função de sensibilidade ao contraste de pacientes com pSS, além da avaliação das aberrações da córnea e a espessura da camada de fibras nervosas da retina (pRNFL). Métodos: Catorze olhos de 14 pacientes com pSS e 14 olhos de 14 participantes saudáveis foram submetidos, respectivamente, à avaliação do teste de sensibilidade aos contrastes (CS) nas frequências espaciais de 1,5, 3,0, 6,0, 12 e 18 ciclos/grau (cpd), utilizando teste de contraste acuidade visual funcional (FACT); a medida das aberrações de alta ordem da córnea (HOAs) em termos de coma, aberrações esféricas e aberrações totais, utilizando topografia corneana por Scheimpflug; e medida de espessura da camada de macular de células ganglionares plexiforme interna (mGCIPL) e a espessura de pRNFL em todos os quadrantes usando tomografia de coerência óptica. Nenhum dos participantes estava sob tratamento com lágrimas artificiais. Resultados: O teste CS em pacientes pSS não diferiu do que o teste CS em participantes saudáveis em todas as frequências espaciais (p>0,05). Não houve também nenhuma diferença estatisticamente significativa entre os dois grupos em termos de HOAs da córnea (p>0,05), e espessura de mGCIPL (p>0,05). No entanto, entre todos os quadrantes, apenas o quadrante inferior da pRNFL em pacientes pSS foi significativamente mais fino que o quadrante inferior da pRNFL em participantes saudáveis (p=0,04). Conclusões: A função de CS em doentes com pSS pode ser mantida em condições de ambas as espessuras normais de pRNFL e mGCIPL, assim como nas condições de falta de aumento HOAs da córnea, que pode ser mantida, mesmo na ausência do uso de lágrimas artificiais. .


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidades de Contraste/fisiologia , Síndrome de Sjogren/fisiopatologia , Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Fibras Nervosas , Estudos Prospectivos , Síndrome de Sjogren/diagnóstico , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Testes Visuais/métodos
19.
Rev. bras. enferm ; 68(2): 244-252, Mar-Apr/2015. tab
Artigo em Português | LILACS, BDENF - Enfermagem | ID: lil-752512

RESUMO

RESUMO Objetivo: estudo descritivo, exploratório, de corte transversal, cujo objetivo foi identificar a vulnerabilidade de famílias de idosos assistidos pela Estratégia Saúde da Família (ESF). Método: foi desenvolvido por meio de entrevistas domiciliárias realizadas com uma amostra de 500 famílias de idosos assistidas por 32 equipes da ESF da cidade de Dourados, MS. O Índice de Desenvolvimento da Família (IDF) foi adaptado para classificá-las em função da situação de vulnerabilidade. Resultados: os resultados revelaram a presença de famílias multigeracionais, com baixa escolaridade entre os indivíduos com idade superior a 20 anos e alta taxa de analfabetismo entre os idosos. Identificaram-se 403 famílias em situação de vulnerabilidade aceitável, 95 em vulnerabilidade grave e duas famílias em situação de vulnerabilidade muito grave. As dimensões mais críticas do IDF foram os acessos ao conhecimento e ao trabalho. Conclusão: conclui-se que há necessidade de mais investimentos no cuidado a esses idosos e suas famílias na Atenção Básica. .


RESUMEN Objetivo: estudio descriptivo, exploratorio, transversal, con el objetivo de identificar la vulnerabilidad de familias adultos mayores asistidas por la Estrategia Salud de la Familia (ESF). Método: fue desarrollado mediante entrevistas a una muestra de 500 familias de adultos mayores bajo la responsabilidad de 32 equipos de ESF en la ciudad de Dourados, MS, Brasil. El Índice de Desarrollo de la Familia (IDF) fue adaptado para clasificar las familias de acuerdo a la situación de vulnerabilidad. Resultados: los resultados revelaron la presencia de familias multigeneracionales con bajo nivel de educación entre las personas mayores de 20 años y las altas tasas de analfabetismo entre los adultos mayores. Se identificaron 403 familias en situación de vulnerabilidad aceptable, 95 con vulnerabilidad grave y dos familias en situación de vulnerabilidad muy grave. Las dimensiones más críticas en el IDF fueron el acceso al conocimiento y al trabajo. Conclusión: se concluye que existe la necesidad de una mayor inversión, con un enfoque en la atención primaria, con el fin de atender a las personas mayores y sus familias. .


ABSTRACT Objective: the present descriptive, exploratory, cross-sectional study aimed to identify the vulnerability of families of elderly citizens cared for by the Family Health Strategy (FHS). Method: the research employed home interviews and was developed with a sample of 500 families of aged people cared for by 32 FHS teams in the city of Dourados, MS, Brazil. The Family Development Index (FDI) was adapted in order to classify the families according to their degree of vulnerability. Results: the results revealed the presence of multigenerational families with low educational levels among individuals over the age of 20 and high illiteracy rates among elderly citizens. There were 403 families whose vulnerability was acceptable, 95 in severe vulnerability, and two families in a condition of very severe vulnerability. The most critical dimensions of the FDI were the access to knowledge and to work. Conclusion: the study identifi ed that there is still a need for further investments that can assist these aged people and their families in the Primary Health Care. .


Assuntos
Animais , Masculino , Sensibilidades de Contraste/fisiologia , Percepção de Forma/fisiologia , Macaca mulatta/fisiologia , Córtex Visual/fisiologia , Percepção Visual/fisiologia , Mapeamento Encefálico , Sinais (Psicologia) , Iluminação , Neurônios/citologia , Neurônios/fisiologia , Imagem Óptica , Estimulação Luminosa , Córtex Visual/anatomia & histologia
20.
Arq. bras. oftalmol ; 77(6): 373-376, Nov-Dec/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-735795

RESUMO

Purpose: To evaluate whether implantation of an aspheric intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery and, therefore, changes on frequency-doubling technology (FDT) testing. Methods: The present prospective clinical study enrolled 25 patients with bilateral cataract (50 eyes), who randomly received either an aspheric (Akreos AO) or a spherical (Akreos Fit) IOL in one eye and the other IOL in the second eye. Assessment 12 months postoperatively included photopic and mesopic contrast sensitivity testing. Higher-order aberrations (HOAs) were computed. FDT testing was divided into four areas to evaluate the variation of the values at different points. The median values of the local pattern thresholds (median area contrast sensitivity [MACS]) obtained with that division were calculated. Results: The Akreos AO group obtained statistically significantly lower values of HOAs and spherical aberration compared with the Akreos Fit group. There was a statistically significant between-group difference in contrast sensitivity under mesopic conditions at all spatial frequencies. No statistically significant differences were observed in mean deviation and pattern standard deviation. The aspheric IOL exhibited higher MACS in all areas, although a statistically significant difference was reached only in the 20-degree field area (P=0.043). Conclusion: Aspheric IOLs significantly reduced spherical aberration and HOAs, improving mesopic contrast sensitivity. Although there was a trend toward slightly improved FDT in the aspheric IOL group, it was not statistically significant. .


Objetivo: Avaliar se o implante de uma lente intraocular (LIO) asférica reduz a aberração ocular (alta ordem e esférica), melhora a sensibilidade ao contraste e consequentemente, provoca mudanças nos valores da perimetria de frequência dupla (FDT ). Métodos: Trata-se de um estudo prospectivo envolvendo 25 pacientes com catarata bilateral (50 olhos) que foram randomizados para receberem uma LIO asférica (Akreos AO) em um olho e uma LIO esfércia (Akreos Fit) no olho contralateral. Com 12 meses de pós-operatório a sensibilidade ao contraste (condições fotópicas e mesópicas) e a aberração de alta ordem foram computados. A FDT foi dividida em 4 áreas para análise da variação dos valores em diferentes localizações. Os valores médios dos limiares locais (área média de sensibilidade ao contraste [MACS]) obtidos com essa divisão foram calculados. Resultados: O grupo da Akreos AO apresentou menores valores de aberração de alta ordem e aberração esférica. Houve diferença estatisticamente significativa na sensibilidade ao contraste em condições mesópicas em todas frequências. Não houve diferença estatística nos valores do mean deviation e pattern standard deviation da FDT. A LIO asférica apresentou maiores MACS em todas as áreas, embora diferença estatística foi encontrada apenas na área de 20 graus de campo visual (P=0,043). Conclusões: A lente asférica reduziu significativamente a quantidade de aberração de alta ordem e esférica, melhorando a sensibilidade ao contraste em condições mesópicas. Embora houve uma melhora nos valores da FDT no grupo da LIO asférica, essa diferença não foi estatisticamente significativa. .


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Extração de Catarata/métodos , Lentes Intraoculares , Implante de Lente Intraocular/métodos , Aberrometria , Sensibilidades de Contraste , Catarata/patologia , Catarata/fisiopatologia , Tamanho do Órgão , Estudos Prospectivos , Desenho de Prótese , Pupila/fisiologia , Valores de Referência , Erros de Refração/fisiopatologia , Estatísticas não Paramétricas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...