Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.765
Filtrar
1.
Medicina (Kaunas) ; 60(3)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38541197

RESUMO

Background and Objectives: This study examined how a history of thyroid surgery impacts the precision of cricothyroid membrane (CTM) identification through palpation (validated by ultrasound) in female patients visiting the operating room for surgeries unrelated to neck procedures. Materials and Methods: This prospective observational cohort study enrolled adult female patients undergoing elective non-neck surgery, dividing them into control (no thyroid surgery history; n = 40) and experimental (with thyroid surgery history; n = 40) groups. CTM identification was performed by palpation and confirmed via ultrasound. Results: There were no significant differences between two groups in the demographic characteristics of the patients. The success rate and accuracy of CTM identification through palpation were significantly higher in the control group compared to the experimental group (90% vs. 42.5%, respectively; p < 0.001). For female patients with a history of thyroid surgery, the sensitivity of successful CTM palpation was 42.5%, and the specificity was 10%. These figures are based on the calculated true positives (17), false positives (36), true negatives (4), and false negatives (23). Conclusions: Thyroid surgery history in female patients may hinder the accurate palpation-based identification of the CTM, suggesting a need for enhanced clinical practices and considerations during airway management training.


Assuntos
Cartilagem Cricoide , Glândula Tireoide , Adulto , Humanos , Feminino , Estudos Prospectivos , Cartilagem Cricoide/diagnóstico por imagem , Cartilagem Cricoide/cirurgia , Cartilagem Tireóidea/cirurgia , Cartilagem Tireóidea/diagnóstico por imagem , Ultrassonografia , Palpação/métodos
2.
Catheter Cardiovasc Interv ; 103(5): 722-730, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38469945

RESUMO

BACKGROUND: The radial first approach in cardiac catheterization is preferred for its benefits in patient comfort and recovery time. Yet, challenges persist due to characteristics like small, deep, calcified, and mobile radial arteries. Utilizing ultrasound before and during procedures can improve success rates. However, the adoption of its use is still limited and subject to debate. AIM: To utilize routine preprocedural ultrasound (US) and compare US guided with palpation guided radial access, focusing on operator efficiency and outcomes. METHODS AND RESULTS: Consenting adult patients undergoing elective radial cardiac catheterization were divided into palpation and US groups. Routine preprocedural assessment of radial artery characteristics was performed using handheld US. Baseline data, US findings, procedural outcomes, and clinical outcomes were compared in 182 participants (91 in each group). US guided radial access had significantly higher first pass success rates (76.92% vs. 49.45%, p 0.0001), fewer number of attempts (1.46 ± 1 vs. 1.99 ± 1.46, p 0.004), and shorter amount of time (93.62 ± 44.04 vs. 120.44 ± 67.1, p 0.002) compared with palpation guidance. The palpation group had significantly higher incidence of spasm (15.38% vs. 3.3%, p 0.0052). Subgroup analysis indicated consistent benefits of US guidance, especially in calcified radial arteries. CONCLUSION: This prospective, nonrandomized, single-center study demonstrated that real-time procedural US improved the operator's time and effort and enhanced patient comfort compared with palpation. US guidance use was particularly favorable in the presence of calcifications observed on baseline preoperative US.


Assuntos
Cateterismo Periférico , Adulto , Humanos , Estudos Prospectivos , Resultado do Tratamento , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Palpação/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Ultrassonografia de Intervenção/métodos
3.
J Bodyw Mov Ther ; 37: 1-10, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38432788

RESUMO

BACKGROUND: Static palpation of vertebral spinous process deviations from the midline are often utilized by manual therapists as a means to determine area for treatment of manipulable lesions. Previous research has discussed the diagnostic validity of this technique, but no correlation to vertebral morphology has been presented. AIM: To evaluate the frequency and presentation of vertebral spinous process deviations and their relationship with articular morphology, and the impact this may have in terms of static palpation techniques in the upper thoracic spine. SETTING: This study was conducted on human T1-T6 vertebrae. METHOD: A skeletal sample consisting of 58 humans T1-T6 vertebrae were photographed and linear and angular measurements taken utilizing ImageJ software and non-metric visual observations. RESULTS: Spinous process deviations in the entire sample group (n = 348) were found to occur in a frequency ranging from 19% (n = 11) at T1 to 41.4% (n = 24) at T3. However, when evaluated in terms of frequency within an individual's T1-T6, 83.3% (n = 25) of males and 67.86% (n = 19) of females demonstrated this feature, with an overall incidence of 77.59% (n = 45). Age of individuals did not show an increase in frequency, and no clear pattern could be identified regarding metric measurements and its presence. CONCLUSION: Spinous process deviations in the upper thoracic spine are most probably the result of random normal variations between individuals and are more frequent in males. Static palpation without pain criteria is not a reliable diagnostic technique to determine areas needing manual treatment, as these may be considered normal osseous anatomical variations.


Assuntos
Vértebras Torácicas , Parede Torácica , Feminino , Masculino , Humanos , Pessoal Técnico de Saúde , Dor , Palpação
4.
Comput Biol Med ; 170: 108074, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38330826

RESUMO

Traditional Chinese medicine (TCM) is an essential part of the Chinese medical system and is recognized by the World Health Organization as an important alternative medicine. As an important part of TCM, TCM diagnosis is a method to understand a patient's illness, analyze its state, and identify syndromes. In the long-term clinical diagnosis practice of TCM, four fundamental and effective diagnostic methods of inspection, auscultation-olfaction, inquiry, and palpation (IAOIP) have been formed. However, the diagnostic information in TCM is diverse, and the diagnostic process depends on doctors' experience, which is subject to a high-level subjectivity. At present, the research on the automated diagnosis of TCM based on machine learning is booming. Machine learning, which includes deep learning, is an essential part of artificial intelligence (AI), which provides new ideas for the objective and AI-related research of TCM. This paper aims to review and summarize the current research status of machine learning in TCM diagnosis. First, we review some key factors for the application of machine learning in TCM diagnosis, including data, data preprocessing, machine learning models, and evaluation metrics. Second, we review and summarize the research and applications of machine learning methods in TCM IAOIP and the synthesis of the four diagnostic methods. Finally, we discuss the challenges and research directions of using machine learning methods for TCM diagnosis.


Assuntos
Inteligência Artificial , Medicina Tradicional Chinesa , Humanos , Medicina Tradicional Chinesa/métodos , Olfato , Aprendizado de Máquina , Palpação
5.
J Oral Rehabil ; 51(5): 879-885, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38240374

RESUMO

BACKGROUND: The Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) protocol recommends a 5 s and 1 kg force dynamic palpation around the lateral condylar pole of the temporomandibular joint. However, the accuracy and precision of the generated force are not known. OBJECTIVE: To assess and compare the force profiles generated from dynamic palpation manually and using a palpometer, based on the forces and time recommendations suggested by the DC/TMD protocol. METHODS: Nineteen healthy adults applied forces of 0.5 kg, 1.0 kg and 2.0 kg on a calibrated force sensor in a circular motion within target times of 2 s and 5 s. Participants used their right index finger for manual palpation and a calibrated palpometer for device-assisted palpation. Ten repetitions of each target force at both target times were applied. Time taken to complete each application was recorded. Repeated measures analysis of variance was used for analysis of accuracy measured as the relative difference between targeted force and actual force values and precision measured as the coefficient of variation (CV) within the 10 repeated measurements. RESULTS: Accuracy was significantly lower (better) and precision higher (lower CV) with the palpometer than with manual palpation (p < .001). There were significant differences in accuracy and precision between the different forces but not palpation times. Most participants could not achieve the target times and tended to be faster, irrespective of the palpation method (p > .063). CONCLUSION: A palpometer is a more accurate and precise palpation method for dynamic force assessment compared to manual palpation; however, it remains difficult to standardize the palpation duration.


Assuntos
Dor Facial , Transtornos da Articulação Temporomandibular , Adulto , Humanos , Medição da Dor/métodos , Dor Facial/diagnóstico , Palpação/métodos , Articulação Temporomandibular , Transtornos da Articulação Temporomandibular/diagnóstico
6.
Acad Med ; 99(4S Suppl 1): S89-S94, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38207081

RESUMO

PURPOSE: Successful implementation of precision education systems requires widespread adoption and seamless integration of new technologies with unique data streams that facilitate real-time performance feedback. This paper explores the use of sensor technology to quantify hands-on clinical skills. The goal is to shorten the learning curve through objective and actionable feedback. METHOD: A sensor-enabled clinical breast examination (CBE) simulator was used to capture force and video data from practicing clinicians (N = 152). Force-by-time markers from the sensor data and a machine learning algorithm were used to parse physicians' CBE performance into periods of search and palpation and then these were used to investigate distinguishing characteristics of successful versus unsuccessful attempts to identify masses in CBEs. RESULTS: Mastery performance from successful physicians showed stable levels of speed and force across the entire CBE and a 15% increase in force when in palpation mode compared with search mode. Unsuccessful physicians failed to search with sufficient force to detect deep masses ( F [5,146] = 4.24, P = .001). While similar proportions of male and female physicians reached the highest performance level, males used more force as noted by higher palpation to search force ratios ( t [63] = 2.52, P = .014). CONCLUSIONS: Sensor technology can serve as a useful pathway to assess hands-on clinical skills and provide data-driven feedback. When using a sensor-enabled simulator, the authors found specific haptic approaches that were associated with successful CBE outcomes. Given this study's findings, continued exploration of sensor technology in support of precision education for hands-on clinical skills is warranted.


Assuntos
Palpação , Médicos , Humanos , Masculino , Feminino , Programas de Rastreamento , Mãos
7.
Reg Anesth Pain Med ; 49(1): 41-48, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-37188389

RESUMO

INTRODUCTION: Ultrasonography may facilitate neuraxial blocks in obstetrics. This randomized controlled trial aimed to compare preprocedural ultrasonography with landmark palpation for spinal anesthesia in obese parturients undergoing cesarean delivery. METHODS: 280 American Society of Anesthesiologists (ASA) physical status II-III parturients with body mass index ≥35 kg/m2, full-term singleton pregnancy, undergoing elective cesarean delivery under spinal anesthesia, were randomly assigned to two equal groups (ultrasonography and palpation); preprocedural systematic ultrasound approach and conventional landmark palpation were performed, respectively. Patients and outcome assessors were blinded to the study group. All ultrasound and spinal anesthetic procedures were performed by a single experienced anesthesiologist. The primary outcome was the number of needle passes required to obtain free cerebrospinal fluid (CSF) flow. Secondary outcomes were the number of skin punctures required to obtain free CSF flow, success rate at the first needle pass, success rate at the first skin puncture, duration of the spinal procedure, patient satisfaction and incidence of vascular puncture, paresthesia, failure to obtain CSF flow and failed spinal block. RESULTS: There were no significant differences in primary or secondary outcomes between the two groups. The median (IQR) of the number of needle passes required to obtain free CSF flow was 3 (1-7) in ultrasonography group and 3 (1-7) in palpation group; p=0.62. CONCLUSIONS: Preprocedural ultrasonography did not decrease the number of needle passes required to obtain free CSF flow or improve other outcomes compared with landmark palpation during spinal anesthesia performed by a single experienced anesthesiologist in obese parturients undergoing cesarean delivery. TRIAL REGISTRATION NUMBER: NCT03792191; : https://clinicaltrials.gov/ct2/show/NCT03792191.


Assuntos
Raquianestesia , Gravidez , Feminino , Humanos , Raquianestesia/métodos , Ultrassonografia de Intervenção/métodos , Punção Espinal/métodos , Ultrassonografia , Obesidade/complicações , Obesidade/diagnóstico , Palpação
8.
Endocr Pract ; 30(1): 31-35, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37805101

RESUMO

OBJECTIVE: Thyroid palpation is a common clinical practice to detect thyroid abnormalities. However, its accuracy and potential for additional findings remain unclear. This study aimed to assess the diagnostic accuracy of physical exams in detecting thyroid nodules. METHODS: A retrospective observational study was conducted on a random sample of adult patients who underwent their first-time thyroid ultrasound between January 2015 and September 2017, following a documented thyroid physical exam. The study assessed the performance of thyroid palpation in detecting 1 or multiple thyroid nodules, as well as the proportion of additional findings on ultrasounds due to false positive thyroid palpation. RESULTS: We included 327 patients, mostly female (65.1%), white (84.1%), and treated in a primary care setting (54.4%) with a mean age of 50.8 years (SD 16.9). For solitary thyroid nodules, the physical exam had a sensitivity of 20.3%, specificity of 79.1%, an accuracy of 68.5%, negative predictive value of 81.8%, and positive predictive value of 17.6%. For detecting a multinodular goiter, physical exams demonstrated a sensitivity of 10.8%, specificity of 96.5%, accuracy of 55.4%, negative predictive value of 53.9, and positive predictive value of 73.9%. Among 154 cases with palpable nodules, 60% had additional nodules found in subsequent thyroid ultrasound. CONCLUSION: Thyroid physical exam has limited diagnostic performance and leads to additional findings when followed by a thyroid ultrasound. Future efforts should be directed at improving the accuracy of thyroid physical exams or re-evaluating its routine use.


Assuntos
Bócio , Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Palpação , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Neoplasias da Glândula Tireoide/diagnóstico , Nódulo da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia , Idoso
9.
J Oral Rehabil ; 51(3): 601-610, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37994202

RESUMO

BACKGROUND: The evaluation of muscle pain and sensitivity by manual palpation is an important part of the clinical examination in patients with myalgia. However, the effects of clinical experience and visual feedback on palpation of the masticatory muscles with or without a palpometer are not known. OBJECTIVE: To estimate the effects of clinical experience and visual feedback on the accuracy of palpation in standardized settings. METHODS: Thirty-two dentists (age 35 ± 11 years) classified as either specialists (n = 16) or generalists (n = 16) participated in this experiment. All dentists were instructed to target force levels of 500- or 1000-gf, as determined on an electronic scale using either standardized palpometers or manual palpation (MP). All dentists participated in four different tests: MP, MP with visual feedback (MPVF), palpometer (PAL) and PAL with visual feedback (PALVF). Actual force values for each type of palpation from 0 to 2, 2 to 5 and 0 to 5 s were analysed by calculating target force level. RESULTS: The relative differences during 2-5 and 0-5 s with 1000 gf were significantly lower for generalists than for specialists (p < .05). In generalists and specialists, the coefficients of variation and the relative differences during 2-5 s were significantly lower for PAL and PALVF than for MP (p < .05). CONCLUSIONS: These findings suggest that the use of a palpometer, but not clinical experience with palpation of masticatory muscles, increases the accuracy of palpation, and ≥2 s of palpation with a palpometer is optimal for masticatory muscles.


Assuntos
Retroalimentação Sensorial , Palpação , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Exame Físico , Músculos da Mastigação , Mialgia
10.
Int J Clin Pharm ; 46(2): 529-535, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38151689

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a major cause of stroke in older people. Exacerbated by age and co-morbidities, residents of care homes are more likely to develop AF and less likely to receive oral anticoagulants. AIM: To determine the prevalence of AF using the design and methodology of the Pharmacists Detecting Atrial Fibrillation (PDAF) study in a care home setting. METHOD: A cross-sectional AF screening pilot study within four UK care homes, three residential and one residential/nursing. Screening followed the original PDAF protocol: a manual pulse check, followed by a single-Lead ECG (SLECG, AliveCor Kardia Mobile (KMD)) delivered by a pharmacist. All recorded SLECG were reviewed by a cardiologist and any residents requiring follow-up investigations were referred to their general practitioner. RESULTS: Fifty-three of 112 care home residents participated. From 52 SLECGs recorded, the cardiologist interpreted 13.5% (7/52) as having possible AF of which 9.6% (5/52) were previously unknown. One resident with previously unknown AF received anticoagulation. CONCLUSION: This study has shown a need for AF screening in care homes and that elements of the PDAF screening protocol are transferable in this setting. Early diagnosis and treatment of AF are essential to reduce the risk of stroke in this population.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Projetos Piloto , Estudos Transversais , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Eletrocardiografia , Palpação , Programas de Rastreamento/métodos
11.
J Oral Rehabil ; 51(5): 785-794, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38151896

RESUMO

BACKGROUND: Despite advances in temporomandibular disorders' (TMDs) diagnosis, the diagnostic process continues to be problematic in non-specialist settings. OBJECTIVE: To complete a Delphi process to shorten the Diagnostic Criteria for TMD (DC/TMD) to a brief DC/TMD (bDC/TMD) for expedient clinical diagnosis and initial management. METHODS: An international Delphi panel was created with 23 clinicians representing major specialities, general dentistry and related fields. The process comprised a full day workshop, seven virtual meetings, six rounds of electronic discussion and finally an open consultation at a virtual international symposium. RESULTS: Within the physical axis (Axis 1), the self-report Symptom Questionnaire of the DC/TMD did not require shortening from 14 items for the bDC/TMD. The compulsory use of the TMD pain screener was removed reducing the total number of Axis 1 items by 18%. The DC/TMD Axis 1 10-section examination protocol (25 movements, up to 12 sets of bilateral palpations) was reduced to four sections in the bDC/TMD protocol involving three movements and three sets of palpations. Axis I then resulted in two groups of diagnoses: painful TMD (inclusive of secondary headache), and common joint-related TMD with functional implications. The psychosocial axis (Axis 2) was shortened to an ultra-brief 11 item assessment. CONCLUSION: The bDC/TMD represents a substantially reduced and likely expedited method to establish (grouping) diagnoses in TMDs. This may provide greater utility for settings requiring less granular diagnoses for the implementation of initial treatment, for example non-specialist general dental practice.


Assuntos
Dor Facial , Transtornos da Articulação Temporomandibular , Humanos , Dor Facial/diagnóstico , Cefaleia/diagnóstico , Exame Físico , Palpação
12.
Braz J Phys Ther ; 27(6): 100572, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38043160

RESUMO

BACKGROUND: Vaginal manometry is regarded as an objective method to assess pelvic floor muscles (PFM) function and can measure several variables during contraction. OBJECTIVE: To determine which variables could differentiate women with/without a weak/strong PFM contraction and determine their cut-off points. METHODS: This is a diagnostic accuracy study performed on 156 women with a mean age of 40.4 (SD, 15.9) years. The reference test was vaginal palpation and the index test was vaginal manometry (Peritron™ manometer). Variables were pressure at rest, pressure achieved with maximal voluntary contraction (MVC), MVC average, duration, gradient, and area under the curve (AUCm). The Receiver Operating Curve (AUC/ROC) and logistic regression were used to analyze the data and obtain cut-off points. RESULTS: Excellent ability to discriminate women with a weak/strong PFM contraction was found for MVC average (cut-off: 28.93 cmH2O), MVC (cut-off: 38.61 cmH2O), and the AUCm (cut-off: 1011.93 cm²*s). The gradient variable had good discrimination ability (AUC/ROC=0.81; cut-off: 28.68 cmH2O/s). The MVC average assessed by manometry, menopausal status, and the presence of stress urinary incontinence (SUI) were associated with a weak/strong PFM contraction in the multivariate analysis; however, the most parsimonious model to discriminate weak/strong PFM contraction included only the MVC average (AUC/ROC = 0.95; sensitivity: 0.87; specificity: 0.91). CONCLUSION: These results suggest which manometry variables are appropriate to assess and classify PFM function in females. These could be used to help physical therapists to make clinic decisions about the management of female PFM.


Assuntos
Diafragma da Pelve , Vagina , Feminino , Humanos , Adulto , Diafragma da Pelve/fisiologia , Manometria/métodos , Vagina/fisiologia , Palpação , Contração Muscular/fisiologia
13.
Sci Rep ; 13(1): 23014, 2023 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-38155254

RESUMO

Teleoperated medical technologies are a fundamental part of the healthcare system. From telemedicine to remote surgery, they allow remote diagnosis and treatment. However, the absence of any interface able to effectively reproduce the sense of touch and interaction with the patient prevents the implementation of teleoperated systems for primary care examinations, such as palpation. In this paper, we propose the first reported case of a soft robotic bilateral physical twin for remote palpation. By creating an entirely soft interface that can be used both to control the robot and receive feedback, the proposed device allows the user to achieve remote palpation by simply palpating the soft physical twin. This is achieved through a compact design showcasing 9 pneumatic chambers and exploiting multi-silicone casting to minimize cross-noise and allow teleoperation. A comparative study has been run against a traditional setup, and both the control and feedback of the physical twin are carefully analyzed. Despite distributed tactile feedback not achieving the same performance as the visual map, the soft control and visual feedback combination showcases a 5.1% higher accuracy. Moreover, the bilateral soft physical twin results always in a less invasive procedure, with 41% lower mechanical work exchanged with the remote phantom.


Assuntos
Robótica , Silicones , Humanos , Desenho de Equipamento , Retroalimentação , Palpação , Robótica/métodos , Tato , Interface Usuário-Computador
14.
Sci Rep ; 13(1): 22801, 2023 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-38129463

RESUMO

Through anatomical morphology, to accumulate the relevant parameters of the A1 pulley of each adult finger. A total of 100 fingers were selected, dissected layer by layer, and the A1 pulley and neurovascular of each finger were observed. Measure the length of the A1 pulley, the distance between the needle knife insertion point and the proximal edge of A1 pulley, and the nerves and blood vessels on both sides. (1) The length of A1 pulleys of each finger is 6.18 ± 0.33 mm, 6.58 ± 0.73 mm, 5.98 ± 0.67 mm, 5.36 ± 1.08 mm, 5.63 ± 1.09 mm. (2) The distances between the needle knife entry point of each finger and the volar proper nerve of the ulnar finger are 7.00 ± 1.55 mm, 8.29 ± 1.46 mm, 5.10 ± 0.25 mm, 5.30 ± 0.24 mm, 0 mm; the distances from the volar proper nerve of the radial finger are 9.08 ± 0.87 mm, 4.70 ± 1.10 mm, 7.03 ± 0.72 mm, 6.81 ± 0.22 mm, 7.81 ± 0.57 mm. (3) The distances between the needle knife entry point of each finger and the proper volar artery of the ulnar finger are 10.40 ± 0.75 mm, 8.89 ± 0.53 mm, 6.35 ± 0.44 mm, 7.26 ± 0.16 mm, 0 mm, respectively; The distances from the volar proper artery of the radial finger are 8.75 ± 1.07 mm, 6.10 ± 0.35 mm, 11.44 ± 0.41 mm, 8.19 ± 0.60 mm, 9.78 ± 0.68 mm, respectively. The landmarks of the needle entry points are located at the position corresponding to the highest point of the metacarpal heads, except the tail finger. From the needle knife entry point to distal, cut the proximal edge of the A1 pulley longitudinally along the midline until the patient can flex autonomously, and pay attention to the distance between the two sides of 3.60-11.85 mm neurovascular bundle.


Assuntos
Dedo em Gatilho , Adulto , Humanos , Cadáver , Mãos/anatomia & histologia , Dedos/anatomia & histologia , Palpação
15.
Sci Rep ; 13(1): 23009, 2023 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-38155223

RESUMO

Preprocedural ultrasound assistance can enhance the efficacy of neuraxial anesthesia in obstetrics. We investigated whether the use of handheld ultrasound can shorten the procedural time of labor combined spinal-epidural (CSE) analgesia compared with conventional landmark-guided methods. Eighty-four women requesting labor analgesia were randomly assigned to either handheld ultrasound-assisted or palpation-guided CSE analgesia. Primary outcome was procedure time of the CSE analgesia. Secondary outcomes included identification time, performance time, number of needle manipulations required for epidural/spinal success, first-attempt success rate, periprocedural pain scores, the incidence of accidental dural puncture, and patient satisfaction. Total procedure time did not significantly differ between the ultrasound and palpation groups (median [IQR], 191.5 [167-224] vs. 204.5 [163-358] s; P = 0.442). However, the performance time was significantly shorter in the ultrasound group (134.5 [115-177] vs. 183 [129-296] s; P = 0.011), although identification time was longer in the ultrasound group (53 [41-72] vs. 30.5 [21-45] s; P < 0.001). The epidural success rate at first insertion attempt was higher in the ultrasound group (85.7% vs. 59.5%, P = 0.014). Preprocedural handheld ultrasound assistance resulted in equivalent total procedure times but reduced performance times and higher first-attempt success rates. Therefore, clinicians may consider this technique for labor CSE analgesia.Trial registration: NCT04759547.


Assuntos
Analgesia Epidural , Raquianestesia , Gravidez , Humanos , Feminino , Ultrassonografia de Intervenção/métodos , Raquianestesia/métodos , Punção Espinal , Analgesia Epidural/métodos , Palpação
16.
BMC Med Educ ; 23(1): 897, 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-37996904

RESUMO

OBJECTIVES: Abdominal palpation is an essential examination to diagnose various digestive system diseases. This study aimed to develop an objective and standardized test based on abdominal palpation simulators, and establish a credible pass/fail standard of basic competency. METHODS: Two tests were designed using the newly developed Jucheng abdominal palpation simulator (test 1) and the AbSim simulator (test 2), respectively. Validity evidence for both tests was gathered according to Messick's contemporary framework by using experts to define test content and then administering the tests in a highly standardized way to participants of different experience. Different simulator setups modified by the built-in software were selected from hepatomegaly, splenomegaly, positive McBurney's sign plus rebound tenderness, gallbladder tenderness (Murphy's sign), pancreas tenderness, and a normal setup without pathologies, with six sets used in test 1 and five sets used in test 2. Different novices and experienced were included in the tests, and test 1 was also administered to an intermediate group. Scores and test time were collected and analyzed statistically. RESULTS: The internal consistency reliability of test 1 and test 2 showed low Cronbach's alphas of 0.35 and -0.41, respectively. Cronbach's alpha for palpation time across cases were 0.65 for test 1 and 0.76 for test 2. There was no statistical difference in total time spent and total scores among the three groups in test 1 (P-values (ANOVA) were 0.53 and 0.35 respectively), nor between novices and experienced groups in test 2 (P-values (t-test) were 0.13 and 1.0 respectively). It was not relevant to try to establish pass/fail standards due to the low reliability and lack of discriminatory ability of the tests. CONCLUSIONS: It was not possible to measure abdominal palpation skills in a valid way using either of the two standardized, simulation-based tests in our study. Assessment of the patient's abdomen using palpation is a challenging clinical skill that is difficult to simulate as it highly relies on tactile sensations and adequate responsiveness from the patients.


Assuntos
Abdome , Software , Humanos , Reprodutibilidade dos Testes , Simulação por Computador , Competência Clínica , Palpação
17.
Cir Cir ; 91(5): 633-640, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37844890

RESUMO

OBJECTIVE: The aim of this study was compare the palpation technique and ultrasound-guidance for femoral artery catheterization in pediatric patients undergoing surgery for congenital heart disease. MATERIALS AND METHODS: This prospective and randomized controlled study included American Society of Anesthesiologists III-IV 40 children who underwent congenital heart surgery. The patients were divided into two groups; ultrasound-guided catheterization group and palpation-guided catheterization group. Demographic and clinical characteristics of the patients, access time, success rate, number of attempts, first-attempt success, number of trials, and failed cannulations were recorded. RESULTS: The diameter of the femoral artery was significantly shorter, access time and numbers of trials were significantly lower, and first-attempt success rate was significantly higher in the US group. The complication rate was significantly higher in the P group. The number of failed catheterization was higher in the P group. Total cost required for the procedure was significantly lower in the US group. CONCLUSION: We found that ultrasound-guided arterial catheterization increases the success rate and the number of successful catheterizations, while reducing the overall procedure time, incidence of complications, and cost. Therefore, we believe that the use of ultrasound guidance in arterial catheterization in pediatric cardiac surgery would be a better choice.


OBJETIVO: El objetivo de este estudio fue comparar la técnica de palpación y ecoguiado para el cateterismo de la arteria femoral en pacientes pediátricos operados de cardiopatías congénitas. MATERIALES Y MÉTODOS: Este estudio prospectivo, aleatorizado y controlado incluyó a 40 niños ASA III-IV que se sometieron a cirugía cardíaca congénita. Los pacientes se dividieron en 2 grupos; Grupo de cateterismo guiado por ecografía y grupo de cateterismo guiado por palpación. RESULTADOS: El diámetro de la arteria femoral fue significativamente más corto, el tiempo de acceso y el número de intentos fueron significativamente menores y la tasa de éxito del primer intento fue significativamente mayor en grupo estadounidense. La tasa de complicaciones fue significativamente mayor en el grupo P. El número de cateterismos fallidos fue mayor en el grupo P. El costo total requerido para el procedimiento fue significativamente menor en el grupo de EE. CONCLUSIONES: Encontramos que el cateterismo arterial guiado por ultrasonido aumenta la tasa de éxito y el número de cateterismos exitosos, al tiempo que reduce el tiempo total del procedimiento, la incidencia de complicaciones y el costo. Por tanto, creemos que el uso de guía ecográfica en cateterismo arterial en cirugía cardiaca pediátrica sería una mejor opción.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cateterismo Periférico , Humanos , Criança , Artéria Femoral/diagnóstico por imagem , Estudos Prospectivos , Cateterismo Periférico/métodos , Ultrassonografia de Intervenção/métodos , Palpação
18.
Ulus Travma Acil Cerrahi Derg ; 29(10): 1075-1080, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37791446

RESUMO

BACKGROUND: Percutaneous tracheostomy (PT) may be required frequently in long-term ventilated intensive care patients. Although the overall risks are low, serious complications may occur, especially in children. Hence, this study aimed to assess physician accuracy in identifying PT insertion sites by digital palpation in children aged between 5 and 13 years. METHODS: Participants were asked to identify the needle entry point (interspace between 2nd and 3rd or 3rd and 4th tracheal rings) for PT using digital palpation. Then, a single operator scanned the neck of each child with a linear high-frequency transducer. An accurate estimation was defined as a mark made between the upper and lower borders of the tracheal rings within the midline. RESULTS: In the study including 104 patients, the PT insertion site was accurately identified with digital palpation in a total of 50.9% of patients, compared with sonographic findings. The time required to determine the PT entry point by USG was longer than the palpation technique (114.7 vs. 43.8 s, P<0.001). The mean distance between the entry points of both methods was 4.53±2.03 mm. The majority of inaccurate assessments (45%) was above the 2nd tracheal ring. The lower the skin-to-air-mucosal interface distance, the higher the success of the PT entry point detection with the digital palpation method. A one-unit increase in body mass index was related to increasing the risk of failure by 1.1 times (P=0.030). CONCLUSION: Significant physician inaccuracy exists in PT insertion sites in children aged between 5 and 13 years, especially as BMI increases. Pre-procedural USG may help identify the landmarks for PT.


Assuntos
Médicos , Traqueostomia , Humanos , Criança , Pré-Escolar , Adolescente , Traqueostomia/efeitos adversos , Traqueostomia/métodos , Índice de Massa Corporal , Palpação/métodos
19.
BMC Womens Health ; 23(1): 511, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37743485

RESUMO

BACKGROUND: Breast cancer (BC) is the most commonly diagnosed cancer and the leading cause of cancer death among women. Knowledge of the clinical characteristics of BC in a population may be informative for disease prediction or diagnosis and for developing screening and diagnostic guidelines. This study aimed to evaluate the clinical characteristics of female patients with BC who were admitted to academic surgical wards in Tehran, Iran. METHODS: In this cross-sectional study, demographic information and clinical characteristics of Iranian females with BC who had undergone breast surgery from 2017-2021 in four academic Breast Surgery Units were extracted from medical files and recorded via a pre-designed checklist. RESULTS: A total of 1476 patients with a mean age of 48.03 (± 11.46) years were enrolled. Among them, 10.4% were aged less than 35. In younger patients, Triple-negative and Her2-enriched subtypes of BC were significantly higher compared to older ones. Overall, 85.7% of tumors were invasive ductal carcinoma, 43.3% were grade 2, 41.4% were located in the UOQ, and 65.2% had presented with mass palpation. The mean pathologic tumor size was 28.94 mm, and the most common subtype was luminal B. CONCLUSIONS: Many characteristics of breast cancer in this study were similar to other countries and previous studies in Iran. However, a higher proportion of young BC compared with Western countries, and even with older studies in Iran, suggest a trend toward lower age for BC in recent years. These results indicate the need for preventive measures and screening in Iranian women at a younger age.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/epidemiologia , Irã (Geográfico)/epidemiologia , Estudos Transversais , Hospitalização , Palpação
20.
Sensors (Basel) ; 23(16)2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37631726

RESUMO

"Muscle tone" is a clinically important and widely used term and palpation is a crucial skill for its diagnosis. However, the term is defined rather vaguely, and palpation is not measurable objectively. Therefore, several methods have been developed to measure muscle tone objectively, in terms of biomechanical properties of the muscle. This article aims to summarize these approaches. Through database searches, we identified those studies related to objective muscle tone measurement in vivo, in situ. Based on them, we described existing methods and devices and compared their reliability. Furthermore, we presented an extensive list of the use of these methods in different fields of research. Although it is believed by some authors that palpation cannot be replaced by a mechanical device, several methods have already proved their utility in muscle biomechanical property diagnosis. There appear to be two issues preventing wider usage of these objective methods in clinical practice. Firstly, a high variability of their reliability, and secondly, a lack of valid mathematical models that would provide the observed mechanical characteristics with a clear physical significance and allow the results to be compared with each other.


Assuntos
Tono Muscular , Músculos , Reprodutibilidade dos Testes , Bases de Dados Factuais , Palpação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...