Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.323
Filtrar
1.
Transfusion ; 64(4): 627-637, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38476028

RESUMO

BACKGROUND: Transfusion-related errors are largely preventable but may lead to blood product wastage and adverse reactions, resulting in patient harm. In the United States, the incidence of transfusion-related errors is poorly understood nationally. We used data from the National Healthcare Safety Network (NHSN) Hemovigilance Module to describe and quantify transfusion-related errors, as well as associated transfusion-related adverse reactions and blood product wastage. METHODS: During 2014-2022, data from the NHSN Hemovigilance Module were used to analyze errors, including near misses (errors with no transfusion), incidents (errors with transfusion), and associated serious adverse reactions (severe, life-threatening, or death). RESULTS: During 2014-2022, 80 acute care facilities (75 adult; 5 pediatric) reported 63,900 errors. Most errors occurred during patient blood sample collection (21,761, 34.1%) and blood sample handling (16,277, 25.5%). Less than one-fifth of reported errors (9822, 15.4%) had a completed incident form. Of those, 8780 (89.3%) were near misses and 1042 (10.7%) incidents. More than a third of near misses (3363, 38.3%) were associated with a discarded blood product, resulting in 4862 discarded components. Overall, 87 adverse reactions were associated with errors; six (7%) were serious. CONCLUSIONS: Over half of the transfusion-related errors reported to the Hemovigilance Module occurred during blood sample collection or sample handling. Some serious adverse reactions identified were associated with errors, suggesting that additional safety interventions may be beneficial. Increased participation in the Hemovigilance Module could enhance generalizability and further inform policy development regarding error prevention.


Assuntos
Segurança do Sangue , Reação Transfusional , Humanos , Criança , Reação Transfusional/epidemiologia , Reação Transfusional/etiologia , Transfusão de Sangue , Bancos de Sangue , Atenção à Saúde
2.
Transfus Clin Biol ; 31(2): 114-118, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38460837

RESUMO

The field of haemovigilance continues to develop, building on more than forty years of international experience. This review considers the current scope and activities of haemovigilance around the world and explores aspects of preparation for the advent of new blood products and alternative therapies to transfusion; new tools for data acquisition (including patient- and donor-reported outcomes, and data from 'wearables') and the analysis and communication of haemovigilance results.


Assuntos
Segurança do Sangue , Transfusão de Sangue , Humanos , Segurança do Sangue/métodos , Bancos de Sangue , Doadores de Sangue , Previsões
3.
Vox Sang ; 119(3): 252-256, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38245853

RESUMO

BACKGROUND AND OBJECTIVES: Transfusion-related hepatitis B infections have been reduced significantly with the implementation of blood screening using both serology and nucleic acid amplification technology (NAT) in developed countries. However, in resource-constrained countries, where NAT is inaccessible, the risk persists from early acute and occult cases. This study aimed to determine the antibodies to hepatitis B core antigen (anti-HBc) reactive rate among hepatitis B surface antigen (HBsAg)-screened negative blood donors and its impact on blood safety in the Philippines. MATERIALS AND METHODS: A total of 1602 HBsAg-negative samples, randomly collected from nine leading blood service facilities representative of each region in the Philippines, were tested for anti-HBc immunoglobulin M (IgM), Total and antibodies to HBsAg (anti-HBs) using the Architect i2000SR Immunoassay Analyser (Abbott Laboratories, IL). Anti-HBc IgM and/or Total repeat reactive were further tested for hepatitis B virus (HBV) NAT using the Cobas TaqScreen MPX v2.0 (Roche Diagnostics, Basel). RESULTS: Overall, 19.16% HBsAg-negative samples (n = 307/1602) were reactive for either anti-HBc IgM or Total or a combination of both, of which 1.3% (n = 4/307) had detectable HBV-DNA and 80.5% (n = 247/307) were anti-HBs positive. About the anti-HBs titres, 30.27% (n = 485/1602) were positive (≥10 IU/L) with 55.67% (n = 270/485) having titres ≥100 IU/L. Anti-HBs-only-positive samples were 14.85% (n = 238/1602). CONCLUSION: We observed a high anti-HBc reactive rate (19.16%) with 3.7% anti-HBc-only reactive (anti-HBs negative) and 1.3% HBV-DNA positive. This warrants the need to reconsider existing screening practices to improve blood safety in the country.


Assuntos
Antígenos do Núcleo do Vírus da Hepatite B , Hepatite B , Humanos , Antígenos de Superfície da Hepatite B , Segurança do Sangue , Doadores de Sangue , DNA Viral , Vírus da Hepatite B/genética , Anticorpos Anti-Hepatite B , Hepatite B/diagnóstico , Imunoglobulina M
4.
Viruses ; 16(1)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38257823

RESUMO

Blood safety remains a paramount public health concern, and health authorities maintain a high level of vigilance to prevent transfusion-transmitted infections (TTIs) [...].


Assuntos
Segurança do Sangue , Saúde Pública , Humanos
5.
Transfus Clin Biol ; 31(2): 108-113, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38218342

RESUMO

Transfusion therapy is an indispensable form of treatment, and an important element of the public health system. Due to its origin, blood's clinical use is associated with various risks that may cause adverse reactions and events. Progress in quality and safety of blood components has eliminated numerous risks, especially those of infectious origin. However, some risks cannot be predicted, while others cannot always be prevented. Globalisation and climate change constantly favour the spread of infectious agents. Against this, epidemiology plays a central role in ensuring the safety of transfusion treatment, by continuous surveillance and timely identification of risks, and in the development of routine and additional tests as measures for risk mitigation. As a quantitative discipline based on research methods, epidemiology is a method of reasoning; it relies on the generation and testing of hypotheses; it utilises other scientific resources, particularly in the field of blood donation and blood transfusion, thus having many applications. The main focus falls on transfusion-transmissible infections, and on environmental or occupational diseases, injuries, disabilities and death causes at large. The practice of epidemiology relies on a systematic approach and measurement of disease frequencies. Surveillance is a key element, involving continuously gathering, analysing, and evaluating data regarding diseases, morbidity and mortality, and disseminating the conclusions of the analyses to relevant competent authorities; in this way, action is taken for disease prevention and control. Surveillance systems also provide an important tool for risk assessment, a method to assess and characterise the critical parameters in the functionality of equipment, systems or processes of using scientific data in order to estimate the magnitude of any health effect that derives from decisions of policy makers. Epidemiological surveillance, particularly for the incidence of adverse reactions and adverse events associated with blood transfusion at the national and international levels, has demonstrated the importance of multidisciplinary cooperation between blood and public health services.


Assuntos
Medicina Transfusional , Reação Transfusional , Humanos , Reação Transfusional/epidemiologia , Transfusão de Sangue , Transfusão de Componentes Sanguíneos , Segurança do Sangue
6.
Vox Sang ; 119(2): 102-109, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37872819

RESUMO

Industrial plasma fractionation, a complex and highly regulated technology, remains largely inaccessible to many low- and middle-income countries (LMICs). This, combined with the limited availability and high cost of plasma-derived medicinal products (PDMPs), creates deficiency of access to adequate treatment for patients in resource-limited countries, and leads to their suffering. Meanwhile, an increasing number of LMICs produce surplus plasma, as a by-product of red blood cell preparation from whole blood, that is discarded because of the lack of suitability for fractionation. This article reviews pragmatic technological options for processing plasma collected from LMICs into therapies and supports a realistic stepwise approach aligned with recent World Health Organization guidance and initiatives launched by the Working Party for Global Blood Safety of the International Society of Blood Transfusion. When industrial options based on contract or toll plasma fractionation programme and, even more, domestic fractionation facilities require larger volumes of quality plasma than is produced, alternative methods should be considered. In-bag minipool or small-scale production procedures implementable in blood establishments or national service centres are the only realistic options available to gradually reduce plasma wastage, provide safer treatments for patients currently treated with non-pathogen-reduced blood products and concurrently improve Good Manufacturing Practice (GMP) levels with minimum capital investment. As a next step, when the available volume of quality-assured plasma reaches the necessary thresholds, LMICs could consider engaging with an established fractionator in a fractionation agreement or a contract in support of a domestic fractionation facility to improve the domestic PDMP supply and patients' treatment.


Assuntos
Proteínas Sanguíneas , Países em Desenvolvimento , Humanos , Proteínas Sanguíneas/uso terapêutico , Transfusão de Sangue , Plasma , Segurança do Sangue
7.
Vox Sang ; 119(2): 166-170, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38050721

RESUMO

BACKGROUND AND OBJECTIVES: Plasma-derived medicinal products (PDMPs) are essential to treat many chronic conditions such as haemophilia and primary immunodeficiency. Patients living in low middle-income and low-income countries (LMICs and LICs, respectively) have limited access to PDMPs. The aim of this article is to explore the challenges of accessing PDMPs in LMICs and LICs. MATERIALS AND METHODS: A review of the literature and reports on blood safety, plasma production and its utilization to produce PDMPs in LMICs and LICs was carried out. RESULTS: There is huge wastage of recovered plasma in LMICs and LICs as a result of a lack of good manufacturing practice (GMP) in the production of plasma for fractionation. Together with the high cost of imported PDMP procurement, patients have limited access to such products. CONCLUSION: There is a need to improve the situation by using domestically sourced plasma through the initiation of local plasma programmes through a stepwise approach to improve access to PDMPs in LMICs and LICs.


Assuntos
Segurança do Sangue , Plasma , Humanos , Países em Desenvolvimento , Segurança do Sangue/normas
9.
Vox Sang ; 119(3): 277-281, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38126141

RESUMO

BACKGROUND AND OBJECTIVES: Haemovigilance systems are intended to collect and analyse data, and report findings relating to transfusion complications, such as blood product safety, procedural incidents, and adverse reactions in donors and patients. A common problem among developing haemovigilance programs is the lack of resources and tools available to countries striving to establish or enhance their haemovigilance system. MATERIALS AND METHODS: World Health Organization, in collaboration with International Society for Blood Transfusion (ISBT), International Haemovigilance Network and other haemovigilance experts embarked on a Haemovigilance Tools Project to collect and provide materials and resources to assist with the stepwise implementation of haemovigilance. RESULTS AND CONCLUSIONS: Resources are housed as a virtual compendium on the ISBT website under the Haemovigilance Working Party. These are managed by a subcommittee of the Working Party and are freely available and downloadable to all without requiring ISBT membership.


Assuntos
Segurança do Sangue , Reação Transfusional , Humanos , Segurança do Sangue/métodos , Transfusão de Sangue , Doadores de Sangue
10.
Transfusion ; 64(2): 200-209, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38158876

RESUMO

BACKGROUND: Use of the National Healthcare Safety Network (NHSN) has been essential to the success of the Massachusetts Hemovigilance Program and has allowed for the timely identification of signals and trends over a defined population that correlate with national and international hemovigilance (HV) data. Here, we outline how the NHSN system is used for monitoring HV data in Massachusetts and encourage adoption of NHSN for nationwide HV surveillance. STUDY DESIGN AND METHODS: A collaboration that grew over time between local HV stakeholders and the Massachusetts Department of Public Health (MDPH) resulted in the change from a paper-based method of reporting adverse reactions and monthly transfusion activity for compliance with state requirements to replacement with statewide adoption of reporting via NHSN. RESULTS: Over 1.5 million blood products were transfused in Massachusetts between 2017 and 2021, with 3000 adverse reactions among 10 defined types reported. Using NHSN, MDPH has been able to produce numerous reports, publications, and presentations that have made previously non-obtainable HV and blood utilization data available. DISCUSSION: Although limitations to these self-reported data exist, such as lack of external validation, successful statewide implementation of NHSN for hospital blood bank reporting is possible and has benefits beyond those for regulatory oversight. It results in standardized, actionable data at both the hospital and state level, enabling inter-facility comparisons, benchmarking, and opportunities for practice improvement.


Assuntos
Segurança do Sangue , Transfusão de Sangue , Humanos , Bancos de Sangue , Massachusetts , Atenção à Saúde
11.
Transfusion ; 63(12): 2273-2280, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37909172

RESUMO

INTRODUCTION: In 2018, platelet (PLT) additive solution-E (PAS-E) was introduced. The implementation of PAS-E was expected to diminish the number of allergic reactions in recipients following a PLT transfusion. Here, we evaluated the efficacy and safety of transfusions with PLTs stored in PAS-E. STUDY DESIGN AND METHODS: After implementation of PAS-E, data were collected from 2 cohorts of patients with hematological disorders as well as oncology patients, receiving PLTs in PAS-E. A similar patient group in a recent RCT, receiving PLTs in plasma, was used as a historical control group for both cohorts. Endpoints were corrected count increments (CCIs), bleeding scores (only reported in cohort 1), and the incidence of adverse reactions. RESULTS: In cohort 1, the mean 1-h CCI was 14.3 ± 6.9, and the 24-h CCI was 8.7 ± 5.6. In cohort 2, the 1-h CCI was 11.6 ± 7.8 and the 24-h CCI was 7.0 ± 6.1. In the control group, the 1-h CCI was 15.4 ± 5.5 and 24-h CCI 8.7 ± 4.8. Bleeding complications of WHO grade ≥2 occurred in 40% of patients in cohort 1 compared to 44% in plasma PCs. The incidence of adverse reactions was 1.2% in the two PAS-E cohorts, compared to 3.0% in plasma PCs. National hemovigilance data showed a significant reduction in allergic reactions with PAS-E PC transfusions as compared to plasma PCs with an odds ratio of 0.46 (CI 95% 0.37-0.58). CONCLUSION: The CCIs of PLTs in PAS-E were decreased compared to plasma PCs, but clinically acceptable. Allergic transfusion reactions were decreased in PAS-E PCs compared to plasma PCs.


Assuntos
Hipersensibilidade , Reação Transfusional , Humanos , Plaquetas , Transfusão de Plaquetas/efeitos adversos , Segurança do Sangue , Reação Transfusional/etiologia , Preservação de Sangue , Hipersensibilidade/etiologia
12.
BMC Health Serv Res ; 23(1): 1169, 2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37891622

RESUMO

BACKGROUND AND PURPOSE: Hemovigilance is a set of monitoring methods that covers the blood transfusion chain, from collecting blood and blood products to monitoring the blood recipients. To this end, any error in this process can have serious and irreparable consequences for patients. The present study aimed to investigate the quality of hemovigilance process in Iran, using the first two steps of Six Sigma model. METHODS: This was a quantitative cross-sectional study that was conducted over 6 months (from August 20, 2021, to February 20, 2022) at Afzalipour Hospital in Iran, using the first two steps of Six Sigma model. The study population comprised of all inpatients who needed blood or blood product transfusion in various departments of Afzalipour Hospital, among whom 477 patients were selected via stratified sampling in three shifts (morning, evening, and night). The datasheet was used to record errors in the three shifts. This research was conducted, using the DMAIC cycle's "define" and "measure" steps. RESULTS: In the define step, the hemovigilance process at Afzalipour Hospital was divided into two categories of normal process and emergency process. Each of these processes consists of several sub-processes, including "phlebotomy," "requesting blood and blood products from the department," "preparation of application by the blood bank," " sending a request from the blood bank to the blood transfusion center," "transfusing blood and blood products," and "returning the blood and blood products to the blood bank and waste disposal." In the measure step, the quality of hemovigilance process was evaluated based on sub-processes and labels at morning, evening and night shifts. The sub-process of sending a request from the blood bank to the blood transfusion center had the highest error rate with a sigma level of 1.5. Also, the evening and night shifts had a sigma level of 1.875, and the clinical and registration labels had a sigma level of 1.875. The overall sigma level of hemovigilance process was calculated to be 2. CONCLUSION: The results of this study showed that the quality of hemovigilance process at Afzalipour Hospital was poor. By employing the first two steps of Six Sigma method, we identified the existing errors in the hemovigilance process of Afzalipour hospital in order to assist hospital managers to take the necessary measures to improve this process.


Assuntos
Segurança do Sangue , Gestão da Qualidade Total , Humanos , Estudos Transversais , Transfusão de Sangue , Bancos de Sangue
13.
Vox Sang ; 118(12): 1078-1085, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37850301

RESUMO

BACKGROUND AND OBJECTIVES: Voluntary non-remunerated blood donors (VNRBDs) are recognized as being crucial for the safety and sustainability of national blood supplies. Systems based on replacement donors (RDs) pose high risks of transfusion transmissible infections (TTIs). Currently, only 10%-13% of blood donations are voluntary in Pakistan. No large-scale studies have been conducted to objectively evaluate the impact of the mode of donation on the frequency of TTIs, a gap this study aimed to fill. MATERIALS AND METHODS: The study was conducted at the Indus Hospital, Karachi. Data from a total of 591,820 blood donations were included from 1 October 2017 to 30 May 2021 and evaluated for type of donations and results of TTI testing, primarily performed on Architect i2000SR (Abbott). The TTIs tested include hepatitis B virus, hepatitis C virus, human immunodeficiency virus, syphilis and malaria. RESULTS: A total of 477,938 (80.7%) RDs and 113,882 (19.3%) VNRBDs were screened. Among these, 53,590 (9.06%) were positive for TTIs. There were 10.2% positive RDs (10.08-10.25 95% confidence interval [CI]) while 4.4% in VNRBDs (4.29-4.53 95% CI). Co-infections were observed in 2367 (0.4%) RDs, while 159 (0.02%) in VNRBDs. Geographically, the highest frequency of TTIs was observed in semi-urban areas of Sindh (11.2%) and Punjab (9.6%). A site-wise comparison of TTIs in RD versus VNRBD showed significant differences (p-value 0.00). CONCLUSION: RDs are associated with higher frequencies of TTIs, compared with VNRBD. However, the study was unable to assess whether the significant difference was related to individual risk or repeat/first time status of the donors. Other important variables affecting frequency are the catchment area of the blood donors in Pakistan. Urban areas have less prevalence than semi-urban areas.


Assuntos
Infecções por HIV , Hepatite B , Hepatite C , Sífilis , Reação Transfusional , Humanos , Segurança do Sangue , Doadores de Sangue , Doação de Sangue , Reação Transfusional/epidemiologia , Paquistão/epidemiologia , Hepatite C/epidemiologia , Sífilis/epidemiologia , Infecções por HIV/epidemiologia , Prevalência , Hepatite B/epidemiologia
14.
15.
Transfusion ; 63(10): 1859-1871, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37711059

RESUMO

BACKGROUND: Hemovigilance (HV) is usually based on voluntary reports (passive HV). Our aim is to ascertain credible incidence, severity, and mortality of transfusion-associated adverse events (TAAEs) using an active HV program. STUDY DESIGN AND METHODS: Prospective cohort study to estimate transfusion risk after 46,488 transfusions in 5830 patients, using an active HV program with follow-up within the first 24 h after transfusion. We compared these results to those with the previously established passive HV program during the same 30 months of the study. We explored factors associated with the occurrence of TAAEs using generalized estimating equations models. RESULTS: With the active HV program TAAEs incidence was 57.3 (95% CI, 50.5-64.2) and mortality 1.1 (95% CI, 0.13-2.01) per 10,000 transfusions. Incidence with the new surveillance model was 14.0 times higher than with the passive. Most events occurred when transfusions had already finished (60.2%); especially pulmonary events (80.4%). Three out of five deaths and 50.3% of severe TAAEs were pulmonary. In the multivariate analysis surgical patients had half TAAEs risk when compared to medical patients (OR, 0.53; 95% CI, 0.34-0.78) and women had nearly twice the risk of a pulmonary event compared to men (OR, 1.84; 95% CI, 1.03-3.32). Patient's age, blood component type, or blood component shelf-life were unrelated to TAAEs risk. DISCUSSION: Active hemovigilance programs provide additional data which may lead to better recognition and understanding of TAAEs and their frequency and severity.


Assuntos
Segurança do Sangue , Transfusão de Sangue , Masculino , Humanos , Feminino , Incidência , Estudos Prospectivos , Seguimentos
16.
Transfus Med ; 33(6): 433-439, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37776051

RESUMO

OBJECTIVES: To understand the use, functionality and interoperability of laboratory information management systems (LIMS) in UK transfusion laboratories. BACKGROUND: LIMS are widely used to support safe transfusion practice. LIMS have the potential to reduce the risk of laboratory error using algorithms, flags and alerts that support compliance with best practice guidelines and regulatory standards. Reporting to Serious Hazards of Transfusion (SHOT), the United Kingdom (UK) haemovigilance scheme, has identified cases where the LIMS could have prevented errors but did not. Shared care of patients across different organisations and the development of pathology networks has raised challenges relating to interoperability of IT systems both within, and between, organisations. METHODS AND MATERIALS: A survey was distributed to all SHOT-reporting organisations to understand the current state of LIMS in the UK, prevalence of expertise in transfusion IT, and barriers to progress. Survey questions covered LIMS interoperability with other IT systems used in the healthcare setting. RESULTS: A variety of LIMS and version numbers are in use in transfusion laboratories, LIMS are not always updated due to resource constraints. Respondents identified interoperability and improved functionality as the main requirements for transfusion safety. CONCLUSION: A nationally agreed set of minimum standards for transfusion LIMS is required for safe practice. Adequate resources, training and expertise should be provided to support the effective use and timely updates of LIMS. A single LIMS solution should be in place for transfusion laboratories working within a network and interoperability with other systems should be explored to further improve practice.


Assuntos
Segurança do Sangue , Transfusão de Sangue , Humanos , Reino Unido , Laboratórios , Gestão da Informação
17.
Vox Sang ; 118(9): 721-729, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37533234

RESUMO

BACKGROUND AND OBJECTIVES: The severity grading tool (SGT) was recently designed by the Association for Advancement of Blood and Biotherapies (AABB) to have more objectivity in severity assignment for an adverse donor reaction after blood donation. A study was performed in India to assess the knowledge (post-training) and determine the degree of agreement of the SGT between participating centres and the subject expert group. MATERIALS AND METHODS: This prospective cross-sectional survey-based study was conducted by the National Coordinating Centre (NCC) of the National Blood Donor Vigilance Programme (NBDVP) of India. Thirty-five real-world case scenarios, validated by seven national and two international experts, were sent to the participating centres, and their responses received (diagnosis and severity grade) were compared and analysed. RESULTS: A total of 50 blood centres participated in the study. The overall agreement between the participating centres and the expert group was 66.4%, with a fair Kendall's coefficient of concordance (W) of 0.271 (p-value < 0.05). The degree of agreement was observed to be more than 80% for 12 centres, 60%-80% for 27 centres and <60% for 11 centres. The overall degree/percentage of agreement for cases with single and multiple types of donor adverse reaction was 71.3% and 42.6%, respectively. CONCLUSION: The SGT will be an efficient mode to have uniform objective reporting of the adverse donor reactions and may be implemented in the NBDVP of India. This study also highlights the need for training of the blood centres on the basic definitions and categorization of the donor's adverse reaction.


Assuntos
Doadores de Sangue , Segurança do Sangue , Humanos , Estudos Prospectivos , Estudos Transversais , Índia
18.
J Med Virol ; 95(8): e29006, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37548473

RESUMO

A small percentage of couples who regularly donated blood in China tested positive for HBsAg. Although it is well known that blood donors can acquire hepatitis B virus (HBV) infection from a chronically infected sexual partner, the prevalence of occult hepatitis B infections (OBIs) among blood donations from partners of HBV-infected chronically infected spouses and the risk to blood safety remain poorly understood. Among 212 763 blood donors, 54 pairs of couples (108 donations) were enrolled because one partner tested positive for HBsAg. Several molecular and serological examinations were conducted. The origin of HBV transmission between sexual partners was investigated further. Also evaluated was the potential risk of HBV infection with OBIs. We identified 10 (10/54, 18.6%) sexual partners of chronically infected HBV donors who were positive for HBV DNA, including five samples (9.3%) with OBIs, of which 3 (3/54, 5.6%, 1 in 70 921 donations) passed the routine blood screening tests. Seven of the 10 HBV-DNA-positive couples contracted the virus possibly through sexual or close contact. Among infected couples, immune escape mutations were observed. A high prevalence of OBIs was found among the partners of chronically infected HBV blood donors, posing a potential threat to blood safety.


Assuntos
Hepatite B Crônica , Hepatite B , Humanos , Vírus da Hepatite B/genética , Antígenos de Superfície da Hepatite B , Segurança do Sangue , Doadores de Sangue , Prevalência , DNA Viral/genética , Hepatite B Crônica/epidemiologia , Anticorpos Anti-Hepatite B
19.
Transfus Clin Biol ; 30(4): 417-420, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37544584

RESUMO

BACKGROUND: The risk of transfusion-transmissible infections (TTIs) remains a concern in transfusion medicine. Since the rate of infection among first-time blood donors is higher than repeated donors, strategies to enhance blood safety can focus on new donors. The aim of the study was to investigate the effect of pre-donation viral screening of new donors on blood safety. METHODS AND MATERIALS: The pre-donation screening of new donors was implemented in the Kurdistan blood center. In this program, new donors who met the blood donation criteria were informed about the program and only a blood sample was donated for HBs Ag, HCV Ab, and HIV Ab testing. New donors with negative results were invited to donate blood after 12 weeks. A unit of blood was collected from eligible returned donors. Laboratory tests were performed again using the same methods. Finally, the prevalence of confirmed positive TTI results among donated blood in Kurdistan blood center was compared before and after the establishment of program. RESULTS: During the study, 4,434 new donors were screened for viral markers. A total of 41 new donors (0.92%, 95% CI, 0.007-0.13) had repeatedly reactive results and infection was confirmed in blood sample of 24 donors (0.54%, 95% CI, 0.003-0.008). Overall, 56% of new donors returned for blood donation. Prevalence of confirmed TTIs markers in collected blood units was 0.27% and 0 before and after implementing program, respectively. CONCLUSIONS: This study indicated that Pre-donation screening can reduce the risk of TTI transmission by identifying infected donors at the pre-donation phase.


Assuntos
Infecções por HIV , Reação Transfusional , Humanos , Segurança do Sangue , Doadores de Sangue , Reação Transfusional/epidemiologia , Reação Transfusional/prevenção & controle , Transfusão de Sangue , Bancos de Sangue , Infecções por HIV/epidemiologia , Prevalência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...