1.
Sci Rep ; 13(1): 9457, 2023 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-37301935

RESUMO

The ship floating raft system adopts the integrated design of large liquid tanks and rafts, which can optimize the arrangement in the cabin and increase the intermediate mass of the system to achieve efficient vibration isolation of equipment. One of the major challenges is that the change of liquid mass in the tank will cause displacement of the raft, which will change the modal characteristics of the system and affect the stability of the vibration isolation system performance. This paper establishes a mechanical analysis model of a floating raft system under time-varying liquid mass conditions. Taking a ship variable mass floating raft system as the research object, the effect of mass change on the characteristics of raft displacement, isolator load distribution, and modal frequency of the vibration isolation system is analyzed. The analysis shows that when the liquid tank goes from full load to no-load state, its mass change accounts for 40% of the total mass of the raft, which will cause a large displacement of the raft and change the low order modal frequency of the system, bringing the risk of equipment safety and vibration isolation performance degradation. Therefore, an adaptive variable load control method is proposed to realize the raft attitude balance and load equalization optimization under the variable mass condition of the floating raft air spring system. The test results show that the proposed control method can automatically adapt to the large mass gradual change from full load to no load of the liquid tank on the raft, and control the displacement of the raft structure from about 10 mm to 1.5 mm, which effectively ensures the stability of the air spring system performance.


Assuntos
Fenômenos Mecânicos , Navios , Pesos e Medidas
2.
Schizophr Bull ; 48(2): 425-436, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34915570

RESUMO

BACKGROUND: Digital phenotyping has been proposed as a novel assessment tool for clinical trials targeting negative symptoms in psychotic disorders (PDs). However, it is unclear which digital phenotyping measurements are most appropriate for this purpose. AIMS: Machine learning was used to address this gap in the literature and determine whether: (1) diagnostic status could be classified from digital phenotyping measures relevant to negative symptoms and (2) the 5 negative symptom domains (anhedonia, avolition, asociality, alogia, and blunted affect) were differentially classified by active and passive digital phenotyping variables. METHODS: Participants included 52 outpatients with a PD and 55 healthy controls (CN) who completed 6 days of active (ecological momentary assessment surveys) and passive (geolocation, accelerometry) digital phenotyping data along with clinical ratings of negative symptoms. RESULTS: Machine learning algorithms classifying the presence of a PD diagnosis yielded 80% accuracy for cross-validation in H2O AutoML and 79% test accuracy in the Recursive Feature Elimination with Cross Validation feature selection model. Models classifying the presence vs absence of clinically significant elevations on each of the 5 negative symptom domains ranged in test accuracy from 73% to 91%. A few active and passive features were highly predictive of all 5 negative symptom domains; however, there were also unique predictors for each domain. CONCLUSIONS: These findings suggest that negative symptoms can be modeled from digital phenotyping data recorded in situ. Implications for selecting the most appropriate digital phenotyping variables for use as outcome measures in clinical trials targeting negative symptoms are discussed.


Assuntos
Aprendizado de Máquina/tendências , Fenótipo , Transtornos Psicóticos/terapia , Pesos e Medidas/instrumentação , Adulto , Feminino , Humanos , Aprendizado de Máquina/normas , Masculino , Pessoa de Meia-Idade , Transtornos Psicóticos/psicologia , Pesos e Medidas/normas
3.
J Hepatol ; 76(2): 458-463, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34606912

RESUMO

Clinical and experimental advances related to the detection, magnitude and pathobiology of subclinical portal hypertension in non-alcoholic fatty liver disease (NAFLD), primarily observed in the presence of non-alcoholic steatohepatitis (NASH), prompt us to revisit current disease paradigms. Hepatic venous pressure gradient (HVPG) has been reported to underestimate portal pressure in NASH-related cirrhosis, while inaccuracy is more likely in non-cirrhotic livers, indicating a potential need for new and preferably non-invasive methods of measurement. Although clinically significant portal hypertension (HVPG ≥10 mmHg) retains its prognostic significance in NASH, subclinical portal hypertension (HVPG 6.0-9.5 mmHg) has been repeatedly detected in patients with NAFLD in the absence of cirrhosis or even significant fibrosis whereas the impact of these findings on disease outcomes remains unclear. Mechanocrine signalling pathways in various types of liver cell reveal a molecular basis for the adverse effects of subclinical portal hypertension and suggest a bidirectional relationship between portal pressure and fibrosis. These findings may guide efforts to improve risk assessment and identify novel therapeutic targets in NAFLD.


Assuntos
Hipertensão Portal/diagnóstico , Hepatopatia Gordurosa não Alcoólica/complicações , Pesos e Medidas/instrumentação , Humanos , Hipertensão Portal/fisiopatologia , Hepatopatia Gordurosa não Alcoólica/fisiopatologia , Prognóstico , Índice de Gravidade de Doença , Pesos e Medidas/normas
4.
Coron Artery Dis ; 31(1): 25-30, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34010182

RESUMO

OBJECTIVES: To assess the diagnostic performance of computed tomography angiography (CTA) and intravascular ultrasound (IVUS) derived minimum lumen areas (MLA) from the same lesions that correspond to an FFR ≤0.80. METHODS AND RESULTS: A total of 24 patients (33 arteries) were collected retrospectively according to the following inclusion criteria: presence of a CTA diagnostic followed by an IVUS and FFR percutaneous coronary procedures. CTA and IVUS lumen contours were automatically performed using previously validated methods.The correlation between CTA and IVUS for the MLA was r = 0.45. In terms of MLA, the mean difference between CTA and IVUS was 0.81 mm2. Of note, a much smaller CTA-derived MLA (2.10 mm2) was found to be related to significant FFR lesions compared to that of the MLA derived from IVUS (3.19 mm2). The area under the curve, accuracy, sensitivity and specificity for this CTA-derived MLA were 0.80, 0.76, 0.50 and 0.87, respectively, while these values for IVUS-derived MLA were 0.87, 0.85, 0.80 and 0.87. CONCLUSIONS: Computed tomography angiography and intravascular ultrasound-derived minimum lumen areas have moderate diagnostic efficiency, albeit slightly better for IVUS, in identifying hemodynamically severe coronary stenoses. The utility of MLA, automatically derived from either CTA or IVUS as an alternative to FFR to guide the decision to revascularize, should be tested clinically.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Ultrassonografia de Intervenção/métodos , Pesos e Medidas/normas , Idoso , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Estenose Coronária/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Ultrassonografia de Intervenção/estatística & dados numéricos , Pesos e Medidas/instrumentação
5.
Prenat Diagn ; 41(13): 1658-1667, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34647342

RESUMO

OBJECTIVE: To create nomograms for fetal cardiothoracic (CT) ratio as assessed by three different 2-dimensional sonographic measurements, including CT diameter, circumference, and area ratios, in Thai fetuses with a gestational age (GA) of 17-37 weeks, and to evaluate both their correlation with GA or biparietal diameter (BPD) and variability among the three measurement methods. METHODS: Two-dimensional sonographic measurements of fetal CT ratio in 4-chamber view were assessed by three different measurement techniques. The 95% reference intervals and Z-scores of all measurement methods based on GA or BPD were constructed. Intraclass correlation coefficients (ICC) for the reproducibility of each technique were compared. RESULTS: A total of 511 uncomplicated singleton pregnancies were included. The fetal CT ratio values by all measurement techniques gradually and smoothly increased with increasing GA and BPD. The fetal CT circumference ratio showed the least correlation with both GA and BPD. The intraobserver and interobserver reliability coefficients of all techniques demonstrated almost excellent agreement (all ICCs at least 0.87). CONCLUSION: Reference intervals and Z-score reference ranges were developed using three different techniques for fetal CT ratio with a GA of 17-37 weeks. These nomograms are a simple and reliable screening tool for identifying abnormal fetal heart size.


Assuntos
Coração Fetal/diagnóstico por imagem , Idade Gestacional , Nomogramas , Pesos e Medidas/normas , Adulto , Feminino , Coração Fetal/fisiopatologia , Humanos , Gravidez , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal/métodos , Ultrassonografia Pré-Natal/estatística & dados numéricos , Pesos e Medidas/instrumentação
6.
Medicine (Baltimore) ; 100(37): e27255, 2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34664873

RESUMO

ABSTRACT: This study was performed to determine whether red blood cell distribution width (RDW) is associated with 3-month poor functional outcome in patients undergoing thrombolytic therapy for acute ischemic stroke.RDW was measured in patients with thrombolytic therapy in emergency department. Functional outcome was assessed after 3 months and poor functional outcome was defined as modified Rankin scale 3 to 6.A total of 240 patients were enrolled, and 82 (34.2%) had a poor functional outcome. The median RDW was significantly elevated in patients with a poor functional outcome compare with those with a good outcome. RDW was independently associated with a 3-month poor functional outcome (odds ratio 3.369, 95% confidence interval 2.214-5.125). The optimal RDW cutoff for predicting 3-month poor functional outcome was 12.8%, and the area under the curve for RDW was 0.818 (95% confidence interval 0.761-0.876). The area under the curve for RDW was higher in male patients than in female patients. The RDW correlated positively with the modified Rankin scale score after 3 months and the initial National Institutes of Health Stroke Scale score.Initial higher RDW level is related to a 3-month poor functional outcome in patients undergoing thrombolytic therapy for acute ischemic stroke.


Assuntos
Eritrócitos/classificação , AVC Isquêmico/complicações , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Terapia Trombolítica/normas , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Feminino , Humanos , AVC Isquêmico/epidemiologia , AVC Isquêmico/mortalidade , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Avaliação de Resultados em Cuidados de Saúde/métodos , Prognóstico , Curva ROC , Estudos Retrospectivos , Seul/epidemiologia , Estatísticas não Paramétricas , Terapia Trombolítica/métodos , Terapia Trombolítica/estatística & dados numéricos , Pesos e Medidas/instrumentação
7.
Adv Skin Wound Care ; 34(9): 1-6, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34415258

RESUMO

OBJECTIVE: To investigate the evolution of pressure-measuring devices used in compression treatment for venous leg ulcers and assess the most practical and effective devices to determine optimal pressure in compression therapy. DATA SOURCES: Relevant information was retrieved from databases including Google Scholar, PubMed, Wiley Online, and ScienceDirect without publication date restrictions. The keywords included venous leg ulcer, compression therapy, pressure measuring device, pressure sensor, and wireless system. STUDY SELECTION: Studies included in the review had to be published in English and discuss or compare pressure-measuring devices/sensors for compression therapy, the development of alternative sensors, and the applications of wireless technologies. Veterinary studies, conference proceedings, and unpublished articles were excluded. Applicable studies and articles were critically evaluated and synthesized. DATA EXTRACTION: After abstract review, 39 studies were identified. During full-text review, study details were collected using a data extraction form and organized into tables. Device attributes, accuracy, price, and limitations were categorized and analyzed. DATA SYNTHESIS: Studies disagree on the effectiveness and user-friendliness of existing pressure-measuring devices. These devices often impact user comfort and convenience, which are crucial factors in the adoption and use of wearable devices. Potential solutions for pressure-measuring devices with promising technologies were proposed: four feasible alternative sensors are described that could improve comfort and facilitate prolonged use under bandages. Advanced communication technologies may provide more convenience for users and practitioners. CONCLUSIONS: Conventional pressure-measuring devices used in compression therapy are not designed for the user's comfort and convenience. The use of flexible and stretchy pressure sensors (e-skin) provides good biocompatibility, conformability, and comfort and when integrated with near-field communication technology could address the drawbacks of current pressure-measuring devices.


Assuntos
Bandagens Compressivas/normas , Úlcera da Perna/terapia , Pesos e Medidas/instrumentação , Bandagens Compressivas/estatística & dados numéricos , Equipamentos e Provisões/normas , Humanos , Pressão/efeitos adversos
8.
Medicine (Baltimore) ; 100(33): e26988, 2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34414978

RESUMO

ABSTRACT: With the declining use of the pulmonary artery catheter (PAC), transesophageal echocardiography (TEE) has become an appealing alternative to obtain pulmonary artery pressure non-invasively using the simplified Bernoulli equation. The validation of this method in the perioperative setting has been scarce with no clear recommendations about which view is the most accurate to estimate right ventricular systolic pressure (RVSP).Therefore, we performed a prospective, observer-blinded, diagnostic test accuracy study to assess the difference in systolic pulmonary artery pressure (sysPAP) measuring both, invasively sysPAP and estimated RVSP with TEE in 3 different views: the mid-esophageal (ME) 4Chamber, the ME right ventricular (RV) inflow-outflow and the ME modified bicaval view.To show a clinically significant difference of at least 10% in RVSP, we included 40 cardiac surgical patients divided into 3 subgroups: Patients with mild to moderate tricuspid regurgitation (TR) and mean PAP <25 mm Hg, patients with mild to moderate TR and mean PAP≥ 25 mm Hg, and patients with severe TR.For the whole cohort, bias of estimated RVSP compared to measured sysPAP was 5.27 mm Hg, precision was 7.96 mm Hg, limits of agreement were -10.66 to 21.19 mm Hg. The best agreement between the 2 methods was found in patients with severe TR and in the ME RV inflow-outflow and the modified bicaval view. Good Doppler signals were available in 35% and 46% in these views, and in 20% in the ME 4 chamber view.The estimation of the sysPAP by TEE cannot be considered reliable in the clinical perioperative setting. Only measurements that provide a full Doppler envelope show sufficient precision to provide accurate estimations.


Assuntos
Ecocardiografia Transesofagiana/métodos , Hipertensão Arterial Pulmonar/classificação , Pesos e Medidas/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea/fisiologia , Ecocardiografia Transesofagiana/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Pesos e Medidas/instrumentação
9.
Medicine (Baltimore) ; 100(33): e26998, 2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34414985

RESUMO

BACKGROUND: Early diagnosis as well as treatment is important in management of congenital muscular torticollis (CMT). The purpose of this study was to find an effective physical therapy modality to improve the sternocleidomastoid (SCM) muscle thickness, the ratio of the SCM muscle thickness on the affected side to that on the non-affected side (A/N ratio), and head rotation in infant under 3 months of age diagnosed with CMT. METHODS AND ANALYSIS: A single-blind, randomized clinical trial was conducted. Participants were assigned in one of the 3 study groups through randomization. The treatment was performed 3 times a week for 30 minutes until the head tilt was ≤5 degrees. Group 1 was treated by handling for active or active-assist movement, group 2 was treated with passive stretching, and group 3 was treated with thermotherapy. For general characteristics, a χ2 test and 1-way analysis of variance were used. Intragroup differences were analyzed using a paired t test, and intergroup differences were analyzed using an age-adjusted analysis of covariance. RESULTS: After the intervention, there was no significant difference between groups in terms of SCM thickness on the affected side and A/N ratio (P > .05). Degree of head rotation on the affected side showed significant differences between groups (P < .05), with Group 2 showing significantly better results than group 1 and group 3 (P < .05, both). CONCLUSION: Passive stretching treatment was more effective than other treatments of this study for improvement in degree of head rotation in CMT infants under 3 months of age. TRIAL REGISTRATION: The trial is registered at the Institutional Review Board of Sahmyook University (IRB number, 2-7001793-AB-N-012019103HR) and the Clinical Research Information Service (CRiS; registry number, KCT0004862).


Assuntos
Músculos/fisiopatologia , Modalidades de Fisioterapia/normas , Esterno/fisiopatologia , Torcicolo/congênito , Pesos e Medidas/normas , Humanos , Lactente , Modalidades de Fisioterapia/estatística & dados numéricos , Método Simples-Cego , Torcicolo/complicações , Torcicolo/terapia , Pesos e Medidas/instrumentação
10.
Nutr Hosp ; 38(5): 1009-1015, 2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34223769

RESUMO

INTRODUCTION: Introduction: some factors have been shown to be associated with survival in patients with pancreatic adenocarcinoma. Recently, some studies suggested that malnutrition, muscle mass, and inflammation might have an effect on survival in patients with pancreatic malignancy. Objectives: to investigate the association between psoas muscle mass, inflammation, nutritional status at the time of diagnosis, and survival in patients with pancreatic adenocarcinoma. Methods: this retrospective study included 219 patients diagnosed with pancreatic carcinoma. The nutritional status, inflammation, and psoas muscle mass of the patients at the time of diagnosis were evaluated. Nutritional status was assessed using the Prognostic Nutritional Index (PNI). Leucocyte count and neutrophil/lymphocyte ratio (NLR) were used for inflammation assessment. Psoas muscle mass was calculated by using abdominal computed tomography images of the patients. Results: the mean age of patients (80 female and 139 male) was 66.6 ± 11.7 years. According to the PNI results, 155 patients had a normal nutritional status (70 %), whereas 64 patients were malnourished (30 %). The survival of the patients with normal nutritional status was significantly longer than that of those who were malnourished (p < 0.001). There was no significant relationship between psoas muscle area, leucocyte count, NLR, and survival time. Conclusion: the survival of pancreatic adenocarcinoma patients with malnutrition at the time of diagnosis was significantly shorter than for patients without malnutrition.


INTRODUCCIÓN: Introducción: se ha demostrado que algunos factores se asocian a la supervivencia en los pacientes con adenocarcinoma de páncreas. Recientemente, algunos estudios sugirieron que la desnutrición, la masa muscular y la inflamación podrían afectar a la supervivencia de los pacientes con neoplasias malignas pancreáticas. Objetivo: investigar la asociación entre masa muscular del psoas, inflamación, estado nutricional en el momento del diagnóstico y supervivencia en pacientes con adenocarcinoma de páncreas. Métodos: este estudio retrospectivo incluyó a 219 pacientes diagnosticados de carcinoma de páncreas. Se evaluaron el estado nutricional, la inflamación y la masa del músculo psoas de los pacientes en el momento del diagnóstico. El estado nutricional de los pacientes se evaluó con el Índice Nutricional Pronóstico (PNI). El recuento de leucocitos y el cociente de neutrófilos/linfocitos (NLR) se emplearon para la evaluación de la inflamación. La masa del músculo psoas se calculó utilizando las imágenes de tomografía computarizada abdominal de los pacientes. Resultados: la edad media de los pacientes (80 mujeres y 139 hombres) fue de 66,6 ± 11,7 años. Según los resultados del PNI, 155 pacientes tenían un estado nutricional normal (70 %) mientras que 64 pacientes estaban desnutridos (30 %). La supervivencia de los pacientes con estado nutricional normal fue significativamente mayor que la de los pacientes desnutridos (p < 0,001). No hubo ninguna relación significativa entre el área del músculo psoas, el recuento de leucocitos, el NLR y el tiempo de supervivencia. Conclusión: la supervivencia de los pacientes con adenocarcinoma de páncreas con desnutrición en el momento del diagnóstico fue significativamente menor que la de los pacientes sin desnutrición.


Assuntos
Adenoma/complicações , Inflamação/etiologia , Estado Nutricional/fisiologia , Neoplasias Pancreáticas/complicações , Músculos Psoas , Adenoma/fisiopatologia , Idoso , Feminino , Humanos , Inflamação/fisiopatologia , Masculino , Pessoa de Meia-Idade , Avaliação Nutricional , Neoplasias Pancreáticas/fisiopatologia , Prognóstico , Estudos Retrospectivos , Pesos e Medidas/instrumentação
11.
Mol Biol Rep ; 48(5): 4591-4600, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34125331

RESUMO

Our previous study showed that soy milks could contain high levels of active soybean trypsin inhibitors (SBTI) if they were not properly processed. This study investigated the effects of consuming active SBTI on pancreatic weights, histology, trypsinogen production and expression of STAT3, receptors for androgen (AR) and estrogen (ER) in pancreas, liver and uterus of rats. Weanling Sprague-Dawley rats were randomly divided into 3 groups (8 females and 8 males/group) and fed diets containing either 20% casein protein (Casein) or 20% soy protein (SP) in the presence of high (1.42 BAEE unit/µg, SP + SBTI) or low (0.2 BAEE unit/µg, SP-SBTI) levels of active SBTI for 8 weeks. Ingestion of SP + SBTI diet markedly increased pancreatic weights and trypsinogen content (p < 0.01), and caused acinar cell hypertrophy, and reduced pancreatic STAT3, p-STAT3, AR and ERß content, and increased uterine ERα and ERß compared to the Casein or SP-SBTI diets (p < 0.05). The two SP-containing diets lowered hepatic STAT3, p-STAT3, and pancreatic ERα, and increased hepatic ERα and ERß content in the female rats compared to the Casein diet (p < 0.05). This study demonstrated for the first time that consumption of high level of active SBTI not only increased pancreatic weights and acinar cell secretions, but also attenuated the expression of pancreatic STAT3, p-STAT3, AR, and ERß proteins in both sexes and increased uterine ERα and ERß content, and that dietary soy protein affected hepatic STAT3, p-STAT3, ERα and ERß in a gender-dependent manner.


Assuntos
Receptor alfa de Estrogênio/genética , Receptor beta de Estrogênio/genética , Pâncreas/metabolismo , Fator de Transcrição STAT3/genética , Inibidores da Tripsina/farmacologia , Animais , Estrogênios/genética , Feminino , Regulação da Expressão Gênica/efeitos dos fármacos , Fígado , Masculino , Pâncreas/efeitos dos fármacos , Ratos , Receptores Androgênicos/genética , Proteínas de Soja/genética , Proteínas de Soja/farmacologia , Distribuição Tecidual/efeitos dos fármacos , Distribuição Tecidual/genética , Pesos e Medidas/normas
12.
BMC Pregnancy Childbirth ; 21(1): 446, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-34172024

RESUMO

BACKGROUND: Twin birth weight percentiles are less popular in clinical management among twin pregnancies compared with singleton ones in China. This study aimed to compare the incidence and neonatal outcomes of small for gestational age (SGA) twins between the use of singleton and twin birth weight percentiles. METHODS: This was a retrospective cohort study of 3,027 pregnancies with liveborn twin pairs at gestational age of > 28 weeks. The newborns were categorized as SGA when a birthweight was less than the 10th percentile based on the singleton and twin references derived from Chinese population. Logistic regression models with generalized estimated equation (GEE) were utilized to evaluate the association between SGA twins and neonatal outcomes including neonatal unit admission, neonatal jaundice, neonatal respiratory distress (NRDS), neonatal asphyxia, ventilator support, hypoxic ischemic encephalopathy (HIE), bronchopulmonary dysplasia (BPD), necrotizing enterocolitis (NEC), intracranial hemorrhage (ICH), culture-proven sepsis, neonatal death within 28 days after birth as well as the composite outcome. RESULTS: The incidence of SGA was 33.1 % based on the singleton reference and 7.3 % based on the twin reference. Both of SGA newborns defined by the singleton and twin references were associated with increases in neonatal unit admission, neonatal jaundice and ventilator support. In addition, SGA newborns defined by the twin reference were associated with increased rates of BPD (aOR, 2.61; 95 % CI: 1.18-5.78) as well as the severe composite outcome (aOR, 1.93; 95 % CI: 1.07-3.47). CONCLUSIONS: The use of singleton birth weight percentiles may result in misdiagnosed SGA newborns in twin gestations and the twin birth weight percentiles would be more useful to identify those who are at risk of adverse outcomes.


Assuntos
Peso ao Nascer , Recém-Nascido Pequeno para a Idade Gestacional , Gêmeos/estatística & dados numéricos , Pesos e Medidas/normas , China/epidemiologia , Doenças em Gêmeos/epidemiologia , Feminino , Idade Gestacional , Humanos , Incidência , Recém-Nascido , Doenças do Recém-Nascido/epidemiologia , Modelos Logísticos , Masculino , Gravidez , Gravidez de Gêmeos , Padrões de Referência , Estudos Retrospectivos
13.
Int J Obes (Lond) ; 45(9): 2108-2117, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34172828

RESUMO

OBJECTIVE: Cell diameter, area, and volume are established quantitative measures of adipocyte size. However, these different adipocyte sizing parameters have not yet been directly compared regarding their distributions. Therefore, the study aimed to investigate how these adipocyte size measures differ in their distribution and assessed their correlation with anthropometry and laboratory chemistry. In addition, we were interested to investigate the relationship between fat cell size and adipocyte mitochondrial respiratory chain capacity. METHODS: Subcutaneous and visceral histology-based adipocyte size estimates from 188 individuals were analyzed by applying a panel of parameters to describe the underlying cell population. Histology-based adipocyte diameter distributions were compared with adipocyte diameter distributions from collagenase digestion. Associations of mean adipocyte size with body mass index (BMI), glucose, HbA1C, blood lipids as well as mature adipocyte mitochondrial respiration were investigated. RESULTS: All adipocyte area estimates derived from adipose tissue histology were not normally distributed, but rather characterized by positive skewness. The shape of the size distribution depends on the adipocyte sizing parameter and on the method used to determine adipocyte size. Despite different distribution shapes histology-derived adipocyte area, diameter, volume, and surface area consistently showed positive correlations with BMI. Furthermore, associations between adipocyte sizing parameters and glucose, HbA1C, or HDL specifically in the visceral adipose depot were revealed. Increasing subcutaneous adipocyte diameter was negatively correlated with adipocyte mitochondrial respiration. CONCLUSIONS: Despite different underlying size distributions, the correlation with obesity-related traits was consistent across adipocyte sizing parameters. Decreased mitochondrial respiratory capacity with increasing subcutaneous adipocyte diameter could display a novel link between adipocyte hypertrophy and adipose tissue function.


Assuntos
Adipócitos/classificação , Obesidade/fisiopatologia , Pesos e Medidas/normas , Adipócitos/fisiologia , Tecido Adiposo/metabolismo , Adulto , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mitocôndrias/fisiologia , Pesos e Medidas/instrumentação
14.
Crit Care ; 25(1): 196, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-34099028

RESUMO

BACKGROUND: The evaluation of patient effort is pivotal during pressure support ventilation, but a non-invasive, continuous, quantitative method to assess patient inspiratory effort is still lacking. We hypothesized that the concavity of the inspiratory flow-time waveform could be useful to estimate patient's inspiratory effort. The purpose of this study was to assess whether the shape of the inspiratory flow, as quantified by a numeric indicator, could be associated with inspiratory effort during pressure support ventilation. METHODS: Twenty-four patients in pressure support ventilation were enrolled. A mathematical relationship describing the decay pattern of the inspiratory flow profile was developed. The parameter hypothesized to estimate effort was named Flow Index. Esophageal pressure, airway pressure, airflow, and volume waveforms were recorded at three support levels (maximum, minimum and baseline). The association between Flow Index and reference measures of patient effort (pressure time product and pressure generated by respiratory muscles) was evaluated using linear mixed effects models adjusted for tidal volume, respiratory rate and respiratory rate/tidal volume. RESULTS: Flow Index was different at the three pressure support levels and all group comparisons were statistically significant. In all tested models, Flow Index was independently associated with patient effort (p < 0.001). Flow Index prediction of inspiratory effort agreed with esophageal pressure-based methods. CONCLUSIONS: Flow Index is associated with patient inspiratory effort during pressure support ventilation, and may provide potentially useful information for setting inspiratory support and monitoring patient-ventilator interactions.


Assuntos
Capacidade Inspiratória , Respiração Artificial/instrumentação , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Unidades de Terapia Intensiva/organização & administração , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Respiração Artificial/métodos , Respiração Artificial/estatística & dados numéricos , Mecânica Respiratória/fisiologia , Pesos e Medidas/instrumentação
15.
Medicine (Baltimore) ; 100(23): e26183, 2021 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-34115001

RESUMO

BACKGROUND: With high diagnostic accuracy, magnetic resonance elastography (MRE) is a noninvasive tool and can be adopted to measure liver stiffness (LS). In this study, meta-analysis was carried out to further evaluate whether LS measured by MRE can predict early recurrence in patients with hepatocellular carcinoma (HCC). METHODS: PUBMED, EMBASE, Web of Science, China National Knowledge Infrastructure, and Cochrane Library database were searched for studies related to LS measured by MRE in the prediction of recurrence in patients with HCC. Survival outcome was estimated by hazard ratios and 95% confidence intervals. Meta-analysis was conducted with the Stata 16.0. RESULTS: The results of this meta-analysis will be submitted to a peer-reviewed journal for publication. CONCLUSION: This study will provide evidence support for LS measured by MRE in predicting the recurrence of HCC. ETHICS AND DISSEMINATION: The private information from individuals will not be published. This systematic review also should not damage participants' rights. Ethical approval is not available. The results may be published in a peer-reviewed journal or disseminated in relevant conferences. OSF REGISTRATION NUMBER: DOI 10.17605/ OSF.IO / SURH3.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Protocolos Clínicos , Técnicas de Imagem por Elasticidade/normas , Fígado/fisiopatologia , Carcinoma Hepatocelular/classificação , Técnicas de Imagem por Elasticidade/instrumentação , Técnicas de Imagem por Elasticidade/métodos , Humanos , Fígado/diagnóstico por imagem , Metanálise como Assunto , Modelos de Riscos Proporcionais , Recidiva , Revisões Sistemáticas como Assunto , Pesos e Medidas/instrumentação , Pesos e Medidas/normas
16.
Nutr Hosp ; 38(4): 729-735, 2021 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-34110225

RESUMO

INTRODUCTION: Introduction: functional limitation is a result of sarcopenia and is associated with loss of skeletal muscle mass (SMM). Cost-effective methods are important for the identification of sarcopenia. Objective: to propose cutoff points for normalized calf circumference (CC) in order to identify low SMM in older women based on their functional limitation. Methods: in this descriptive, cross-sectional study the CC values of a young female sample (n = 78) were used to establish cutoff points (-2 SD) for low SMM in older women (n = 67). Functional limitation was identified by the six-minute walk test (≤ 400 m). CC was normalized by body mass, height, and BMI. The diagnostic accuracy of CC was calculated with a ROC curve, using functional limitation as standard. Results: cutoff points and area under the curve (AUC) were: CC (≤ 28.5; 0.62); CC·body mass-1 (≤ 0.40; 0.63); CC·height-2 (≤ 8.52; 0.55) and CC·BMI-1 (≤ 1.10; 0.73). Only CC·BMI-1 achieved a desirable accuracy (AUC > 0.7) to distinguish functional limitation. Conclusion: the accuracy attained supports the use of CC·BMI-1 to identify low SMM in older women. In the clinical context it is possible to predict the risk of sarcopenia when sophisticated methods for determining SMM are not available.


INTRODUCCIÓN: Introducción: la limitación funcional es consecuencia de la sarcopenia y se asocia con la pérdida de masa muscular esquelética (MME). Los métodos rentables son importantes para la identificación de la sarcopenia. Objetivo: proponer puntos de corte para la circunferencia de la pantorrilla (CP), normalizada para identificar un MME bajo en mujeres mayores en función de su limitación funcional. Métodos: en este estudio descriptivo de carácter transversal se utilizaron los valores de CP de una muestra de mujeres jóvenes (n = 78) para establecer los puntos de corte (-2 DS) de la MME baja en las mujeres mayores (n = 67). La limitación funcional se identificó mediante la prueba de la marcha de seis minutos (≤ 400 m). La CP se normalizó por la masa corporal, la altura y el IMC. La precisión diagnóstica de la CP se calculó con la curva ROC, utilizando como estándar la limitación funcional. Resultados: los puntos de corte y el área bajo la curva (AUC) fueron: CP (≤ 28,5; 0,62); CP·masa corporal-1 (≤ 0,40; 0,63); CP·altura-2 (≤ 8,52; 0,55) y CP·IMC-1 (≤ 1,10; 0,73). Solo el CP·IMC-1 logró la precisión deseable (AUC > 0,7) para distinguir la limitación funcional. Conclusión: la precisión alcanzada respalda el uso de CP·IMC-1 para identificar la MME baja en las mujeres mayores. En el contexto clínico es posible predecir el riesgo de sarcopenia cuando no se dispone de métodos sofisticados para determinar la MME.


Assuntos
Extremidade Inferior/fisiopatologia , Músculo Esquelético/fisiologia , Medição de Risco/normas , Idoso , Idoso de 80 Anos ou mais , Antropometria/métodos , Área Sob a Curva , Índice de Massa Corporal , Estudos Transversais , Feminino , Humanos , Extremidade Inferior/fisiologia , Músculo Esquelético/anormalidades , Músculo Esquelético/fisiopatologia , Curva ROC , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Sarcopenia/diagnóstico , Sarcopenia/fisiopatologia , Pesos e Medidas/instrumentação
17.
Nutr Hosp ; 38(4): 704-709, 2021 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-34024110

RESUMO

INTRODUCTION: Background: an association between low 25(OH)D levels and blood lipids has been identified in children, adolescents, and adults but not in the early stages of life, and a relation to carotid and aortic intima-media thickness has not been well studied and is controversial. Objective: to identify whether 25(OH)D levels are correlated with blood lipids and aortic and carotid intima-media thickness in infants aged 3 to 9 months. Methods: a cross-sectional study was conducted in 109 healthy term infants between the ages of 3 and 9 months. Serum vitamin D [25(OH)D], total cholesterol, HDL-cholesterol, non-HDL-cholesterol, and aortic and carotid intima-media thickness were measured. Feeding method, vitamin D supplementation, and sun exposure habits were recorded. Results: only 2.8 % (n = 3) and 10.1 % (n = 14) had vitamin D deficiency and insufficiency, respectively. Infants with inadequate levels of vitamin D were younger (< 6 months) (p = 0.004), and a lower percentage of their body surface area was exposed to the sun (p = 0.006). A significant positive correlation was found between 25(OH)D levels and non-HDL-cholesterol in the infants that consumed breastmilk substitutes (rho = 0.600, p < 0.001) or were partially breastfed (rho = 0.371, p = 0.026), whereas a positive correlation was found with total cholesterol in the infants receiving breastmilk substitutes (rho = 0.618, p < 0.001). No significant correlation was found between vitamin D and aortic or carotid intima-media thickness. Conclusions: there was a positive correlation between 25(OH)D levels and both total and non-HDL-cholesterol only in infants receiving breastmilk substitutes. The frequency of vitamin D deficiency and insufficiency was low.


INTRODUCCIÓN: Introducción: se ha identificado una asociación entre los niveles de 25(OH)D y de lípidos en sangre en los niños, adolescentes y adultos, pero no en las primeras etapas de la vida, mientras que la asociación con el grosor de la íntima-media aórtica (a-IMT) o carotídea (c-IMT) no se ha estudiado totalmente y es objeto de controversia. Objetivo: identificar si existe correlación entre los niveles de 25(OH)D y de lípidos en sangre y el a-IMT y c-IMT en lactantes de 3 a 9 meses. Métodos: se realizó un estudio transversal en 109 lactantes sanos de entre 3 y 9 meses de edad; se midieron la vitamina D sérica [25(OH)D], el colesterol total, el colesterol HDL, el colesterol no HDL, el a-IMT y el c-IMT. Se registraron el tipo de alimentación, la suplementación con vitamina D y la exposición solar. Resultados: aquellos con niveles inadecuados de vitamina D fueron los menores de 6 meses (p = 0,004) y los expuestos en un menor porcentaje de su cuerpo al sol (p = 0,006). Se encontró una correlación positiva significativa entre la 25(OH)D, el colesterol total (rho = 0,618, p < 0,001) y el colesterol no HDL (rho = 0,600, p < 0.001) en aquellos que consumían sustitutos de la leche materna. No se encontró correlación entre la vitamina D y el grosor de la íntima-media aórtica o carotídea. Solo el 2,8 % y el 10,1 % presentaron deficiencia e insuficiencia de vitamina D, respectivamente. Conclusiones: se encontró una correlación positiva entre los niveles de 25(OH)D, colesterol total y colesterol no HDL en los lactantes que recibían sustitutos de la leche materna.


Assuntos
Aorta/fisiologia , Espessura Intima-Media Carotídea/classificação , Lipídeos/análise , Vitamina D/análise , Estudos Transversais , Feminino , Humanos , Lactente , Lipídeos/sangue , Masculino , Fatores de Risco , Vitamina D/sangue , Pesos e Medidas/instrumentação
18.
Adv Skin Wound Care ; 34(6): 309-312, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33979819

RESUMO

OBJECTIVE: To evaluate the usability of a novel instrument (stoma ruler) to measure damaged peristomal skin in patients with an ostomy. METHODS: A wound ostomy and continence nurse used both the stoma ruler and a linear ruler to assess DET (discoloration, erosion, tissue overgrowth) scores and the height of protrusion above the skin of 10 patients with ileostomies and took photographs. The photographs were presented to five ostomy care nurses for reliability testing. The difference between the two methods was determined using paired Wilcoxon signed ranks test. PRIMARY OUTCOME MEASURE: Interrater reliability of the linear versus stoma ruler. RESULTS: The interrater reliabilities of the stoma ruler versus the linear ruler for the domain-area DET score were 0.95 (95% confidence interval, 0.89-0.99) and 0.68 (95% confidence interval, 0.42-0.89), respectively. Only nurse 5 reported a significant difference between the two rulers (z = -2.24, P = .03). CONCLUSIONS: In busy clinical settings, the stoma ruler is easy for ostomy care nurses to use to obtain accurate DET scores and the height of stoma protrusion above the skin. Observing the position of damaged skin using the clock marks on the stoma ruler enhance clinical description and reduce assessment variation among professionals.


Assuntos
Estomia/efeitos adversos , Higiene da Pele/instrumentação , Pesos e Medidas/instrumentação , Pesos e Medidas/normas , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estomia/métodos , Estomia/estatística & dados numéricos , Reprodutibilidade dos Testes , Higiene da Pele/estatística & dados numéricos
19.
Fam Syst Health ; 39(1): 29-37, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34014728

RESUMO

Shared decision making (SDM) has been gaining an increasing appeal in providing patient-centered health care, which focuses on patients' needs and values and their active role in making health-related decisions. However, SDM remains difficult to measure because different conceptual definitions have been used in the literature, resulting in different operational definitions and measurement approaches. In addition, traditional measurement approaches, such as self-reports, can fail to capture the dynamic nature of the SDM process. In this paper, we propose using sensor-based measurement (i.e., using sensors to collect objective and automated data in real time) to examine the SDM process to overcome the measurement challenges inherent in more traditional measurement approaches. We also call for further discussion on the role and feasibility of using sensors in studying SDM. Using a few sensors as an example, we discuss benefits and challenges of sensor-based measurement in this area. (PsycInfo Database Record (c) 2021 APA, all rights reserved).


Assuntos
Tomada de Decisão Compartilhada , Relações Profissional-Família , Humanos , Autorrelato , Pesos e Medidas/instrumentação
20.
PLoS One ; 16(4): e0250207, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33861774

RESUMO

Vertical tanks are commonly used appliances for liquids, and its capacity is very important for quantitative liquid ratio and liquid trade. In order to measure the capacity of vertical tanks more conveniently, this paper proposes a vertical tank capacity measurement method based on Monte Carlo Method. The method arranges a plurality of sensor points on the inner surface of the tank, and then performs Monte Carlo tests by generating a large number of random sample points, and finally calculates the capacity by counting the sample points that meet the criterion. The criterion for whether a sample point is located in the tank, which is the core issue, is established with the coordinates of sensor points and the distance between different sensor points along the surface of the tank. The results show that the absolute error of the measurement results of the proposed method does not exceed ±0.0003[m3], and the absolute error of capacity per unit volume has a linear relationship with the height of the vertical tank, and has little effect with the radial size of the vertical tank.


Assuntos
Previsões/métodos , Precisão da Medição Dimensional , Modelos Teóricos , Método de Monte Carlo , Pesos e Medidas