Environ Toxicol Pharmacol ; 110: 104499, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39019244

RESUMO

This study aimed to evaluate the environmental impact of dental materials: commercial composite Tetric EvoCeram®, glass ionomer Equia Forte® HT Fil, laboratory-prepared composite, alkasite Cention® Forte, amalgam Amalcap® Plus, and samples from dental chair drainage systems (DCDS). Methacrylate monomers were detected in the eluates of experimental and commercials composites, and alkasite. In DCDS samples solely mercury was found at concentrations of 0.08-1.86 µg/L. The experimental composite (48 h incubation) exhibited the highest toxicity on zebrafish Danio rerio (LC50=0.70 g/L), followed by amalgam (LC50=8.27 g/L) < Tetric EvoCeram® (LC50=10.94 g/L) < Equia Forte® HT Fil (LC50=24.84 g/L) < Cention® Forte (LC50=32.22 g/L). Exposure of zebrafish to DCDS samples resulted in decreased larval body length and increased occurrences of edema and blood accumulation. The results obtained highlight the need for additional monitoring and further research on the release of unreacted monomers and mercury from dental materials and their environmental impact.


Assuntos
Poluentes Químicos da Água , Peixe-Zebra , Animais , Poluentes Químicos da Água/toxicidade , Poluentes Químicos da Água/análise , Larva/efeitos dos fármacos , Mercúrio/toxicidade , Mercúrio/análise , Materiais Dentários/toxicidade , Resinas Compostas/toxicidade , Amálgama Dentário/toxicidade , Equipamentos Odontológicos
3.
Dent Med Probl ; 61(3): 391-399, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38963395

RESUMO

BACKGROUND: In Mexico and around the world, water in dental units, including triple syringes, comes from municipal chlorinated water mains. The microbial contamination of dental unit water systems constitutes a risk factor for opportunistic infections. OBJECTIVES: The present work aimed to identify the bacteria present in the triple-syringe water lines of dental units at a dental school of a public university in Mexico, with a hypothesis that opportunistic bacteria of importance to human health would be found. MATERIAL AND METHODS: A cross-sectional study was carried-out. A total of 100 samples of triple-syringe tubing from dental units operated by a dental school of a public university in Mexico were analyzed before and after their use in dental practice. Bacterial biofilm was cultured and isolated from the tubing, using standard microbiological methods, and then the species present were identified through 16S rRNA gene sequencing. The characterization of the biofilm was performed by means of scanning electron microscopy (SEM). RESULTS: Bacterial growth was observed in 20% of the non-disinfected and 10% of the disinfected samples, with 11 strains isolated. Six genera and 11 bacterial species were genetically identified. Coagulasenegative staphylococci (CoNS), considered opportunistic human pathogens, were among the most critical microorganisms. Scanning electron microscopy revealed a thick polymeric matrix with multiple bacterial aggregates. CONCLUSIONS: Opportunistic bacteria from human skin and mucous membranes were detected. Under normal conditions, these bacteria are incapable of causing disease, but are potentially harmful to immunosuppressed patients.


Assuntos
Biofilmes , Contaminação de Equipamentos , Seringas , Microbiologia da Água , Estudos Transversais , México , Humanos , Seringas/microbiologia , Equipamentos Odontológicos/microbiologia , Microscopia Eletrônica de Varredura , Bactérias/isolamento & purificação , Genótipo , RNA Ribossômico 16S
4.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 59(7): 647-652, 2024 Jul 09.
Artigo em Chinês | MEDLINE | ID: mdl-38949132

RESUMO

Dental turbine is a commonly used instrument for oral clinical treatment. However, there is usually suckback during the using of the traditional dental turbine, which causes the pathogen residue in the pipeline of the dental comprehensive treatment table, leading to cross-infection. Zero suckback technology is a new oral treatment technology to avoid suckback during the usage of dental turbine, which can reduce the possibility of cross infection. However, the applications and methods of zero suckback technique in oral therapy remain to be clarified. This consensus mainly provides guidance for the clinical standard application of zero suckback technology from following aspects: field and definition, indications, applicable population, personnel requirements, operating process and evaluation of therapeutic effect.


Assuntos
Equipamentos Odontológicos , Humanos , Equipamentos Odontológicos/normas , Consenso
5.
BMC Oral Health ; 24(1): 648, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38824549

RESUMO

BACKGROUND: Ensuring the safety of dental unit waterlines (DUWLs) has become a pivotal issue in dental care practices, focusing on the health implications for both patients and healthcare providers. The inherent structure and usage conditions of DUWLs contribute to the risk of biofilm formation and bacterial growth, highlighting the need for effective disinfection solutions.The quest for a disinfection method that is both safe for clinical use and effective against pathogens such as Staphylococcus aureus and Escherichia coli in DUWLs underscores the urgency of this research. MATERIALS: Chlorine dioxide disinfectants at concentrations of 5, 20, and 80 mg/L were used to treat biofilms of S. aureus and E. coli cultured in DUWLs. The disinfection effectiveness was assessed through bacterial counts and culturing. Simultaneously, human skin fibroblast cells were treated with the disinfectant to observe changes in cell morphology and cytotoxicity. Additionally, the study included corrosion tests on various metals (carbon steel, brass, stainless steel, aluminum, etc.). RESULTS: Experimental results showed that chlorine dioxide disinfectants at concentrations of 20 mg/L and 80 mg/L significantly reduced the bacterial count of S. aureus and E. coli, indicating effective disinfection. In terms of cytotoxicity, higher concentrations were more harmful to cellular safety, but even at 80 mg/L, the cytotoxicity of chlorine dioxide remained within controllable limits. Corrosion tests revealed that chlorine dioxide disinfectants had a certain corrosive effect on carbon steel and brass, and the degree of corrosion increased with the concentration of the disinfectant. CONCLUSION: After thorough research, we recommend using chlorine dioxide disinfectant at a concentration of 20 mg/L for significantly reducing bacterial biofilms in dental unit waterlines (DUWLs). This concentration also ensures satisfactory cell safety and metal corrosion resistance.


Assuntos
Biofilmes , Compostos Clorados , Equipamentos Odontológicos , Desinfecção , Escherichia coli , Óxidos , Staphylococcus aureus , Compostos Clorados/farmacologia , Óxidos/farmacologia , Biofilmes/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Humanos , Staphylococcus aureus/efeitos dos fármacos , Desinfecção/métodos , Equipamentos Odontológicos/microbiologia , Desinfetantes/farmacologia , Desinfetantes de Equipamento Odontológico/farmacologia , Fibroblastos/efeitos dos fármacos , Carga Bacteriana/efeitos dos fármacos , Técnicas In Vitro
6.
J Am Dent Assoc ; 155(6): 515-525.e1, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38839239

RESUMO

BACKGROUND: Dental unit waterline (DWL) infection control is critical to infection prevention. Identifying challenges and barriers to its implementation is a first step toward understanding how to improve engagement. METHODS: A survey was distributed to dentists, dental hygienists, and dental assistants via the Qualtrics XM platform (Qualtrics). Responses were analyzed to quantify engagement in practices contrary to Centers for Disease Control and Prevention guidance and identify avenues to improve engagement. RESULTS: Although oral health care providers recognized DWL infection control was important, there was a lack of clarity about appropriate routine engagement (eg, what lines should be tested), what should be noted in practice infection control records, and steps to be taken in response to a failed test result (ie, ≥ 500 colony-forming units/mL), such as taking a chair out of service. CONCLUSIONS: Survey results showed there were considerable gaps in knowledge and practice that could lead to patient harm. Oral health care provider training may not prepare personnel adequately to engage in, let alone supervise, DWL infection control. DWL infection control, like other aspects of infection control, requires action informed via an understanding of what needs to be done. Although good intentions are appreciated, better approaches to DWL infection control information dissemination and strategies to engage dental assistants, dental hygienists, and dentists in best practices are needed. PRACTICAL IMPLICATIONS: Evolving standards of care, including infection control, should be reflected in the provision of dental treatment. Improvements in communicating and ensuring engagement in best practices are needed when it comes to DWL infection control.


Assuntos
Controle de Infecções Dentárias , Humanos , Controle de Infecções Dentárias/métodos , Higienistas Dentários , Inquéritos e Questionários , Odontólogos , Equipamentos Odontológicos , Contaminação de Equipamentos/prevenção & controle , Conhecimentos, Atitudes e Prática em Saúde , Assistentes de Odontologia
7.
Indian J Dent Res ; 35(1): 80-83, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38934755

RESUMO

BACKGROUND: Dental Unit Water Line (DUWL) deliver water to different handpieces in a dental unit. The water in DUWL circulates in a closed system, where it is taken from a container. The quality of dental water is of considerable importance since patients and dental staff are regularly exposed to water and aerosols generated from dental equipment. Output water from DUWLs may be a potential source of infection for both dental health care personnel and patients. AIM: To assess the microbial contamination in the DUWL among dental clinics in Chennai. MATERIALS AND METHODS: An in vitro study was conducted on 60 water samples from 20 dental clinics in Chennai in December 2019. Water samples were collected from three different sources of the Dental unit according to ADA guidelines. The collected samples were assessed for the presence of Aspergillus, Acinetobacter, Pseudomonas aeruginosa, and Legionella by agar plate method. The data were analysed using SPSS software version 20. RESULTS: Legionella was the most prevalent microorganism with 70% prevalence in a three-way syringe and 50% in scaler and airotor, followed by Pseudomonas aeruginosa and Acinetobacter with 10% prevalence in scaler and airotor and Aspergillus with a prevalence of 10% in the three-way syringe. CONCLUSION: Most of the dental units were contaminated with Aspergillus, Legionella, Pseudomonas aeruginosa and Acinetobacter which pose a serious threat to the patients as well as the dentists.


Assuntos
Clínicas Odontológicas , Equipamentos Odontológicos , Contaminação de Equipamentos , Legionella , Microbiologia da Água , Índia , Equipamentos Odontológicos/microbiologia , Humanos , Legionella/isolamento & purificação , Pseudomonas aeruginosa/isolamento & purificação , Acinetobacter/isolamento & purificação , Técnicas In Vitro
8.
Microbiol Spectr ; 12(6): e0396223, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38652098

RESUMO

Water contamination in dental unit waterlines (DUWLs) is a potential source of healthcare-associated infection during dental care. The aim of this study was to evaluate the microbiological quality of DUWLs water from newly installed dental chairs in a French University Hospital. The microbiological quality of water from 24 new DUWLs initially disinfected by ICX Renew-prior to use of the dental units for patient treatment-was assessed for total culturable aerobic bacteria at 22°C and 36°C, Legionella sp., Pseudomonas aeruginosa, and total coliforms. Among the 24 samples analyzed, 21 were compliant with the water quality levels: 19 had no bacteria, and 2 contained only 4 and 1 CFU/mL for total culturable aerobic bacteria at 22°C and 36°C, respectively. Three samples were non-compliant due to contamination by P. aeruginosa (4, 2, and 2 CFU/100 mL). Controlling and preventing the microbiological contamination of DUWLs, especially by pathogenic bacteria, at the time of the installation of the new dental chairs are crucial to prevent healthcare-associated infection in dentistry. IMPORTANCE: Dental unit waterlines (DUWLs) of new dental chairs may be contaminated before their first clinical use, so an initial shock disinfection is crucial at the time of their installation. The microbiological analyses are crucial to control the water quality of DUWLs before their first clinical use because their disinfection does not guarantee the elimination of all bacteria.


Assuntos
Pseudomonas aeruginosa , Microbiologia da Água , Pseudomonas aeruginosa/isolamento & purificação , Humanos , Desinfecção/métodos , Equipamentos Odontológicos/microbiologia , Contaminação de Equipamentos , Infecção Hospitalar/microbiologia , Infecção Hospitalar/prevenção & controle , França , Legionella/isolamento & purificação
9.
BMC Oral Health ; 23(1): 867, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37968643

RESUMO

OBJECTIVES: This retrospective study examined the dental unit waterline (DUWL) testing practices of Saskatchewan dental clinics over a period of 11 years, with an emphasis on their responses after identification of high microbial levels. MATERIALS AND METHODS: Dental clinics (n = 137) aseptically collected samples of output water from their air/water syringes, handpieces, and ultrasonic scaler lines using Sigma-Aldrich® waterline test kits and delivered them to a quality assurance laboratory. Tests were incubated for seven days at room temperature, and those with heterotrophic plate counts > 500 CFU/mL were reported as failures. Statistical analyses were performed on a database containing 4,093 test results. RESULTS: Participating clinics submitted an average of 11 DUWL tests per year. Overall, 21% of tests failed, and a moderate positive association (rs=.52, p < 0.001) was found between clinics' DUWL testing frequency and failure rate. Only 7% of failed DUWL tests were followed up by collection of a subsequent test within two weeks, of which 47% still exceeded the 500 CFU/mL threshold. CONCLUSIONS: Our findings demonstrate an association between DUWL testing frequency and detection of unacceptable microbial levels, along with infrequent retesting and often-inadequate intervention after a failed test. This suggests the need for further efforts at the regulatory and educational levels to maintain adequate water quality during dental treatment. CLINICAL RELEVANCE: Procedural water can become contaminated in DUWLs and endanger patients. Regular DUWL monitoring and evidence-based interventions to treat contaminated systems are necessary to safeguard patient health.


Assuntos
Biofilmes , Equipamentos Odontológicos , Humanos , Estudos Retrospectivos , Contagem de Colônia Microbiana , Contaminação de Equipamentos
10.
BMC Oral Health ; 23(1): 865, 2023 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-37964280

RESUMO

BACKGROUND: In dentistry, nosocomial infection poses a great challenge to clinicians. The microbial contamination of water in dental unit waterlines (DUWLs) is ubiquitous. Such infected DUWLs can transmit oral microbes in the form of aerosols. Previous studies have suggested treating DUWLs with various disinfectants to reduce cross-contamination. The literature lacks a comparative evaluation of the effect of the use of 0.2% chlorhexidine (CHX) and 0.1% sodium hypochlorite (NaOCl) in DUWLs on aerosolized bacteria generated during dental procedures. OBJECTIVE: To compare the effect of NaOCl and CHX in DUWLs on aerosolized bacteria generated during restorative and endodontic procedures. MATERIALS AND METHODS: A total of 132 patients were equally divided into three groups (n = 44 in each group) according to the content of DUWL as follows. Group I-0.1% NaOCl Group II-0.2% CHX Group III-distilled water (Positive control) One-way ANOVA was performed and the Kruskal-Wallis test was used for intergroup comparison. RESULTS: For the restorative procedure, inter-group comparison of mean colony-forming units (CFU) scores showed a statistically significant difference between the groups (p - .001) with the score of group 3 higher than group 2 followed by group 1. For the endodontics, an inter-group comparison of CFU scores showed a statistically significant difference between the groups (p - .003) with the mean score in group 1 being the lowest and group 3 being the highest. CONCLUSION: The addition of NaOCl or CHX in DUWLs shows an effective reduction in aerosolized bacteria compared to distilled water.


Assuntos
Clorexidina , Hipoclorito de Sódio , Humanos , Bactérias , Clorexidina/farmacologia , Clorexidina/uso terapêutico , Contagem de Colônia Microbiana , Assistência Odontológica , Equipamentos Odontológicos/microbiologia , Hipoclorito de Sódio/farmacologia , Água/farmacologia
12.
PeerJ ; 11: e15830, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37576504

RESUMO

Background: This study compared the ability of thermally treated files in shaping simulated canals with double curvature. Fifty-six canals were enlarged to a final size of 25 with ProTaper Next (PTN) or ZenFlex (ZF). Materials: Half of the samples were shaped with cooled files (n = 14 each). The amount of removed resin was measured and canal deviation was determined at eight levels. Shaping time and maximum shaping torque values were also recorded. Data were statistically analyzed using analysis of variance and LSD, Kruskal-Wallis, and chi-square tests at a 0.05 significance level. Results: Compared to PTN and cooled PTN, ZF and cooled ZF required lesser time to shape the canals. The maximum torques were found comparable between the groups. All the groups generated negligible deviations at every canal level evaluated and maintained the canal geometry. Although not significant, the cooled PTN and ZF files exhibited lesser canal deviations than their counterparts. Conclusion: All groups demonstrated similar shaping ability whilst maintaining the original curvature of the canal in simulated canals with double curvature. However, ZF groups were able to shape the canals faster than PTN groups. There was a trend that cooled files made lesser canal deviations compared to their counterparts.


Assuntos
Temperatura Baixa , Equipamentos Odontológicos , Preparo de Canal Radicular , Desenho de Equipamento , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Preparo de Canal Radicular/normas , Torque , Análise de Variância , Equipamentos Odontológicos/normas
13.
BMC Oral Health ; 23(1): 158, 2023 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-36934281

RESUMO

BACKGROUNDS: Numerous studies have shown that dental unit water lines (DUWLs) are often contaminated by a wide range of micro-organisms (bacteria, fungi, protozoa) and various prevalence have been reported for it in previous studies. Therefore, this review study aims to describe the prevalence of bacterial biofilm contamination of DUWLs. METHODS: This is a systematic review and meta-analysis in which the related keywords in different international databases, including Medline (via PubMed) and Scopus were searched. The retrieved studies were screened and the required data were extracted from the included studies. Three standard methods including American Dental Association (ADA), The Center for Disease Control and Prevention (CDC) and contaminated > 100 CFU/ml(C-100) standards were used to assess the bacterial biofilm contamination of DUWLs. All studies that calculated the prevalence of bacterial biofilm contamination of DUWLs, and English full-text studies were included in the meta-analysis. Studies that did not have relevant data or used unusual laboratory methods were excluded. Methodological risk of bias was assessed by a related checklist and finally, the data were pooled by fixed or random-effect models. RESULTS: Seven hundred and thirty-six studies were identified and screened and 26 related studies were included in the meta-analysis. The oldest included study was published in 1976 and the most recent study was published in 2020. According to the ADA, CDC and C-100 standards, the prevalence of bacterial contamination was estimated to be 85.0% (95% confidence interval (CI): 66.0-94.0%), 77.0% (95%CI: 66.0-85.0%) and 69.0% (95%CI: 67.0-71.0%), respectively. The prevalence of Legionella Pneumophila and Pseudomonas Aeruginosa in DUWLs was estimated to be 12.0% (95%CI: 10.0-14.0%) and 8.0% (95%CI: 2.0-24.0%), respectively. CONCLUSION: The results of this review study suggested a high prevalence of bacterial biofilm in DUWLs; therefore, the use of appropriate disinfecting protocol is recommended to reduce the prevalence of contamination and reduce the probable cross-infection.


Assuntos
Bactérias , Equipamentos Odontológicos , Humanos , Equipamentos Odontológicos/microbiologia , Prevalência , Biofilmes , Contaminação de Equipamentos/prevenção & controle , Contagem de Colônia Microbiana
14.
Indian J Dent Res ; 34(3): 266-269, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38197344

RESUMO

Aim: : The aim of this study was to measure the amount of material extruded in the periapical area using three irrigation needles (Max-I-Probe, NaviTip Fx and IrriFlex flexible needle). Materials and Methods: : Mandibular premolars were selected for this study and glass vials were used to gather the extruded debris and they were preweighed. The samples were divided into two groups: Group A (1 mm penetration of needle from working length), which was subdivided into three subgroups: Subgroup A1: Irrigation was made by Max-I-Probe. Subgroup A2: Irrigation was made by NaviTip Fx. Subgroup A3: Irrigation was made by IrriFlex flexible needle. Group B (3 mm penetration of needle), which was subdivided into three subgroups: Subgroup B1: Irrigation was made by Max-I-Probe. Subgroup B2: Irrigation was made by NaviTip Fx. Subgroup B3: Irrigation was made by IrriFlex flexible needle. XP-endo Shaper was used for chemomechanical preparation. After removal from vials, the teeth were incubated and then removed from the incubator and weighed again three times. The average of the readings was taken. Analysis of variance (ANOVA) and least significance difference tests were applied to analyse data. Results: : All of the needles caused debris extrusion. There was a significant difference between groups (P ≤ 0.001) according to the depth of penetration. The lowest value for debris was observed in subgroup B3 while subgroup A2 had shown the highest mean. Conclusion: Results revealed that the design and depth of needles significantly affected the debris extrusion. Using more flexible needles and shorter penetration depth for irrigation so that we don't need to push the needles so far apically.


Assuntos
Equipamentos Odontológicos , Desenho de Equipamento , Agulhas , Análise de Variância , Irrigação Terapêutica
15.
Artigo em Inglês | MEDLINE | ID: mdl-36078275

RESUMO

In dental clinics, the infections may be acquired through contaminated devices, air, and water. Aerosolized water may contain bacteria, grown into the biofilm of dental unit waterlines (DUWLs). We evaluated a disinfection method based on water osmosis and chlorination with chlorine dioxide (O-CD), applied to DUWL of five dental clinics. Municipal water was chlorinated with O-CD device before feeding all DUWLs. Samplings were performed on water/air samples in order to research total microbial counts at 22-37 °C, Pseudomonas aeruginosa, Legionella spp., and chlorine values. Water was collected from the taps, spittoons, and air/water syringes. Air was sampled before, during, and after 15 min of aerosolizing procedure. Legionella and P. aeruginosa resulted as absent in all water samples, which presented total microbial counts almost always at 0 CFU/mL. Mean values of total chlorine ranged from 0.18-0.23 mg/L. Air samples resulted as free from Legionella spp. and Pseudomonas aeruginosa. Total microbial counts decreased from the pre-aerosolizing (mean 2.1 × 102 CFU/m3) to the post-aerosolizing samples (mean 1.5 × 10 CFU/m3), while chlorine values increased from 0 to 0.06 mg/L. O-CD resulted as effective against the biofilm formation in DUWLs. The presence of residual activity of chlorine dioxide also allowed the bacteria reduction from air, at least at one meter from the aerosolizing source.


Assuntos
Desinfecção , Legionella , Bactérias , Biofilmes , Cloro/farmacologia , Compostos Clorados , Contagem de Colônia Microbiana , Equipamentos Odontológicos , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Osmose , Óxidos , Pseudomonas aeruginosa , Água , Microbiologia da Água
16.
Biofouling ; 38(6): 628-642, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35924695

RESUMO

Biosafety in dentistry aims to combat cross-contamination and biofilm in dental unit waterlines. The aim was to investigate from a physical, chemical, mechanical and biological perspective, a protocol for using chemical products (citric acid, sodium bicarbonate and sodium chloride) to improve and maintain water quality in dental unit waterlines. Change in microhardness and corrosion tendency were observed in stainless steel samples. On the polyurethane surfaces, there were changes in color, microhardness and roughness. Anti-biofilm evaluations revealed a significant reduction in the biofilm biomass, metabolic activity and residual biofilm. These findings suggest that the protocol analyzed in this study showed an innovative potential against biofilm in dental unit waterlines, preserving the physical, chemical and mechanical properties of the materials.


Assuntos
Biofilmes , Contaminação de Equipamentos , Contagem de Colônia Microbiana , Corrosão , Equipamentos Odontológicos , Microbiologia da Água
17.
J Dent Res ; 101(10): 1198-1204, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35492016

RESUMO

Oral microbes are dispersed during dental treatment and reduction methods have been proposed, but dental unit waterline (DUWL) disinfectants have received little attention; specifically, the effect on viruses has not been studied. This study aims to 1) investigate the effect of DUWL disinfectants on viral dispersion in dental bioaerosols and 2) establish a dual-tracer system using live bacteriophage and fluorescein supported by optical particle measurement. Bacteriophage MS2 was used as a viral tracer and fluorescein as a fluorescent tracer. Validation experiments were conducted to exclude interference of one tracer with the other or of DUWL disinfectants on detection methods. Simulated "saliva" containing the tracers was infused into the mouth of a dental mannequin during 10-min dental procedures with an air turbine handpiece (n = 3 replicates). Aerosols and droplets were sampled in an enclosed dental operatory using air samplers and settlement onto sterile filter papers. Bacteriophage was quantified using plaque assays and reverse transcription quantitative polymerase chain reaction (RT-qPCR). Fluorescein was quantified fluorometrically. The effect of DUWL disinfectants on total aerosol concentration was assessed in separate experiments using an optical particle counter. DUWL disinfectants reduced bacteriophage viability, and interference between tracers was not observed. In simulated clinical procedures, the disinfectant ICX reduced bacteriophage detection substantially (P < 0.001; 2-way analysis of variance). MS2 RNA was detected in all experimental samples but not negative controls. Samples positive on RT-qPCR but not plaque assays may indicate that virions at distant sites are nonviable. Fluorescein tracer showed good agreement with the bacteriophage tracer. DUWL disinfectants designed for continuous presence in irrigants reduce the dispersion of viable virus in dental bioaerosols during simulated procedures. Their use may therefore be important for routine infection control and as a mitigation factor during infectious disease outbreaks. Future studies should explore this using a range of viruses and other microbes.


Assuntos
Desinfetantes , Aerossóis/análise , Desinfetantes de Equipamento Odontológico/farmacologia , Desinfetantes de Equipamento Odontológico/uso terapêutico , Equipamentos Odontológicos , Desinfetantes/farmacologia , Fluoresceínas
18.
Ned Tijdschr Tandheelkd ; 129(2): 63-65, 2022 Feb.
Artigo em Holandês | MEDLINE | ID: mdl-35133735

RESUMO

An implantable cardioverter defibrillator (ICD) is often placed in patients at high risk of ventricular tachycardia and ventricular fibrillation. An ICD is potentially sensitive to electromagnetic interference (EMI) from dental equipment. Between 2000 to 2020, this was investigated in 7 in vitro studies and 4 in vivo studies. Most dental equipment appears to be safe for routine use in patients with an ICD. However, caution seems appropriate with regard to the use of piezoelectic and magnetostrictive scalers as some can cause EMI up to a distance of 20 to 45 centimeter. Use of an electrotome appears to be contraindicated in ICD wearers.


Assuntos
Desfibriladores Implantáveis , Equipamentos Odontológicos , Campos Eletromagnéticos , Humanos
19.
Oral Health Prev Dent ; 20(1): 61-68, 2022 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-35049253

RESUMO

PURPOSE: A number of disinfectants and sanitisers are used in dentistry, and there are numerous commercial solutions available. Nonetheless, because each cleaning solution has its own set of indications and limits, there is no one-size-fits-all approach for processing all types of dental equipment. Functional water, such as electrolysed hypochlorite microbubbled water, efficiently eliminates and sterilises biofilms. The objective of the study was to evaluate whether ozonated water could be used to sterilise and disinfect dental-unit water pipelines (DUWP) that had been contaminated with micro-organisms, including Gram-positive and Gram-negative bacilli and cocci. MATERIALS AND METHODS: Three different groups were formed: group A - ozonated water (Cantoosh); group B - 1% povidine iodine; and group C: conventional distilled water. Group A was the test group, group B the control group, and group C was the positive control group. The water sterilising system was replaced with the appropriate sterilising agent as per the allocated group classification, with 2 min of purging, so that the complete DUWP was filled with the water sterilising system. Samples were collected and analysed, along with a 2-min purge after 24 h, 7 days and 21 days, at the 3 outlet (OL) points: the 3-way syringe at the dental tray(OL1), the cup filler (OL2), and the 3-way syringe of the assistant zone (OL3). Repeated measures ANOVA was used to test for statistical significance between colony-forming units of control and experimental groups (p < 0.05). RESULTS: The cup filler yielded higher counts than did the 3-way syringe at the dental tray (OL1) (6.40 and 8.05 on the log scale, respectively). A statistically significant difference in the CFUs was also observed between samples taken after 24 h vs 21 days between groups A, B and C. CONCLUSION: The findings showed that exposing DUWP tube systems to ozonated water for an extended length of time drastically lowered the number of microorganisms adhering to their surfaces.


Assuntos
Equipamentos Odontológicos , Água , Biofilmes , Contagem de Colônia Microbiana , Humanos , Microbiologia da Água
20.
Medicine (Baltimore) ; 100(47): e28019, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34964798

RESUMO

ABSTRACT: The water quality of dental unit waterlines (DUWLs) is associated with patient safety. No program for DUWL water quality improvement has been formulated since the time they were established 20 years ago. This study provides an improvement program for the quality of dental unit water. The improvement program was implemented step by step: discharge of DUWLs for 5 minutes in the morning before clinical service to flush out the water left in the pipeline overnight; weekly disinfection of the handpiece connector with 75% alcohol and replacement of the old connector when the water quality of the same dental chair unit (DCU) was continuously found to be unqualified; monthly disinfection of the water supply system and pipeline; and establishment of DCU maintenance work standards and staff education and training. From 2016 to 2018, the water quality of 18 DCUs was tested by microorganism culture. The colonies >200 colony forming unit were categorized as unqualified. This program was divided into a pre-test phase, Phase 1, a maintenance phase, and Phase 2. A Chi-square test was used to calculate the difference of unqualified water quality numbers between each phase of the improvement program. In the pre-test phase, the water quality rate (high quality number/high-quality number + low-quality number) was 58.3%. In Phase 1, the quality rate before and after the intervention was 64.8% (35/54) and 92.2% (83/90) (P < .001), respectively. After Phase 1, the quality rate reached 100%. However, the quality rate dropped to 75% during the maintenance phase. Then, we proceeded into Phase 2 of the improvement program by further monthly disinfection to DUWLs. In Phase 2, the quality rate was 62/73 (84.9%) and improved to 142/144 (98.6%) after the intervention (P < .001). The quality rate reached 100% once again and was maintained at 100% thereafter. In conclusion, the 4 steps of the improvement program improved the water quality of the DUWL, which is important for patient safety.


Assuntos
Equipamentos Odontológicos/microbiologia , Desinfecção , Contaminação de Equipamentos/prevenção & controle , Microbiologia da Água , Qualidade da Água , Abastecimento de Água/normas , Biofilmes , Contagem de Colônia Microbiana , Desinfetantes/uso terapêutico , Hospitais , Humanos , Desenvolvimento de Programas , Melhoria de Qualidade