Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.521
Filtrar
1.
Proc Inst Mech Eng H ; 238(4): 403-411, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38602217

RESUMO

External fixation is an essential surgical technique for treating trauma, limb lengthening and deformity correction, however infection is common, with infection rates ranging from 4.5 to 100% of cases. Throughout the literature researchers and clinicians have highlighted a relationship between excessive movement of the pin and skin and an increase in the patient's risk of infection, however, currently no studies have addressed this role of pin-movement on pin-site wounds. This preliminary study describes a novel in vitro pin-site model, developed using a full-thickness human skin equivalent (HSE) model in conjunction with a bespoke mechanical system which simulates pin-movement. The effect of pin-movement on the wound healing response of the skin equivalents was assessed by measuring the expression of pro-inflammatory cytokines. Six human skin equivalent models were divided into three test groups: no pin as the control, static pin-site wound and dynamic pin-site wound (n = 3). On day 3 concentrations of IL-1α and IL-8 showed a significant increase compared to the control when a static fixation pin was implanted into the skin equivalent (p < 0.05) and (p < 0.005) respectively. Levels of IL-1α and IL-8 increased further in the dynamic sample compared to the static sample (p < 0.05) and (p < 0.0005). This study demonstrates for the first time the application of HSE model to study external-fixation pin-movement in vitro. The results of this study demonstrated pin-movement has a negative effect on soft-tissue wound-healing, supporting the anecdotal evidence reported in the literature, however further analysis of wound heading would be required to verify this hypothesis.


Assuntos
Fixadores Externos , Fixação de Fratura , Humanos , Fixação de Fratura/métodos , Infecção da Ferida Cirúrgica/terapia , Interleucina-8 , Pinos Ortopédicos , Cicatrização/fisiologia
2.
BMC Musculoskelet Disord ; 25(1): 284, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609889

RESUMO

BACKGROUND: The purpose of the study was to assess and compare the clinical efficacy of bone transport with either circular or unilateral external fixators over an intramedullary nail in the treatment of tibial bone defects caused by infection. METHODS: Between May 2010 and January 2019, clinical and radiographic data were collected and analyzed for patients with bone defects caused by infection. Thirteen patients underwent bone transport using a unilateral external fixator over an intramedullary nail (Group A), while 12 patients were treated with a circular external fixator over an intramedullary nail (Group B). The bone and functional outcomes of both groups were assessed and compared using the Association for the Study and Application of the Method of the Ilizarov criteria, and postoperative complications were evaluated according to the Paley classification. RESULTS: A total of 25 patients were successfully treated with bone transport using external fixators over an intramedullary nail, with a mean follow-up time of 31.63 ± 5.88 months. There were no significant statistical differences in age, gender, previous surgery per patient, duration of infection, defect size, and follow-up time between Group A and Group B (P > 0.05). However, statistically significant differences were observed in operation time (187.13 ± 21.88 min vs. 255.76 ± 36.42 min, P = 0.002), intraoperative blood loss (39.26 ± 7.33 mL vs. 53.74 ± 10.69 mL, P < 0.001), external fixation time (2.02 ± 0.31 month vs. 2.57 ± 0.38 month, P = 0.045), external fixation index (0.27 ± 0.08 month/cm vs. 0.44 ± 0.09 month/cm, P = 0.042), and bone union time (8.37 ± 2.30 month vs. 9.07 ± 3.12, P = 0.032) between Group A and Group B. The excellent and good rate of bone and functional results were higher in Group A compared to Group B (76.9% vs. 75% and 84.6% vs. 58.3%). Statistically significant differences were observed in functional results (excellent/good/fair/poor, 5/6/2/0 vs. 2/5/4/1, P = 0.013) and complication per patient (0.38 vs. 1.16, P = 0.012) between Group A and Group B. CONCLUSIONS: Bone transport using a combined technique of external fixators over an intramedullary nail proved to be an effective method in treating tibial bone defects caused by infection. In comparison to circular external fixators, bone transport utilizing a unilateral external fixator over an intramedullary nail resulted in less external fixation time, fewer complications, and better functional outcomes.


Assuntos
Fixadores Externos , Osteopatia , Humanos , Estudos Retrospectivos , Fixação de Fratura , Fixadores Internos
3.
Sci Rep ; 14(1): 7724, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565922

RESUMO

Transarticular external skeletal fixation (TESF) is repeatedly used for temporary stabilisation of tarsal joint in cats. Hence, this study aimed to evaluate the use of temporary modified type II TESF for management of talocrural instability (TCI) in cats without joint arthrodesis and to rate short-term outcomes and complications. Medical records of all cats treated for TCI between January 2012 and December 2021 were reviewed. Information was collected including signalment, degree of lameness, type of TCI, accompanying soft tissue and bone injuries, and post-operative follow-up assessment including time of frame removal, complications, degree of lameness, range of joint motion and ankylosis. Surgical management didn't involve debridement of the articular cartilage. Eighty-five percent of cats had satisfactory joint stability at the time of frame removal. Eighteen cats exhibited minor complications, six cats had major complications, and 8 cats showed persistent lameness. All cats showed reduction of joint motion range by 20°-30° directly after frame removal while returned to normal in 79% of cats 4 weeks later. Variable degrees of joint ankylosis were reported. In conclusion, this study supports the use of temporary modified type II TESF for management of TCI in cats without joint involvement as an excellent alternative to tarsal arthrodesis.


Assuntos
Anquilose , Luxações Articulares , Gatos , Animais , Fixadores Externos/veterinária , Coxeadura Animal , Fixação de Fratura , Luxações Articulares/cirurgia , Anquilose/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
4.
J Orthop Surg Res ; 19(1): 231, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589910

RESUMO

BACKGROUND: Internal and external fixation are common surgical procedures for treating fractures. However, the impact of different surgical approaches (including internal and external fixations) on patients' psychological status and Quality of Life (QoL) is rarely examined. Herein, we aimed to investigate the effects of internal and external fixation on anxiety, depression, insomnia, and overall mental and physical health in Distal Radius Fractures (DRF) patients. METHODS: We performed a retrospective study on 96 fracture patients who underwent internal fixation (57 patients) or external fixation (39 patients). The Visual Analog Scale (VAS), the Hospital Anxiety and Depression Scale (HADS), the Athens Insomnia Scale (AIS), and the Medical Outcomes Study Short Form 36 (SF-36) questionnaire were used to assess the patients' pain, anxiety, depression, sleep, and QoL before surgery and at seven days, one month, and three months post-surgery. RESULTS: The VAS scores were significantly lower in the Internal Fixation Group (IFG) than in the External Fixation Group (EFG) on the seventh day and one month postoperatively (P < 0.05). Although both groups showed no significant anxiety, depression, or insomnia before surgery (P > 0.05), the EFG showed significantly higher HADS-A, HADS-D, and AIS scores than the IFG at seven days and one and three months postoperatively (P < 0.05). Additionally, changes in HADS-A, HADS-D, and AIS scores were most significant at day seven post-surgery in the EFG (P < 0.05). Furthermore, no significant difference was found between the two groups in the average Physical Component Summary (PCS) and Mental Component Summary (MCS) scores before surgery (P > 0.05). However, both groups showed positive changes in PCS and MCS scores at postoperative day seven and one and three months postoperatively, with the IFG having significantly higher average PCS and MCS scores compared to the EFG (P < 0.05). CONCLUSION: Compared to external fixation, internal fixation did not significantly impact patients' emotions regarding anxiety and depression in the early postoperative period, and physical and mental health recovery was better during the postoperative rehabilitation period. Furthermore, when there are no absolute indications, the impact on patients' psychological well-being should be considered as one of the key factors in the treatment plan during surgical approach selection.


Assuntos
Fraturas Ósseas , Distúrbios do Início e da Manutenção do Sono , Humanos , Qualidade de Vida , Distúrbios do Início e da Manutenção do Sono/etiologia , Fixadores Externos , Estudos Retrospectivos , Fixação de Fratura/efeitos adversos , Fixação Interna de Fraturas/efeitos adversos , Fenômenos Físicos
5.
J Pak Med Assoc ; 74(3): 440-444, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38591274

RESUMO

Objective: To determine the combined column tibial plateau fracture treated with a hybrid external fixator in terms of knee functionality, union outcome and complications. METHODS: The quasi-experimental study was conducted at the Department of Orthopaedic Surgery, Mayo Hospital, Lahore, Pakistan, from July 5, 2019, to December 31, 2021, and comprised patients of either gender aged 20-50 years who presented with 2-column or 3-column fractures of proximal tibia classified according to the 3-column classification system after being diagnosed using radiographs and three-dimensional computed tomography scan. Knee function, union and complications, like neural, vascular, infection, delayed union, nonunion, malunion and implant failure, were evaluated. The Knee Society Score was used to assess knee function, and modified Rasmussen score for the union, while complications were assessed clinically on the 2nd, 6th, 12th, 16th, 24th, 36th weeks and one year post-operatively. Data was analysed using SPSS 26. RESULTS: Of the 113 patients, 91(80.53%) were males and 22(19.47%) were females. The overall mean age was 35.56±9.00 years. From the 12th week to the 24th week 45(39.83%) patients had good and 59(52.21%) patients had excellent functional outcomes. Union outcome in the 16th and 24th week was good in 57(50.44%) patients and excellent in 47(41.59%) patients. No neurovascular injury was observed. Superficial pin tract infection was observed in 21(18.6%) cases that healed with wound debridement and antibiotics. No delayed union, malunion and implant failure was observed. CONCLUSIONS: Good to excellent functional and union outcomes with minimum complications were observed with the hybrid external fixator.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Masculino , Feminino , Humanos , Adulto , Resultado do Tratamento , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fixadores Externos , Fixação de Fratura/métodos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos
6.
J Pediatr Orthop ; 44(5): e419-e425, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38595313

RESUMO

BACKGROUND: Congenital pseudarthrosis of the tibia (CPT) is a rare disease. CPT is often unilateral and occurs between the middle and distal third of the tibia. Concurrent involvement of the fibula is present in more than half of cases. histologic studies indicate the presence of fibrous hamartoma tissue and a sick periosteum, which leads to recalcitrant bone fracture and, eventually, pseudoarthrosis. Although there are various surgical techniques, we intend to compare the 2 methods of external fixation versus internal plating. METHODS: Demographic data were collected from 26 patients with frank pseudoarthrosis. After exclusion criteria, patients were compared in groups A (12 patients) and B (11 patients). Resection of hamartoma and sclerotic bone, intramedullary rodding and autologous bone, and periosteal grafting were performed for all patients. In group A, we used a ring external fixator for compression and rotational stability, but in group B, a locking plate was used for these purposes. RESULTS: Plating takes less time to use during surgery. In group A, the primary bony union was obtained in 67% of patients, while in group B, 82% of patients had a primary union. Meanwhile, the average time till the final union in group A was 6 months, while in group B, this time was 3.5 months. Positive union mass was obtained in 58% of the patients in group A and 82% of group B. In addition, plating prevented ankle valgus deformity in group B. CONCLUSIONS: Permanent intramedullary rodding is a surgical requirement for correction of deformity and refracture prevention, but additional stability can be achieved with the use of a ring external fixator or internal plate. Cross union and positive union mass are 2 important factors in the treatment of pseudoarthrosis; these results are achieved to a greater extent and in a shorter period of time using the plate. LEVEL OF EVIDENCE: level IV - case series.


Assuntos
Fixação Intramedular de Fraturas , Hamartoma , Pseudoartrose , Pseudoartrose/congênito , Fraturas da Tíbia , Humanos , Tíbia/cirurgia , Tíbia/patologia , Pseudoartrose/cirurgia , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/patologia , Fixação Intramedular de Fraturas/métodos , Fixadores Externos , Fíbula , Placas Ósseas , Estudos Retrospectivos , Hamartoma/patologia , Resultado do Tratamento
7.
Med Sci Monit ; 30: e944136, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38549240

RESUMO

BACKGROUND Tibial fractures, common in adults, are often treated with external or internal fixation methods. While effective, external fixation (EF) can lead to sexual dysfunction (SD), especially in young patients. This study aimed to assess SD in women undergoing EF versus internal fixation for tibial fractures. MATERIAL AND METHODS Sexual function and frequency of monthly sexual intercourse (SI) were evaluated using the Female Sexual Function Index (FSFI) before surgery, with the fixator, after at least 6 months following fixator removal in EF group, and after achieving bone union for at least 3 months in the IF group. RESULTS The EF group consisted of 107 (mean age 28.5 years; 19-40 years) and IF group consisted of 106 patients (mean age 32.1 years; 18-40 years). The duration of EF was an average of 4.7 months (range, 2.5-13 months). FSFI scores were significantly lower in the EF group compared to the IF group (9.33 versus 27.3, P<0.001). Also, there was no significant difference between the FSFI scores before EF and after EF was removed (34.22 versus 33.8, P=0.413). FSFI sub-group scores such as desire, arousal, lubrication, and orgasm were significantly lower in the EF group (P<0.001). The monthly average frequency of SI before surgery and after the removal of EF was 10.2 and 9.1, respectively, while this frequency was 2.56 when EF was present (P<0.001). CONCLUSIONS The quality and frequency of SI in women significantly deteriorate and decrease during the period of extremity fixation following tibial diaphyseal fractures treated with EF, but return to normal after removal.


Assuntos
Disfunções Sexuais Fisiológicas , Fraturas da Tíbia , Adulto , Humanos , Feminino , Estudos Retrospectivos , Fixadores Externos , Fraturas da Tíbia/complicações , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Fixação de Fratura/métodos , Resultado do Tratamento
8.
JBJS Case Connect ; 14(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38484095

RESUMO

CASE: A 23-year-old right-hand dominant man presented with a high-velocity gunshot wound injury to the right thumb with severe soft-tissue damage, vascular injury, and large osseous defect of the right thumb metacarpal. The patient was successfully treated with metacarpophalangeal joint arthrodesis and metacarpal reconstruction using definitive external fixation, an intramedullary Kirschner wire, and use of the Masquelet bone grafting technique. CONCLUSION: The authors' treatment approach for a mangled thumb injury with definitive external fixation and utilization of the Masquelet technique resulted in restoration of a large osseous defect, avoidance of infection, and limited loss of mobility.


Assuntos
Traumatismos da Mão , Procedimentos de Cirurgia Plástica , Ferimentos por Arma de Fogo , Humanos , Masculino , Adulto Jovem , Fixadores Externos , Fixação de Fratura/métodos , Traumatismos da Mão/cirurgia , Polegar/cirurgia , Ferimentos por Arma de Fogo/cirurgia
9.
Artigo em Inglês | MEDLINE | ID: mdl-38537115

RESUMO

INTRODUCTION: External fixation of unstable ankle injuries is commonly done by orthopaedic surgeons. An improper technique can negate the benefits of the procedure and necessitate revision. This study sought to determine the risk factors for revision of external fixation of unstable ankle injuries. METHODS: Retrospective cohort at a level I academic trauma center of 120 consecutive patients underwent external fixation of an unstable ankle injury. Exclusion criteria included external fixation for reason other than fracture, inadequate intraoperative imaging, skeletal immaturity, and follow-up less than 30 days. Primary outcome measurement was revision of external fixation within 30 days. RESULTS: Ninety-seven patients met inclusion criteria. Eighteen (18.6%) underwent revision within 30 days of whom 5 (28%, P < 0.001) had a poor reduction intraoperatively. No patients with a good reduction required revision. Revised patients had a significantly higher talar tilt (P < 0.001) and were more likely to lack a first metatarsal pin (P = 0.018). Multivariate analysis revealed talar tilt >0.5° (odds ratio, 22.62; 95% confidence interval, 6.52 to 50.63) as an independent risk factor for revision. DISCUSSION: For external fixation of unstable ankle injuries, poor reduction quality is a risk factor for need for revision surgery. Orthopaedic surgeons should be critical of their final intraoperative assessment to prevent revision.


Assuntos
Traumatismos do Tornozelo , Fixação de Fratura , Humanos , Estudos Retrospectivos , Fixação de Fratura/métodos , Fixadores Externos , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Fatores de Risco
10.
J Mech Behav Biomed Mater ; 153: 106488, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38437754

RESUMO

INTRODUCTION: This systematic review aims to identify previously used techniques in biomechanics to assess pelvic instability following pelvic injury, focusing on external fixation constructs. METHODS: A systematic literature search was conducted to include biomechanical studies and to exclude clinical trials. RESULTS: Of an initial 4666 studies found, 38 met the inclusion criteria. 84% of the included studies were retrieved from PubMed, Scopus, and Web of Science. The studies analysed 106 postmortem specimens, 154 synthetic bones, and 103 computational models. Most specimens were male (97% synthetic, 70% postmortem specimens). Both the type of injury and the classification system employed varied across studies. About 82% of the injuries assessed were of type C. Two different fixators were tested for FFPII and type A injury, five for type B injury, and fifteen for type C injury. Large variability was observed for external fixation constructs concerning device type and configuration, pin size, and geometry. Biomechanical studies deployed various methods to assess injury displacement, deformation, stiffness, and motion. Thereby, loading protocols differed and inconsistent definitions of failure were determined. Measurement techniques applied in biomechanical test setups included strain gauges, force transducers, and motion tracking techniques. DISCUSSION AND CONCLUSION: An ideal fixation method should be safe, stable, non-obstructive, and have low complication rates. Although biomechanical testing should ensure that the load applied during testing is representative of a physiological load, a high degree of variability was found in the current literature in both the loading and measurement equipment. The lack of a standardised test design for fixation constructs in pelvic injuries across the studies challenges comparisons between them. When interpreting the results of biomechanical studies, it seems crucial to consider the limitations in cross-study comparability, with implications on their applicability to the clinical setting.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Humanos , Fenômenos Biomecânicos , Fixadores Externos , Fixação de Fratura/métodos , Ossos Pélvicos/cirurgia
11.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(3): 284-289, 2024 Mar 15.
Artigo em Chinês | MEDLINE | ID: mdl-38500420

RESUMO

Objective: To analyze the effectiveness comparison of external fixator combined with Kirschner wire fixation and Kirschner wire fixation in the treatment of cubitus varus deformity in children. Methods: A retrospective case-control study was conducted to collect 36 children of postoperative supracondylar humerus fracture complicating cubitus varus deformity between January 2018 and July 2022. Among them, 17 cases were treated with distal humeral wedge osteotomy external fixation combined with Kirschner wire fixation (observation group), and 19 cases were treated with distal humeral wedge osteotomy and Kirschner wire fixation (control group). The baseline data including age, gender, deformity side, time from fracture to operation, carrying angle of the healthy side and preoperative carrying angle of the affected side, elbow flexion and extension range of motion, and lateral condylar prominence index (LCPI) showed no significant difference between the two groups ( P>0.05). The operation time, hospitalization cost, healing time of osteotomy, postoperative complications, and the carrying angle, LCPI, and elbow flexion and extention range of motion were recorded and compared between the two groups. The elbow function was assessed by Oppenheim score at 3 months after operation and at last follow-up. Results: The children in both groups were followed up 13-48 months, with an average of 26.7 months. There was 1 case of needle tract infection in the observation group and 2 cases in the control group, and no nerve injury occurred, the difference in the incidence of complication (5.88% vs 10.53%) between the two groups was not significant ( χ 2=0.502, P=0.593). There was no significant difference in the operation time and fracture healing time between the two groups ( P>0.05); the hospitalization cost of the observation group was significantly higher than that of the control group ( P<0.05). The Oppenheim score of the observation group was significantly better than that of the control group at 3 months after operation ( P<0.05), but there was no significant difference in the Oppenheim score between the two groups at last follow-up ( P>0.05). At last follow-up, the carrying angle of affected side significantly improved in both groups when compared with preoperative ones ( P<0.05); the differences of the pre- and post-operative carrying angle of affected side and elbow flexion and extension range of motion showed no significant differences between the two groups ( P>0.05), but the difference in pre- and post-operative LCPI of the observation group was significantly better than that of the control group ( P<0.05). Conclusion: External fixator combined with Kirschner wire fixation and Kirschner wire fixation both can achieve satisfactory correction of cubitus varus deformity in children, and the former can achieve better short-term functional recovery of elbow joint and reduce the incidence of humeral lateral condyle protrusion.


Assuntos
Articulação do Cotovelo , Hallux Varus , Fraturas do Úmero , Deformidades Congênitas dos Membros , Criança , Humanos , Fios Ortopédicos , Cotovelo , Estudos Retrospectivos , Estudos de Casos e Controles , Fraturas do Úmero/cirurgia , Articulação do Cotovelo/cirurgia , Fixadores Externos , Amplitude de Movimento Articular , Hallux Varus/complicações , Resultado do Tratamento
13.
Injury ; 55(4): 111376, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38307778

RESUMO

INTRODUCTION: External fixators (EF) are widely employed for pediatric tibial shaft fractures, being a prevalent choice in clinical practice. However, they are associated with numerous complications, such as loss of reduction, delayed union, and nonunion. An alternative approach involves the use of Ilizarov external fixators (IEF), which have been documented in the treatment of tibial shaft fractures in various studies. This study endeavors to retrospectively compare the clinical outcomes of EF and IEF in the treatment of pediatric tibial shaft fractures. METHODS: The study retrospectively examined patients aged 5-14 years who underwent treatment for tibial shaft fractures at our institute between January 2017 and January 2023. These individuals were subsequently classified into EF and IEF groups. Exclusions comprised patients presenting with pathological fracture, neuromuscular disorder, metabolic disease, prior tibial fracture or instrumentation, and polytrauma. Additionally, individuals with a follow-up duration of more than 12 months or incomplete medical records were excluded. RESULTS: A total of 45 patients were divided into two groups: the EF group, comprising 24 patients (18 males, 6 females), and the IEF group, consisting of 21 patients (17 males, 4 females). The two groups exhibited no statistically significant differences in terms of sex, age, body weight, time from injury to surgery, AO classification, or concomitant injuries. There were two cases of nonunion in the EF group. Radiological union occurred more rapidly in the IEF group (7.8 ± 0.4 weeks) than in the EF group (9.3 ± 1.1 weeks) (P < 0.05). The mean hospitalization duration differed significantly between the EF group (6.7 ± 3.4 days) and the IEF group (7.5 ± 1.1 days) (P > 0.05). The mean duration of the operative procedure significantly differed between the IEF group (147.8 ± 24.5 min) and the EF group (77.2 ± 43.9 min) (P < 0.001). A significant difference (P < 0.001) in weight-bearing time was observed between the IEF group (2.6 ± 0.7 weeks) and the EF group (9.9 ± 1.4 weeks). According to the Johner-Wruhs criteria, no significant differences were found between the two groups. A significant difference (P < 0.001) in hospitalization costs was observed between the IEF group (7848.0 ± 262.4 $) and the EF group (5403.0 ± 233.3 $). CONCLUSION: EF is cheaper, quicker and simpler and we need more randomized controlled studies and that this is a pilot study only. Both types of surgery are good choices for children. Nevertheless, the IEF group demonstrates advantages such as early weight-bearing capability and faster fracture healing.


Assuntos
Fraturas Expostas , Fraturas da Tíbia , Masculino , Feminino , Humanos , Criança , Estudos Retrospectivos , Projetos Piloto , Fraturas Expostas/cirurgia , Resultado do Tratamento , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/patologia , Fixadores Externos , Consolidação da Fratura
14.
J Orthop Surg Res ; 19(1): 110, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308313

RESUMO

BACKGROUND: To investigate the clinical effects of a unilateral external fixator combined with bone transport and tibio-talar fusion in the treatment of severe postoperative infection of peri-ankle fractures. METHODS: The clinical data of 32 patients (22 men and 10 women) with severe postoperative infection of peri-ankle fractures were retrospectively analyzed. Patients' age ranged from 26 to 62 (mean, 42 ± 9.5) years old. The types of fractures were distal tibia fracture (25 cases), distal tibia and fibula fracture (5 cases), and talus fracture (2 cases). All patients underwent treatment with unilateral external fixation combined with bone transport and tibio-talar fusion. 6 patients with severe infection received two-stage treatment involving focal debridement and external fixation, osteotomy, and bone transport. The remaining 26 patients underwent debridement, external fixation, and osteotomy simultaneously. The length of bone transport, total fixation time of the external fixator, and postoperative complications were recorded for all patients. The efficacy of the treatment was assessed using the American Association of Foot and Ankle Society (AOFAS) ankle-hindfoot score. RESULTS: Patients were followed up for 16-36 months, with an average follow-up time of 24 months. The length of tibia bone transport ranged from 5 to 15 cm, with a mean length of 8.5 cm. The external fixator was applied for 12-24 months, with an average duration of 16 months. One patient suffered from refracture at tibio-talar fusion site, and one patient had external fixation pin-tract infection. No complications, such as recurrent infections (especially the MRSA infection), poor mineralization, refracture, iatrogenic nerve damage or fusion failure, were found in the remaining patients. The preoperative AOFAS ankle-hindfoot function score was 40.0 ± 3.8 (range, 30-52) points, and it increased to 75.0 ± 3.0 (range, 67-78) points at the last follow-up. CONCLUSION: A unilateral external fixator combined with bone transport and tibio-talar fusion is an effective method for treating severe postoperative infection of peri-ankle fractures. This approach is capable of reconstructing large bone defects that remain after clearing the infected lesion. Additionally, it provides stability to the ankle, enhances ankle-hindfoot function, and improves the patient's quality of life.


Assuntos
Fraturas do Tornozelo , Fraturas Ósseas , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Resultado do Tratamento , Fixadores Externos , Fraturas Ósseas/cirurgia , Complicações Pós-Operatórias/etiologia
15.
BMC Surg ; 24(1): 44, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302963

RESUMO

BACKGROUND: It's difficult to treat segmental tibial fractures (STFs), which are intricate injuries associated with significant soft tissue damage. The aim of this study was to compare the clinical effect of hexaxial external fixator (HEF) and intramedullary nail (IMN) in treatment of STFs. METHODS: A total of 42 patients with STFs were finally recruited between January 2018 and June 2022. There were 25 males and 17 females with age range of 20 to 60 years. All fractures were classified as type 42C2 using the Arbeitsgemeinschaftfür Osteosythese/Orthopaedic Trauma Association (AO/OTA) classification. 22 patients were treated with HEF and 20 patients were treated with IMN. The condition of vascular and neural injuries, time of full weight bearing, bone union time and infection rate were documented and analyzed between the two groups. The mechanical medial proximal tibial angle (mMPTA), mechanical posterior proximal tibial angle (mPPTA), mechanical lateral distal tibial angle (mLDTA), mechanical anterior distal tibial angle (mADTA), hospital for special surgery (HSS) knee joint score, American Orthopaedic Foot and Ankle Society (AOFAS) ankle joint score, range of motion (ROM) of flexion of keen joint and ROM of plantar flexion and dorsal flexion of ankle joint were compared between the two groups at the last clinical visit. RESULTS: There were no vascular and neural injuries or other severe complications in both groups. All 22 patients in HEF group underwent closed reduction but 3 patients in IMN group were treated by open reduction. The time of full weight bearing was (11.3 ± 3.2) days in HEF group and (67.8 ± 5.8) days in IMN group(P < 0.05), with bone union time for (6.9 ± 0.8) months and (7.7 ± 1.4) months, respectively(P < 0.05). There was no deep infection in both groups. In the HEF group and IMN group, mMPTA was (86.9 ± 1.5)° and (89.7 ± 1.8)°(P < 0.05), mPPTA was (80.8 ± 1.9)° and (78.6 ± 2.0)°(P < 0.05), mLDTA was (88.5 ± 1.7)° and (90.3 ± 1.7)°(P < 0.05), while mADTA was (80.8 ± 1.5)° and (78.4 ± 1.3)°(P < 0.05). No significant differences were found between the two groups at the last clinical visit concerning HSS knee joint score and AOFAS ankle joint score, ROM of flexion of keen joint and ROM of plantar flexion of ankle joint (P > 0.05). The ROM of dorsal flexion of ankle joint in IMN group was (30.4 ± 3.5)°, better than (21.6 ± 2.8)° in HEF group (P < 0.05). CONCLUSION: In terms of final clinical outcomes, the use of either HEF or IMN for STFs can achieve good therapeutic effects. While HEF is superior to IMN in terms of completely closed reduction, early full weight bearing, early bone union and alignment. Nevertheless, HEF has a greater impact on the ROM of dorsal flexion of the ankle joint, and much more care and adjustment are needed for the patients than IMN.


Assuntos
Fraturas da Tíbia , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Fraturas da Tíbia/cirurgia , Fixadores Externos , Placas Ósseas
16.
Proc Inst Mech Eng H ; 238(2): 187-197, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38314816

RESUMO

This paper presents the outcome of a data review of patients treated with the IOS external fixation system at the Royal Stoke University Hospital: a fixation designed to meet four requirements for external fixation proposed in this paper. Demographic data and outcome were collected and assessed. From 69 initial patients, 64 patients (55 males and 9 females) had an average age of 35.9 years. The mean time to union was 127 days. There were no incidences of malunion, or refracture post fixation removal attributable to the treatment method. In addition, in this cohort, there was no incidence of pin tract infection resulting in osteomyelitis. Of all the factors assessed the only factor to have any significant effect on healing was smoking: an average delay of 31 days. An examination of RUST (radiographic union score tibia) and modified RUST scores illustrated a potential false negative of up to 80%. Hence, this study cannot support the use of either scoring system to diagnose fracture healing. IOS external fixation was shown to be an effective method for the treatment of unstable tibial fractures. The reduction at fixation removal was shown to be very good. There was no incidence of osteomyelitis. It is, therefore, suggested that appropriately used external fixation is a viable alternative to intramedullary nailing if designed and surgically applied using four design principles outlined in this paper. Furthermore, it is proposed that external fixation be designed and applied to meet these four principles.


Assuntos
Fixação Intramedular de Fraturas , Osteomielite , Fraturas da Tíbia , Masculino , Feminino , Humanos , Adulto , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Tíbia , Fixação de Fratura/métodos , Consolidação da Fratura , Osteomielite/etiologia , Resultado do Tratamento , Fixadores Externos
17.
J Am Acad Orthop Surg ; 32(7): e331-e345, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38417145

RESUMO

INTRODUCTION: External fixation is a critical component of orthopaedic fracture management and is used for various conditions, including trauma and pediatric orthopaedics. However, the availability and high cost of external fixation devices are a concern, especially in rural and developing countries. 3D printing technology has shown promise in reducing manufacturing costs and improving accessibility to external fixation devices. The purpose of this study was to evaluate the mechanical properties of a fully 3D-printed desktop external fixation device and compare the results with the mechanical properties of commonly used, clinically available external fixators. METHODS: A fully 3D printable external fixator was designed and printed in polylactic acid at two infill densities, 20% and 100%. The mechanical properties of the 3D-printed external fixators and several commercially available fixators were tested according to applicable sections of the American Society for Testing and Materials F1541 standard protocol in axial, medial-lateral, and anterior-posterior orientations. The primary outcomes measured included failure load, safe load, rigidity, and yield load. The mean differences between experimental and control groups were calculated using one-way analysis of variance and Tukey tests. RESULTS: The 20% infill 3D-printed construct showed poor performance compared with commercially available external fixators in all testing conditions and across most variables. The 100% infill 3D-printed construct was comparable with or superior to all commercially available devices in most testing conditions. The cost for printing a single 3D-printed 100% infill external fixator was $14.49 (United States Dollar). DISCUSSION: This study demonstrates that a low-cost desktop 3D printer can create an entirely 3D-printed external fixator that resists clinically relevant forces similar to medical-grade industry-standard external fixators. Therefore, there is potential for customizable and low-cost external fixators to be manufactured with desktop 3D printing for use in remote areas and other resource-constrained environments for fracture care.


Assuntos
Fraturas Ósseas , Ortopedia , Criança , Humanos , Estados Unidos , Fixadores Externos , Próteses e Implantes , Impressão Tridimensional
18.
Injury ; 55(3): 111341, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38244250

RESUMO

Bone transport is one of several techniques that has been proven to be effective in addressing critical bone loss. While it was first described over 100 years ago, modifications to this technique coupled with advances in technology have allowed us to perform bone transport with higher success rates and reduced complication rates. Modern techniques of bone transport aim to shorten the duration of time an external fixator is utilized to reduce its associated complications and burden to patients. We present an update on modern techniques of bone transport for critical size defects and methods to shorten the external fixation time.


Assuntos
Técnica de Ilizarov , Osteogênese por Distração , Fraturas da Tíbia , Humanos , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia , Resultado do Tratamento , Fixadores Externos , Osteogênese por Distração/métodos , Estudos Retrospectivos
19.
Injury ; 55(3): 111349, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38277877

RESUMO

PURPOSE: Sierra Leone is a low-income country located on the west coast of Africa where the majority of the population does not have free access to emergency medical and surgical services, the principal cause of open tibia fractures is motorcycle collision. Open fractures of the middle and distal third of the tibial segments, particularly those classified as type III B, represent a challenge for orthopedic surgeons because of the loss of soft tissue coverage. The Reverse Sural Fasciocutaneous Flap (RSFF) has been shown to be an ideal and reproducible option for the treatment of soft tissue defects. The main aim of this study was to demonstrate the experience in Resource Limited Settings (RLS) by means of a short series of the efficacy of using a combination of external fixation and RSFF in the treatment of grade III B open tibia fractures where plastic surgeons were not available. METHODS: This retrospective, descriptive, and non-experimental study included 8 patients who underwent surgical intervention between September 2020 and September 2021. RESULTS: The skin defects were of various sizes; the smallest size was 4 × 7 cm, and the biggest size of 12 × 18 cm. We obtained a success rate in seven of the eight cases. CONCLUSIONS: External fixation and reverse sural fasciocutaneous sural flap are excellent therapeutic options for the treatment of open grade III B diaphyseal and metaphyseal distal tibial fractures.


Assuntos
Fraturas Expostas , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Fraturas da Tíbia , Humanos , Região de Recursos Limitados , Fixadores Externos , Estudos Retrospectivos , Fixação de Fratura , Fraturas da Tíbia/cirurgia , Resultado do Tratamento , Fraturas Expostas/cirurgia , Lesões dos Tecidos Moles/cirurgia
20.
J Foot Ankle Surg ; 63(2): 237-240, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38043598

RESUMO

Charcot reconstruction with static external fixation provides stability in deformity correction. Concern for pin site health remains forefront to prevent premature fixator removal should infection develop. While previous investigations examined a spectrum of pin care protocol with a similar variation in outcomes, this study assesses results following a "no care pin care" routine. A retrospective analysis of patients with Charcot neuroarthropathy treated with static external fixation was performed where all pin sites were dressed using a chlorhexidine-soaked sponge without postoperative maintenance. Demographics, reconstruction-specific, and postoperative variables including pin site irritation, pin site infection, and pin tract infection were collected through frame removal. A comparison between uncomplicated and complicated pin sites was made. Statistical significance was set as p ≤ .05. Among 85 patients and their respective pin holes that posed potential spots of infection, 6 (7%) experienced pin site irritation and 5 (6%) experienced pin site infection. Moreover, 2 (2%) experienced a pin tract infection requiring removal. Out of the 768 wires/half-pins 2 (0.3%) were removed. There existed no statistically significant predictors of pin site irritation/infection other than age (p = .03). "No care pin care" proves an effective means at pin site care following static external fixation in Charcot reconstruction. Limited maintenance reduces the postoperative burden on providers and patients.


Assuntos
Fixadores Externos , Fixação de Fratura , Humanos , Fixadores Externos/efeitos adversos , Estudos Retrospectivos , Fixação de Fratura/efeitos adversos , Pinos Ortopédicos , Fios Ortopédicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...