Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.842
Filtrar
1.
Med Eng Phys ; 126: 104143, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38621845

RESUMO

Primary implant stability, which refers to the stability of the implant during the initial healing period is a crucial factor in determining the long-term success of the implant and lays the foundation for secondary implant stability achieved through osseointegration. Factors affecting primary stability include implant design, surgical technique, and patient-specific factors like bone quality and morphology. In vivo, the cyclic nature of anatomical loading puts osteosynthesis locking screws under dynamic loads, which can lead to the formation of micro cracks and defects that slowly degrade the mechanical connection between the bone and screw, thus compromising the initial stability and secondary stability of the implant. Monotonic quasi-static loading used for testing the holding capacity of implanted screws is not well suited to capture this behavior since it cannot capture the progressive deterioration of peri­implant bone at small displacements. In order to address this issue, this study aims to determine a critical point of loss of primary implant stability in osteosynthesis locking screws under cyclic overloading by investigating the evolution of damage, dissipated energy, and permanent deformation. A custom-made test setup was used to test implanted 2.5 mm locking screws under cyclic overloading test. For each loading cycle, maximum forces and displacement were recorded as well as initial and final cycle displacements and used to calculate damage and energy dissipation evolution. The results of this study demonstrate that for axial, shear, and mixed loading significant damage and energy dissipation can be observed at approximately 20 % of the failure force. Additionally, at this load level, permanent deformations on the screw-bone interface were found to be in the range of 50 to 150 mm which promotes osseointegration and secondary implant stability. This research can assist surgeons in making informed preoperative decisions by providing a better understanding of the critical point of loss of primary implant stability, thus improving the long-term success of the implant and overall patient satisfaction.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Humanos , Fenômenos Biomecânicos , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Fenômenos Mecânicos
2.
Sci Rep ; 14(1): 7794, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565625

RESUMO

In this study, a commercial dental resin was reinforced by SiO2 nanoparticles (NPs) with different concentrations to enhance its mechanical functionality. The material characterization and finite element analysis (FEA) have been performed to evaluate the mechanical properties. Wedge indentation and 3-point bending tests were conducted to assess the mechanical behavior of the prepared nanocomposites. The results revealed that the optimal content of NPs was achieved at 1% SiO2, resulting in a 35% increase in the indentation reaction force. Therefore, the sample containing 1% SiO2 NPs was considered for further tests. The morphology of selected sample was examined using field emission scanning electron microscopy (FE-SEM), revealing the homogeneous dispersion of SiO2 NPs with minimal agglomeration. X-ray diffraction (XRD) was employed to investigate the crystalline structure of the selected sample, indicating no change in the dental resin state upon adding SiO2 NPs. In the second part of the study, a novel approach called iterative FEA, supported by the experiment wedge indentation test, was used to determine the mechanical properties of the 1% SiO2-dental resin. Subsequently, the accurately determined material properties were assigned to a dental crown model to virtually investigate its behavior under oblique loading. The virtual test results demonstrated that most microcracks initiated from the top of the crown and extended through its thickness.


Assuntos
Nanopartículas , Dióxido de Silício , Dióxido de Silício/química , Resinas Compostas/química , Análise de Elementos Finitos , Nanopartículas/química , Fenômenos Mecânicos , Teste de Materiais
3.
J Vis Exp ; (205)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38587397

RESUMO

High-speed atomic force microscopy (HS-AFM) is a popular molecular imaging technique for visualizing single-molecule biological processes in real-time due to its ability to image under physiological conditions in liquid environments. The photothermal off-resonance tapping (PORT) mode uses a drive laser to oscillate the cantilever in a controlled manner. This direct cantilever actuation is effective in the MHz range. Combined with operating the feedback loop on the time domain force curve rather than the resonant amplitude, PORT enables high-speed imaging at up to ten frames per second with direct control over tip-sample forces. PORT has been shown to enable imaging of delicate assembly dynamics and precise monitoring of patterns formed by biomolecules. Thus far, the technique has been used for a variety of dynamic in vitro studies, including the DNA 3-point-star motif assembly patterns shown in this work. Through a series of experiments, this protocol systematically identifies the optimal imaging parameter settings and ultimate limits of the HS-PORT AFM imaging system and how they affect biomolecular assembly processes. Additionally, it investigates potential undesired thermal effects induced by the drive laser on the sample and surrounding liquid, particularly when the scanning is limited to small areas. These findings provide valuable insights that will drive the advancement of PORT mode's application in studying complex biological systems.


Assuntos
Fenômenos Mecânicos , Nanotecnologia , Microscopia de Força Atômica/métodos , Imagem Molecular , DNA
4.
Nat Commun ; 15(1): 3019, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589360

RESUMO

Catch bonds are a rare class of protein-protein interactions where the bond lifetime increases under an external pulling force. Here, we report how modification of anchor geometry generates catch bonding behavior for the mechanostable Dockerin G:Cohesin E (DocG:CohE) adhesion complex found on human gut bacteria. Using AFM single-molecule force spectroscopy in combination with bioorthogonal click chemistry, we mechanically dissociate the complex using five precisely controlled anchor geometries. When tension is applied between residue #13 on CohE and the N-terminus of DocG, the complex behaves as a two-state catch bond, while in all other tested pulling geometries, including the native configuration, it behaves as a slip bond. We use a kinetic Monte Carlo model with experimentally derived parameters to simulate rupture force and lifetime distributions, achieving strong agreement with experiments. Single-molecule FRET measurements further demonstrate that the complex does not exhibit dual binding mode behavior at equilibrium but unbinds along multiple pathways under force. Together, these results show how mechanical anisotropy and anchor point selection can be used to engineer artificial catch bonds.


Assuntos
60634 , Fenômenos Mecânicos , Humanos , Anisotropia , Cinética , Bactérias , Ligação Proteica
5.
J Biomech ; 166: 112063, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38564846

RESUMO

Force-sensing insoles are wearable technology that offer an innovative way to measure loading outside of laboratory settings. Few studies, however, have utilized insoles to measure daily loading in real-world settings. This is an ancillary study of a randomized controlled trial examining the effect of weight loss alone, weight loss plus weighted vest, or weight loss plus resistance training on bone health in older adults. The purpose of this ancillary study was to determine the feasibility of using force-sensing insoles to collect daily limb loading metrics, including peak force, impulse, and loading rate. Forty-four participants completed a baseline visit of three, 2-minute walking trials while wearing force-sensing insoles. During month two of the intervention, 37 participants wore insoles for 4 days for 8 waking hours each day. At 6-month follow-up, participants completed three, two-minute walking trials and a satisfaction questionnaire. Criteria for success in feasibility was defined as: a) > 60 % recruitment rate; b) > 80 % adherence rate; c) > 75 % of usable data, and d) > 75 % participant satisfaction. A 77.3 % recruitment rate was achieved, with 44 participants enrolled. Participants wore their insoles an average of 7.4 hours per day, and insoles recorded an average of 5.5 hours per day. Peak force, impulse, and loading rate collected at baseline and follow-up were 100 % usable. During the real-world settings, 87.8 % of data was deemed usable with an average of 1200 min/participant. Lastly, average satisfaction was 80.5 %. These results suggest that force-sensing insoles appears to be feasible to capture real-world limb loading in older adults.


Assuntos
Fenômenos Mecânicos , Caminhada , Humanos , Idoso , Estudos de Viabilidade , Extremidades , Redução de Peso , Sapatos
6.
PLoS One ; 19(4): e0302021, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38625839

RESUMO

Falls among older adults are a costly public health concern. Such falls can be precipitated by balance disturbances, after which a recovery strategy requiring rapid, high force outputs is necessary. Sarcopenia among older adults likely diminishes their ability to produce the forces necessary to arrest gait instability. Age-related changes to tendon stiffness may also delay muscle stretch and afferent feedback and decrease force transmission, worsening fall outcomes. However, the association between muscle strength, tendon stiffness, and gait instability is not well established. Given the ankle's proximity to the onset of many walking balance disturbances, we examined the relation between both plantarflexor strength and Achilles tendon stiffness with walking-related instability during perturbed gait in older and younger adults-the latter quantified herein using margins of stability and whole-body angular momentum including the application of treadmill-induced slip perturbations. Older and younger adults did not differ in plantarflexor strength, but Achilles tendon stiffness was lower in older adults. Among older adults, plantarflexor weakness associated with greater whole-body angular momentum following treadmill-induced slip perturbations. Weaker older adults also appeared to walk and recover from treadmill-induced slip perturbations with more caution. This study highlights the role of plantarflexor strength and Achilles tendon stiffness in regulating lateral gait stability in older adults, which may be targets for training protocols seeking to minimize fall risk and injury severity.


Assuntos
Tendão do Calcâneo , Transtornos Neurológicos da Marcha , Humanos , Idoso , Marcha/fisiologia , Caminhada/fisiologia , Envelhecimento/fisiologia , Fenômenos Mecânicos , Tendão do Calcâneo/fisiologia , Equilíbrio Postural , Fenômenos Biomecânicos
7.
PLoS One ; 19(4): e0299016, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38625886

RESUMO

The measurement of cellular forces, which reflect crucial biological attributes, has the potential to replace conventional cell assessment methods, such as morphology, proliferation, and molecular expression analysis, in medical cell diagnosis and cell culture studies. In medical cell evaluations, force inference techniques have gained prominence due to their non-invasiveness and lack of requirement for specialized equipment. Among those techniques, the method proposed by Ishihara et al., which estimates forces in densely packed cells based only on cell geometry, is a promising method. However, its applicability range of this method has not been fully established. In this study, we employed a two-dimensional vertex model to numerically assess the applicability of this method on homogeneous and heterogeneous cells. Our comparisons between the true values from numerical simulations and the estimated values from the inference method revealed a significant correlation between estimation accuracy and cell roundness in systems of homogeneous cell. Moreover, the method demonstrated efficient force estimations in heterogeneous-cell systems. These findings may be useful when the force inference method is employed to evaluate medical cells.


Assuntos
Fenômenos Mecânicos , Fenômenos Biomecânicos
8.
Nat Commun ; 15(1): 2906, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575578

RESUMO

Mechano-sensitive hair-like sensilla (MSHS) have an ingenious and compact three-dimensional structure and have evolved widely in living organisms to perceive multidirectional mechanical signals. Nearly all MSHS are iontronic or electronic, including their biomimetic counterparts. Here, an all-optical mechano-sensor mimicking MSHS is prototyped and integrated based on a thin-walled glass microbubble as a flexible whispering-gallery-mode resonator. The minimalist integrated device has a good directionality of 32.31 dB in the radial plane of the micro-hair and can detect multidirectional displacements and forces as small as 70 nm and 0.9 µN, respectively. The device can also detect displacements and forces in the axial direction of the micro-hair as small as 2.29 nm and 3.65 µN, respectively, and perceive different vibrations. This mechano-sensor works well as a real-time, directional mechano-sensory whisker in a quadruped cat-type robot, showing its potential for innovative mechano-transduction, artificial perception, and robotics applications.


Assuntos
Robótica , Sensilas , Animais , Cabelo , Fenômenos Mecânicos , Eletrônica
9.
Methods Enzymol ; 694: 83-107, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38492959

RESUMO

Mechanical forces are critical to protein function across many biological contexts-from bacterial adhesion to muscle mechanics and mechanotransduction processes. Hence, understanding how mechanical forces govern protein activity has developed into a central scientific question. In this context, single-molecule magnetic tweezers has recently emerged as a valuable experimental tool, offering the capability to measure single proteins over physiologically relevant forces and timescales. In this chapter, we present a detailed protocol for the assembly and operation of our magnetic tape head tweezers instrument, specifically tailored to investigate protein dynamics. Our instrument boasts a simplified microscope design and incorporates a magnetic tape head as the force-generating apparatus, facilitating precise force control and enhancing its temporal stability, enabling the study of single protein mechanics over extended timescales spanning several hours or even days. Moreover, its straightforward and cost-effective design ensures its accessibility to the wider scientific community. We anticipate that this technique will attract widespread interest within the growing field of mechanobiology and expect that this chapter will provide facilitated accessibility to this technology.


Assuntos
Fenômenos Mecânicos , Mecanotransdução Celular , Proteínas , Magnetismo/métodos , Fenômenos Magnéticos , Pinças Ópticas
10.
J Am Chem Soc ; 146(11): 7266-7273, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38451494

RESUMO

Tension gauge tethers (TGTs), short DNA segments serving as extracellular tension sensors, are instrumental in assessing the tension dynamics in mechanotransduction. These TGTs feature an initial shear-stretch region and an unzip-stretch region. Despite their utility, no theoretical model has been available to estimate their tension-dependent lifetimes [τ(f)], restricting insights from cellular mechanotransduction experiments. We have now formulated a concise expression for τ(f) of TGTs, accommodating contributions from both stretch regions. Our model uncovers a tension-dependent energy barrier shift occurring when tension surpasses a switching force of approximately 13 pN for the recently developed TGTs, greatly influencing τ(f) profiles. Experimental data from several TGTs validated our model. The calibrated expression can predict τ(f) of TGTs at 37 °C based on their sequences with minor fold changes, supporting future applications of TGTs.


Assuntos
Fenômenos Mecânicos , Mecanotransdução Celular , DNA , Estresse Mecânico
11.
J Am Chem Soc ; 146(11): 7233-7242, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38451498

RESUMO

The T cell membrane is studded with >104 T cell receptors (TCRs) that are used to scan target cells to identify short peptide fragments associated with viral infection or cancerous mutation. These peptides are presented as peptide-major-histocompatibility complexes (pMHCs) on the surface of virtually all nucleated cells. The TCR-pMHC complex forms at cell-cell junctions, is highly transient, and experiences mechanical forces. An important question in this area pertains to the role of the force duration in immune activation. Herein, we report the development of force probes that autonomously terminate tension within a time window following mechanical triggering. Force-induced site-specific enzymatic cleavage (FUSE) probes tune the tension duration by controlling the rate of a force-triggered endonuclease hydrolysis reaction. This new capability provides a method to study how the accumulated force duration contributes to T cell activation. We screened DNA sequences and identified FUSE probes that disrupt mechanical interactions with F > 7.1 piconewtons (pN) between TCRs and pMHCs. This rate of disruption, or force lifetime (τF), is tunable from tens of minutes down to 1.9 min. T cells challenged with FUSE probes with F > 7.1 pN presenting cognate antigens showed up to a 23% decrease in markers of early activation. FUSE probes with F > 17.0 pN showed weaker influence on T cell triggering further showing that TCR-pMHC with F > 17.0 pN are less frequent compared to F > 7.1 pN. Taken together, FUSE probes allow a new strategy to investigate the role of force dynamics in mechanotransduction broadly and specifically suggest a model of serial mechanical engagement boosting TCR activation.


Assuntos
Mecanotransdução Celular , Receptores de Antígenos de Linfócitos T , Receptores de Antígenos de Linfócitos T/metabolismo , Linfócitos T , Ativação Linfocitária , Fenômenos Mecânicos , Peptídeos/química , Ligação Proteica
12.
Sensors (Basel) ; 24(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38544203

RESUMO

This study assesses the agreement of compressive and shear force estimates at the L5-S1 joint using inertial motion capture (IMC) within a musculoskeletal simulation model during manual lifting tasks, compared against a top-down optical motion capture (OMC)-based model. Thirty-six participants completed lifting and lowering tasks while wearing a modified Plug-in Gait marker set for the OMC and a full-body IMC set-up consisting of 17 sensors. The study focused on tasks with variable load weights, lifting heights, and trunk rotation angles. It was found that the IMC system consistently underestimated the compressive forces by an average of 34% (975.16 N) and the shear forces by 30% (291.77 N) compared with the OMC system. A critical observation was the discrepancy in joint angle measurements, particularly in trunk flexion, where the IMC-based model underestimated the angles by 10.92-11.19 degrees on average, with the extremes reaching up to 28 degrees. This underestimation was more pronounced in tasks involving greater flexion, notably impacting the force estimates. Additionally, this study highlights significant differences in the distance from the spine to the box during these tasks. On average, the IMC system showed an 8 cm shorter distance on the X axis and a 12-13 cm shorter distance on the Z axis during lifting and lowering, respectively, indicating a consistent underestimation of the segment length compared with the OMC system. These discrepancies in the joint angles and distances suggest potential limitations of the IMC system's sensor placement and model scaling. The load weight emerged as the most significant factor affecting force estimates, particularly at lower lifting heights, which involved more pronounced flexion movements. This study concludes that while the IMC system offers utility in ergonomic assessments, sensor placement and anthropometric modeling accuracy enhancements are imperative for more reliable force and kinematic estimations in occupational settings.


Assuntos
Vértebras Lombares , Captura de Movimento , Humanos , Movimento , Fenômenos Mecânicos , Fenômenos Biomecânicos , Remoção
13.
J Mol Graph Model ; 129: 108749, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38442439

RESUMO

Mechanical properties of proteins that have a crucial effect on their operation. This study used a molecular dynamics simulation package to investigate rubredoxin unfolding on the atomic scale. Different simulation techniques were applied, and due to the dissociation of covalent/hydrogen bonds, this protein demonstrates several intermediate states in force-extension behavior. A conceptual model based on the cohesive finite element method was developed to consider the intermediate damages that occur during unfolding. This model is based on force-displacement curves derived from molecular dynamics results. The proposed conceptual model is designed to accurately identify bond rupture points and determine the associated forces. This is achieved by conducting a thorough comparison between molecular dynamics and cohesive finite element results. The utilization of a viscoelastic cohesive zone model allows for the consideration of loading rate effects. This rate-dependent model can be further developed and integrated into the multiscale modeling of large assemblies of metalloproteins, providing a comprehensive understanding of mechanical behavior while maintaining a reduced computational cost.


Assuntos
Metaloproteínas , Rubredoxinas , Rubredoxinas/química , Simulação de Dinâmica Molecular , Fenômenos Mecânicos , Ligação de Hidrogênio
14.
Nat Commun ; 15(1): 2748, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553446

RESUMO

Biopolymer topology is critical for determining interactions inside cell environments, exemplified by DNA where its response to mechanical perturbation is as important as biochemical properties to its cellular roles. The dynamic structures of chiral biopolymers exhibit complex dependence with extension and torsion, however the physical mechanisms underpinning the emergence of structural motifs upon physiological twisting and stretching are poorly understood due to technological limitations in correlating force, torque and spatial localization information. We present COMBI-Tweez (Combined Optical and Magnetic BIomolecule TWEEZers), a transformative tool that overcomes these challenges by integrating optical trapping, time-resolved electromagnetic tweezers, and fluorescence microscopy, demonstrated on single DNA molecules, that can controllably form and visualise higher order structural motifs including plectonemes. This technology combined with cutting-edge MD simulations provides quantitative insight into complex dynamic structures relevant to DNA cellular processes and can be adapted to study a range of filamentous biopolymers.


Assuntos
DNA , Fenômenos Mecânicos , DNA/química , Biopolímeros , Microscopia de Fluorescência , Pinças Ópticas , Fenômenos Magnéticos
15.
J Biomech ; 166: 112051, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38503062

RESUMO

Measuring or estimating the forces acting on the human body during movement is critical for determining the biomechanical aspects relating to injury, disease and healthy ageing. In this study we examined whether quantifying whole-body motion (segmental accelerations) using a commercial markerless motion capture system could accurately predict three-dimensional ground reaction force during a diverse range of human movements: walking, running, jumping and cutting. We synchronously recorded 3D ground reaction forces (force instrumented treadmill or in-ground plates) with high-resolution video from eight cameras that were spatially calibrated relative to a common coordinate system. We used a commercially available software to reconstruct whole body motion, along with a geometric skeletal model to calculate the acceleration of each segment and hence the whole-body centre of mass and ground reaction force across each movement task. The average root mean square difference (RMSD) across all three dimensions and all tasks was 0.75 N/kg, with the maximum average RMSD being 1.85 N/kg for running vertical force (7.89 % of maximum). There was very strong agreement between peak forces across tasks, with R2 values indicating that the markerless prediction algorithm was able to predict approximately 95-99 % of the variance in peak force across all axes and movements. The results were comparable to previous reports using whole-body marker-based approaches and hence this provides strong proof-of-principle evidence that markerless motion capture can be used to predict ground reaction forces and therefore potentially assess movement kinetics with limited requirements for participant preparation.


Assuntos
Captura de Movimento , Corrida , Humanos , Fenômenos Biomecânicos , Fenômenos Mecânicos , Movimento
16.
Int J Pharm ; 655: 124049, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38537921

RESUMO

In in-process quality monitoring for Continuous Manufacturing (CM) and Critical Quality Attributes (CQA) assessment for Real-time Release (RTR) testing, ultrasonic characterization is a critical technology for its direct, non-invasive, rapid, and cost-effective nature. In quality evaluation with ultrasound, relating a pharmaceutical tablet's ultrasonic response to its defect state and quality parameters is essential. However, ultrasonic CQA characterization requires a robust mathematical model, which cannot be obtained with traditional first principles-based modeling approaches. Machine Learning (ML) using experimental data is emerging as a critical analytical tool for overcoming such modeling challenges. In this work, a novel Deep Neural Network-based ML-driven Non-Destructive Evaluation (ML-NDE) modeling framework is developed, and its effectiveness for extracting and predicting three CQAs, namely defect states, compression force levels, and amounts of disintegrant, is demonstrated. Using a robotic tablet handling experimental rig, each attribute's distinct waveform dataset was acquired and utilized for training, validating, and testing the respective ML models. This study details an advanced algorithmic quality assessment framework for pharmaceutical CM in which automated RTR testing is expected to be critical in developing cost-effective in-process real-time monitoring systems. The presented ML-NDE approach has demonstrated its effectiveness through evaluations with separate (unused) test datasets.


Assuntos
Tecnologia Farmacêutica , Ultrassom , Fenômenos Mecânicos , Pressão , Comprimidos
17.
J Biomech ; 166: 112044, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38461742

RESUMO

Low-cost and field-viable methods that can simultaneously assess external kinetics and kinematics are necessary to enhance field-based biomechanical monitoring. The aim of this study was to determine the accuracy and usability of ground reaction force (GRF) profiles estimated from segmental kinematics, measured with OpenCap (a low-cost markerless motion-capture system), during common jumping movements. Full-body segmental kinematics were recorded for fifteen recreational athletes performing countermovement, squat, bilateral drop, and unilateral drop jumps, and used to estimate vertical GRFs with a mechanics-based method. Eleven distinct performance-, fatigue-, or injury-related GRF variables were then validated against a gold-standard force platform. Across jumping movements, a total of six and three GRF variables were estimated with a bias or limits of agreement <5 % respectively. Bias and limits of agreement were between 5 and 15 % for seventeen and nineteen variables respectively. Moreover, we show that estimated force variables with a bias <15 % can adequately assess the within-athlete changes in GRF variables between jumping conditions (arm swing or leg dominance). These findings indicate that using a low-cost and field-viable markerless motion capture system (OpenCap) to estimate and assess GRF profiles during common jumping movements is approaching acceptable limits of accuracy. The presented method can be used to monitor force variables of interest and examine underlying segmental kinematics. This application is a jump towards researchers and sports practitioners performing biomechanical monitoring of jumping efficiently, regularly, and extensively in field settings.


Assuntos
Fenômenos Mecânicos , Esportes , Humanos , Fenômenos Biomecânicos , Movimento , Postura
18.
PLoS One ; 19(3): e0299542, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38478544

RESUMO

The potential application of flapping wings in micro-aerial vehicles is gaining interest due to their ability to generate high lift even in confined spaces. Most studies in the past have investigated hovering wings as well as those flapping near solid surfaces. However, the presence of surface tension at the water-air interface and the ability of the water surface to move might differentiate its response to the proximity of wings, compared to that of solid surfaces. Motivated by underwater, amphibian robots and several underwater experimental studies on flapping wings, our study investigated the effects of the proximity of flapping wings to the water surface at low Reynolds numbers (Re = 3400). Experiments were performed on a rectangular wing in a water tank with prescribed flapping kinematics and the aerodynamic forces were measured. The effects of surface proximity on the wing in its both upright and inverted orientations were studied. Broadly, the mean lift and drag coefficients in both orientations decreased significantly (by up to 60%) as the distance from the water surface was increased. In the case of the upright orientation, the mean lift coefficient was slightly decreased very close to the water surface with its peak being observed at the normalized clearance of [Formula: see text]. Overall, the study revealed an enhancement in the aerodynamic forces closer to the water surface.


Assuntos
Voo Animal , Asas de Animais , Animais , Asas de Animais/fisiologia , Voo Animal/fisiologia , Modelos Biológicos , Fenômenos Mecânicos , Fenômenos Biomecânicos
19.
PLoS One ; 19(3): e0299426, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38478553

RESUMO

In solving the whole process of interaction between soft rock and yielding support in high-stress environments in tunnels using mechanical analysis methods, it is challenging to simultaneously satisfy both displacement coordination and static equilibrium at the contact surface between the rock and the support structure. This paper, based on the mechanical analysis of rock and rigid support, considers the impact of the circumferential installation of yielding elements on radial displacement, and proposes displacement approximation and support force approximation methods using displacement coordination and static equilibrium as approximation conditions. The study fits curves of numerical simulation results and laboratory test results of yielding elements, and attempts to directly use the laboratory test data set of yielding elements as computational data. By calculating two circular tunnel examples and comparing the effects of the trisection method, bisection method, and substitution method on the convergence of the displacement approximation method, the effectiveness of the methods proposed in this paper is verified. The research results show that the two approximation algorithms proposed in this paper have good accuracy and reliability in calculating the relative displacement of rock and yielding support structure contact surfaces, and the support force of yielding support. The bisection method outperforms the trisection and substitution methods in terms of stability and convergence. However, there are certain limitations in this study, such as the effectiveness of the algorithm may be influenced by geological conditions; the complexity of actual geological conditions may exceed the assumptions of the current rock-support mechanical analysis model.


Assuntos
Algoritmos , Fenômenos Mecânicos , Reprodutibilidade dos Testes , Simulação por Computador
20.
Sci Rep ; 14(1): 6397, 2024 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493233

RESUMO

Modular hip implants allow intra-operative adjustments for patient-specific customization and targeted replacement of damaged elements without full implant extraction. However, challenges arise from relative micromotions between components, potentially leading to implant failure due to cytotoxic metal debris. In this study magnitude and directions of micromotions at the taper junction were estimated, aiming to understand the effect of variations in head size and neck length. Starting from a reference configuration adhering to the 12/14 taper standard, six additional implant configurations were generated by varying the head size and/or neck length. A musculoskeletal multibody model of a prothesized lower limb was developed to estimate hip contact force and location during a normal walking task. Following the implant assembly, the multibody-derived loads were imposed as boundary conditions in a finite element analysis to compute the taper junction micromotions as the relative slip between the contacting surfaces. Results highlighted the L-size head as the most critical configuration, indicating a 2.81 µm relative slip at the mid-stance phase. The proposed approach enables the investigation of geometric variations in implants under accurate load conditions, providing valuable insights for designing less risky prostheses and informing clinical decision-making processes.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Desenho de Prótese , Fenômenos Mecânicos , Metais , Corrosão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...