Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.671
Filtrar
1.
BMC Anesthesiol ; 24(1): 128, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575875

RESUMO

BACKGROUND: Elevated central venous pressure (CVP) is deemed as a sign of right ventricular (RV) dysfunction. We aimed to characterize the echocardiographic features of RV in septic patients with elevated CVP, and quantify associations between RV function parameters and 30-day mortality. METHODS: We retrospectively reviewed a cohort of septic patients with CVP ≥ 8 mmHg in a tertiary hospital intensive care unit. General characteristics and echocardiographic parameters including tricuspid annular plane systolic excursion (TAPSE), pulmonary vascular resistance (PVR) as well as prognostic data were collected. Associations between RV function parameters and 30-day mortality were assessed using Cox regression models. RESULTS: Echocardiography was performed in 244 septic patients with CVP ≥ 8 mmHg. Echocardiographic findings revealed that various types of abnormal RV function can occur individually or collectively. Prevalence of RV systolic dysfunction was 46%, prevalence of RV enlargement was 34%, and prevalence of PVR increase was 14%. In addition, we collected haemodynamic consequences and found that prevalence of systemic venous congestion was 16%, prevalence of RV-pulmonary artery decoupling was 34%, and prevalence of low cardiac index (CI) was 23%. The 30-day mortality of the enrolled population was 24.2%. In a Cox regression analysis, TAPSE (HR:0.542, 95% CI:0.302-0.972, p = 0.040) and PVR (HR:1.384, 95% CI:1.007-1.903, p = 0.045) were independently associated with 30-day mortality. CONCLUSIONS: Echocardiographic findings demonstrated a high prevalence of RV-related abnormalities (RV enlargement, RV systolic dysfunction and PVR increase) in septic patients with elevated CVP. Among those echocardiographic parameters, TAPSE and PVR were independently associated with 30-day mortality in these patients.


Assuntos
Sepse , Disfunção Ventricular Direita , Humanos , Pressão Venosa Central , Ventrículos do Coração/diagnóstico por imagem , Estudos Retrospectivos , Ecocardiografia , Hipertrofia Ventricular Direita , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita , Volume Sistólico
2.
Asian J Surg ; 47(1): 477-485, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37438153

RESUMO

BACKGROUND: In the 21st century, 13% of patients undergoing open abdominal surgery, 25% of patients undergoing heart surgery, and 57% of patients admitted to the intensive care unit (ICU) are affected by acute kidney injury (AKI). METHODS: This prospective observational study included patients admitted directly to the ICU between June 2021 and December 2021. RESULTS: A total of 81 patients were enrolled after thoracic and abdominal (non-cardiac) surgery; 36 patients (44.4%) were diagnosed with AKI occurred within 7 days after surgery. Six-hour postoperative central venous pressure(CVP) was a risk factor for AKI in thoracic and abdominal (non-cardiac) postoperative patients (odds ratio [OR], 1.418; 95% confidence intervals [CI], 1.106-1.819; P = 0.006). Six-hour postoperative vein impedance index(VII) and CVP were significantly positively correlated (P = 0.031). The combination of 6-h postoperative VII with CVP (VII ≥0.34, CVP ≥7.5 mmHg) showed an area under the curve (AUC) of 0.787, In the subgroup analysis of patients with 6-h postoperative CVP <7.5 mmHg, there was a significant statistical difference in 6-h postoperative VII between the groups and those without AKI (P = 0.048). At 6-h postoperative CVP <7.5 mmHg, VII of ≥0.44 had a predictive value for AKI after thoracic and abdominal (non-cardiac) surgery, with an AUC of 0.669, a sensitivity of 41.2%, and a specificity of 94.4%. CONCLUSION: Six-hour postoperative CVP combined with VII can better predict the occurrence of AKI occurred within 7 days after thoracic and abdominal (non-cardiac) surgery but cannot predict the severity of AKI.


Assuntos
Injúria Renal Aguda , Procedimentos Cirúrgicos Cardíacos , Humanos , Abdome/cirurgia , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/epidemiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Pressão Venosa Central , Impedância Elétrica , Estudos Prospectivos
4.
J Anesth ; 38(1): 77-85, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38091035

RESUMO

PURPOSE: The purpose of this prospective single blinded randomized controlled trial was to find out whether goal-directed fluid therapy (GDFT) strategy in post-transection period in low central venous pressure (CVP) assisted laparoscopic hepatectomy (LH) has more benefit than traditional fluid strategy. METHODS: Between April 2020 and Dec 2021, patients who were scheduled for laparoscopic liver resection surgery were eligible to participate in the study. Patients were randomly divided into two groups: control group that received traditional fluid strategy in post-transection period in low CVP assisted laparoscopic hepatectomy and GDFT strategy group that received GDFT strategy in post-transection period. The primary outcome parameter is the incidence of postoperative complications. Secondary outcome parameters include perioperative clinical outcomes, postoperative clinical outcomes, length of hospital stay after surgery, postoperative lactic acid, fluids and vasoactive medications during the operation. RESULTS: A total of 159 patients in the control group and 160 patients in the GDFT were included. Two groups had no significant difference in the incidence of postoperative complications including pneumonia (P = 0.34), acute kidney injury (P = 0.72), hepatic insufficiency (P = 0.25), pleural effusion (P = 0.08) and seroperitoneum (P = 1.00), respectively. The amount of perioperative urine output is fewer in GDFT group than in the control group (P = 0.0354), while other perioperative variables and postoperative variables were comparable between two groups. CONCLUSIONS: The results show the implementation of GDFT strategy is not associated with fewer postoperative complications. GDFT strategy did not result in improved outcomes in low CVP-assisted laparoscopic hepatectomy.


Assuntos
Hepatectomia , Laparoscopia , Humanos , Pressão Venosa Central , Objetivos , Estudos Prospectivos , Hidratação/métodos , Complicações Pós-Operatórias/epidemiologia
5.
Artigo em Inglês | MEDLINE | ID: mdl-38082590

RESUMO

The right internal jugular vein is connected to the right atrium of the heart via the superior vena cava, and consequently its pressure, known as the jugular venous pressure or the jugular venous pulse (JVP), is an important indicator of cardiac function. The JVP can be estimated visually from the neck but it is rather difficult and imprecise. In this article we propose a method to measure the JVP using a motion sensor patch attached to the neck. The JVP signal was extracted from the sensor's 3-axes gyroscope signal and aligned with simultaneously measured ECG and seismocardiogram signals.The method was tested on 20 healthy subjects. The timings of the characteristic JVP waves were compared with the ECG R peaks and seismocardiogram heart sounds S1 and S2. The JVP was reliably measured from 18 subjects with all three waves identified. The timings of the waves were also physiologically plausible when compared to the ECG R peak and the heart sounds. Importantly, the JVP was also found to modulate with respiration, further indicating that the measured signal was indeed the JVP and not the carotid pulse.The results show that the JVP can be measured with a wearable patch-like device registering the delicate motions of the right internal jugular vein. The method has potential to be developed into a clinical tool to measure cardiac health in diseases such as heart failure and chronic obstructive pulmonary disease (COPD).Clinical relevance-The developed method could enable an affordable measurement of clinically important cardiac parameter, jugular venous pulse, as a part of a routine examination.


Assuntos
Insuficiência Cardíaca , Veia Cava Superior , Humanos , Fenômenos Fisiológicos Cardiovasculares , Pressão Venosa Central/fisiologia , Átrios do Coração
6.
Postgrad Med J ; 99(1178): 1280-1286, 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37794600

RESUMO

BACKGROUND: Controlled low central venous pressure (CLCVP) technique has been extensively validated in clinical practices to decrease intraoperative bleeding during liver resection process; however, no studies to date have attempted to propose a scoring method to better understand what risk factors might still be responsible for bleeding when CLCVP technique was implemented. METHODS: We aimed to use machine learning to develop a model for detecting the risk factors of major bleeding in patients who underwent liver resection using CLCVP technique. We reviewed the medical records of 1077 patients who underwent liver surgery between January 2017 and June 2020. We evaluated the XGBoost model and logistic regression model using stratified K-fold cross-validation (K = 5), and the area under the receiver operating characteristic curve, the recall rate, precision rate, and accuracy score were calculated and compared. The SHapley Additive exPlanations was employed to identify the most influencing factors and their contribution to the prediction. RESULTS: The XGBoost classifier with an accuracy of 0.80 and precision of 0.89 outperformed the logistic regression model with an accuracy of 0.76 and precision of 0.79. According to the SHapley Additive exPlanations summary plot, the top six variables ranked from most to least important included intraoperative hematocrit, surgery duration, intraoperative lactate, preoperative hemoglobin, preoperative aspartate transaminase, and Pringle maneuver duration. CONCLUSIONS: Anesthesiologists should be aware of the potential impact of increased Pringle maneuver duration and lactate levels on intraoperative major bleeding in patients undergoing liver resection with CLCVP technique.   What is already known on this topic-Low central venous pressure technique has already been extensively validated in clinical practices, with no prediction model for major bleeding. What this study adds-The XGBoost classifier outperformed logistic regression model for the prediction of major bleeding during liver resection with low central venous pressure technique. How this study might affect research, practice, or policy-anesthesiologists should be aware of the potential impact of increased PM duration and lactate levels on intraoperative major bleeding in patients undergoing liver resection with CLCVP technique.


Assuntos
Hemorragia , Ácido Láctico , Humanos , Pressão Venosa Central , Fatores de Risco , Aprendizado de Máquina , Fígado
7.
Exp Physiol ; 108(12): 1560-1568, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37824038

RESUMO

Compression sonography has been proposed as a method for non-invasive measurement of venous pressures during spaceflight, but initial reports of venous pressure measured by compression ultrasound conflict with prior reports of invasively measured central venous pressure (CVP). The aim of this study is to determine the agreement of compression sonography of the internal jugular vein (IJVP) with invasive measures of CVP over a range of pressures relevant to microgravity exposure. Ten healthy volunteers (18-55 years, five female) completed two 3-day sessions of supine bed rest to simulate microgravity. IJVP and CVP were measured in the seated position, and in the supine position throughout 3 days of bed rest. The range of CVP recorded was in line with previous reports of CVP during changes in posture on Earth and in microgravity. The correlation between IJVP and CVP was poor when measured during spontaneous breathing (r = 0.29; R2  = 0.09; P = 0.0002; standard error of the estimate (SEE) = 3.0 mmHg) or end-expiration CVP (CVPEE ; r = 0.19; R2  = 0.04; P = 0.121; SEE = 3.0 mmHg). There was a modest correlation between the change in CVP and the change in IJVP for both spontaneous ΔCVP (r = 0.49; R2  = 0.24; P < 0.0001) and ΔCVPEE (r = 0.58; R2  = 0.34; P < 0.0001). Bland-Altman analysis of IJVP revealed a large positive bias compared to spontaneous breathing CVP (3.6 mmHg; SD = 4.0; CV = 85%; P < 0.0001) and CVPEE (3.6 mmHg; SD = 4.2; CV = 84%; P < 0.0001). Assessment of absolute IJVP via compression sonography correlated poorly with direct measurements of CVP by invasive catheterization over a range of venous pressures that are physiologically relevant to spaceflight. However, compression sonography showed modest utility for tracking changes in venous pressure over time. NEW FINDINGS: What is the central question of this study? Compression sonography has been proposed as a novel method for non-invasive measurement of venous pressures during spaceflight. However, the accuracy has not yet been confirmed in the range of CVP experienced by astronauts during spaceflight. What is the main finding and its importance? Our data show that compression sonography of the internal jugular vein correlates poorly with direct measurement of central venous pressures in a range that is physiologically relevant to spaceflight. However, compression sonography showed modest utility for tracking changes in venous pressure over time.


Assuntos
Repouso em Cama , Veias Jugulares , Humanos , Feminino , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/fisiologia , Pressão Venosa , Pressão Venosa Central/fisiologia , Ultrassonografia
8.
Am J Emerg Med ; 74: 146-151, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37837823

RESUMO

PURPOSE: This study's objective was to investigate the association between exposure to different intensities of central venous pressure (CVP) over time in patients with septic shock with 28-day mortality and acute kidney injury (AKI). MATERIALS AND METHODS: We obtained data from the AmsterdamUMCdb, which includes data on patients ≥18 years old with septic shock undergoing CVP monitoring. The primary outcome was mortality by day 28. Piecewise exponential additive mixed models were used to estimate the strength of the association over time. RESULTS: 9668 patients were included in the study. They exhibited 8.2% overall mortality at 28 days and 41.1% AKI incidence. Daily time-weighted average CVP was strongly associated with increased mortality at 28 days, primarily within 24 h of ICU admission. The mortality rate of patients was lowest when the CVP was 6-12 cmH2O. When the time of high CVP (TWA-CVP >12 cmH2O) exposure within the first 24 h was >5 h, the risk of death increased by 2.69-fold. Additionally, patients exposed to high CVP had a significantly increased risk of developing AKI. CONCLUSIONS: The optimal CVP range for patients with septic shock within 24 h of ICU admission is 6-12 cmH2O. Mortality increased when patients were exposed to high CVP for >5 h.


Assuntos
Injúria Renal Aguda , Choque Séptico , Humanos , Adolescente , Pressão Venosa Central , Estudos Retrospectivos , Injúria Renal Aguda/etiologia , Hospitalização
9.
Fluids Barriers CNS ; 20(1): 58, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37533133

RESUMO

INTRODUCTION: Optimal shunt-based hydrocephalus treatments are heavily influenced by dynamic pressure behaviors between proximal and distal ends of shunt catheters. Posture-dependent craniospinal, arterial, venous, and abdominal dynamics thereby play an essential role. METHODS: An in-vivo ovine trial (n = 6) was conducted to evaluate communication between craniospinal, arterial, venous, and abdominal dynamics. Tilt-testing was performed between -13° and + 13° at 10-min intervals starting and ending at 0° prone position. Mean pressure, pulse pressure, and Pearson correlation (r) to the respective angle were calculated. Correlations are defined as strong: |r|≥ 0.7, mild: 0.3 <|r|< 0.7, and weak: |r|≤ 0.3. Transfer functions (TFs) between the arterial and adjacent compartments were derived. RESULTS: Strong correlations were observed between posture and: mean carotid/femoral arterial (r = - 0.97, r = - 0.87), intracranial, intrathecal (r = - 0.98, r = 0.94), jugular (r = - 0.95), abdominal cranial, dorsal, caudal, and intravesical pressure (r = - 0.83, r = 0.84, r = - 0.73, r = 0.99) while mildly positive correlation exists between tilt and central venous pressure (r = 0.65). Only dorsal abdominal pulse pressure yielded a significant correlation to tilt (r = 0.21). TFs followed general lowpass behaviors with resonant peaks at 4.2 ± 0.4 and 11.5 ± 1.5 Hz followed by a mean roll-off of - 15.9 ± 6.0 dB/decade. CONCLUSIONS: Tilt-tests with multi-compartmental recordings help elucidate craniospinal, arterial, venous, and abdominal dynamics, which is essential to optimize shunt-based therapy. Results motivate hydrostatic influences on mean pressure, with all pressures correlating to posture, with little influence on pulse pressure. TF results quantify the craniospinal, arterial, venous, and abdominal compartments as compliant systems and help pave the road for better quantitative models of the interaction between the craniospinal and adjacent spaces.


Assuntos
Postura , Animais , Pressão Sanguínea , Pressão Venosa Central , Ovinos
10.
Shock ; 60(2): 190-198, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37548683

RESUMO

ABSTRACT: Objective : The hemodynamic parameters used to accurately predict fluid responsiveness (FR) in spontaneously breathing patients (SB) require specific material and expertise. Measurements of the central venous pressure (CVP) are relatively simple and, importantly, are feasible in many critically ill patients. We analyzed the accuracy of respiration-related variations in CVP (vCVP) to predict FR in SB patients and examined the optimization of its measurement using a standardized, deep inspiratory maneuver. Patients and Methods : We performed a monocentric, prospective, diagnostic evaluation. Spontaneously breathing patients in intensive care units with a central venous catheter were prospectively included. The vCVP was measured while the patient was spontaneously breathing, both with (vCVP-st) and without (vCVP-ns) a standardized inspiratory maneuver, and calculated as: Minimum inspiratory v-wave peak pressure - Maximum expiratory v-wave peak pressure. A passive leg raising-induced increase in the left ventricular outflow tract velocity-time integral ≥10% defined FR. Results : Among 63 patients, 38 (60.3%) presented FR. The vCVP-ns was not significantly different between responders and nonresponders (-4.9 mm Hg [-7.5 to -3.1] vs. -4.1 mm Hg [-5.4 to 2.8], respectively; P = 0.15). The vCVP-st was lower in responders than nonresponders (-9.7 mm Hg [-13.9 to -6.2] vs. -3.6 mm Hg [-10.6 to -1.6], respectively; P = 0.004). A vCVP-st < -4.7 mm Hg predicted FR with 89.5% sensitivity, a specificity of 56.0%, and an area under the receiver operating characteristic curve of 0.72 (95% CI, 0.58 to 0.86) ( P = 0.004). Conclusion : When a central venous catheter is present, elevated values for vCVP-st may be useful to identify spontaneously breathing patients unresponsive to volume expansion. Nevertheless, the necessity of performing a standardized, deep-inspiration maneuver may limit its clinical application.


Assuntos
Hidratação , Hemodinâmica , Humanos , Pressão Venosa Central , Estudos Prospectivos , Hidratação/métodos , Respiração , Volume Sistólico
11.
BMC Anesthesiol ; 23(1): 257, 2023 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-37525100

RESUMO

BACKGROUND: Laparoscopic hepatectomy under low central venous pressure (LCVP) is associated with intraoperative organ hypoperfusion, including cerebral hypoperfusion. We hypothesized that a ventilation strategy designed to achieve targeted mild hypercapnia (TMH) (end-tidal carbon dioxide partial pressure [PetCO2] of 45 ± 5 mmHg) rather than targeted normocapnia (TN) (PetCO2 of 30 ± 5 mmHg) would increase regional cerebral oxygen saturation (rSO2) during laparoscopic hepatectomy under LCVP. METHODS: Eighty patients undergoing laparoscopic hepatectomy under LCVP were randomly divided into the TMH group (n = 40) and the TN group (n = 40). Mechanical ventilation was adjusted to maintain the PetCO2 within the relevant range. Cerebral oxygenation was monitored continuously using the FORE-SIGHT system before anesthetic induction until the patient left the operating room. Patient and surgical characteristics, rSO2, intraoperative hemodynamic parameters (CVP, mean artery blood pressure [MAP], and heart rate), PetCO2, intraoperative blood gas analysis results, and postoperative complications were recorded. RESULTS: No significant differences were observed in CVP, MAP, and heart rate between the two groups during surgery. The rSO2 was significantly lower in the TN group on both the left and right sides during the intraoperative period (P < 0.05), while the TMH group had a stable rSO2. In the TN group, the mean rSO2 decreased most during liver parenchymal transection when compared with the baseline value (P < 0.05). The mean (standard deviation) percentage change in rSO2 from baseline to parenchymal transection was - 7.5% (4.8%) on the left and - 7.1% (4.6%) on the right. The two groups had a similar incidence of postoperative complications (P > 0.05). CONCLUSION: Our findings demonstrate that rSO2 is better maintained during laparoscopic hepatectomy under LCVP when patients are ventilated to a PetCO2 of 45 ± 5 mmHg (TMH) than a PetCO2 of 30 ± 5 mmHg (TN). TRIAL REGISTRATION: ChiCTR2100051130(14/9/2021).


Assuntos
Hipercapnia , Laparoscopia , Humanos , Pressão Venosa Central , Hepatectomia , Estudos Prospectivos , Saturação de Oxigênio , Oxigênio , Complicações Pós-Operatórias
12.
S Afr Fam Pract (2004) ; 65(1): e1-e8, 2023 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-37427779

RESUMO

Central venous access is an important procedure to understand and perform not only in the emergency unit but also for prolonged reliable venous access. All clinicians must be familiar and confident with this procedure. This paper will focus on applied anatomy in respect of common anatomical sites for venous access, the indications, the contraindications, the technique and complications that may arise following the procedure. This article is part of a series on vascular access. We have previously written on the intra osseous procedure and an article on umbilical vein catheterisation will follow.


Assuntos
Cateterismo Venoso Central , Médicos , Humanos , Pressão Venosa Central , Veias Jugulares/anatomia & histologia , Veia Subclávia , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Atenção Primária à Saúde
13.
Paediatr Anaesth ; 33(10): 837-843, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37403751

RESUMO

BACKGROUND: Intravenous administration of highly concentrated and potent drugs at low flow rates is common practice, particularly in critically ill children. Drug delivery during infusion start-up can be considerably delayed by intrinsic factors of syringe infusion pump assemblies. The impact of central venous pressures on the course of start-up fluid delivery of such microinfusions remains unknown. METHODS: Infusion volumes delivered after activation of the start button in a conventional 50 mL syringe infusion pump assembly equilibrated (representing classical in vitro testing) and not equilibrated (representing real clinical conditions) to central venous pressure levels of 0, 10 and 20 mmHg at a set infusion flow rate of 1 mL/h were measured using a fluidic flow sensor. RESULTS: The experimental setup mimicking real life conditions demonstrated considerable differences in fluid delivery during pump start-up depending on central venous pressure. A central venous pressure of 0 mmHg resulted in massive fluid delivery at infusion start-up, while central venous pressure levels of 10 and 20 mmHg resulted in retrograde flows with related mean (95% CI) zero-drug delivery times of 3.22 (2.98-3.46) min and 4.51 (4.33-4.69) min, respectively (p < .0001). CONCLUSION: Depending on central venous pressure level, connection and starting a new syringe pump can result in significant antegrade or retrograde fluid volumes. In clinical practice, this can lead to hemodynamic instability and hence requires clinical alertness. Further research and methods to improve start-up performance in syringe infusion pump systems are desirable.


Assuntos
Bombas de Infusão , Criança , Humanos , Pressão Venosa Central , Preparações Farmacêuticas , Infusões Intravenosas
14.
BMC Anesthesiol ; 23(1): 249, 2023 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-37481588

RESUMO

BACKGROUND: In patients undergoing high-risk surgery, it is recommended to titrate fluid administration using stroke volume or a dynamic variable of fluid responsiveness (FR). However, this strategy usually requires the use of a hemodynamic monitor and/or an arterial catheter. Recently, it has been shown that variations of central venous pressure (ΔCVP) during an alveolar recruitment maneuver (ARM) can predict FR and that there is a correlation between CVP and peripheral venous pressure (PVP). This prospective study tested the hypothesis that variations of PVP (ΔPVP) induced by an ARM could predict FR. METHODS: We studied 60 consecutive patients scheduled for high-risk abdominal surgery, excluding those with preoperative cardiac arrhythmias or right ventricular dysfunction. All patients had a peripheral venous catheter, a central venous catheter and a radial arterial catheter linked to a pulse contour monitoring device. PVP was always measured via an 18-gauge catheter inserted at the antecubital fossa. Then an ARM consisting of a standardized gas insufflation to reach a plateau of 30 cmH2O for 30 s was performed before skin incision. Invasive mean arterial pressure (MAP), pulse pressure, heart rate, CVP, PVP, pulse pressure variation (PPV), and stroke volume index (SVI) were recorded before ARM (T1), at the end of ARM (T2), before volume expansion (T3), and one minute after volume expansion (T4). Receiver-operating curves (ROC) analysis with the corresponding grey zone approach were performed to assess the ability of ∆PVP (index test) to predict FR, defined as an ≥ 10% increase in SVI following the administration of a 4 ml/kg balanced crystalloid solution over 5 min. RESULTS: ∆PVP during ARM predicted FR with an area under the ROC curve of 0.76 (95%CI, 0.63 to 0.86). The optimal threshold determined by the Youden Index was a ∆PVP value of 5 mmHg (95%CI, 4 to 6) with a sensitivity of 66% (95%CI, 47 to 81) and a specificity of 82% (95%CI, 63 to 94). The AUC's for predicting FR were not different between ΔPVP, ΔCVP, and PPV. CONCLUSION: During high-risk abdominal surgery, ∆PVP induced by an ARM can moderately predict FR. Nevertheless, other hemodynamic variables did not perform better.


Assuntos
Cateteres de Demora , Humanos , Estudos Prospectivos , Pressão Venosa , Pressão Sanguínea , Pressão Venosa Central
16.
PLoS One ; 18(6): e0287046, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37310966

RESUMO

BACKGROUND: The mean perfusion pressure (MPP) was recently proposed to personalize tissue perfusion pressure management in critically ill patients. Severe fluctuation in MPP may be associated with adverse outcomes. We sought to determine if higher MPP variability was correlated with increased mortality in critically ill patients with CVP monitoring. METHODS: We designed a retrospective observational study and analyzed data stored in the eICU Collaborative Research Database. Validation test was conducted in MIMIC-III database. The exposure was the coefficient of variation (CV) of MPP in the primary analyses, using the first 24 hours MPP data recorded within 72 hours in the first ICU stay. Primary endpoint was in-hospital mortality. RESULTS: A total of 6,111 patients were included. The in-hospital mortality of 17.6% and the median MPP-CV was 12.3%. Non-survivors had significantly higher MPP-CV than survivors (13.0% vs 12.2%, p<0.001). After accounting for confounders, the highest MPP-CV in decile (CV > 19.2%) were associated with increased risk of hospital mortality compared with those in the fifth and sixth decile (adjusted OR: 1.38, 95% Cl: 1.07-1.78). These relationships remained remarkable in the multiple sensitivity analyses. The validation test with 4,153 individuals also confirmed the results when MPP-CV > 21.3% (adjusted OR: 1.46, 95% Cl: 1.05-2.03). CONCLUSIONS: Severe fluctuation in MPP was associated with increased short-term mortality in critically ill patients with CVP monitoring.


Assuntos
Estado Terminal , Humanos , Mortalidade Hospitalar , Pressão Venosa Central , Perfusão , Correlação de Dados
17.
Am J Gastroenterol ; 118(9): 1684-1687, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37146133

RESUMO

We aimed to compare internal jugular vein and inferior vena cava ultrasonography as predictors of central venous pressure in cirrhotic patients. We performed ultrasound assessments of the internal jugular vein (IJV) and the inferior vena cava and then invasively measured central venous pressure (CVP). We then compared their correlation with CVP and performed area under the receiver operating characteristic curves to determine which had best sensitivity and specificity. IJV cross-sectional area collapsibility index at 30° correlated better with CVP ( r = -0.56, P < 0.001), and an IJV AP-CI at 30° ≤ 24.8% was better at predicting a CVP ≥8 mm Hg, with 100% sensitivity and 97.1% specificity. Thus, IJV point-of-care ultrasound might be superior than inferior vena cava point-of-care ultrasound as a predictor of CVP in cirrhotic patients.


Assuntos
Veias Jugulares , Cirrose Hepática , Humanos , Veias Jugulares/diagnóstico por imagem , Pressão Venosa Central , Sensibilidade e Especificidade , Ultrassonografia , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem
20.
Chin Med Sci J ; 38(2): 117-124, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37050845

RESUMO

Background A simple measurement of central venous pressure (CVP)-mean by the digital monitor display has become increasingly popular. However, the agreement between CVP-mean and CVP-end (a standard method of CVP measurement by analyzing the waveform at end-expiration) is not well determined. This study was designed to identify the relationship between CVP-mean and CVP-end in critically ill patients and to introduce a new parameter of CVP amplitude (ΔCVP= CVPmax - CVPmin) during the respiratory period to identify the agreement/disagreement between CVP-mean and CVP-end.Methods In total, 291 patients were included in the study. CVP-mean and CVP-end were obtained simultaneously from each patient. CVP measurement difference (|CVP-mean - CVP-end|) was defined as the difference between CVP-mean and CVP-end. The ΔCVP was calculated as the difference between the peak (CVPmax) and the nadir value (CVPmin) during the respiratory cycle, which was automatically recorded on the monitor screen. Subjects with |CVP-mean - CVP-end|≥ 2 mmHg were divided into the inconsistent group, while subjects with |CVP-mean - CVP-end| < 2 mmHg were divided into the consistent group.Results ΔCVP was significantly higher in the inconsistent group [7.17(2.77) vs.5.24(2.18), P<0.001] than that in the consistent group. There was a significantly positive relationship between ΔCVP and |CVP-mean - CVP-end| (r=0.283, P <0.0001). Bland-Altman plot showed the bias was -0.61 mmHg with a wide 95% limit of agreement (-3.34, 2.10) of CVP-end and CVP-mean. The area under the receiver operating characteristic curves (AUC) of ΔCVP for predicting |CVP-mean - CVP-end| ≥ 2 mmHg was 0.709. With a high diagnostic specificity, using ΔCVP<3 to detect |CVP-mean - CVP-end| lower than 2mmHg (consistent measurement) resulted in a sensitivity of 22.37% and a specificity of 93.06%. Using ΔCVP>8 to detect |CVP-mean - CVP-end| >8 mmHg (inconsistent measurement) resulted in a sensitivity of 31.94% and a specificity of 91.32%.Conclusions CVP-end and CVP-mean have statistical discrepancies in specific clinical scenarios. ΔCVP during the respiratory period is related to the variation of the two CVP methods. A high ΔCVP indicates a poor agreement between these two methods, whereas a low ΔCVP indicates a good agreement between these two methods.


Assuntos
Respiração , Humanos , Pressão Venosa Central , Curva ROC
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...