pH del agua potable que consumen estudiantes del segundo año de la Carrera de Medicina, Universidad Mayor de San Andrés Gestión 2017 / pH of drinking water that second year students of medicine of the Universidad Mayor de San Andres consume term 2017
Cuad. Hosp. Clín
; 59(2): 36-39, 2018. ilus.
Article
em Es
| LILACS, LIBOCS
| ID: biblio-986472
Biblioteca responsável:
BO138.1
RESUMEN
INTRODUCCIÓN:
El pH es una propiedad básica del agua potable y cuyos valores extremos pueden originar reacciones secundarias dañinas, entendiéndose por agua potable aquel que puede ser consumido sin restricción para el consumo humano,OBJETIVO:
Determinar el valor del pH de agua potable que consumen los estudiantes de segundo año de la carrera de medicina de la Universidad Mayor de San Andrés (UMSA). MATERIAL YMÉTODOS:
Se analizaron 388 muestras de agua potable del domicilio de estudiantes regulares de segundo año cátedra de bioquímica entre los meses de julio y agosto del 2017, realizándose un estudio de tipo descriptivo con un enfoque transeccional.RESULTADOS:
Se obtuvieron los siguientes resultados, 1) la media del pH total fue de 7,24; con x=7,22 en la ciudad de la Paz y x=7,28 en la ciudad de el Alto. 2) en cuanto al sistema de potabilización se obtuvo x=7,34 en la planta el Alto, x=7,21 en la planta de Tilata, x=7,15 en la planta de Achachicala y de x=7,20 en la planta de Pampahasi.CONCLUSIONES:
El pH del agua potable consumida se encontró dentro de parámetros establecidos con un valor medio de 7,24.ABSTRACT
INTRODUCTION:
The pH is a basic property of potable water and whose extreme values may cause harmful secondary reactions. It is understood that potable water can be consumed without any restriction by human beings.OBJECTIVE:
To determine the pH value of potable water consumed by medicine students of second year at UMSA university. MATERIAL ANDMETHODS:
388 samples of potable water were analyzed which were taken from the homes of the second year students of the biochemistry department between July and August 2017, developing a descriptive study with a cross-sectional approach.RESULTS:
The following results were obtained 1) the average of the pH was 7.24; with x = 7.22 in La Paz city and x = 7.29 in El Alto city. 2) in relation to the drinking water was obtained x=7.34 in El Alto plant, x=7.21 in Tilata plant, x=7.16 in Achachicala plant and x=7.21 in Pampahasi plant.CONCLUSION:
The pH of the drinking water drunk is established within parameters with an average value of 7.24.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LIBOCS
/
LILACS
Assunto principal:
Água Potável
/
Alcalinidade da Água
/
Purificação da Água
/
Estações de Tratamento de Água
Idioma:
Es
Revista:
Cuad. Hosp. Clín
Assunto da revista:
MEDICINA
Ano de publicação:
2018
Tipo de documento:
Article
País de afiliação:
Bolívia
País de publicação: