Resultados del implante de armazón bioabsorbible de everolimus en segmentos largos atendiendo al concepto de solapamiento de armazones / Outcome after long-segment stenting with everolimus-eluting bioresorbable scaffolds focusing on the concept of overlapping implantation
Wiebe, Jens; Dörr, Oliver; Liebetrau, Christoph; Bauer, Timm; Wilkens, Eva; Ilstad, Hanna; Boeder, Niklas; Elsässer, Albrecht; Möllmann, Helge; Hamm, Christian W; Nef, Holger M.
Afiliação
  • Wiebe, Jens; Deutsches Herzzentrum München. Múnich. Alemania
  • Dörr, Oliver; University of Giessen. Department of Cardiology. Giessen. Alemania
  • Liebetrau, Christoph; Kerckhoff Heart and Thorax Center. Department of Cardiology. Bad Nauheim. Alemania
  • Bauer, Timm; University of Giessen. Department of Cardiology. Giessen. Alemania
  • Wilkens, Eva; University of Giessen. Department of Cardiology. Giessen. Alemania
  • Ilstad, Hanna; University of Giessen. Department of Cardiology. Giessen. Alemania
  • Boeder, Niklas; University of Giessen. Department of Cardiology. Giessen. Alemania
  • Elsässer, Albrecht; Heart Center Oldenburg. Department of Cardiology. Oldenburg. Alemania
  • Möllmann, Helge; Kerckhoff Heart and Thorax Center. Department of Cardiology. Bad Nauheim. Alemania
  • Hamm, Christian W; Kerckhoff Heart and Thorax Center. Department of Cardiology. Bad Nauheim. Alemania
  • Nef, Holger M; University of Giessen. Department of Cardiology. Giessen. Alemania
Rev. esp. cardiol. (Ed. impr.) ; 69(12): 1144-1151, dic. 2016. graf, tab
Artigo em Espanhol | IBECS | ID: ibc-158505
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Introducción y

objetivos:

El implante de armazones bioabsorbibles (AB) es una técnica emergente que se utiliza en las intervenciones coronarias percutáneas. Su aplicación se ha extendido a las lesiones más complejas, aunque solo se dispone de evidencia respecto a las lesiones simples. En el presente estudio se evaluó el implante del AB en lesiones largas atendiendo al solapamiento de los AB.

Métodos:

Se llevó a cabo un análisis retrospectivo de todos los pacientes consecutivos considerados aptos para el implante de un AB de ácido poli-L-láctico liberador de everolimus con una longitud total mínima de 28 mm, con independencia del número de AB implantados. Los objetivos principales fueron los eventos adversos cardiacos mayores (que incluyen la muerte cardiaca, cualquier infarto de miocardio y la revascularización de la lesión diana) y el fallo de la lesión diana (que incluye la muerte cardiaca, el infarto de miocardio del vaso diana y la revascularización de la lesión diana). Se realizó un análisis de subgrupos para la evaluación de los pacientes con AB solapados.

Resultados:

Se incluyó en total a 250 pacientes. El motivo de la angiografía fue enfermedad coronaria estable en el 36,4% de los pacientes (91 de 250), un síndrome coronario agudo en el 61,6% (154 de 250) y otros en el 2,0% (5 de 250). Se alcanzó éxito de la intervención en el 97,8% (267 de 273) de las lesiones. En el seguimiento de 12 meses, las tasas de eventos cardiacos adversos mayores, fallos de la lesión diana y trombosis del armazón fueron del 8,5, el 6,6 y el 2,3% respectivamente. El análisis del subgrupo de 239 pacientes puso de manifiesto que no había diferencias estadísticamente significativas entre los pacientes con y sin solapamiento de AB después de un seguimiento de 12 meses.

Conclusiones:

El implante de stents en segmentos largos empleando un solo armazón o múltiples armazones solapados es factible técnicamente, y los resultados a medio plazo son adecuados. Sin embargo, serán necesarios estudios aleatorizados a gran escala para confirmar la prueba de concepto (AU)
ABSTRACT
Introduction and

objectives:

The implantation of bioresorbable scaffolds (BRS) is an emerging technique used in percutaneous coronary interventions. Their application has been extended to more complex lesions, although evidence is only available for simple lesions. The present study evaluated scaffold implantation in long lesions, focusing on overlapping scaffolds.

Methods:

We retrospectively analyzed all consecutive patients eligible for stenting with everolimus-eluting poly-L-lactic acid-based BRS with a minimum total scaffold length of 28 mm, irrespective of the number of BRS used. The main target parameters were major adverse cardiac events, comprising cardiac death, any myocardial infarction, and target lesion revascularization, and target lesion failure, including cardiac death, target vessel myocardial infarction, and target lesion revascularization. A subgroup analysis included patients with overlapping BRS.

Results:

A total of 250 patients were included. The reason for angiography was stable coronary artery disease in 36.4% (91 of 250), an acute coronary syndrome in 61.6% (154 of 250), and other reasons in 2.0% (5 of 250). Procedural success was achieved in 97.8% (267 of 273) of the lesions. During follow-up, the 12-month rates of major adverse cardiac event, target lesion failure, and scaffold thrombosis were 8.5%, 6.6%, and 2.3%, respectively. Subgroup analysis of 239 patients showed that there were no statistically relevant differences between patients with and without overlapping scaffolds after a 12-month follow-up.

Conclusions:

Long-segment stenting with a single scaffold or with multiple overlapping scaffolds is technically feasible with adequate mid-term outcomes. However, large-scale randomized studies are needed to provide further proof of concept (AU)
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Doença das Coronárias / Implantes Absorvíveis / Stents Farmacológicos / Everolimo Tipo de estudo: Estudo observacional Limite: Humanos Idioma: Espanhol Revista: Rev. esp. cardiol. (Ed. impr.) Ano de publicação: 2016 Tipo de documento: Artigo Instituição/País de afiliação: Deutsches Herzzentrum München/Alemania / Heart Center Oldenburg/Alemania / Kerckhoff Heart and Thorax Center/Alemania / University of Giessen/Alemania

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Doença das Coronárias / Implantes Absorvíveis / Stents Farmacológicos / Everolimo Tipo de estudo: Estudo observacional Limite: Humanos Idioma: Espanhol Revista: Rev. esp. cardiol. (Ed. impr.) Ano de publicação: 2016 Tipo de documento: Artigo Instituição/País de afiliação: Deutsches Herzzentrum München/Alemania / Heart Center Oldenburg/Alemania / Kerckhoff Heart and Thorax Center/Alemania / University of Giessen/Alemania
...