Your browser doesn't support javascript.
loading
Doppler e marcadores séricos maternos na predição de complicações da gestação / Doppler and maternal serum screening in the prediction of pregnancy complications
Costa, Fabrício da Silva; Rocha, Rebeca Silveira; Cunha, Sérgio Pereira da; Reis, Francisco Cândido dos; Berezowski, Aderson Tadeu; Antunes-Rodrigues, José.
Afiliação
  • Costa, Fabrício da Silva; Universidade Estadual do Ceará. Curso de Medicina. Fortaleza. BR
  • Rocha, Rebeca Silveira; Universidade Estadual do Ceará. Fortaleza. BR
  • Cunha, Sérgio Pereira da; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Departamento de Ginecologia e Obstetrícia. Ribeirão Preto. BR
  • Reis, Francisco Cândido dos; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Departamento de Ginecologia e Obstetrícia. Ribeirão Preto. BR
  • Berezowski, Aderson Tadeu; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Departamento de Ginecologia e Obstetrícia. Ribeirão Preto. BR
  • Antunes-Rodrigues, José; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Departamento de Fisiologia. Ribeirão Preto. BR
Radiol. bras ; 41(1): 7-12, jan.-fev. 2008. tab
Artigo em Inglês, Português | LILACS | ID: lil-477716
Biblioteca responsável: BR734.1
RESUMO

OBJETIVO:

Comparar a eficácia do Doppler das artérias uterinas e de marcadores séricos maternos na predição de complicações da gestação.

MATERIAIS E MÉTODOS:

Trata-se de um estudo prospectivo com 49 primigestas, incluídas no estudo na 18ª semana, sendo coletada a amostra sanguínea para a realização das dosagens séricas, realizadas pelo método de quimioluminescência (alfa-fetoproteína, gonadotrofina coriônica humana e óxido nítrico) e radioimunoensaio (peptídio atrial natriurético). O Doppler das artérias uterinas foi realizado entre 24-26 semanas, determinando a presença ou ausência de incisura na onda de velocidade de fluxo. Na análise estatística utilizou-se o teste de Mann-Whitney, para amostras não-paramétricas, e o teste exato de Fisher, para parâmetros qualitativos.

RESULTADOS:

Os valores de sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo foram, respectivamente, de 8,3 por cento, 97,0 por cento, 50,0 por cento e 74,4 por cento para a alfa-fetoproteína; 8,3 por cento, 87,9 por cento, 20,0 por cento e 72,5 por cento para a gonadotrofina coriônica humana; 16,7 por cento, 97,0 por cento, 33,3 por cento e 76,2 por cento para o peptídio atrial natriurético; e 16,7 por cento, 93,9 por cento, 50,0 por cento e 75,6 por cento para o óxido nítrico. A sensibilidade do Doppler foi de 75,0 por cento, especificidade de 63,6 por cento, valor preditivo positivo de 57,1 por cento e valor preditivo negativo de 87,5 por cento.

CONCLUSÃO:

O Doppler das artérias uterinas é melhor preditor de complicações da gestação quando comparado a alguns marcadores séricos em populações de baixo risco.
ABSTRACT

OBJECTIVE:

To compare the effectiveness of uterine artery Doppler and maternal serum screening in the prediction of pregnancy complications. MATERIALS AND

METHODS:

Prospective study with 49 primigravidae at their 18th gestational week, when a blood sample was collected for serum dosage by chemiluminescence (alpha-fetoprotein, human chorionic gonadotropin and nitric oxide) and radioimmunoassay (atrial natriuretic peptide). Uterine artery Doppler was performed between the 24th and 26th gestational weeks, for determining the presence or absence of notch in the flow velocity waveform. The non-parametric Mann-Whitney test was utilized for statistical analysis, and the Fisher exact test for analysis of qualitative parameters.

RESULTS:

Sensitivity, specificity, positive and negative predictive values were, respectively, 8.3 percent, 97.0 percent, 50.0 percent and 74.4 percent for alpha-fetoprotein; 8.3 percent, 87.9 percent, 20.0 percent and 72.5 percent for human chorionic gonadotropin; 16.7 percent, 97.0 percent, 33.3 percent and 76.2 percent for atrial natriuretic peptide; and 16.7 percent, 93.9 percent, 50.0 percent and 75.6 percent for nitric oxide. The uterine artery Doppler sensitivity was 75.0 percent, specificity 63.6 percent, positive predictive value 57.1 percent, and negative predictive value 87.5 percent.

CONCLUSION:

Uterine artery Doppler is an effective method for prediction of pregnancy complications as compared with maternal serum screening in low risk populations.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Peptídeos / Pré-Eclâmpsia / Complicações na Gravidez / Útero / Biomarcadores Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Pesquisa qualitativa / Fatores de risco / Estudo de rastreamento Limite: Feminino / Humanos / Gravidez País/Região como assunto: América do Sul / Brasil Idioma: Inglês / Português Revista: Radiol. bras Assunto da revista: Diagnóstico por Imagem / Radiologia Ano de publicação: 2008 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual do Ceará/BR / Universidade de São Paulo/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Peptídeos / Pré-Eclâmpsia / Complicações na Gravidez / Útero / Biomarcadores Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Pesquisa qualitativa / Fatores de risco / Estudo de rastreamento Limite: Feminino / Humanos / Gravidez País/Região como assunto: América do Sul / Brasil Idioma: Inglês / Português Revista: Radiol. bras Assunto da revista: Diagnóstico por Imagem / Radiologia Ano de publicação: 2008 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual do Ceará/BR / Universidade de São Paulo/BR
...