Your browser doesn't support javascript.
loading
Monitorização materno-fetal durante procedimento odontológico em portadora de cardiopatia valvar / Maternal-fetal monitoring during dental procedure in patients with heart valve disease / Monitoreo maternofetal durante procedimiento odontológico en portadora de cardiopatía valvular
Neves, Itamara Lucia Itagiba; Avila, Walkiria Samuel; Neves, Ricardo Simões; Giorgi, Dante Marcelo Artigas; Santos, Jorge Francisco Kuhn dos; Oliveira Filho, Ricardo Martins; Grupi, Cesar José; Grinberg, Max; Ramires, José Antonio Franchini.
Afiliação
  • Neves, Itamara Lucia Itagiba; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Avila, Walkiria Samuel; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Neves, Ricardo Simões; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Giorgi, Dante Marcelo Artigas; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Santos, Jorge Francisco Kuhn dos; Universidade Federal de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Oliveira Filho, Ricardo Martins; Universidade de São Paulo. Instituto de Ciências Biomédicas. Departamento de Farmacologia. São Paulo. BR
  • Grupi, Cesar José; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Grinberg, Max; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Ramires, José Antonio Franchini; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
Arq. bras. cardiol ; 93(5): 430-472, nov. 2009. graf, tab
Artigo em Inglês, Espanhol, Português | LILACS | ID: lil-536212
Biblioteca responsável: BR1.1
RESUMO
FUNDAMENTO Os efeitos da anestesia local em odontologia com lidocaína e epinefrina, sobre parâmetros cardiovasculares de gestantes portadoras de valvopatias e seus conceptos, não estão esclarecidos.

OBJETIVO:

Avaliar e analisar parâmetros da cardiotocografia, de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática, quando submetida à anestesia local com 1,8 ml de lidocaína 2 por cento sem vasoconstritor e com epinefrina 1100.000, durante procedimento odontológico restaurador.

MÉTODOS:

Realizamos monitorização ambulatorial da pressão arterial, eletrocardiografia ambulatorial materna e cardiotocografia de 31 portadoras de cardiopatia reumática, entre a 28ª e 37ª semana de gestação, divididas em dois grupos conforme presença ou não do vasoconstritor

RESULTADOS:

Demonstrou-se redução significativa dos valores de frequência cardíaca materna nos dois grupos, durante o procedimento, quando comparado aos demais períodos (p < 0,001). Houve ocorrência de arritmia cardíaca em 9 (29,0 por cento) pacientes, das quais 7 (41,8 por cento) pertencentes ao grupo de 17 gestantes que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos períodos ou grupos (p > 0,05). O mesmo ocorreu (p > 0,05) com número de contrações uterinas, nível e variabilidade da linha de base e número de acelerações da frequência cardíaca fetal.

CONCLUSÃO:

O uso de 1,8 ml de lidocaína 2 por cento associado à adrenalina mostrou-se seguro e eficaz em procedimento odontológico restaurador durante a gestação de mulheres com cardiopatia valvar reumática.
ABSTRACT

BACKGROUND:

The effects of local dental anesthesia with lidocaine and epinephrine on cardiovascular parameters of pregnant women with heart valve diseases and their fetuses are not fully understood.

OBJECTIVES:

To assess and analyze cardiotocographic, blood pressure and electrocardiographic parameters of pregnant women with rheumatic heart valve disease undergoing local anesthesia with 1.8mL of lidocaine 2 percent with or without epinephrine 1100,000 during restorative dental treatment.

METHODS:

Maternal ambulatory blood pressure and electrocardiographic monitoring as well as cardiotocography of 31 patients with rheumatic heart disease were performed between the 28th and 37th week of gestation. The patients were divided into two groups, those with or without vasoconstrictor.

RESULTS:

A significant reduction in maternal heart rate was shown in both groups during the procedure in comparison with the other periods (p<0.001). Cardiac arrhythmia was observed in nine (29.0 percent) patients, of which seven (41.8 percent) were from the group of 17 pregnant women who received anesthesia plus epinephrine. No difference in maternal blood pressure was observed when periods or groups were compared (p>0.05). The same occurred (p>0.05) with the number of uterine contractions, baseline level and variability, and number of accelerations of fetal heart rate.

CONCLUSION:

The use of 1.8mL of lidocaine 2 percent in combination with epinephrine was safe and efficient in restorative dental procedures during pregnancy in women with rheumatic heart valve disease.
RESUMEN
FUNDAMENTO Los efectos de la anestesia local en odontología con lidocaína y epinefrina, sobre los parámetros cardiovasculares de gestantes portadoras de valvulopatías y sus conceptos, no son claros.

OBJETIVO:

Evaluar y analizar parámetros de la cardiotocografía, de la presión arterial y electrocardiográficos de la gestante portadora de enfermedad valvular reumática, al someterse a anestesia local con 1,8 ml de lidocaína 2 por ciento sin vasoconstrictor y con epinefrina 1100.000, durante procedimiento odontológico restaurador.

MÉTODOS:

Realizamos monitoreo ambulatorio de la presión arterial, electrocardiografía ambulatoria materna y cardiotocografía de 31 portadoras de cardiopatía reumática, entre la 28ª y la 37ª semana de gestación, divididas en dos grupos según la presencia o no del vasoconstrictor.

RESULTADOS:

Se observó reducción significativa de los valores de frecuencia cardíaca materna en los dos grupos, durante el procedimiento, al compararlo con los demás períodos (p < 0,001). Se registró ocurrencia de arritmia cardíaca en 9 (29,0 por ciento) pacientes, de las cuales 7 (41,8 por ciento) pertenecían al grupo de 17 gestantes que recibió anestesia con adrenalina. La presión arterial materna no presentó diferencia al comparar períodos o grupos (p > 0,05). Lo mismo ocurrió (p > 0,05) con el número de contracciones uterinas, nivel de variabilidad de la línea de base y número de aceleraciones de la frecuencia cardíaca fetal.

CONCLUSIÓN:

El uso de 1,8 ml de lidocaína 2 por ciento asociado a la adrenalina se mostró seguro y eficaz en procedimiento odontológico restaurador durante la gestación de mujeres con cardiopatía valvular reumática.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Complicações na Gravidez / Cardiopatia Reumática / Epinefrina / Anestesia Dentária / Anestésicos Locais / Lidocaína Tipo de estudo: Ensaio clínico controlado Limite: Adolescente / Adulto / Feminino / Humanos / Gravidez Idioma: Inglês / Espanhol / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR / Universidade de São Paulo/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Complicações na Gravidez / Cardiopatia Reumática / Epinefrina / Anestesia Dentária / Anestésicos Locais / Lidocaína Tipo de estudo: Ensaio clínico controlado Limite: Adolescente / Adulto / Feminino / Humanos / Gravidez Idioma: Inglês / Espanhol / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR / Universidade de São Paulo/BR
...