Efeitos da aplicação de protocolo de desmame de ventilação mecânica em Unidade Coronária: estudo randomizado / Effects of the use of mechanical ventilation weaning protocol in the Coronary Care Unit: randomized study
Rev. bras. cir. cardiovasc
; 26(2): 213-221, abr.-jun. 2011. tab
Article
em Pt
| LILACS
| ID: lil-597741
Biblioteca responsável:
BR1.1
RESUMO
OBJETIVO:
Comparar o desmame da ventilação mecânica realizado segundo a aplicação de protocolo baseado no teste de respiração espontânea e o mesmo procedimento realizado sem padronização, em pacientes cardiopatas.MÉTODOS:
Estudo prospectivo, aberto e randomizado. Em 2006, 36 pacientes em ventilação mecânica há mais de 24 horas foram randomizados em dois grupos grupo controle 18 pacientes foram submetidos ao desmame da ventilação mecânica de acordo com os procedimentos adotados pela equipe multiprofissional e grupo experimental 18 pacientes foram submetidos ao desmame de acordo com protocolo previamente estabelecido.RESULTADOS:
Os pacientes do grupo controle iniciaram o desmame precocemente em relação ao grupo experimental (74,7 ± 14,7 horas vs. 185,7 ± 22,9 horas; P=0,0004), Porém, após os pacientes do grupo experimental estarem aptos ao desmame, este foi realizado em um tempo mais curto em relação ao grupo controle (149,1 ± 3,6 min vs. 4179,1 ± 927,8 min; P < 0,0001) com taxas de reintubação significativamente menores (16,7 por cento vs. 66,7 por cento; P = 0,005).CONCLUSÃO:
O uso de um protocolo específico, baseado no Teste de Respiração Espontânea para desmame de ventilação mecânica, em pacientes cardiopatas, teve resultados melhores do que o desmame realizado sem um protocolo padronizado, com menor tempo de desmame e menores taxas de reintubação.ABSTRACT
OBJECTIVE:
To compare mechanical ventilation weaning based on a protocol using the spontaneous breathing trial against mechanical ventilation weaning without a standardized protocol in heart patients.METHODS:
Prospective, open, randomized study. In 2006, 36 patients undergoing mechanical ventilation for over 24 hours were randomized into two groups control group - eighteen patients whose mechanical ventilation weaning was performed according to the different procedures adopted by the multidisciplinary team; and experimental group - eighteen patients weaned according to previously established protocol.RESULTS:
Control group patients started the weaning process sooner than experimental group patients (74.7 ± 14.7 hours vs. 185.7 ± 22.9 hours, P=0.0004). However, after the experimental group patients were ready for weaning, the extubation was carried out more rapidly than in the control group (149.1 ± 3.6 min vs. 4179.1 ± 927.8 min, P < 0.0001) with significantly lower reintubation rates (16.7 percent vs. 66.7 percent, P = 0.005).CONCLUSION:
The use of a specific protocol based on the spontaneous breathing trial for mechanical ventilation weaning in heart patients had better outcomes than weaning carried out without a standardized protocol, with shorter weaning times and lower reintubation rates.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Desmame do Respirador
/
Unidades de Cuidados Coronarianos
Tipo de estudo:
Clinical_trials
/
Guideline
/
Observational_studies
Limite:
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Rev. bras. cir. cardiovasc
Assunto da revista:
CARDIOLOGIA
/
CIRURGIA GERAL
Ano de publicação:
2011
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil