Comparación de la conductancia hidráulica dentinaria, de acuerdo al tiempo de aplicación de desensibilizantes con base de oxalatos / Comparison of dentinal hydraulic conductance according to the application time of oxalate-based desensitizers
Rev. Fac. Odontol. Univ. Antioq
; 26(2): 336-357, ene.-jun. 2015. ilus, tab
Article
em Es
| LILACS
| ID: lil-735126
Biblioteca responsável:
CO332
RESUMEN
Introdución se utilizó un modelo in vitro, para medir la conductancia hidráulica en discos de dentina humana, tratados con ácido oxálico por 15, 30 o 60 s y la mantención del efecto oclusivo, medido a los 7 y 14 días post aplicación. Métodos:
45 discos dentinarios de 1mm de grosor fueron obtenidos de terceros molares humanos libres de caries, en inoclusión, de pacientes entre 16 a 30 años de edad. Los discos fueron divididos en tres grupos de estudio (n = 15), dependiendo del tiempo de aplicación de una solución comercial de desensibilizante dentinario (DD) a base de oxalato (BisBlock®), que contiene Ë 5% ácido oxálico pH 1,5-1,8 grupo A aplicación del agente por 15 s, grupo B aplicación por 30 s y grupo C por 60 s. La conductancia hidráulica de cada disco fue calculada posterior al grabado ácido, lo que corresponde a la máxima permeabilidad de dicho disco (100%), inmediatamente tras la aplicación del ácido oxálico y tras siete y 14 días de mantención en suero fisiológico.El análisis estadístico se hizo mediante test de ANOVA y post hoc de Games-Howell.Resultados:
35,46 ± 23,41% para el grupo A, 36,34 ± 15,88% para el grupo B y 24,99 ± 14,99% para el grupo C, por lo que la utilización de DD por 15, 30 ó 60 s generó una disminución en la permeabilidad que fue estadísticamente significativa (p Ë 0,05).Conclusiones:
el DD fue eficaz en reducir la conductancia hidráulica independiente del tiempo de aplicación, siendo esta reducción sólo temporal, ya que tras siete días la permeabilidad retorna a valores cercanos a los iniciales.ABSTRACT
Introduction:
an in vitro model was used to measure the hydraulic conductance in human dentin discs treated with oxalic acid for 15, 30 or 60 s maintaining the occlusive effect and measuring 7 and 14 days after application.Methods:
45 dentin discs measuring 1 mm thick were obtained from human third molars which were free of caries and in no occlusion; the samples were obtained from patients aged 16 to 30 years. Discs were sorted out into three study groups (n = 15) depending on the time of application of a commercial solution of oxalate-based dentin desensitizer (DD) (BisBlock®) which contains Ë 5% oxalic acid of 1.5-1.8 pH in group A the agent was applied for 15 s, in group B it was applied for 30 s, and in group C for 60 s. The hydraulic conductance of each disc was calculated after acid etching, which corresponds to the maximum permeability of discs (100%) after immediate application of oxalic acid, as well as seven and fourteen days of storage in saline solution. The statistical analysis was done with ANOVA test and post-hoc Games-Howell test.Results:
35,46 ± 23.41% in Group A, 36.34 ± 15.88% in Group B and 24.99 ± 14.99% in Group C, showing that the use of DD for 15, 30 or 60 s decreased permeability in a statistically significant manner (p <0.05).Conclusions:
DD was effective in reducing hydraulic conductance regardless of application time, but this reduction was temporary only, since after seven days permeability returns to values close to those of baseline.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Permeabilidade
/
Ácido Oxálico
/
Dentina
/
Difusão
Idioma:
Es
Revista:
Rev. Fac. Odontol. Univ. Antioq
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2015
Tipo de documento:
Article
País de afiliação:
Chile
País de publicação:
Colômbia