Your browser doesn't support javascript.
loading
Highly sensitive and specific noninvasive in-vivo alcohol detection using wavelength-modulated differential photothermal radiometry.
Guo, Xinxin; Shojaei-Asanjan, Khashayar; Zhang, Di; Sivagurunathan, Koneswaran; Sun, Qiming; Song, Peng; Mandelis, Andreas; Chen, Bo; Goledzinowski, Matt; Zhou, Qun; Comeau, Felix.
Afiliação
  • Guo X; Center for Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT), Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, ON M5S 3G8, Canada.
  • Shojaei-Asanjan K; Center for Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT), Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, ON M5S 3G8, Canada.
  • Zhang D; Center for Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT), Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, ON M5S 3G8, Canada.
  • Sivagurunathan K; Center for Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT), Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, ON M5S 3G8, Canada.
  • Sun Q; Center for Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT), Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, ON M5S 3G8, Canada.
  • Song P; Center for Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT), Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, ON M5S 3G8, Canada.
  • Mandelis A; Center for Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT), Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, ON M5S 3G8, Canada.
  • Chen B; Alcohol Countermeasure Systems Corp, 60 International Boulevard, Toronto, ON M9W 6J2, Canada.
  • Goledzinowski M; Alcohol Countermeasure Systems Corp, 60 International Boulevard, Toronto, ON M9W 6J2, Canada.
  • Zhou Q; Alcohol Countermeasure Systems Corp, 60 International Boulevard, Toronto, ON M9W 6J2, Canada.
  • Comeau F; Alcohol Countermeasure Systems Corp, 60 International Boulevard, Toronto, ON M9W 6J2, Canada.
Biomed Opt Express ; 9(10): 4638-4648, 2018 Oct 01.
Article em En | MEDLINE | ID: mdl-30319892

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biomed Opt Express Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Canadá País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biomed Opt Express Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Canadá País de publicação: Estados Unidos