Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38989913

RESUMO

AIMS: Transvenous lead extraction (TLE) is potentially complicated by significant tricuspid valve regurgitation increase (TRI). However, there are limited data on the effect of the bidirectional rotational mechanical sheaths on significant TRI. The aim of the present study was to investigate the rate of significant changes in tricuspid regurgitation (TR) severity following mechanical rotational TLE and their outcomes. METHODS AND RESULTS: In 158 patients (mean age 66 ± 16.9 years) undergoing mechanical rotational TLE, acute changes in TR severity were assessed by echocardiography evaluation. A significant acute TRI was defined as an increase of at least one grade with a post-extraction severity at least moderate. A total of 290 leads were extracted (mean implant duration, 93 ± 65 months). Significant TRI was noted in 5.7% of patients, and it was linked to tricuspid valve damage, TLE infection indication, and longer lead implant duration. Univariate predictors of significant TRI included implant duration of all leads [odds ratio (OR) 1.01; 95% confidence interval (CI) 1.003-1.018; P = 0.001] and right ventricular leads (OR 1.01; 95% CI 1.004-1.017; P = 0.002). Severe increase of TR following TLE was an independent predictor of mortality [hazard ratio (HR) 5.20; 95% CI 1.44-18.73; P = 0.012 ] along with severe systolic dysfunction (HR 2.37; 95% CI 1.01-5.20; P = 0.032), and systemic infection (HR 2.28; 95% CI 1.06-4.89; P = 0.035). CONCLUSION: Significant TRI was detected in 5.7% of patients following transvenous rotational mechanical lead extraction. The duration of lead implantation emerged as the sole predictor of significant TRI. Physicians engaged in TLE should exercise greater vigilance for this potential complication.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/etiologia , Masculino , Feminino , Remoção de Dispositivo/efeitos adversos , Idoso , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Idoso de 80 Anos ou mais , Índice de Gravidade de Doença , Fatores de Risco , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Valva Tricúspide/fisiopatologia , Fatores de Tempo
2.
Radiology ; 307(3): e222239, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36943075

RESUMO

Background Scar burden with late gadolinium enhancement (LGE) cardiac MRI (CMR) predicts arrhythmic events in patients with postinfarction in single-center studies. However, LGE analysis requires experienced human observers, is time consuming, and introduces variability. Purpose To test whether postinfarct scar with LGE CMR can be quantified fully automatically by machines and to compare the ability of LGE CMR scar analyzed by humans and machines to predict arrhythmic events. Materials and Methods This study is a retrospective analysis of the multicenter, multivendor CarDiac MagnEtic Resonance for Primary Prevention Implantable CardioVerter DebrillAtor ThErapy (DERIVATE) registry. Patients with chronic heart failure, echocardiographic left ventricular ejection fraction (LVEF) of less than 50%, and LGE CMR were recruited (from January 2015 through December 2020). In the current study, only patients with ischemic cardiomyopathy were included. Quantification of total, dense, and nondense scars was carried out by two experienced readers or a Ternaus network, trained and tested with LGE images of 515 and 246 patients, respectively. Univariable and multivariable Cox analyses were used to assess patient and cardiac characteristics associated with a major adverse cardiac event (MACE). Area under the receiver operating characteristic curve (AUC) was used to compare model performances. Results In 761 patients (mean age, 65 years ± 11, 671 men), 83 MACEs occurred. With use of the testing group, univariable Cox-analysis found New York Heart Association class, left ventricle volume and/or function parameters (by echocardiography or CMR), guideline criterion (LVEF of ≤35% and New York Heart Association class II or III), and LGE scar analyzed by humans or the machine-learning algorithm as predictors of MACE. Machine-based dense or total scar conferred incremental value over the guideline criterion for the association with MACE (AUC: 0.68 vs 0.63, P = .02 and AUC: 0.67 vs 0.63, P = .01, respectively). Modeling with competing risks yielded for dense and total scar (AUC: 0.67 vs 0.61, P = .01 and AUC: 0.66 vs 0.61, P = .005, respectively). Conclusion In this analysis of the multicenter CarDiac MagnEtic Resonance for Primary Prevention Implantable CardioVerter DebrillAtor ThErapy (DERIVATE) registry, fully automatic machine learning-based late gadolinium enhancement analysis reliably quantifies myocardial scar mass and improves the current prediction model that uses guideline-based risk criteria for implantable cardioverter defibrillator implantation. ClinicalTrials.gov registration no.: NCT03352648 Published under a CC BY 4.0 license. Supplemental material is available for this article.


Assuntos
Cicatriz , Meios de Contraste , Masculino , Humanos , Idoso , Volume Sistólico , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Gadolínio , Função Ventricular Esquerda , Imageamento por Ressonância Magnética/métodos , Sistema de Registros , Inteligência Artificial , Valor Preditivo dos Testes
3.
J Cardiovasc Electrophysiol ; 34(3): 728-737, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36477909

RESUMO

INTRODUCTION: Lead dwell time >10 years is a recognized predictor for transvenous lead extraction (TLE) failure and complications. Data on the efficacy and safety of TLE using the bidirectional rotational mechanical sheaths in patients with very old leads are lacking. In this multicenter study, we reported the outcomes of transvenous rotational mechanical lead extraction in patients with leads implanted for ≥10 years. METHODS: A total of 441 leads (median: 159 months [135-197]; range: 120-487) in 189 consecutive patients were removed with the Evolution RL sheaths (Cook Medical, Bloomingtom, IN, USA) and mechanical ancillary tools supporting the procedures. RESULTS: The main indication for TLE was infection in 74% of cases. Complete procedural success rate, clinical success rate, per lead were 94.8% and 98.2%, respectively. Failure of lead extraction was seen in 1.8% of leads. The additional use of a snare via the femoral approach was required in 9% of patients. Lead dwell time was the only predictor of incomplete led removal (odds ratio: 1.009; 95% confidence interval [CI]: 1.003-1.014; p = .002). Four major complication (2%) were encountered. During a mean time follow-up of 31 ± 27 months, 21 patients (11%) died. No procedure-related mortality occurred. Predictors of mortality included severe left ventricular systolic dysfunction (hazard ratio [HR]: 8.06; 95% CI: 2.99-21.73; p = .001), TLE for infection (HR: 8.0; 95% CI: 1.04-62.5; p = .045), diabetes (HR: 3.7; 95% CI: 1.48-9.5; p = .005), and previous systemic infection (HR: 3.1; 95% CI: 1.17-8.24; p = .022). Incomplete lead removal or failure lead extraction did not impact on survival during follow-up. CONCLUSION: Our findings demonstrated that the use of bidirectional rotational TLE mechanical sheaths combined with different mechanical tools and femoral approach allows reasonable success and safety in patients with very old leads at experienced specialized centers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Remoção de Dispositivo/métodos , Eletrodos Implantados , Estudos Retrospectivos , Resultado do Tratamento
4.
Eur Radiol ; 33(1): 270-282, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35788758

RESUMO

Arrhythmogenic cardiomyopathy (ACM) is a genetically determined heart muscle disease characterized by fibro-fatty myocardial replacement, clinically associated with malignant ventricular arrhythmias and sudden cardiac death. Originally described a disease with a prevalent right ventricular (RV) involvement, subsequently two other phenotypes have been recognized, such as the left dominant and the biventricular phenotypes, for which a recent International Expert consensus document provided upgrade diagnostic criteria (the 2020 "Padua Criteria"). In this novel workup for the diagnosis of the entire spectrum of phenotypic variants of ACM, including left ventricular (LV) variants, cardiac magnetic resonance (CMR) has emerged as the cardiac imaging technique of choice, due to its capability of detailed morpho-functional and tissue characterization evaluation of both RV and LV. In this review, the key role of CMR in the diagnosis of ACM is outlined, including the supplemental value for the characterization of the disease variants. An ACM-specific CMR study protocol, as well as strengths and weaknesses of each imaging technique, is also provided. KEY POINTS: • Arrhythmogenic cardiomyopathy includes three different phenotypes: dominant right, biventricular, and dominant left. • In 2020, diagnostic criteria have been updated and cardiac magnetic resonance has emerged as the cardiac imaging technique of choice. • This aim of this review is to provide an update of the current state of art regarding the use of CMR in ACM, with a particular focus on novel diagnostic criteria, CMR protocols, and prognostic significance of CMR findings in ACM.


Assuntos
Displasia Arritmogênica Ventricular Direita , Humanos , Displasia Arritmogênica Ventricular Direita/diagnóstico por imagem , Displasia Arritmogênica Ventricular Direita/genética , Ventrículos do Coração , Imageamento por Ressonância Magnética , Morte Súbita Cardíaca/patologia , Fenótipo
5.
J Cardiovasc Magn Reson ; 25(1): 71, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38031092

RESUMO

BACKGROUND: Pulmonary capillary wedge pressure (PCWP) assessment is fundamental for managing dilated cardiomyopathy (DCM) patients. Although cardiovascular magnetic resonance (CMR) has become the gold-standard imaging technique for evaluating cardiac chamber volume and function, PCWP is not routinely assessed with CMR. Therefore, this study aimed to validate the left atrial expansion index (LAEI), a LA reservoir function parameter able to estimate filling pressure with echocardiography, as a novel CMR-measured parameter for non-invasive PCWP estimation in DCM patients. METHODS: We performed a retrospective, single-center, cross-sectional study. We included electively admitted DCM patients referred to our tertiary center for further diagnostic evaluation that underwent a clinically indicated right heart catheterization (RHC) and CMR within 24 h. PCWP invasively measured during RHC was used as the reference. LAEI was calculated from CMR-measured LA maximal and minimal volumes as LAEI = ( (LAVmax-LAVmin)/LAVmin) × 100. RESULTS: We enrolled 126 patients (47 ± 14 years; 68% male; PCWP = 17 ± 9.3 mmHg) randomly divided into derivation (n = 92) and validation (n = 34) cohorts with comparable characteristics. In the derivation cohort, the log-transformed (ln) LAEI showed a strong linear correlation with PCWP (r = 0.81, p < 0.001) and remained a strong independent PCWP determinant over clinical and conventional CMR parameters. Moreover, lnLAEI accurately identified PCWP ≥ 15 mmHg (AUC = 0.939, p < 0.001), and the optimal cut-off identified (lnLAEI ≤ 3.85) in the derivation cohort discriminated PCWP ≥ 15 mmHg with 82.4% sensitivity, 88.2% specificity, and 85.3% accuracy in the validation cohort. Finally, the equation PCWP = 52.33- (9.17xlnLAEI) obtained from the derivation cohort predicted PCWP (-0.1 ± 5.7 mmHg) in the validation cohort. CONCLUSIONS: In this cohort of DCM patients, CMR-measured LAEI resulted in a novel and useful parameter for non-invasive PCWP evaluation.


Assuntos
Fibrilação Atrial , Cardiomiopatia Dilatada , Humanos , Masculino , Feminino , Pressão Propulsora Pulmonar , Estudos Retrospectivos , Cardiomiopatia Dilatada/diagnóstico por imagem , Estudos Transversais , Valor Preditivo dos Testes , Espectroscopia de Ressonância Magnética
6.
Pacing Clin Electrophysiol ; 46(8): 960-968, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36951180

RESUMO

BACKGROUND: Outcomes of transvenous lead extraction (TLE) are well reported in the general population, However, data on safety, efficacy of TLE in octogenarians with a long lead dwell time, using powered extraction tools are limited. The aim of this multicenter study was to evaluate the safety, effectiveness of TLE in octogenarians using the bidirectional rotational mechanical sheaths and mid-term outcome after TLE. METHODS: The study population comprised 83 patients (78.3% male; mean age 85 ± 3 years; [range 80-94 years]) with 181 target leads. All the leads (mean implant duration 112 ± 77 months [range 12-377]) were extracted exclusively using the Evolution RL sheaths (Cook Medical, Bloomington, IN, USA). RESULTS: The main indication for TLE was infection in 84.3% of cases. Complete procedural success rate, clinical success rate, per lead were 93.9% and 98.3%, respectively. Failure of lead extraction was seen in 1.7% of leads. The additional use of a snare was required in 8.4% of patients. Major complications occurred in one patient (1.2%). Thirty-day mortality after TLE was 6%. During a mean time follow-up of 22 ± 21 months, 24 patients (29%) died. No procedure-related mortality occurred. Predictors of mortality included ischemic cardiomyopathy (HR 4.35; 95% CI 1.87-10.13; p = .001), left ventricularejection fraction ≤35% (HR 7.89; 95% CI 3.20-19.48; p < .001), and TLE for systemic infection (HR 4.24; 95% CI 1.69-10.66; p = .002). CONCLUSIONS: At experienced centers bidirectional rotational mechanical sheaths combined with different mechanical tools and femoral approach allowreasonable success and safety in octogenarian with long lead dwell time. Patient's age should not influence the decision to extract or not the leads, although the 30-day and mid-term mortality are significant, especially in the present of specific comorbidities.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Humanos , Masculino , Feminino , Desfibriladores Implantáveis/efeitos adversos , Octogenários , Resultado do Tratamento , Comorbidade , Remoção de Dispositivo/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos
7.
Eur Heart J Suppl ; 25(Suppl C): C144-C154, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125320

RESUMO

The designation of 'arrhythmogenic cardiomyopathy' reflects the evolving concept of a heart muscle disease affecting not only the right ventricle (ARVC) but also the left ventricle (LV), with phenotypic variants characterized by a biventricular (BIV) or predominant LV involvement (ALVC). Herein, we use the term 'scarring/arrhythmogenic cardiomyopathy (S/ACM)' to emphasize that the disease phenotype is distinctively characterized by loss of ventricular myocardium due to myocyte death with subsequent fibrous or fibro-fatty scar tissue replacement. The myocardial scarring predisposes to potentially lethal ventricular arrhythmias and underlies the impairment of systolic ventricular function. S/ACM is an 'umbrella term' which includes a variety of conditions, either genetic or acquired (mostly post-inflammatory), sharing the typical 'scarring' phenotypic features of the disease. Differential diagnoses include 'non-scarring' heart diseases leading to either RV dilatation from left-to-right shunt or LV dilatation/dysfunction from a dilated cardiomyopathy. The development of 2020 upgraded criteria ('Padua criteria') for diagnosis of S/ACM reflected the evolving clinical experience with the expanding spectrum of S/ACM phenotypes and the advances in cardiac magnetic resonance (CMR) imaging. The Padua criteria aimed to improve the diagnosis of S/ACM by incorporation of CMR myocardial tissue characterization findings. Risk stratification of S/ACM patients is mostly based on arrhythmic burden and ventricular dysfunction severity, although other ECG or imaging parameters may have a role. Medical therapy is crucial for treatment of ventricular arrhythmias and heart failure. Implantable cardioverter defibrillator (ICD) is the only proven life-saving treatment, despite its significant morbidity because of device-related complications and inappropriate shocks. Selection of patients who can benefit the most from ICD therapy is one of the most challenging issues in clinical practice.

8.
Rev Cardiovasc Med ; 23(10): 335, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39077127

RESUMO

Arrhythmogenic cardiomyopathy (ACM) is a rare heart muscle disease characterized by a progressive fibro-fatty myocardial replacement, ventricular arrhythmias, and increased risk of sudden cardiac death. The first diagnostic criteria were proposed by an International Task Force of experts in 1994 and revised in 2010. At that time, ACM was mainly considered a right ventricle disease, with left ventricle involvement only in the late stages. Since 2010, several pathological and clinical studies using cardiac magnetic resonance (CMR) imaging have allowed to understand the phenotypic expression of the disease and to reach the current idea that ACM may affect both ventricles. Indeed, left ventricular involvement may parallel or exceed right ventricular involvement. The main limitations of the 2010 criteria included the poor sensitivity for left ventricular involvement and the lack of inclusion of tissue characterization by CMR. The 2020 International criteria (the Padua criteria) were developed to overcome these shortcomings. The most important innovations are the introduction of a set of criteria for identifying left ventricular variants and the use of CMR for tissue characterization. Moreover, criteria for right ventricular involvement were also updated taking into account new evidence. According to the number of criteria for right and/or left ventricular involvement, the 2020 Padua criteria allows diagnosing three ACM phenotypic variants: right-dominant, biventricular and left-dominant. This review discusses the evolving approach to diagnosis of ACM, from the 1994 International Criteria to the 2020 Padua criteria.

9.
Pacing Clin Electrophysiol ; 45(1): 92-102, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34699079

RESUMO

BACKGROUND: Recent studies have shown that Evolution RL bidirectional rotational mechanical sheath (Cook Medical, USA) is an effective and safe technique for transvenous lead extraction (TLE). We reported our experience with the bidirectional rotational mechanical tools using a multidisciplinary approach highlighting the value of a joint cardiac surgeon and electrophysiologist collaboration. METHODS: The study population comprised 84 patients (77% male; mean age 65 ± 18 years) undergoing TLE. After a multidisciplinary evaluation, a combined procedure was considered. RESULTS: The main indication for TLE was infection in 54 cases (64%). Overall, 152 leads were extracted with a mean implant duration of 94 ± 63 months (range 12-421). Complete procedural success rate, clinical success rate, and lead removal with clinical success rate were 91.6% (77/84), 97.6% (82/84), and 98.6% (150/152), respectively. Eighteen combined procedures were performed in 12 patients (14%), such as "hybrid approach" (n = 2) or TLE concomitant to: 1) transcatheter aspiration procedure for large vegetation (n = 8); 2) left ventricular assistance device implantation as bridge to cardiac transplantation (n = 1); 3) permanent pacing with epicardial leads (n = 6); 4) tricuspid valve replacement (n = 1). One major complication (1.2%) and 11 (13%) minor complications were encountered. No injury to the superior vena cava occurred and no procedure-related deaths were reported. During a mean time follow-up of 21 ± 18 months, 17 patients (20%) died. They were more often diabetics (p = .02), and they underwent TLE more often for infection (p = .004). CONCLUSIONS: Our results support the finding that excellent outcomes can be achieved in performing TLE of chronically implanted leads by using the Evolution RL bidirectional rotational mechanical sheath and a multidisciplinary team approach involving both electrophysiologist and cardiac surgeon as first line operators.


Assuntos
Cardiologistas , Remoção de Dispositivo/métodos , Eletrodos Implantados , Relações Interprofissionais , Infecções Relacionadas à Prótese/terapia , Cirurgiões , Idoso , Eletrofisiologia Cardíaca , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Marca-Passo Artificial
10.
Europace ; 23(6): 907-917, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-33313835

RESUMO

AIMS: The aim of this study is to evaluate the clinical features of patients affected by arrhythmogenic cardiomyopathy (AC), presenting with chest pain and myocardial enzyme release in the setting of normal coronary arteries ('hot phase'). METHODS AND RESULTS: We collected detailed anamnestic, clinical, instrumental, genetic, and histopathological findings as well as follow-up data in a series of AC patients who experienced a hot phase. A total of 23 subjects (12 males, mean age at the first episode 27 ± 16 years) were identified among 560 AC probands and family members (5%). At first episode, 10 patients (43%) already fulfilled AC diagnostic criteria. Twelve-lead electrocardiogram recorded during symptoms showed ST-segment elevation in 11 patients (48%). Endomyocardial biopsy was performed in 11 patients, 8 of them during the acute phase showing histologic evidence of virus-negative myocarditis in 88%. Cardiac magnetic resonance was performed in 21 patients, 12 of them during the acute phase; oedema and/or hyperaemia were detected in 7 (58%) and late gadolinium enhancement in 11 (92%). At the end of follow-up (mean 17 years, range 1-32), 12 additional patients achieved an AC diagnosis. Genetic testing was positive in 77% of cases and pathogenic mutations in desmoplakin gene were the most frequent. No patient complained of sustained ventricular arrhythmias or died suddenly during the 'hot phase'. CONCLUSION: 'Hot phase' represents an uncommon clinical presentation of AC, which often occurs in paediatric patients and carriers of desmoplakin gene mutations. Tissue characterization, family history, and genetic test represent fundamental diagnostic tools for differential diagnosis.


Assuntos
Displasia Arritmogênica Ventricular Direita , Miocardite , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/genética , Criança , Meios de Contraste , Desmoplaquinas/genética , Gadolínio , Humanos , Masculino , Miocardite/diagnóstico , Miocardite/genética
11.
Europace ; 23(7): 1072-1083, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33792661

RESUMO

AIMS: The aim of this registry was to evaluate the additional prognostic value of a composite cardiac magnetic resonance (CMR)-based risk score over standard-of-care (SOC) evaluation in a large cohort of consecutive unselected non-ischaemic cardiomyopathy (NICM) patients. METHODS AND RESULTS: In the DERIVATE registry (www.clinicaltrials.gov/registration: RCT#NCT03352648), 1000 (derivation cohort) and 508 (validation cohort) NICM patients with chronic heart failure (HF) and left ventricular ejection fraction <50% were included. All-cause mortality and major adverse arrhythmic cardiac events (MAACE) were the primary and secondary endpoints, respectively. During a median follow-up of 959 days, all-cause mortality and MAACE occurred in 72 (7%) and 93 (9%) patients, respectively. Age and >3 segments with midwall fibrosis on late gadolinium enhancement (LGE) were the only independent predictors of all-cause mortality (HR: 1.036, 95% CI: 1.0117-1.056, P < 0.001 and HR: 2.077, 95% CI: 1.211-3.562, P = 0.008, respectively). For MAACE, the independent predictors were male gender, left ventricular end-diastolic volume index by CMR (CMR-LVEDVi), and >3 segments with midwall fibrosis on LGE (HR: 2.131, 95% CI: 1.231-3.690, P = 0.007; HR: 3.161, 95% CI: 1.750-5.709, P < 0.001; and HR: 1.693, 95% CI: 1.084-2.644, P = 0.021, respectively). A composite clinical and CMR-based risk score provided a net reclassification improvement of 63.7% (P < 0.001) for MAACE occurrence when added to the model based on SOC evaluation. These findings were confirmed in the validation cohort. CONCLUSION: In a large multicentre, multivendor cohort registry reflecting daily clinical practice in NICM work-up, a composite clinical and CMR-based risk score provides incremental prognostic value beyond SOC evaluation, which may have impact on the indication of implantable cardioverter-defibrillator implantation.


Assuntos
Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/terapia , Meios de Contraste , Feminino , Gadolínio , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Volume Sistólico , Função Ventricular Esquerda
12.
Radiol Med ; 126(3): 365-379, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33629237

RESUMO

Cardiac magnetic resonance (CMR) has emerged as new mainstream technique for the evaluation of patients with cardiac diseases, providing unique information to support clinical decision-making. This document has been developed by a joined group of experts of the Italian Society of Cardiology and Italian society of Radiology and aims to produce an updated consensus statement about the current state of technology and clinical applications of CMR. The writing committee consisted of members and experts of both societies who worked jointly to develop a more integrated approach in the field of cardiac radiology. Part 1 of the document will cover ischemic heart disease, congenital heart disease, cardio-oncology, cardiac masses and heart transplant.


Assuntos
Técnicas de Imagem Cardíaca/normas , Consenso , Cardiopatias Congênitas/diagnóstico por imagem , Neoplasias Cardíacas/diagnóstico por imagem , Transplante de Coração , Imageamento por Ressonância Magnética/normas , Isquemia Miocárdica/diagnóstico por imagem , Cardiologia , Cardiotoxicidade/diagnóstico por imagem , Tomada de Decisão Clínica , Neoplasias Cardíacas/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Cuidados Pós-Operatórios , Prognóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Sociedades Médicas
13.
Pacing Clin Electrophysiol ; 43(6): 566-572, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32394452

RESUMO

BACKGROUND: Axillary vein access (AVA) using fluoroscopic landmarks is an effective and safe approach for cardiac implantable electronic devices (CIEDs) implantation. However, it may result in a higher radiation exposure. Ultrasound-guided axillary access (USAA) is an effective alternative technique to conventional subclavian access for CIEDs implantation. Studies comparing USAA and AVA using fluoroscopic landmarks are lacking. The purpose of this study was to compare the safety, efficacy, and radiation exposure data of the USAA approach with the AVA using fluoroscopic landmarks. METHODS: The study population included 95 consecutive patients (61% male, median age 78 years [71-85 years]) referred for CIEDs implantation using AVA with fluoroscopic landmark (n = 46) or USAA (n = 49). Baseline characteristics and radiation exposure data (Air-Kerma [mGy], DAP [Gy-cm2 ], fluoroscopy time [seconds], and X-rays emission time [seconds]) were compared according to the technique used for the AVA. RESULTS: Axillary vein was successfully accessed in 45 of 49 (92%) patients using ultrasound and in 42 of 46 (91%) patients using fluoroscopic landmarks (P = 1.00). Air-Kerma, DAP, fluoroscopy time, and X-rays emission time were shorter for USAA group compared with AVA using fluoroscopic landmarks (11 mGy [8-20] vs 37 mGy [24-81], P < .00001; 3 Gy-cm2 [2-5] vs 10 Gy-cm2 [6-16], P < .00001; 97 seconds [62-163] vs 271 seconds [185-365], P < .00001; and 7 seconds [4-10] vs 21 seconds [13-39], P < .00001). There were no significant differences between the two groups in median implant procedure time (P = .55). We did not encounter any acute or long-term complications in both groups. CONCLUSIONS: Ultrasound-guided axillary vein cannulation for CIEDs implantation is a feasible and safe alternative approach and offers a significant reduction in fluoroscopy times without increasing procedural time.


Assuntos
Veia Axilar/cirurgia , Desfibriladores Implantáveis , Fluoroscopia , Marca-Passo Artificial , Implantação de Prótese/métodos , Cirurgia Assistida por Computador , Ultrassonografia de Intervenção , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Retrospectivos
14.
J Cardiovasc Electrophysiol ; 30(6): 854-864, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30827041

RESUMO

INTRODUCTION: The recently developed second-generation subcutaneous implantable cardioverter defibrillator (S-ICD) and the intermuscular two-incision implantation technique demonstrate potential favorable features that reduce inappropriate shocks and complications. However, data concerning large patient populations are lacking. The aim of this multicentre prospective study was to evaluate the safety and outcome of second-generation S-ICD using the intermuscular two-incision technique in a large population study. METHODS AND RESULTS: The study population included 101 consecutive patients (75% male; mean age, 45 ± 13 years) who received second-generation S-ICD (EMBLEM; Boston Scientific, Marlborough, MA) implantation using the intermuscular two-incision technique as an alternative to the standard implantation technique. Twenty nine (29%) patients were implanted for secondary prevention. Twenty four (24%) patients had a previously implanted transvenous ICD. All patients were implanted without any procedure-related complications. Defibrillation testing was performed in 80 (79%) patients, and ventricular tachycardia was successfully converted at less than or equal to 65 J in 98.75% (79/80) of patients without pulse generator adjustments. During a median follow-up of 21 ± 10 months, no complications requiring surgical revision or local or systemic device-related infections were observed. Ten patients (9.9%) received appropriate and successful shocks for ventricular arrhythmias. Three (2.9%) patients experienced inappropriate shocks due to oversensing the cardiac signal (n = 1), noncardiac signal (n = 1), and a combination of both cardiac and noncardiac signals (n = 1), with one patient requiring device explantation. No patients required device explantation due to antitachycardia pacing indications. CONCLUSIONS: According to our multicentre study, second-generation S-ICD implanted with the intermuscular two-incision technique is an available safe combination and appears to be associated with a low risk of complications, such as inappropriate shocks.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Implantação de Prótese/instrumentação , Prevenção Secundária/instrumentação , Potenciais de Ação , Adolescente , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Remoção de Dispositivo , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
15.
Pacing Clin Electrophysiol ; 42(7): 989-997, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30997679

RESUMO

BACKGROUND: In addition to the Evolution RL sheath, tools by Cook Medical (Bloomington, IN, USA), supporting lead extraction (LE), are available. Data on their use are not reported in detail in previous studies. Moreover, data regarding outcome are lacking. The aim was to evaluate the safety and effectiveness of the Evolution sheath (Evolution RL and Evolution Shortie, Cook Medical) by using a stepwise approach with the available extraction tools and the outcome. METHODS: A total of 393 leads in 198 consecutive patients were removed with the Evolution RL sheath and ancillary tools using a stepwise approach. RESULTS: The main indication for LE was infection in 125 (63.1%) cases. The mean implant duration was 95.4 ± 59.7 months. According to our stepwise approach, the Evolution Shortie RL sheath was used in all cases and complete LE was achieved in 24 (12.2%) cases. The Evolution RL was used in 174 (87.8%) cases and the SteadySheath Evolution tissue stabilization sheath (Cook Medical) in 87 (44%) because of tenacious fibrosis anchored targeted leads. Compression coil (OneTie, Cook Medical) was used in 141 (71%) cases. Complete procedural success rate, clinical success rate, and lead removal with clinical success rate were 97%, 99%, and 99.5%, respectively. One major complication (0.5%) and 10 (5%) minor complications were encountered. During a mean time follow-up of 12 ± 9 months, 14 (7%) patients died. Predictors of mortality included impaired renal function (HR 5.7; 95% CI 1.9-17.6; P = 0.002), extraction because of infection (hazard ratio [HR] 4.0; 95% confidence interval [CI] 1-18.1; P = 0.045), and diabetes (HR 3.2; 95% CI 1.1-9.8; P = 0.036). CONCLUSIONS: Lead extraction using the Evolution RL bidirectional rotational mechanical sheath and ancillary tools in a systematic stepwise approach was effective and safe.


Assuntos
Remoção de Dispositivo/instrumentação , Eletrodos Implantados , Marca-Passo Artificial , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Ecocardiografia Transesofagiana , Desenho de Equipamento , História do Século XVII , Humanos , Segurança do Paciente , Fatores de Risco , Ultrassonografia de Intervenção
16.
Pacing Clin Electrophysiol ; 40(12): 1368-1373, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28994461

RESUMO

BACKGROUND: The effectiveness of implantable cardioverter-defibrillator (ICD) in the elderly is uncertain, given their competing risk of nonarrhythmic death. Guidelines state that an ICD should be implanted if the expectation of survival is at least 1 year. However, survival is not easy to predict in elderly patients with severe cardiac disease. AIM: To assess 12-month survival after ICD implantation in patients aged ≥75 years, to identify predictors of 12-month mortality, and to evaluate the incidence of ICD therapy during follow-up. METHODS: We retrospectively analyzed all clinical, instrumental, and survival data of patients ≥75 years old who received an ICD in our center from 2000 to 2013. RESULTS: We included 127 patients (mean age 78 years). ICD was implanted for primary prevention in 61%. The 12-month survival rate was 87.4%. At both univariate and multivariate analyses, left ventricular ejection fraction (EF) ≤ 25%, and moderate to severe impaired renal function (IRF) independently predicted 12-month mortality that was as high as 45.5% in patients with both risk factors. During a median follow-up of 38 months, 30 patients (23.6%) received ≥1 appropriate ICD interventions, but only 3.1% of shocks occurred during the first year, and none in the subgroup of patients with EF ≤ 25% and IRF. CONCLUSION: Twelve-month survival in elderly patients after ICD implantation is good and the indication for ICD should not be based on age alone. However, the subgroup with EF ≤ 25% and IRF showed a high 12-month nonarrhythmic mortality and did not benefit from ICD implantation.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/terapia , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/terapia , Idoso , Feminino , Seguimentos , Cardiopatias , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo
17.
Circulation ; 132(7): 556-66, 2015 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-26160859

RESUMO

BACKGROUND: Mitral valve prolapse (MVP) may present with ventricular arrhythmias and sudden cardiac death (SCD) even in the absence of hemodynamic impairment. The structural basis of ventricular electric instability remains elusive. METHODS AND RESULTS: The cardiac pathology registry of 650 young adults (≤40 years of age) with SCD was reviewed, and cases with MVP as the only cause of SCD were re-examined. Forty-three patients with MVP (26 females; age range, 19-40 years; median, 32 years) were identified (7% of all SCD, 13% of women). Among 12 cases with available ECG, 10 (83%) had inverted T waves on inferior leads, and all had right bundle-branch block ventricular arrhythmias. A bileaflet involvement was found in 70%. Left ventricular fibrosis was detected at histology at the level of papillary muscles in all patients, and inferobasal wall in 88%. Living patients with MVP with (n=30) and without (control subjects; n=14) complex ventricular arrhythmias underwent a study protocol including contrast-enhanced cardiac magnetic resonance. Patients with either right bundle-branch block type or polymorphic complex ventricular arrhythmias (22 females; age range, 28-43 years; median, 41 years), showed a bileaflet involvement in 70% of cases. Left ventricular late enhancement was identified by contrast-enhanced cardiac magnetic resonance in 93% of patients versus 14% of control subjects (P<0.001), with a regional distribution overlapping the histopathology findings in SCD cases. CONCLUSIONS: MVP is an underestimated cause of arrhythmic SCD, mostly in young adult women. Fibrosis of the papillary muscles and inferobasal left ventricular wall, suggesting a myocardial stretch by the prolapsing leaflet, is the structural hallmark and correlates with ventricular arrhythmias origin. Contrast-enhanced cardiac magnetic resonance may help to identify in vivo this concealed substrate for risk stratification.


Assuntos
Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/etiologia , Prolapso da Valva Mitral/complicações , Adulto , Arritmias Cardíacas/patologia , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/patologia , Cordas Tendinosas/patologia , Angiografia Coronária , Morte Súbita Cardíaca/epidemiologia , Eletrocardiografia , Eletrocardiografia Ambulatorial , Feminino , Fibrose , Ventrículos do Coração/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Valva Mitral/patologia , Prolapso da Valva Mitral/patologia , Músculos Papilares/patologia , Fatores Sexuais , Adulto Jovem
18.
J Electrocardiol ; 49(4): 587-95, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27178316

RESUMO

BACKGROUND: The pathophysiologic mechanisms and the prognostic meaning of electrocardiographic (ECG) T-wave inversion (TWI) occurring in a subgroup of patients with clinically suspected acute myocarditis remain to be elucidated. Contrast-enhanced cardiac magnetic resonance (CMR) offers the potential to identify myocardial tissue changes such as edema and/or fibrosis which may underlie TWI. METHODS AND RESULTS: We studied 76 consecutive patients (median age 34years) with clinically suspected acute myocarditis, using a comprehensive CMR protocol which included T2 weighted sequences for myocardial edema. At the time of CMR, TWI was observed in 21 (27%) patients. There was a statistically significant association of TWI with the median number of left ventricular (LV) segments showing both any pattern of myocardial edema (transmural and non-transmural) [5 (3-7) vs. 3 (2-4); p=0.015] and myocardial late-gadolinium-enhancement [4 (3-7) vs. 3 (2-4); p=0.002]. Transmural myocardial edema involving ≥2 LV segments was found in 17/21 (81%) patients with TWI versus 13/55 (24%) patients without TWI (p<0.001) and remained the only independent predictor of TWI at multivariable analysis (OR=9.96; 95%CI=2.71-36.6; p=0.001). Overall, topographic concordance between the location of TWI across the ECG leads and the regional distribution of transmural myocardial edema was 88%. There was no association between acute TWI and reduced LV ejection fraction (<55%) at 6-months of follow-up. CONCLUSIONS: This is the first study to demonstrate an association between LV transmural myocardial edema as evidenced by CMR sequences and TWI in clinically suspected acute myocarditis. As an expression of reversible myocardial edema, development of TWI during the acute disease phase was not a predictor of LV systolic dysfunction at follow-up.


Assuntos
Edema Cardíaco/complicações , Edema Cardíaco/diagnóstico , Eletrocardiografia/métodos , Imagem Cinética por Ressonância Magnética/métodos , Miocardite/complicações , Miocardite/diagnóstico , Doença Aguda , Adulto , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Europace ; 17(4): 574-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25564551

RESUMO

AIMS: The second-generation cryoballoon (CB2) with increased surface cooling has recently become available. The aim was to investigate the incidence and characteristics of phrenic nerve palsy (PNP) during pulmonary vein isolation (PVI) using the CB2 as compared with the first-generation balloon (CB1). METHODS AND RESULTS: A total of 360 consecutive patients with atrial fibrillation underwent PVI with the CB1 (106 patients) or the CB2 (254 patients). Right PN function was monitored by continuous stimulation and palpation during septal PV ablation. Persistent PNP (present at discharge) occurred in 2.8 and 1.9% (P = 0.63) of patients, transient PNP (full recovery before discharge) in 5.9 and 3.8% (P = 0.41) of patients in the CB2 and CB1 group, respectively. Phrenic nerve palsy during ablation at the right inferior PV was observed in 0% (CB1) and 4.3% (CB2, P = 0.03) of patients. Using the CB2, a trend of reduced incidence of persistent PNP over quartiles of consecutive patients was observed [4.8% (Q1) vs. 0% (Q4); P = 0.077]. At the culprit PV, PNP occurred after 3.5 ± 2.1 (CB1) and 1.1 ± 0.4 applications (CB2; P = 0.036). Complete recovery of PN function occurred after 29 ± 11 (CB1) and 259 ± 137 days (CB2; P = 0.004). CONCLUSIONS: The rate of transient/persistent PNP associated with the use of the CB2 was 5.9 and 2.8%, respectively. Time to restitution of PN function was longer using the CB2.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Criocirurgia/estatística & dados numéricos , Nervo Frênico/lesões , Veias Pulmonares/cirurgia , Paralisia Respiratória/epidemiologia , Cateterismo Cardíaco/estatística & dados numéricos , Ablação por Cateter/estatística & dados numéricos , Comorbidade , Criocirurgia/métodos , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA