Pacing Clin Electrophysiol ; 43(6): 566-572, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32394452

RESUMO

BACKGROUND: Axillary vein access (AVA) using fluoroscopic landmarks is an effective and safe approach for cardiac implantable electronic devices (CIEDs) implantation. However, it may result in a higher radiation exposure. Ultrasound-guided axillary access (USAA) is an effective alternative technique to conventional subclavian access for CIEDs implantation. Studies comparing USAA and AVA using fluoroscopic landmarks are lacking. The purpose of this study was to compare the safety, efficacy, and radiation exposure data of the USAA approach with the AVA using fluoroscopic landmarks. METHODS: The study population included 95 consecutive patients (61% male, median age 78 years [71-85 years]) referred for CIEDs implantation using AVA with fluoroscopic landmark (n = 46) or USAA (n = 49). Baseline characteristics and radiation exposure data (Air-Kerma [mGy], DAP [Gy-cm2 ], fluoroscopy time [seconds], and X-rays emission time [seconds]) were compared according to the technique used for the AVA. RESULTS: Axillary vein was successfully accessed in 45 of 49 (92%) patients using ultrasound and in 42 of 46 (91%) patients using fluoroscopic landmarks (P = 1.00). Air-Kerma, DAP, fluoroscopy time, and X-rays emission time were shorter for USAA group compared with AVA using fluoroscopic landmarks (11 mGy [8-20] vs 37 mGy [24-81], P < .00001; 3 Gy-cm2 [2-5] vs 10 Gy-cm2 [6-16], P < .00001; 97 seconds [62-163] vs 271 seconds [185-365], P < .00001; and 7 seconds [4-10] vs 21 seconds [13-39], P < .00001). There were no significant differences between the two groups in median implant procedure time (P = .55). We did not encounter any acute or long-term complications in both groups. CONCLUSIONS: Ultrasound-guided axillary vein cannulation for CIEDs implantation is a feasible and safe alternative approach and offers a significant reduction in fluoroscopy times without increasing procedural time.


Assuntos
Veia Axilar/cirurgia , Desfibriladores Implantáveis , Fluoroscopia , Marca-Passo Artificial , Implantação de Prótese/métodos , Cirurgia Assistida por Computador , Ultrassonografia de Intervenção , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA