Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Respir Res ; 25(1): 159, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600600

RESUMO

BACKGROUND: Light chain deposition disease (LCDD) is a very rare entity. Clinical manifestations of LCDD vary according to the organs involved. Data on pulmonary LCDD are scarce and limited to small series or case reports. This study aimed to describe the characteristics and outcome of diffuse pulmonary non-amyloid LCDD localized to the lungs. STUDY DESIGN AND METHODS: A multicenter retrospective cohort study was conducted. Clinical characteristics were collected, and chest CTs were centrally reviewed. The diagnosis of pulmonary non-amyloid LCDD was confirmed by immunohistochemistry. RESULTS: Thirty-one cases were identified (68% female), with a median age at diagnosis of 50 years (IQR 20). Baseline FEV1/FVC was < 0.70 in 45% of patients. Mean (± SD) FEV1 and DLCO were 86% ± 26.2 and 52% ± 23.9, respectively. CT revealed peculiar patterns of thin-walled cysts (58%) and thin-walled cystic bronchiectases (27%). Increased serum kappa light chain was found in 87% of patients. Histological analysis showed kappa light chain deposits in all patients, except one with lambda chain deposits. Median annual FEV1 decline was 127 ml (IQR 178) and median DLCO decline was 4.3% (IQR 4.3). Sixteen patients received immunomodulatory treatment or chemotherapy; serum light chain levels decreased in 9 cases (75%), without significant improvement in FEV1 (p = 0.173). Overall, 48% of patients underwent bilateral lung transplantation. Transplant-free survival at 5 and 10 years were 70% and 30%, respectively. An annual FEV1 decline greater than 127 ml/year was associated with increased risk of death or transplantation (p = 0.005). CONCLUSIONS: Diffuse pulmonary LCDD is characterised by female predominance, a peculiar imaging pattern with bronchiectasis and/or cysts, progressive airway obstruction and severe DLCO impairment, and poor outcome. Lung transplantation is a treatment of choice.


Assuntos
Bronquiectasia , Cistos , Humanos , Feminino , Adulto Jovem , Adulto , Masculino , Cadeias Leves de Imunoglobulina , Estudos Retrospectivos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Cistos/patologia , Fenótipo
2.
Eur Radiol ; 34(1): 214-225, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37530810

RESUMO

OBJECTIVES: To evaluate the prevalence of intra-myocardial fatty scars (IMFS) most likely indicating previous silent myocardial infarction (SMI), as detected on coronary artery calcium (CAC) computed tomography (CT) scans in diabetic patients without history of coronary heart disease (CHD). METHODS: Diabetic patients screened for silent coronary insufficiency in a tertiary-care, university hospital between Jan-2015 and Dec-2016 were categorized according to their CAC score in two groups comprising 242 patients with CACS = 0 and 145 patients with CACS ≥ 300. CAC-CT scans were retrospectively evaluated for subendorcardial and transmural IMFS of the left ventricle. Adipose remodeling, patients' characteristics, cardiovascular risk factors and metabolic profile were compared between groups. RESULTS: Eighty-three (21%) patients with IMFS were identified, 55 (37.9%) in the group CACS ≥ 300 and 28 (11.6%) in the CACS = 0 (OR = 4.67; 95% CI = 2.78-7.84; p < 0.001). Total and average surface of IMFS and their number per patient were similar in both groups (p = 0.55; p = 0.29; p = 0.61, respectively). In the group CACS ≥ 300, patients with IMFS were older (p = 0.03) and had longer-lasting diabetes (p = 0.04). Patients with IMFS were older and had longer history of diabetes, reduced glomerular filtration rate, more coronary calcifications (all p < 0.05), and higher prevalence of carotid plaques (OR = 3.03; 95% CI = 1.43-6.39, p = 0.004). After correction for other variables, only a CACS ≥ 300 (OR = 5.12; 95% CI = 2.66-9.85; p < 0.001) was associated with an increased risk of having IMFS. CONCLUSIONS: In diabetic patients without known CHD, IMFSs were found in patients without coronary calcifications, although not as frequently as in patients with heavily calcified coronary arteries. It remains to be established if this marker translates in an upwards cardiovascular risk restratification especially in diabetic patients with CACS = 0. CLINICAL RELEVANCE STATEMENT: In diabetic patients without history of coronary heart disease, intramyocardial fatty scars, presumably of post-infarction origin, can be detected on coronary artery calcium CT scans more frequently, but not exclusively, if the coronary arteries are heavily calcified as compared to those without calcifications. KEY POINTS: • Intramyocardial fatty scars (IMFS), presumably of post-infarction origin, can be detected on coronary artery calcium (CAC) CT scans more frequently, but not exclusively, in diabetic patients with CACS ≥ 300 as compared to patients CACS = 0. • Patients with IMFS were older and had longer history of diabetes, reduced glomerular filtration rate, and more coronary calcifications. • Carotid plaques and CACS ≥ 300 were associated with an increased risk of having IMFS, about three and five folds respectively.


Assuntos
Calcinose , Doença da Artéria Coronariana , Diabetes Mellitus , Infarto do Miocárdio , Calcificação Vascular , Humanos , Cálcio/metabolismo , Angiografia Coronária/métodos , Estudos Retrospectivos , Cicatriz , Fatores de Risco , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Diabetes Mellitus/epidemiologia , Calcinose/complicações , Calcinose/diagnóstico por imagem , Calcinose/epidemiologia , Valor Preditivo dos Testes
3.
J Cardiovasc Magn Reson ; 26(1): 101037, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38499269

RESUMO

BACKGROUND: Free-running cardiac and respiratory motion-resolved whole-heart five-dimensional (5D) cardiovascular magnetic resonance (CMR) can reduce scan planning and provide a means of evaluating respiratory-driven changes in clinical parameters of interest. However, respiratory-resolved imaging can be limited by user-defined parameters which create trade-offs between residual artifact and motion blur. In this work, we develop and validate strategies for both correction of intra-bin and compensation of inter-bin respiratory motion to improve the quality of 5D CMR. METHODS: Each component of the reconstruction framework was systematically validated and compared to the previously established 5D approach using simulated free-running data (N = 50) and a cohort of 32 patients with congenital heart disease. The impact of intra-bin respiratory motion correction was evaluated in terms of image sharpness while inter-bin respiratory motion compensation was evaluated in terms of reconstruction error, compression of respiratory motion, and image sharpness. The full reconstruction framework (intra-acquisition correction and inter-acquisition compensation of respiratory motion [IIMC] 5D) was evaluated in terms of image sharpness and scoring of image quality by expert reviewers. RESULTS: Intra-bin motion correction provides significantly (p < 0.001) sharper images for both simulated and patient data. Inter-bin motion compensation results in significant (p < 0.001) lower reconstruction error, lower motion compression, and higher sharpness in both simulated (10/11) and patient (9/11) data. The combined framework resulted in significantly (p < 0.001) sharper IIMC 5D reconstructions (End-expiration (End-Exp): 0.45 ± 0.09, End-inspiration (End-Ins): 0.46 ± 0.10) relative to the previously established 5D implementation (End-Exp: 0.43 ± 0.08, End-Ins: 0.39 ± 0.09). Similarly, image scoring by three expert reviewers was significantly (p < 0.001) higher using IIMC 5D (End-Exp: 3.39 ± 0.44, End-Ins: 3.32 ± 0.45) relative to 5D images (End-Exp: 3.02 ± 0.54, End-Ins: 2.45 ± 0.52). CONCLUSION: The proposed IIMC reconstruction significantly improves the quality of 5D whole-heart MRI. This may be exploited for higher resolution or abbreviated scanning. Further investigation of the diagnostic impact of this framework and comparison to gold standards is needed to understand its full clinical utility, including exploration of respiratory-driven changes in physiological measurements of interest.


Assuntos
Artefatos , Cardiopatias Congênitas , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Humanos , Reprodutibilidade dos Testes , Feminino , Masculino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Adulto , Adulto Jovem , Imageamento por Ressonância Magnética , Adolescente , Mecânica Respiratória , Técnicas de Imagem de Sincronização Respiratória , Criança , Pessoa de Meia-Idade , Respiração , Imagem Cinética por Ressonância Magnética
4.
Semin Respir Crit Care Med ; 45(3): 342-364, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38714203

RESUMO

Systemic sclerosis (SSc) is a rare autoimmune disease characterized by a tripod combining vasculopathy, fibrosis, and immune-mediated inflammatory processes. The prevalence of interstitial lung disease (ILD) in SSc varies according to the methods used to detect it, ranging from 25 to 95%. The fibrotic and vascular pulmonary manifestations of SSc, particularly ILD, are the main causes of morbidity and mortality, contributing to 35% of deaths. Although early trials were conducted with cyclophosphamide, more recent randomized controlled trials have been performed to assess the efficacy and tolerability of several medications, mostly mycophenolate, rituximab, tocilizumab, and nintedanib. Although many uncertainties remain, expert consensus is emerging to optimize the therapeutic management and to provide clinicians with evidence-based clinical practice guidelines for patients with SSc-ILD. This article provides an overview, in the light of the latest advances, of the available evidence for the diagnosis and management of SSc-ILD.


Assuntos
Imunossupressores , Doenças Pulmonares Intersticiais , Escleroderma Sistêmico , Humanos , Doenças Pulmonares Intersticiais/etiologia , Escleroderma Sistêmico/complicações , Imunossupressores/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Guias de Prática Clínica como Assunto , Indóis
5.
Respirology ; 29(4): 312-323, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38345107

RESUMO

BACKGROUND AND OBJECTIVE: Variants in surfactant genes SFTPC or ABCA3 are responsible for interstitial lung disease (ILD) in children and adults, with few studies in adults. METHODS: We conducted a multicentre retrospective study of all consecutive adult patients diagnosed with ILD associated with variants in SFTPC or ABCA3 in the French rare pulmonary diseases network, OrphaLung. Variants and chest computed tomography (CT) features were centrally reviewed. RESULTS: We included 36 patients (median age: 34 years, 20 males), 22 in the SFTPC group and 14 in the ABCA3 group. Clinical characteristics were similar between groups. Baseline median FVC was 59% ([52-72]) and DLco was 44% ([35-50]). An unclassifiable pattern of fibrosing ILD was the most frequent on chest CT, found in 85% of patients, however with a distinct phenotype with ground-glass opacities and/or cysts. Nonspecific interstitial pneumonia and usual interstitial pneumonia were the most common histological patterns in the ABCA3 group and in the SFTPC group, respectively. Annually, FVC and DLCO declined by 1.87% and 2.43% in the SFTPC group, respectively, and by 0.72% and 0.95% in the ABCA3 group, respectively (FVC, p = 0.014 and DLCO , p = 0.004 for comparison between groups). Median time to death or lung transplantation was 10 years in the SFTPC group and was not reached at the end of follow-up in the ABCA3 group. CONCLUSION: SFTPC and ABCA3-associated ILD present with a distinct phenotype and prognosis. A radiologic pattern of fibrosing ILD with ground-glass opacities and/or cysts is frequently found in these rare conditions.


Assuntos
Cistos , Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Masculino , Adulto , Criança , Humanos , Estudos Retrospectivos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Doenças Pulmonares Intersticiais/genética , Pulmão/diagnóstico por imagem , Proteína C Associada a Surfactante Pulmonar , Transportadores de Cassetes de Ligação de ATP/genética
6.
Radiology ; 309(1): e222432, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37787672

RESUMO

CT systems equipped with photon-counting detectors (PCDs), referred to as photon-counting CT (PCCT), are beginning to change imaging in several subspecialties, such as cardiac, vascular, thoracic, and musculoskeletal radiology. Evidence has been building in the literature underpinning the many advantages of PCCT for different clinical applications. These benefits derive from the distinct features of PCDs, which are made of semiconductor materials capable of converting photons directly into electric signal. PCCT advancements include, among the most important, improved spatial resolution, noise reduction, and spectral properties. PCCT spatial resolution on the order of 0.25 mm allows for the improved visualization of small structures (eg, small vessels, arterial walls, distal bronchi, and bone trabeculations) and their pathologies, as well as the identification of previously undetectable anomalies. In addition, blooming artifacts from calcifications, stents, and other dense structures are reduced. The benefits of the spectral capabilities of PCCT are broad and include reducing radiation and contrast material dose for patients. In addition, multiple types of information can be extracted from a single data set (ie, multiparametric imaging), including quantitative data often regarded as surrogates of functional information (eg, lung perfusion). PCCT also allows for a novel type of CT imaging, K-edge imaging. This technique, combined with new contrast materials specifically designed for this modality, opens the door to new applications for imaging in the future.


Assuntos
Artérias , Tomografia Computadorizada por Raios X , Humanos , Artefatos , Brônquios , Meios de Contraste
7.
Eur Radiol ; 33(1): 699-710, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35864348

RESUMO

OBJECTIVES: To assess the impact of a new artificial intelligence deep-learning reconstruction (Precise Image; AI-DLR) algorithm on image quality against a hybrid iterative reconstruction (IR) algorithm in abdominal CT for different clinical indications. METHODS: Acquisitions on phantoms were performed at 5 dose levels (CTDIvol: 13/11/9/6/1.8 mGy). Raw data were reconstructed using level 4 of iDose4 (i4) and 3 levels of AI-DLR (Smoother/Smooth/Standard). Noise power spectrum (NPS), task-based transfer function (TTF) and detectability index (d') were computed: d' modelled detection of a liver metastasis (LM) and hepatocellular carcinoma at portal (HCCp) and arterial (HCCa) phases. Image quality was subjectively assessed on an anthropomorphic phantom by 2 radiologists. RESULTS: From Standard to Smoother levels, noise magnitude and average NPS spatial frequency decreased and the detectability (d') of all simulated lesions increased. For both inserts, TTF values were similar for all three AI-DLR levels from 13 to 6 mGy but decreased from Standard to Smoother levels at 1.8 mGy. Compared to the i4 used in clinical practice, d' values were higher using the Smoother and Smooth levels and close for the Standard level. For all dose levels, except at 1.8 mGy, radiologists considered images satisfactory for clinical use for the 3 levels of AI-DLR, but rated images too smooth using the Smoother level. CONCLUSION: Use of the Smooth and Smoother levels of AI-DLR reduces the image noise and improves the detectability of lesions and spatial resolution for standard and low-dose levels. Using the Smooth level is apparently the best compromise between the lowest dose level and adequate image quality. KEY POINTS: • Evaluation of the impact of a new artificial intelligence deep-learning reconstruction (AI-DLR) on image quality and dose compared to a hybrid iterative reconstruction (IR) algorithm. • The Smooth and Smoother levels of AI-DLR reduced the image noise and improved the detectability of lesions and spatial resolution for standard and low-dose levels. • The Smooth level seems the best compromise between the lowest dose level and adequate image quality.


Assuntos
Aprendizado Profundo , Interpretação de Imagem Radiográfica Assistida por Computador , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Redução da Medicação , Inteligência Artificial , Imagens de Fantasmas , Algoritmos , Tomografia Computadorizada por Raios X/métodos
8.
Eur Radiol ; 33(8): 5476-5488, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36920517

RESUMO

OBJECTIVES: To evaluate the quality of virtual monochromatic images (VMIs) from spectral photon-counting CT (SPCCT) and two energy-integrating detector dual-energy CT (EID-DECT) scanners from the same manufacturer, for the coronary lumen. METHODS: A 21-cm section of the Mercury v4.0 phantom was scanned using a cardiac CT protocol. VMIs from 40 to 90 keV were reconstructed using high-resolution (HR) parameters for EID-DECT and SPCCT (CB and HRB kernels at 0.67 mm slice thickness, respectively). Ultra-high-resolution (UHR) parameters were used in addition to SPCCT (detailed-2 kernel, 0.43 mm slice thickness). Noise-power-spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were computed for 2-mm-diameter lumen detection. In consensus, two radiologists analyzed the quality of the images from 8 patients who underwent coronary CTA on both CT systems. RESULTS: For all keV images, fpeak, f50, and d' were higher with SPCCT. The fpeak and f50 were higher with UHR-SPCCT with greater noise and lower d' compared to those of the HR-SPCCT images. Noise magnitude was constant for all energy levels (keV) with both systems, and lower with HR images, and d' decreased as keV decreased. Subjective analysis showed greater lumen sharpness and overall quality for HR and UHR-SPCCT images using all keV, with a greater difference at low keV compared to HR-EID-DECT images. CONCLUSION: HR and UHR-SPCCT images gave greater detectability of the coronary lumen for 40 to 90 keV VMIs compared to two EID-DECT systems, with benefits of higher lumen sharpness and overall quality. KEY POINTS: • Compared with 2 dual-energy CT systems, spectral photon-counting CT (SPCCT) improved spatial resolution, noise texture, noise magnitude, and detectability of the coronary lumen. • Use of ultra-high-resolution parameters with SPCCT improved spatial resolution and noise texture and provided high detectability of the coronary lumen, despite an increase in noise magnitude. • In eight patients, radiologists found greater overall image quality with SPCCT for all virtual monochromatic images with a greater difference at low keV, compared with dual-energy CT systems.


Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Coração , Fótons
9.
Radiology ; 303(2): 303-313, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35166583

RESUMO

Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sandfort and Bluemke in this issue.


Assuntos
Angiografia por Tomografia Computadorizada , Fótons , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
10.
Respir Res ; 23(1): 332, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36482462

RESUMO

BACKGROUND: Diffuse interstitial lung diseases (ILD) constitute a heterogeneous group of conditions with complex etiological diagnoses requiring a multidisciplinary approach. Much is still unknown about them, particularly their relationship with occupational exposures. The primary objective of this study was to investigate the distribution of occupational exposures according to type of ILD. The secondary objectives were to estimate the proportion of ILDs possibly related to occupational exposure and to evaluate the added value of the participation of an occupational disease consultant in ILD multidisciplinary discussions (MDD). METHODS: From May to December 2020, all consecutive patients with ILD whose cases were reviewed during a MDD in a referral centre for ILD were prospectively offered a consultation with an occupational disease consultant. RESULTS: Of the 156 patients with ILD whose cases were reviewed in MDD during the study period, 141 patients attended an occupational exposure consultation. Occupational exposure was identified in 97 patients. Occupational exposure to asbestos was found in 12/31 (38.7%) patients with idiopathic pulmonary fibrosis (IPF) and in 9/18 (50.0%) patients with unclassifiable fibrosis. Occupational exposure to metal dust was found in 13/31 (41.9%) patients with IPFs and 10/18 (55.6%) patients with unclassifiable fibrosis. Silica exposure was found in 12/50 (24.0%) patients with autoimmune ILD. The link between occupational exposure and ILD was confirmed for 41 patients after the specialist occupational consultation. The occupational origin had not been considered (n = 9) or had been excluded or neglected (n = 4) by the MDD before the specialised consultation. A total of 24 (17%) patients were advised to apply for occupational disease compensation, including 22 (15.6%) following the consultation. In addition, a diagnosis different from the one proposed by the MDD was proposed for 18/141 (12.8%) patients. CONCLUSIONS: In our study, we found a high prevalence of occupational respiratory exposure with a potential causal link in patients with ILD. We suggest that a systematic specialised consultation in occupational medicine could be beneficial in the ILD diagnostic approach.


Assuntos
Doenças Pulmonares Intersticiais , Doenças Profissionais , Humanos , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/epidemiologia , Fibrose
11.
Curr Opin Pulm Med ; 28(5): 432-440, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35855575

RESUMO

PURPOSE OF REVIEW: Pleuroparenchymal fibroelastosis (PPFE) is a clinico-radiologic-pathologic interstitial lung disease (ILD) characterized by fibrosis that has upper lobe and subpleural predominance, involving both the visceral pleura and the subjacent subpleural lung parenchyma, and comprises dense fibroelastic changes with prominent elastosis of the alveolar walls together with fibrous thickening of the visceral pleura. The goal of this review is to summarize the state-of-the-art understanding in PPFE. RECENT FINDINGS: PPFE was described in an increasing number of conditions. The course of disease is heterogeneous. Idiopathic PPFE, cases associated with telomerase-related gene mutations, cases related to a history of chemotherapy, and cases combining PPFE with a pattern of usual interstitial pneumonia, may have a particularly poor prognosis. Well-conducted retrospective studies identified marked PPFE features in approximately 10% of patients with idiopathic pulmonary fibrosis, 11% of patients with systemic sclerosis-associated ILD, 6.5% of patients with rheumatoid arthritis-associated ILD, and 23% of patients with hypersensitivity pneumonitis. Drug therapy has not been evaluated prospectively. A small retrospective study suggests that nintedanib may slow disease progression. However, whether the efficacy of antifibrotics is comparable in PPFE and in other forms of progressive pulmonary fibrosis warrants further evaluation. SUMMARY: Accumulating data indicate that PPFE features are associated with poor prognosis in fibrosing ILDs. Further research on the management of PPFE is warranted.


Assuntos
Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Fibrose , Humanos , Fibrose Pulmonar Idiopática/complicações , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Fibrose Pulmonar Idiopática/tratamento farmacológico , Pulmão/diagnóstico por imagem , Pulmão/patologia , Doenças Pulmonares Intersticiais/complicações , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Doenças Pulmonares Intersticiais/tratamento farmacológico , Pleura/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
12.
Eur Radiol ; 32(6): 4292-4303, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35029730

RESUMO

OBJECTIVES: To compare the lung CT volume (CTvol) and pulmonary function tests in an interstitial lung disease (ILD) population. Then to evaluate the CTvol loss between idiopathic pulmonary fibrosis (IPF) and non-IPF and explore a prognostic value of annual CTvol loss in IPF. METHODS: We conducted in an expert center a retrospective study between 2005 and 2018 on consecutive patients with ILD. CTvol was measured automatically using commercial software based on a deep learning algorithm. In the first group, Spearman correlation coefficients (r) between forced vital capacity (FVC), total lung capacity (TLC), and CTvol were calculated. In a second group, annual CTvol loss was calculated using linear regression analysis and compared with the Mann-Whitney test. In a last group of IPF patients, annual CTvol loss was calculated between baseline and 1-year CTs for investigating with the Youden index a prognostic value of major adverse event at 3 years. Univariate and log-rank tests were calculated. RESULTS: In total, 560 patients (4610 CTs) were analyzed. For 1171 CTs, CTvol was correlated with FVC (r: 0.86) and TLC (r: 0.84) (p < 0.0001). In 408 patients (3332 CT), median annual CTvol loss was 155.7 mL in IPF versus 50.7 mL in non-IPF (p < 0.0001) over 5.03 years. In 73 IPF patients, a relative annual CTvol loss of 7.9% was associated with major adverse events (log-rank, p < 0.0001) in univariate analysis (p < 0.001). CONCLUSIONS: Automated lung CT volume may be an alternative or a complementary biomarker to pulmonary function tests for the assessment of lung volume loss in ILD. KEY POINTS: • There is a good correlation between lung CT volume and forced vital capacity, as well as for with total lung capacity measurements (r of 0.86 and 0.84 respectively, p < 0.0001). • Median annual CT volume loss is significantly higher in patients with idiopathic pulmonary fibrosis than in patients with other fibrotic interstitial lung diseases (155.7 versus 50.7 mL, p < 0.0001). • In idiopathic pulmonary fibrosis, a relative annual CT volume loss higher than 9.4% is associated with a significantly reduced mean survival time at 2.0 years versus 2.8 years (log-rank, p < 0.0001).


Assuntos
Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Humanos , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Medidas de Volume Pulmonar , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Capacidade Vital
13.
Eur Radiol ; 32(1): 524-532, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34185147

RESUMO

OBJECTIVES: To evaluate the image quality (IQ) of a spectral photon-counting CT (SPCCT) using filtered back projection (FBP) and hybrid iterative reconstruction (IR) algorithms (iDose4), in comparison with a dual-layer CT (DLCT) system, and to choose the best image quality according to the IR level for SPCCT. METHODS: Two phantoms were scanned using a standard lung protocol (120 kVp, 40 mAs) with SPCCT and DLCT systems. Raw data were reconstructed using FBP and 9 iDose4 levels (i1/i2/i3/i4/i5/i6/i7/i9/i11) for SPCCT and 7 for DLCT (i1/i2/i3/i4/i5/i6/i7). Noise power spectrum and task-based transfer function (TTF) were computed. Detectability index (d') was computed for detection of 4 mm ground-glass nodule (GGN) and solid nodule. Two chest radiologists performed an IQ evaluation (noise/nodule sharpness/nodule conspicuity/overall IQ) in consensus, and chose the best image for SPCCT. RESULTS: Noise magnitude was -47% ± 2% lower on average with SPCCT than with DLCT for iDose4 range from i1 to i6. Average NPS spatial frequencies increased for SPCCT in comparison with DLCT. TTF also increased, except for the air insert with FBP, and i1/i2/i3. Higher detectability was found for SPCCT for both GGN and solid nodules. IQ for both types of nodule was rated consistently higher with SPCCT than with DLCT for the same iDose4 level. For SPCCT and both nodules, the scores for noise and conspicuity improved with increasing iDose4 level. iDose4 level 6 provided the best subjective IQ for both types of nodule. CONCLUSIONS: Higher IQ for GGN and solid nodules was demonstrated with SPCCT compared with DLCT with better detectability using iDose4. KEY POINTS: Using spectral photon-counting CT compared with dual-layer CT, noise magnitude was reduced with improvements in spatial resolution and detectability of ground-glass nodules and solid lung nodules. As the iDose4 level increased, noise magnitude was reduced and detectability of ground-glass and solid lung nodules was better for both CT systems. For spectral photon-counting CT imaging, two chest radiologists determined iDose4 level 6 as the best image quality for detecting ground-glass nodules and solid lung nodules.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação
14.
J Nucl Cardiol ; 29(3): 1064-1074, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33145738

RESUMO

BACKGROUND: Previous studies have suggested the role of microcalcifications in plaque vulnerability. This exploratory study sought to assess the potential of hybrid positron-emission tomography (PET)/magnetic resonance imaging (MRI) using 18F-sodium fluoride (18F-NaF) to check simultaneously 18F-NaF uptake, a marker of microcalcifications, and morphological criteria of vulnerability. METHODS AND RESULTS: We included 12 patients with either recently symptomatic or asymptomatic carotid stenosis. All patients underwent 18F-NaF PET/MRI. 18F-NaF target-to-background ratio (TBR) was measured in culprit and nonculprit (including contralateral plaques of symptomatic patients) plaques as well as in other arterial walls. Morphological criteria of vulnerability were assessed on MRI. Mineral metabolism markers were also collected. 18F-NaF uptake was higher in culprit compared to nonculprit plaques (median TBR 2.6 [2.2-2.8] vs 1.7 [1.3-2.2]; P = 0.03) but was not associated with morphological criteria of vulnerability on MRI. We found a positive correlation between 18F-NaF uptake and calcium plaque volume and ratio but not with circulating tissue-nonspecific alkaline phosphatase (TNAP) activity and inorganic pyrophosphate (PPi) levels. 18F-NaF uptake in the other arterial walls did not differ between symptomatic and asymptomatic patients. CONCLUSIONS: 18F-NaF PET/MRI may be a promising tool for providing additional insights into the plaque vulnerability.


Assuntos
Calcinose , Estenose das Carótidas , Placa Aterosclerótica , Calcinose/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Placa Aterosclerótica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Fluoreto de Sódio
15.
Radiology ; 300(1): 98-107, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33944628

RESUMO

Background Macrophage burden is a major factor in the risk of atherosclerotic plaque rupture, and its evaluation remains challenging with molecular noninvasive imaging approaches. Photon-counting CT (PCCT) with k-edge imaging aims to allow for the specific detection of macrophages using gold nanoparticles. Purpose To perform k-edge imaging in combination with gold nanoparticles to detect and quantify the macrophage burden within the atherosclerotic aortas of rabbits. Materials and Methods Atherosclerotic and control New Zealand white rabbits were imaged before and at several time points up to 2 days after intravenous injection of gold nanoparticles (3.5 mL/kg, 65 mg gold per milliliter). Aortic CT angiography was performed at the end of the follow-up using an intravenous injection of an iodinated contrast material. Gold k-edge and conventional CT images were reconstructed for qualitative and quantitative assessment of the macrophage burden. PCCT imaging results were compared with findings at histologic examination, quantitative histomorphometry, transmission electron microscopy, and quantitative inductively coupled plasma optical emission spectrometry. Pearson correlations between the macrophage area measured in immunostained sections and the concentration of gold and attenuation measured in the corresponding PCCT sections were calculated. Results Seven rabbits with atherosclerosis and four control rabbits without atherosclerosis were analyzed. In atherosclerotic rabbits, calcifications were observed along the aortic wall before injection. At 2 days after injection of gold nanoparticles, only gold k-edge images allowed for the distinction of plaque enhancement within calcifications and for lumen enhancement during angiography. A good correlation was observed between the gold concentration measured within the wall and the macrophage area in 35 plaques (five per rabbit) (r = 0.82; 95% CI: 0.67, 0.91; P < .001), which was higher than that observed on conventional CT images (r = 0.41; 95% CI: 0.09, 0.65; P = .01). Transmission electron microscopy and inductively coupled plasma optical emission spectrometry analyses confirmed the gold k-edge imaging findings. Conclusion Photon-counting CT with gold nanoparticles allowed for the noninvasive evaluation of both molecular and anatomic information in vivo in rabbits with atherosclerotic plaques. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Leiner in this issue.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Placa Aterosclerótica/diagnóstico por imagem , Animais , Aorta/diagnóstico por imagem , Modelos Animais de Doenças , Ouro , Macrófagos , Nanopartículas Metálicas , Fótons , Coelhos
16.
Eur Respir J ; 57(2)2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32943410

RESUMO

In patients with chronic fibrosing interstitial lung disease (ILD), a progressive fibrosing phenotype (PF-ILD) may develop, but information on the frequency and characteristics of this population outside clinical trials is lacking.We assessed the characteristics and outcomes of patients with PF-ILD other than idiopathic pulmonary fibrosis (IPF) in a real-world, single-centre clinical cohort. The files of all consecutive adult patients with fibrosing ILD (2010-2017) were examined retrospectively for pre-defined criteria of ≥10% fibrosis on high-resolution computed tomography and progressive disease during overlapping windows of 2 years. Baseline was defined as the date disease progression was identified. Patients receiving nintedanib or pirfenidone were censored from survival and progression analyses.In total, 1395 patients were screened; 617 had ILD other than IPF or combined pulmonary fibrosis and emphysema, and 168 had progressive fibrosing phenotypes. In 165 evaluable patients, median age was 61 years; 57% were female. Baseline mean forced vital capacity (FVC) was 74±22% predicted. Median duration of follow-up was 46.2 months. Annualised FVC decline during the first year was estimated at 136±328 mL using a linear mixed model. Overall survival was 83% at 3 years and 72% at 5 years. Using multivariate Cox regression analysis, mortality was significantly associated with relative FVC decline ≥10% in the previous 24 months (p<0.05), age ≥50 years (p<0.01) and diagnosis subgroup (p<0.01).In this cohort of patients with PF-ILD not receiving antifibrotic therapy, the disease followed a course characterised by continued decline in lung function, which predicted mortality.


Assuntos
Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Adulto , Progressão da Doença , Feminino , Fibrose , Humanos , Fibrose Pulmonar Idiopática/complicações , Fibrose Pulmonar Idiopática/tratamento farmacológico , Doenças Pulmonares Intersticiais/complicações , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/tratamento farmacológico , Pessoa de Meia-Idade , Estudos Retrospectivos , Capacidade Vital
17.
Respir Res ; 22(1): 162, 2021 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-34030695

RESUMO

BACKGROUND: There is a paucity of data on the epidemiology, survival estimates and healthcare resource utilisation and associated costs of patients with progressive fibrosing interstitial lung disease (PF-ILD) in France. An algorithm for extracting claims data was developed to indirectly identify and describe patients with PF-ILD in the French national administrative healthcare database. METHODS: The French healthcare database, the Système National des Données de Santé (SNDS), includes data related to ambulatory care, hospitalisations and death for 98.8% of the population. In this study, algorithms based on age, diagnosis and healthcare consumption were created to identify adult patients with PF-ILD other than idiopathic pulmonary fibrosis between 2010 and 2017. Incidence, prevalence, survival estimates, clinical features and healthcare resource usage and costs were described among patients with PF-ILD. RESULTS: We identified a total of 14,413 patients with PF-ILD. Almost half of them (48.1%) were female and the mean (± standard deviation) age was 68.4 (± 15.0) years. Between 2010 and 2017, the estimated incidence of PF-ILD ranged from 4.0 to 4.7/100,000 person-years and the estimated prevalence from 6.6 to 19.4/100,000 persons. The main diagnostic categories represented were exposure-related ILD other than hypersensitivity pneumonitis (n = 3486; 24.2%), idiopathic interstitial pneumonia (n = 3113; 21.6%) and rheumatoid arthritis-associated ILD (n = 2521; 17.5%). Median overall survival using Kaplan-Meier estimation was 3.7 years from the start of progression. During the study, 95.2% of patients had ≥ 1 hospitalisation for respiratory care and 34.3% were hospitalised in an intensive care unit. The median (interquartile range) total specific cost per patient during the follow-up period was €25,613 (10,622-54,287) and the median annual cost per patient was €18,362 (6856-52,026), of which €11,784 (3003-42,097) was related to hospitalisations. Limitations included the retrospective design and identification of cases through an algorithm in the absence of chest high-resolution computed tomography scans and pulmonary function tests. CONCLUSIONS: This large, real-world, longitudinal study provides important insights into the characteristics, epidemiology and healthcare resource utilisation and costs associated with PF-ILD in France using a comprehensive and exhaustive database, and provides vital evidence that PF-ILD represents a high burden on both patients and healthcare services. Trial registration ClinicalTrials.gov, NCT03858842. ISRCTN, ISRCTN12345678. Registered 3 January 2019-Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT03858842.


Assuntos
Doenças Pulmonares Intersticiais/epidemiologia , Fibrose Pulmonar/epidemiologia , Demandas Administrativas em Assistência à Saúde , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Efeitos Psicossociais da Doença , Bases de Dados Factuais , Progressão da Doença , Feminino , França/epidemiologia , Custos Hospitalares , Humanos , Incidência , Estudos Longitudinais , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/mortalidade , Doenças Pulmonares Intersticiais/terapia , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Fibrose Pulmonar/diagnóstico , Fibrose Pulmonar/mortalidade , Fibrose Pulmonar/terapia , Estudos Retrospectivos , Fatores de Tempo
18.
Eur Radiol ; 31(9): 7132-7142, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33740093

RESUMO

OBJECTIVES: To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT obtained with regular iodine dose. MATERIALS AND METHODS: A phantom simulating regular and reduced iodine injection was used to determine the accuracy and precision of lumen area segmentation for various VMI energy levels. We retrospectively included 203 patients from December 2017 to August 2018 (mean age, 51.7 ± 16.8 years) who underwent CCTA using either standard (group A, n = 103) or reduced (group B, n = 100) iodine doses. Conventional images (group A) were qualitatively and quantitatively compared with 55-keV VMI (group B). We recorded the location of venous catheters. RESULTS: In vitro, VMI outperformed conventional CT, with a segmentation accuracy of 0.998 vs. 1.684 mm2, respectively (p < 0.001), and a precision of 0.982 vs. 1.229 mm2, respectively (p < 0.001), in simulated overweight adult subjects. In vivo, the rate of diagnostic CCTA in groups A and B was 88.4% (n = 91/103) vs. 89% (n = 89/100), respectively, and noninferiority of protocol B was inferred. Contrast-to-noise ratios (CNR) of lumen versus fat and muscle were higher in group B (p < 0.001) and comparable for lumen versus calcium (p = 0.423). Venous catheters were more often placed on the forearm or hand in group B (p < 0.001). CONCLUSION: In vitro, low-keV VMI improve vessel area segmentation. In vivo, low-keV VMI allows for a 40% iodine dose and injection rate reduction while maintaining diagnostic image quality and improves the CNR between lumen versus fat and muscle. KEY POINTS: • Dual-energy coronary CT angiography is becoming increasingly available and might help improve patient management. • Compared with regular-iodine-dose coronary CT angiography, reduced-iodine-dose dual-energy CT with low-keV monochromatic image reconstructions performed better in phantom-based vessel cross-sectional segmentation and proved to be noninferior in vivo. • Patients receiving reduced-iodine-dose dual-energy coronary CT angiography often had the venous catheter placed on the forearm or wrist without compromising image quality.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Adulto , Idoso , Angiografia por Tomografia Computadorizada , Meios de Contraste , Relação Dose-Resposta a Droga , Humanos , Iodo/administração & dosagem , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
19.
Eur Radiol ; 31(2): 795-803, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32813105

RESUMO

OBJECTIVES: To assess the diagnostic performances of chest CT for triage of patients in multiple emergency departments during COVID-19 epidemic, in comparison with reverse transcription polymerase chain reaction (RT-PCR) test. METHOD: From March 3 to April 4, 2020, 694 consecutive patients from three emergency departments of a large university hospital, for which a hospitalization was planned whatever the reasons, i.e., COVID- or non-COVID-related, underwent a chest CT and one or several RT-PCR tests. Chest CTs were rated as "Surely COVID+," "Possible COVID+," or "COVID-" by experienced radiologists. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated using the final RT-PCR test as standard of reference. The delays for CT reports and RT-PCR results were recorded and compared. RESULTS: Among the 694 patients, 287 were positive on the final RT-PCR exam. Concerning the 694 chest CT, 308 were rated as "Surely COVID+", 34 as "Possible COVID+," and 352 as "COVID-." When considering only the "Surely COVID+" CT as positive, accuracy, sensitivity, specificity, PPV, and NPV reached 88.9%, 90.2%, 88%, 84.1%, and 92.7%, respectively, with respect to final RT-PCR test. The mean delay for CT reports was three times shorter than for RT-PCR results (187 ± 148 min versus 573 ± 327 min, p < 0.0001). CONCLUSION: During COVID-19 epidemic phase, chest CT is a rapid and most probably an adequately reliable tool to refer patients requiring hospitalization to the COVID+ or COVID- hospital units, when response times for virological tests are too long. KEY POINTS: • In a large university hospital in Lyon, France, the accuracy, sensitivity, specificity, PPV, and NPV of chest CT for COVID-19 reached 88.9%, 90.2%, 88%, 84.1%, and 92.7%, respectively, using RT-PCR as standard of reference. • The mean delay for CT reports was three times shorter than for RT-PCR results (187 ± 148 min versus 573 ± 327 min, p < 0.0001). • Due to high accuracy of chest CT for COVID-19 and shorter time for CT reports than RT-PCR results, chest CT can be used to orient patients suspected to be positive towards the COVID+ unit to decrease congestion in the emergency departments.


Assuntos
COVID-19/diagnóstico por imagem , Triagem , Idoso , Idoso de 80 Anos ou mais , COVID-19/epidemiologia , Serviço Hospitalar de Emergência , Epidemias , Feminino , França , Hospitais Universitários , Humanos , Masculino , Valor Preditivo dos Testes , SARS-CoV-2 , Fatores de Tempo , Tomografia Computadorizada por Raios X
20.
Eur Radiol ; 30(1): 425-431, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31332557

RESUMO

OBJECTIVES: To assess the capability of a newly developed material decomposition method from contrast-enhanced dual-energy CT images, aiming to better visualize the aortic wall and aortic intramural hematoma (IMH), compared with true non-contrast (TNC) CT. MATERIALS AND METHODS: Twenty-two patients (11 women; mean age, 61 ± 20 years) with acute chest pain underwent 25 dual-layer non-contrast and contrast-enhanced CT. CT-angiography images were retrospectively processed using two-material decomposition analysis, where we defined the first material as the content of a region of interest placed in the ascending aorta for each patient, and the second material as water. Two independent radiologists assessed the images from the second material termed "dark-blood" images and the TNC images regarding contrast-to-noise ratio (CNR) between the wall and the lumen, diagnostic quality regarding the presence of aortic wall thickening, and the inner/outer vessel wall conspicuity. RESULTS: Diagnostic quality scores in normal aortic segments were 0.9 ± 0.3 and 2.7 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.5 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In aortic segments with IMH, diagnostic quality scores were 1.7 ± 0.5 and 2.4 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.7 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In normal aortic segments, CNRs were 0.3 ± 0.2 and 2.8 ± 0.9 on TNC and dark-blood images, respectively (p < 0.001). In aortic segments with IMH, CNRs were 0.3 ± 0.2 and 4.0 ± 1.0 on TNC and dark-blood images, respectively (p < 0.001). CONCLUSIONS: Compared with true non-contrast CT, dark-blood material decomposition maps enhance quantitative and qualitative image quality for the assessment of normal aortic wall and IMH. KEY POINTS: • Current dual-energy CT-angiography provides virtual non-contrast and bright-blood images. • Dark-blood images represent a new way to assess the vascular wall structure with dual-energy CT and can improve the lumen-to-wall contrast compared with true non-contrast CT. • This dual-energy CT material decomposition method is likely to improve contrast resolution in other applications as well, taking advantage of the high spatial resolution of CT.


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA