Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Med Ultrason ; 17(4): 464-74, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26649341

RESUMEN

AIMS: The aim of our study was to analyze the variation of acoustic output, as expressed by the thermal (TI) and mechanical index (MI), during the learning curve for a fetal heart scan at 11-13 gestational weeks, with the introduction of a new ultrasound system. MATERIAL AND METHODS: This was a prospective, observational study on 303 normal fetuses. The fetal heart was examined transabdominally using B-Mode and high definition (HD) color Doppler to obtain standard parameters: four-chamber, outflow tracts and three-vessel-trachea views. Data were analyzed in groups of 20 consecutive examinations and the percentage of successful examinations was calculated. TI and MI were retrieved from HD color Doppler examinations of the fetal heart and from pulsed-wave Doppler assessment of the tricuspid flow and ductus venosus. RESULTS: MI values from the color Doppler examination of the fetal heart showed a continuous decrease (0.81 to 0.75, p<0.001), along the learning phase. TI and MI indices from pulsed-wave Doppler evaluation of the tricuspid flow increased at the beginning of the learning phase and stabilized afterwards (0.34 to 0.36, p<0.05 and 0.37 to 0.4, p<0.001, respectively). TI from color Doppler exam of the heart and indices from ductus venosus assessment were very constant and did not change along the studied periods. The length of Doppler examination of the heart increased after about 80 cases by 25%, to a mean of 4 minutes (p<0.05). CONCLUSIONS: Safety indices from Doppler evaluation of the fetal heart and tricuspid flow vary during the learning curve for fetal heart assessment. Also, the occurrence of constant values suggests the potential for their supplementary active reduction. For a better adaptation to a new ultrasound technology, the sonographer should scan the fetal heart longer in the first trimester and follow displayed safety indices along the first 80 cases.


Asunto(s)
Ecocardiografía Doppler en Color/estadística & datos numéricos , Corazón Fetal/diagnóstico por imagen , Seguridad del Paciente/estadística & datos numéricos , Primer Trimestre del Embarazo , Exposición a la Radiación/estadística & datos numéricos , Ultrasonografía Prenatal/estadística & datos numéricos , Femenino , Edad Gestacional , Humanos , Curva de Aprendizaje , Masculino , Embarazo , Estudios Prospectivos , Rumanía/epidemiología , Sonido , Carga de Trabajo/estadística & datos numéricos
2.
PLoS One ; 10(5): e0127570, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26018336

RESUMEN

The aim of our study was to evaluate the thermal index (TI) and mechanical index (MI), during the assessment of the fetal heart at the time of first-trimester scan, with different ultrasound machines. This was part of an observational study conducted in patients undergoing routine first-trimester screening. Cases were examined with Voluson E8 or 730Pro scanners using 2-8 MHz transabdominal probes. TI and MI were retrieved from the saved displays while in gray mode, color flow mapping and pulsed-wave (PW) Doppler examinations of the fetal heart and also from the ductus venosus (DV) assessment. We evaluated 552 fetal cardiac examinations, 303 (55%) performed with Voluson E8 and 249 (45%) with Voluson 730Pro ultrasound machines. The gray-scale exam of the heart and the PW Doppler DV assessment had TI values significantly lower for the Voluson E8 group (median, 0.04 vs. 0.2 and 0.1 vs. 0.2, respectively). The MI values from gray-scale and color flow mapping of the heart were significantly lower (median, 0.6 vs, 1.2 and 0.7 vs. 1) and for PW Doppler exam of the tricuspid flow were significantly higher (median 0.4 vs. 0.2) in the Voluson E8 group. The TI values from Doppler examinations of the heart, either color flow or PW imaging and MI values from DV assessment were not significantly different between the two groups. A different (newer) generation of ultrasound equipment provides lower or at least the same safety indices for most of the first-trimester heart examinations.


Asunto(s)
Ecocardiografía Doppler en Color/efectos adversos , Corazón Fetal/diagnóstico por imagen , Ultrasonografía Prenatal/efectos adversos , Adulto , Femenino , Humanos , Embarazo , Primer Trimestre del Embarazo , Estudios Prospectivos
3.
Ultrasound Med Biol ; 41(1): 35-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25438839

RESUMEN

We measured acoustic output, expressed as the thermal index (TI) and mechanical index (MI), during fetal echocardiography at the time of the first trimester scan. TI and MI were retrieved from the saved displays during gray-mode, high-definition color flow Doppler and pulsed-wave Doppler (tricuspid flow) ultrasound examinations of the fetal heart and from the ductus venosus assessment. A total of 399 fetal cardiac examinations were evaluated. There was a significant increase in TI values from B-mode studies (0.07 ± 0.04 [mean ± SD]) to color flow mapping (0.2 ± 0.0) and pulsed-wave Doppler studies (0.36 ± 0.05). The TI from ductus venosus assessment (0.1 ± 0.01) was significantly lower than those from Doppler examinations of the heart. MI values from B-mode scans (0.65 ± 0.12) and color flow mapping (0.71 ± 0.11) were comparable, although different, and both values were higher than those from pulsed-wave Doppler tricuspid evaluation (0.39 ± 0.03). There were no differences in MI values from power Doppler assessment between the tricuspid flow and ductus venosus. Safety indices were remarkably stable and were largely constant, especially for color Doppler (TI), tricuspid flow (MI) and ductus venosus assessment (TI, MI). We acquired satisfactory Doppler images and/or signals at acoustic levels that were lower than the actual recommendations and never reached a TI of 0.5.


Asunto(s)
Temperatura Corporal/fisiología , Ecocardiografía/métodos , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/fisiología , Primer Trimestre del Embarazo/fisiología , Ultrasonografía Prenatal/métodos , Absorción de Radiación , Adolescente , Adulto , Temperatura Corporal/efectos de la radiación , Módulo de Elasticidad/fisiología , Módulo de Elasticidad/efectos de la radiación , Femenino , Corazón Fetal/efectos de la radiación , Humanos , Embarazo , Primer Trimestre del Embarazo/efectos de la radiación , Dosis de Radiación , Radiometría/métodos , Sonido , Estrés Mecánico , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...