Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Nature ; 628(8009): 910-918, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38570680

RESUMEN

OSCA/TMEM63 channels are the largest known family of mechanosensitive channels1-3, playing critical roles in plant4-7 and mammalian8,9 mechanotransduction. Here we determined 44 cryogenic electron microscopy structures of OSCA/TMEM63 channels in different environments to investigate the molecular basis of OSCA/TMEM63 channel mechanosensitivity. In nanodiscs, we mimicked increased membrane tension and observed a dilated pore with membrane access in one of the OSCA1.2 subunits. In liposomes, we captured the fully open structure of OSCA1.2 in the inside-in orientation, in which the pore shows a large lateral opening to the membrane. Unusually for ion channels, structural, functional and computational evidence supports the existence of a 'proteo-lipidic pore' in which lipids act as a wall of the ion permeation pathway. In the less tension-sensitive homologue OSCA3.1, we identified an 'interlocking' lipid tightly bound in the central cleft, keeping the channel closed. Mutation of the lipid-coordinating residues induced OSCA3.1 activation, revealing a conserved open conformation of OSCA channels. Our structures provide a global picture of the OSCA channel gating cycle, uncover the importance of bound lipids and show that each subunit can open independently. This expands both our understanding of channel-mediated mechanotransduction and channel pore formation, with important mechanistic implications for the TMEM16 and TMC protein families.


Asunto(s)
Canales de Calcio , Microscopía por Crioelectrón , Activación del Canal Iónico , Mecanotransducción Celular , Humanos , Anoctaminas/química , Anoctaminas/metabolismo , Canales de Calcio/química , Canales de Calcio/metabolismo , Canales de Calcio/ultraestructura , Lípidos/química , Liposomas/metabolismo , Liposomas/química , Modelos Moleculares , Nanoestructuras/química
2.
J Physiol ; 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38098265

RESUMEN

The transient receptor potential melastatin 4 (TRPM4) channel contributes extensively to cardiac electrical activity, especially cardiomyocyte action potential formation. Mechanical stretch can induce changes in heart rate and rhythm, and the mechanosensitive channel Piezo1 is expressed in many cell types within the myocardium. Our previous study showed that TRPM4 and Piezo1 are closely co-localized in the t-tubules of ventricular cardiomyocytes and contribute to the Ca2+ -dependent signalling cascade that underlies hypertrophy in response to mechanical pressure overload. However, there was no direct evidence showing that Piezo1 activation was related to TRPM4 activation in situ. In the present study, we employed the HL-1 mouse atrial myocyte-like cell line as an in vitro model to investigate whether Piezo1-TRPM4 coupling can affect action potential properties. We used the small molecule Piezo1 agonist, Yoda1, as a surrogate for mechanical stretch to activate Piezo1 and detected the action potential changes in HL-1 cells using FluoVolt, a fluorescent voltage sensitive dye. Our results demonstrate that Yoda1-induced activation of Piezo1 changes the action potential frequency in HL-1 cells. This change in action potential frequency is reduced by Piezo1 knockdown using small intefering RNA. Importantly knockdown or pharmacological inhibition of TRPM4 significantly affected the degree to which Yoda1-evoked Piezo1 activation influenced action potential frequency. Thus, the present study provides in vitro evidence of a functional coupling between Piezo1 and TRPM4 in a cardiomyocyte-like cell line. The coupling of a mechanosensitive Ca2+ permeable channel and a Ca2+ -activated TRP channel probably represents a ubiquitous model for the role of TRP channels in mechanosensory transduction. KEY POINTS: The transient receptor potential melastatin 4 (TRPM4) and Piezo1 channels have been confirmed to contribute to the Ca2+ -dependent signalling cascade that underlies cardiac hypertrophy in response to mechanical pressure overload. However, there was no direct evidence showing that Piezo1 activation was related to TRPM4 activation in situ. We employed the HL-1 mouse atrial myocyte-like cell line as an in vitro model to investigate the effect of Piezo1-TRPM4 coupling on cardiac electrical properties. The results show that both pharmacological and genetic inhibition of TRPM4 significantly affected the degree to which Piezo1 activation influenced action potential frequency in HL-1 cells. Our findings provide in vitro evidence of a functional coupling between Piezo1 and TRPM4 in a cardiomyocyte-like cell line. The coupling of a mechanosensitive Ca2+ permeable channel and a Ca2+ -activated TRP channel probably represents a ubiquitous model for the role of TRP channels in mechanosensory transduction in various (patho)physiological processes.

3.
Biochem Soc Trans ; 51(5): 1897-1906, 2023 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-37772664

RESUMEN

Both integrin-mediated focal adhesions (FAs) and mechanosensitive ion channels such as PIEZO1 are critical in mechanotransduction processes that influence cell differentiation, development, and cancer. Ample evidence now exists for regulatory crosstalk between FAs and PIEZO1 channels with the molecular mechanisms underlying this process remaining unclear. However, an emerging picture is developing based on spatial crosstalk between FAs and PIEZO1 revealing a synergistic model involving the cytoskeleton, extracellular matrix (ECM) and calcium-dependent signaling. Already cell type, cell contractility, integrin subtypes and ECM composition have been shown to regulate this crosstalk, implying a highly fine-tuned relationship between these two major mechanosensing systems. In this review, we summarize the latest advances in this area, highlight the physiological implications of this crosstalk and identify gaps in our knowledge that will improve our understanding of cellular mechanosensing.


Asunto(s)
Integrinas , Neoplasias , Humanos , Integrinas/metabolismo , Mecanotransducción Celular/fisiología , Adhesiones Focales/metabolismo , Canales Iónicos/metabolismo
4.
Science ; 381(6659): 799-804, 2023 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-37590348

RESUMEN

Piezo channels are critical cellular sensors of mechanical forces. Despite their large size, ubiquitous expression, and irreplaceable roles in an ever-growing list of physiological processes, few Piezo channel-binding proteins have emerged. In this work, we found that MyoD (myoblast determination)-family inhibitor proteins (MDFIC and MDFI) are PIEZO1/2 interacting partners. These transcriptional regulators bind to PIEZO1/2 channels, regulating channel inactivation. Using single-particle cryogenic electron microscopy, we mapped the interaction site in MDFIC to a lipidated, C-terminal helix that inserts laterally into the PIEZO1 pore module. These Piezo-interacting proteins fit all the criteria for auxiliary subunits, contribute to explaining the vastly different gating kinetics of endogenous Piezo channels observed in many cell types, and elucidate mechanisms potentially involved in human lymphatic vascular disease.


Asunto(s)
Canales Iónicos , Factores Reguladores Miogénicos , Humanos , Microscopía por Crioelectrón , Células HEK293 , Activación del Canal Iónico , Canales Iónicos/química , Canales Iónicos/genética , Canales Iónicos/metabolismo , Cinética , Enfermedades Linfáticas/genética , Mutación , Factores Reguladores Miogénicos/química , Factores Reguladores Miogénicos/genética , Factores Reguladores Miogénicos/metabolismo , Dominios Proteicos , Mioblastos/metabolismo , Animales , Ratones
5.
Nat Commun ; 14(1): 3943, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37402734

RESUMEN

Mechanosensitive (MS) ion channels are a ubiquitous type of molecular force sensor sensing forces from the surrounding bilayer. The profound structural diversity in these channels suggests that the molecular mechanisms of force sensing follow unique structural blueprints. Here we determine the structures of plant and mammalian OSCA/TMEM63 proteins, allowing us to identify essential elements for mechanotransduction and propose roles for putative bound lipids in OSCA/TMEM63 mechanosensation. Briefly, the central cavity created by the dimer interface couples each subunit and modulates dimeric OSCA/TMEM63 channel mechanosensitivity through the modulating lipids while the cytosolic side of the pore is gated by a plug lipid that prevents the ion permeation. Our results suggest that the gating mechanism of OSCA/TMEM63 channels may combine structural aspects of the 'lipid-gated' mechanism of MscS and TRAAK channels and the calcium-induced gating mechanism of the TMEM16 family, which may provide insights into the structural rearrangements of TMEM16/TMC superfamilies.


Asunto(s)
Canales Iónicos , Mecanotransducción Celular , Animales , Mecanotransducción Celular/fisiología , Canales Iónicos/metabolismo , Lípidos/química , Mamíferos/metabolismo
6.
Biomed Mater ; 18(5)2023 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-37451254

RESUMEN

During the final stage of cancer metastasis, tumor cells embed themselves in distant capillary beds, from where they extravasate and establish secondary tumors. Recent findings underscore the pivotal roles of blood/lymphatic flow and shear stress in this intricate tumor extravasation process. Despite the increasing evidence, there is a dearth of systematic and biomechanical methodologies that accurately mimic intricate 3D microtissue interactions within a controlled hydrodynamic microenvironment. Addressing this gap, we introduce an easy-to-operate 3D spheroid-microvasculature-on-a-chip (SMAC) model. Operating under both static and regulated flow conditions, the SMAC model facilitates the replication of the biomechanical interplay between heterogeneous tumor spheroids and endothelium in a quantitative manner. Serving as anin vitromodel for metastasis mechanobiology, our model unveils the phenomena of 3D spheroid-induced endothelial compression and cell-cell junction degradation during tumor migration and expansion. Furthermore, we investigated the influence of shear stress on endothelial orientation, polarization, and tumor spheroid expansion. Collectively, our SMAC model provides a compact, cost-efficient, and adaptable platform for probing the mechanobiology of metastasis.


Asunto(s)
Neoplasias , Esferoides Celulares , Humanos , Neoplasias/patología , Microvasos , Endotelio , Dispositivos Laboratorio en un Chip , Microambiente Tumoral
8.
Nat Commun ; 13(1): 7467, 2022 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-36463216

RESUMEN

Piezo1 is a bona fide mechanosensitive ion channel ubiquitously expressed in mammalian cells. The distribution of Piezo1 within a cell is essential for various biological processes including cytokinesis, cell migration, and wound healing. However, the underlying principles that guide the subcellular distribution of Piezo1 remain largely unexplored. Here, we demonstrate that membrane curvature serves as a key regulator of the spatial distribution of Piezo1 in the plasma membrane of living cells. Piezo1 depletes from highly curved membrane protrusions such as filopodia and enriches to nanoscale membrane invaginations. Quantification of the curvature-dependent sorting of Piezo1 directly reveals the in situ nano-geometry of the Piezo1-membrane complex. Piezo1 density on filopodia increases upon activation, independent of calcium, suggesting flattening of the channel upon opening. Consequently, the expression of Piezo1 inhibits filopodia formation, an effect that diminishes with channel activation.


Asunto(s)
Calcio , Seudópodos , Animales , Membrana Celular , Movimiento Celular , Citocinesis , Mamíferos
9.
Sci Adv ; 8(45): eabo1461, 2022 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-36351022

RESUMEN

Mechanosensing is an integral part of many physiological processes including stem cell differentiation, fibrosis, and cancer progression. Two major mechanosensing systems-focal adhesions and mechanosensitive ion channels-can convert mechanical features of the microenvironment into biochemical signals. We report here unexpectedly that the mechanosensitive calcium-permeable channel Piezo1, previously perceived to be diffusive on plasma membranes, binds to matrix adhesions in a force-dependent manner, promoting cell spreading, adhesion dynamics, and calcium entry in normal but not in most cancer cells tested except some glioblastoma lines. A linker domain in Piezo1 is needed for binding to adhesions, and overexpression of the domain blocks Piezo1 binding to adhesions, decreasing adhesion size and cell spread area. Thus, we suggest that Piezo1 is a previously unidentified component of focal adhesions in nontransformed cells that catalyzes adhesion maturation and growth through force-dependent calcium signaling, but this function is absent in most cancer cells.

10.
ACS Appl Mater Interfaces ; 14(36): 40559-40568, 2022 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-36047858

RESUMEN

Piezo1 is a recently discovered Ca2+ permeable ion channel that has emerged as an integral sensor of hemodynamic forces within the cardiovascular system, contributing to vascular development and blood pressure regulation. However, how the composition of the extracellular matrix (ECM) affects the mechanosensitivity of Piezo1 in response to hemodynamic forces remains poorly understood. Using a combination of microfluidics and calcium imaging techniques, we probe the shear stress sensitivity of single HEK293T cells engineered to stably express Piezo1 in the presence of different ECM proteins. Our experiments show that Piezo1 sensitivity to shear stress is not dependent on the presence of ECM proteins. However, different ECM proteins regulate the sensitivity of Piezo1 depending on the shear stress level. Under high shear stress, fibronectin sensitizes Piezo1 response to shear, while under low shear stress, Piezo1 mechanosensitivity is improved in the presence of collagen types I and IV and laminin. Moreover, we report that α5ß1 and αvß3 integrins are involved in Piezo1 sensitivity at high shear, while αvß3 and αvß5 integrins are involved in regulating the Piezo1 response at low shear stress. These results demonstrate that the ECM/integrin interactions influence Piezo1 mechanosensitivity and could represent a mechanism whereby extracellular forces are transmitted to Piezo1 channels, providing new insights into the mechanism by which Piezo1 senses shear stress.


Asunto(s)
Canales Iónicos , Mecanotransducción Celular , Matriz Extracelular/metabolismo , Proteínas de la Matriz Extracelular/metabolismo , Células HEK293 , Humanos , Integrinas/metabolismo , Mecanotransducción Celular/fisiología
11.
Sci Rep ; 12(1): 9976, 2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-35705645

RESUMEN

Mechanosensitive (MS) ion channels are primary transducers of mechanical force into electrical and/or chemical intracellular signals. Many diverse MS channel families have been shown to respond to membrane forces. As a result of this intimate relationship with the membrane and proximal lipids, amphipathic compounds exert significant effects on the gating of MS channels. Here, we performed all-atom molecular dynamics (MD) simulations and employed patch-clamp recording to investigate the effect of two amphipaths, Fluorouracil (5-FU) a chemotherapy agent, and the anaesthetic trifluoroethanol (TFE) on structurally distinct mechanosensitive channels. We show that these amphipaths have a profound effect on the bilayer order parameter as well as transbilayer pressure profile. We used bacterial mechanosensitive channels (MscL/MscS) and a eukaryotic mechanosensitive channel (TREK-1) as force-from-lipids reporters and showed that these amphipaths have differential effects on these channels depending on the amphipaths' size and shape as well as which leaflet of the bilayer they incorporate into. 5-FU is more asymmetric in shape and size than TFE and does not penetrate as deep within the bilayer as TFE. Thereby, 5-FU has a more profound effect on the bilayer and channel activity than TFE at much lower concentrations. We postulate that asymmetric effects of amphipathic molecules on mechanosensitive membrane proteins through the bilayer represents a general regulatory mechanism for these proteins.


Asunto(s)
Proteínas de Escherichia coli , Humanos , Escherichia coli/metabolismo , Proteínas de Escherichia coli/metabolismo , Fluorouracilo/farmacología , Canales Iónicos/metabolismo , Membrana Dobles de Lípidos/química , Lípidos/farmacología , Mecanotransducción Celular , Trifluoroetanol/metabolismo
13.
Eur Biophys J ; 51(2): 135-146, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35286429

RESUMEN

Mechanical stimuli such as tension, compression, and shear stress play critical roles in the physiological functions of red blood cells (RBCs) and their homeostasis, ATP release, and rheological properties. Intracellular calcium (Ca2+) mobilization reflects RBC mechanosensing as they transverse the complex vasculature. Emerging studies have demonstrated the presence of mechanosensitive Ca2+ permeable ion channels and their function has been implicated in the regulation of RBC volume and deformability. However, how these mechanoreceptors trigger Ca2+ influx and subsequent cellular responses are still unclear. Here, we introduce a fluorescence-coupled micropipette aspiration assay to examine RBC mechanosensing at the single-cell level. To achieve a wide range of cell aspirations, we implemented and compared two negative pressure adjusting apparatuses: a homemade water manometer (- 2.94 to 0 mmH2O) and a pneumatic high-speed pressure clamp (- 25 to 0 mmHg). To visualize Ca2+ influx, RBCs were pre-loaded with an intensiometric probe Cal-520 AM, then imaged under a confocal microscope with concurrent bright-field and fluorescent imaging at acquisition rates of 10 frames per second. Remarkably, we observed the related changes in intracellular Ca2+ levels immediately after aspirating individual RBCs in a pressure-dependent manner. The RBC aspirated by the water manometer only displayed 1.1-fold increase in fluorescence intensity, whereas the RBC aspirated by the pneumatic clamp showed up to threefold increase. These results demonstrated the water manometer as a gentle tool for cell manipulation with minimal pre-activation, while the high-speed pneumatic clamp as a much stronger pressure actuator to examine cell mechanosensing directly. Together, this multimodal platform enables us to precisely control aspiration and membrane tension, and subsequently correlate this with intracellular calcium concentration dynamics in a robust and reproducible manner.


Asunto(s)
Calcio , Deformación Eritrocítica , Calcio/metabolismo , Eritrocitos , Canales Iónicos/metabolismo , Transducción de Señal
14.
Biol Rev Camb Philos Soc ; 97(2): 604-614, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34781417

RESUMEN

Piezo1 is a mechanosensitive ion channel with essential roles in cardiovascular, lung, urinary, and immune functions. Piezo1 is widely distributed in different tissues in the human body and its specific roles have been identified following a decade of research; however, not all are well understood. Many structural and functional characteristics of Piezo1 have been discovered and are known to differ greatly from the characteristics of other mechanosensitive ion channels. Understanding the mechanisms by which this ion channel functions may be useful in determining its physiological roles in various organ systems. This review provides insight into the signalling pathways activated by mechanical stimulation of Piezo1 in various organ systems and cell types. We discuss downstream targets of Piezo1 and the overall effects resulting from Piezo1 activation, which may provide insights into potential treatment targets for diseases involving this ion channel.


Asunto(s)
Sistema Cardiovascular , Canales Iónicos , Mecanotransducción Celular , Humanos , Canales Iónicos/metabolismo , Mecanotransducción Celular/fisiología , Transducción de Señal
15.
Front Pharmacol ; 12: 766416, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34867393

RESUMEN

Missense mutations in the gene that encodes for the mechanically-gated ion channel Piezo1 have been linked to a number of diseases. Gain-of-function variants are linked to a hereditary anaemia and loss-of-function variants have been linked to generalized lymphatic dysplasia and bicuspid aortic valve. Two previously characterized mutations, S217L and G2029R, both exhibit reduced plasma membrane trafficking. Here we show that both mutations also display reduced stability and higher turnover rates than wild-type Piezo1 channels. This occurs through increased ubiquitination and subsequent proteasomal degradation. Congruent with this, proteasome inhibition using N-acetyl-l-leucyl-l-leucyl-l-norleucinal (ALLN) reduced the degradation of both mutant proteins. While ALLN treatment could not rescue the function of S217L we show via multiple complementary methodologies that proteasome inhibition via ALLN treatment can not only prevent G2029R turnover but increase the membrane localized pool of this variant and the functional Piezo1 mechanosensitive currents. This data in combination with a precision medicine approach provides a new potential therapeutic avenue for the treatment of Piezo1 mediated channelopathies.

16.
J Struct Biol X ; 5: 100053, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34816118

RESUMEN

Mechanosensitive (MS) channels that are activated by the 'force-from-lipids' (FFL) principle rest in the membrane in a closed state but open a transmembrane pore in response to changes in the transmembrane pressure profile. The molecular implementations of the FFL principle vary widely between different MS channel families. The function of MS channels is often studied by patch-clamp electrophysiology, in which mechanical force or amphipathic molecules are used to activate the channels. Structural studies of MS channels in states other than the closed resting state typically relied on the use of mutant channels. Cyclodextrins (CDs) were recently introduced as a relatively easy and convenient approach to generate membrane tension. The principle is that CDs chelate hydrophobic molecules and can remove lipids from membranes, thus forcing the remaining lipids to cover more surface area and creating tension for membrane proteins residing in the membranes. CDs can be used to study the structure of MS channels in a membrane under tension by using single-particle cryo-electron microscopy to image the channels in nanodiscs after incubation with CDs as well as to characterize the function of MS channels by using patch-clamp electrophysiology to record the effect of CDs on channels inserted into membrane patches excised from proteoliposomes. Importantly, because incubation of membrane patches with CDs results in the activation of MscL, an MS channel that opens only shortly before membrane rupture, CD-mediated lipid removal appears to generate sufficient force to open most if not all types of MS channels that follow the FFL principle.

17.
Commun Biol ; 4(1): 1038, 2021 09 06.
Artículo en Inglés | MEDLINE | ID: mdl-34489534

RESUMEN

Mechanosensitive channels are integral membrane proteins that sense mechanical stimuli. Like most plasma membrane ion channel proteins they must pass through biosynthetic quality control in the endoplasmic reticulum that results in them reaching their destination at the plasma membrane. Here we show that N-linked glycosylation of two highly conserved asparagine residues in the 'cap' region of mechanosensitive Piezo1 channels are necessary for the mature protein to reach the plasma membrane. Both mutation of these asparagines (N2294Q/N2331Q) and treatment with an enzyme that hydrolyses N-linked oligosaccharides (PNGaseF) eliminates the fully glycosylated mature Piezo1 protein. The N-glycans in the cap are a pre-requisite for N-glycosylation in the 'propeller' regions, which are present in loops that are essential for mechanotransduction. Importantly, trafficking-defective Piezo1 variants linked to generalized lymphatic dysplasia and bicuspid aortic valve display reduced fully N-glycosylated Piezo1 protein. Thus the N-linked glycosylation status in vitro correlates with efficient membrane trafficking and will aid in determining the functional impact of Piezo1 variants of unknown significance.


Asunto(s)
Activación del Canal Iónico , Canales Iónicos/genética , Mecanotransducción Celular , Mutación , Membrana Celular/metabolismo , Glicosilación , Humanos , Canales Iónicos/metabolismo
18.
Proc Natl Acad Sci U S A ; 118(36)2021 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-34475213

RESUMEN

The bacterial mechanosensitive channel of small conductance (MscS) has been extensively studied to understand how mechanical forces are converted into the conformational changes that underlie mechanosensitive (MS) channel gating. We showed that lipid removal by ß-cyclodextrin can mimic membrane tension. Here, we show that all cyclodextrins (CDs) can activate reconstituted Escherichia coli MscS, that MscS activation by CDs depends on CD-mediated lipid removal, and that the CD amount required to gate MscS scales with the channel's sensitivity to membrane tension. Importantly, cholesterol-loaded CDs do not activate MscS. CD-mediated lipid removal ultimately causes MscS desensitization, which we show is affected by the lipid environment. While many MS channels respond to membrane forces, generalized by the "force-from-lipids" principle, their different molecular architectures suggest that they use unique ways to convert mechanical forces into conformational changes. To test whether CDs can also be used to activate other MS channels, we chose to investigate the mechanosensitive channel of large conductance (MscL) and demonstrate that CDs can also activate this structurally unrelated channel. Since CDs can open the least tension-sensitive MS channel, MscL, they should be able to open any MS channel that responds to membrane tension. Thus, CDs emerge as a universal tool for the structural and functional characterization of unrelated MS channels.


Asunto(s)
Ciclodextrinas/metabolismo , Canales Iónicos/metabolismo , Mecanotransducción Celular/fisiología , Membrana Celular/fisiología , Escherichia coli/metabolismo , Proteínas de Escherichia coli/metabolismo , Membrana Dobles de Lípidos , Tensión Superficial
19.
Sci Rep ; 11(1): 13712, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-34211012

RESUMEN

We present mathematical simulations of shapes of red blood cells (RBCs) and their cytoskeleton when they are subjected to linear strain. The cell surface is described by a previously reported quartic equation in three dimensional (3D) Cartesian space. Using recently available functions in Mathematica to triangularize the surfaces we computed four types of curvature of the membrane. We also mapped changes in mesh-triangle area and curvatures as the RBCs were distorted. The highly deformable red blood cell (erythrocyte; RBC) responds to mechanically imposed shape changes with enhanced glycolytic flux and cation transport. Such morphological changes are produced experimentally by suspending the cells in a gelatin gel, which is then elongated or compressed in a custom apparatus inside an NMR spectrometer. A key observation is the extent to which the maximum and minimum Principal Curvatures are localized symmetrically in patches at the poles or equators and distributed in rings around the main axis of the strained RBC. Changes on the nanometre to micro-meter scale of curvature, suggest activation of only a subset of the intrinsic mechanosensitive cation channels, Piezo1, during experiments carried out with controlled distortions, which persist for many hours. This finding is relevant to a proposal for non-uniform distribution of Piezo1 molecules around the RBC membrane. However, if the curvature that gates Piezo1 is at a very fine length scale, then membrane tension will determine local curvature; so, curvatures as computed here (in contrast to much finer surface irregularities) may not influence Piezo1 activity. Nevertheless, our analytical methods can be extended address these new mechanistic proposals. The geometrical reorganization of the simulated cytoskeleton informs ideas about the mechanism of concerted metabolic and cation-flux responses of the RBC to mechanically imposed shape changes.


Asunto(s)
Membrana Eritrocítica , Eritrocitos/citología , Algoritmos , Fenómenos Biomecánicos , Forma de la Célula , Simulación por Computador , Deformación Eritrocítica , Membrana Eritrocítica/metabolismo , Eritrocitos/metabolismo , Humanos , Modelos Biológicos , Estrés Mecánico , Propiedades de Superficie
20.
Elife ; 102021 06 30.
Artículo en Inglés | MEDLINE | ID: mdl-34190686

RESUMEN

Pathological left ventricular hypertrophy (LVH) occurs in response to pressure overload and remains the single most important clinical predictor of cardiac mortality. The molecular pathways in the induction of pressure overload LVH are potential targets for therapeutic intervention. Current treatments aim to remove the pressure overload stimulus for LVH, but do not completely reverse adverse cardiac remodelling. Although numerous molecular signalling steps in the induction of LVH have been identified, the initial step by which mechanical stretch associated with cardiac pressure overload is converted into a chemical signal that initiates hypertrophic signalling remains unresolved. In this study, we show that selective deletion of transient receptor potential melastatin 4 (TRPM4) channels in mouse cardiomyocytes results in an approximately 50% reduction in the LVH induced by transverse aortic constriction. Our results suggest that TRPM4 channel is an important component of the mechanosensory signalling pathway that induces LVH in response to pressure overload and represents a potential novel therapeutic target for the prevention of pathological LVH.


Asunto(s)
Eliminación de Gen , Hipertrofia Ventricular Izquierda/genética , Miocitos Cardíacos/metabolismo , Canales Catiónicos TRPM/genética , Animales , Hipertrofia Ventricular Izquierda/metabolismo , Masculino , Ratones , Ratones Endogámicos C57BL , Transducción de Señal , Canales Catiónicos TRPM/efectos adversos , Canales Catiónicos TRPM/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA