Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
ACS Appl Mater Interfaces ; 16(42): 57695-57704, 2024 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-39396246

RESUMEN

A precise recording of electrophysiological signals requires high-performance flexible bioelectrodes to build a robust skin interface. The past decade has witnessed encouraging progress in the development of elastomeric electrodes for wearable electrophysiological monitoring; however, it remains challenging to achieve excellent flexibility, conformal contact, and high durability simultaneously. Herein, we report on an effective method to fabricate flexible yet durable microneedle electrodes (MEs) based on vertically aligned gold nanowires (Au NWs) embedded polyimide (PI), which meet the above three design requirements. The Au NWs embedded PI MEs could build conformal contact with human skin and maintain electrical stability with minimal contact impedance by effectively penetrating the stratum corneum of the skin. In comparison studies, we found our MEs outperformed conventional gel or elastomeric soft electrodes. We further integrated the vertical Au-NW MEs into a wearable healthcare system and achieved wireless real-time recordings of electromyography (EMG) and electrocardiography (ECG) with high signal-to-noise ratios (SNRs) and low motion artifacts. Our fabrication strategy opens a new route to improve the durability and reliability of emerging nanomaterial-based soft bioelectrodes for long-term wearable healthcare applications.


Asunto(s)
Electrodos , Oro , Nanocables , Dispositivos Electrónicos Vestibles , Nanocables/química , Humanos , Oro/química , Electromiografía/instrumentación , Agujas , Electrocardiografía/instrumentación , Resinas Sintéticas/química
2.
Sensors (Basel) ; 24(20)2024 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-39460182

RESUMEN

Passive wireless surface acoustic wave (SAW) sensors are very useful for on-site monitoring of the working status of machines in complex environments, such as high-temperature rotating objects. For rotating parts, it is difficult to realize real-time and continuous monitoring because of the unstable sensing signal caused by the continuous change of the relative position of the rotating part to the sensor and shielding of the signal. In our SAW sensing system, we propose a loop antenna integrated with the rotating part to obtain a stable sensing signal owing to its omnidirectional radiation pattern. Methodologies for determining the antenna dimension, system operating frequency, and procedures for designing a SAW sensor tag are discussed in this paper. By fully utilizing the influence of metal rotor on antenna performance, the antenna needs no impedance matching elements while it provides sufficient gain, which equips the antenna with nearly zero temperature drift at a wide temperature-sensing range. Experimental verification results show that this sensing system can greatly improve the stability of the sensing signal significantly and can achieve a temperature sensing accuracy of ~1 °C at different rotational speeds, demonstrated by the feasibility of the loop antenna for monitoring the working status of rotating metal parts.

3.
Sensors (Basel) ; 24(15)2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39123894

RESUMEN

Synchronous monitoring electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) have received significant attention in brain science research for their provision of more information on neuro-loop interactions. There is a need for an integrated hybrid EEG-fNIRS patch to synchronously monitor surface EEG and deep brain fNIRS signals. Here, we developed a hybrid EEG-fNIRS patch capable of acquiring high-quality, co-located EEG and fNIRS signals. This patch is wearable and provides easy cognition and emotion detection, while reducing the spatial interference and signal crosstalk by integration, which leads to high spatial-temporal correspondence and signal quality. The modular design of the EEG-fNIRS acquisition unit and optimized mechanical design enables the patch to obtain EEG and fNIRS signals at the same location and eliminates spatial interference. The EEG pre-amplifier on the electrode side effectively improves the acquisition of weak EEG signals and significantly reduces input noise to 0.9 µVrms, amplitude distortion to less than 2%, and frequency distortion to less than 1%. Detrending, motion correction algorithms, and band-pass filtering were used to remove physiological noise, baseline drift, and motion artifacts from the fNIRS signal. A high fNIRS source switching frequency configuration above 100 Hz improves crosstalk suppression between fNIRS and EEG signals. The Stroop task was carried out to verify its performance; the patch can acquire event-related potentials and hemodynamic information associated with cognition in the prefrontal area.


Asunto(s)
Encéfalo , Electroencefalografía , Espectroscopía Infrarroja Corta , Dispositivos Electrónicos Vestibles , Humanos , Electroencefalografía/métodos , Electroencefalografía/instrumentación , Espectroscopía Infrarroja Corta/métodos , Encéfalo/fisiología , Encéfalo/diagnóstico por imagen , Masculino , Adulto , Femenino , Procesamiento de Señales Asistido por Computador , Algoritmos , Adulto Joven
4.
Micromachines (Basel) ; 15(5)2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38793128

RESUMEN

Continuous monitoring of vital signs based on advanced sensing technologies has attracted extensive attention due to the ravages of COVID-19. A maintenance-free and low-cost passive wireless sensing system based on surface acoustic wave (SAW) device can be used to continuously monitor temperature. However, the current SAW-based passive sensing system is mostly designed at a low frequency around 433 MHz, which leads to the relatively large size of SAW devices and antenna, hindering their application in wearable devices. In this paper, SAW devices with a resonant frequency distributed in the 870 MHz to 960 MHz range are rationally designed and fabricated. Based on the finite-element method (FEM) and coupling-of-modes (COM) model, the device parameters, including interdigital transducer (IDT) pairs, aperture size, and reflector pairs, are systematically optimized, and the theoretical and experimental results show high consistency. Finally, SAW temperature sensors with a quality factor greater than 2200 are obtained for real-time temperature monitoring ranging from 20 to 50 °C. Benefitting from the higher operating frequency, the size of the sensing system can be reduced for human body temperature monitoring, showing its potential to be used as a wearable monitoring device in the future.

5.
Nat Commun ; 15(1): 2270, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38491004

RESUMEN

The success of macrophage-based adoptive cell therapy is largely constrained by poor polarization from alternatively activated (M2-like) to classically activated (M1-like) phenotype in the immunosuppressive tumor microenvironment (TME). Here, we show that the engineered macrophage (eMac) with a heat-inducible genetic switch can induce both self-polarization of adoptively transferred eMac and re-polarization of tumour-associated macrophages in response to mild temperature elevation in a mouse model. The locoregional production of proinflammatory cytokines by eMac in the TME dose not only induces the strong polarization of macrophages into a classically activated phenotype, but also ensures that the side effects typical for systemically administrate proinflammatory cytokines are avoided. We also present a wearable warming device which is adaptable for human patients and can be remotely controlled by a smartphone. In summary, our work represents a safe and efficient adoptive transfer immunotherapy method with potential for human translation.


Asunto(s)
Neoplasias , Microambiente Tumoral , Ratones , Animales , Humanos , Calor , Macrófagos , Citocinas/farmacología , Neoplasias/terapia , Inmunoterapia
6.
Biomicrofluidics ; 18(1): 011303, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38362304

RESUMEN

The robust identification and quantification of various biomarkers is of utmost significance in clinical diagnostics and precision medicine. Fluorescent immunoassays are widely used and considered as a gold standard for biomarker detection due to their high specificity and accuracy. However, current commercial immunoassay tests suffer from limited detection sensitivity and complicated, labor-intensive operation procedures, making them impractical for point-of-care diagnosis, particularly in resource-limited regions. Recently, microfluidic immunoassay devices integrated with plasmonic nanostructures have emerged as a powerful tool for sensitive detection of biomarkers, addressing specific issues, such as integration schemes, easy operation, multiplexed detection, and sensitivity enhancement. In this paper, we provide a discussion on the recent advances in the plasmonic nanostructures integrated with microfluidic devices for fluorescent immunoassays. We shed light on the nanofabrication strategies and various fluidic designs for rapid, sensitive, and highly efficient sensing of antigens. Finally, we share our perspectives on the potential directions of these integrated devices for practical applications.

7.
Nanomaterials (Basel) ; 14(3)2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38334511

RESUMEN

Advancements in brain-machine interfaces and neurological treatments urgently require the development of improved brain electrodes applied for long-term implantation, where traditional and polymer options face challenges like size, tissue damage, and signal quality. Carbon nanotubes are emerging as a promising alternative, combining excellent electronic properties and biocompatibility, which ensure better neuron coupling and stable signal acquisition. In this study, a new flexible brain electrode array based on 99.99% purity of single-walled carbon nanotubes (SWCNTs) was developed, which has 30 um × 40 um size, about 5.1 kΩ impedance, and 14.01 dB signal-to-noise ratio (SNR). The long-term implantation experiment in vivo in mice shows the proposed brain electrode can maintain stable LFP signal acquisition over 12 weeks while still achieving an SNR of 3.52 dB. The histological analysis results show that SWCNT-based brain electrodes induced minimal tissue damage and showed significantly reduced glial cell responses compared to platinum wire electrodes. Long-term stability comes from SWCNT's biocompatibility and chemical inertness, the electrode's flexible and fine structure. Furthermore, the new brain electrode array can function effectively during 7-Tesla magnetic resonance imaging, enabling the collection of local field potential and even epileptic discharges during the magnetic scan. This study provides a comprehensive study of carbon nanotubes as invasive brain electrodes, providing a new path to address the challenge of long-term brain electrode implantation.

8.
Polymers (Basel) ; 16(1)2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38201815

RESUMEN

Poly(vinylidene fluoride-trifluorethylene) (P(VDF-TrFE)) has promising potential applications in radio-frequency filters due to their excellent piezoelectric properties, flexibility, and stability. In this paper, a flexible film bulk acoustic wave filter is investigated based on P(VDF-TrFE) as piezoelectric film. A new method based on three-step annealing is developed to efficiently remove the porosity inside the P(VDF-TrFE) films so as to improve its properties. The obtained film achieved high ß-phase content beyond 80% and a high piezoelectric coefficient of 27.75 pm/V. Based on the low porosity ß-phase films, a flexible wide-band RF filter is designed, which consists of a bulk acoustic wave resonator and lumped inductor-capacitor elements as a hybrid configuration. The resonator sets the filter's center frequency, while the lumped LC-based matching network extends the bandwidth and enhances out-of-band rejection. The testing results of the proposed wide-band filter show its good performance, with 12.5% fractional bandwidth and an insertion loss of 3.1 dB. To verify the possibility of folding and stacking the flexible bulk acoustic wave devices for high-density multi-filter integration in MIMO communication, bending tests of the filter are also conducted with the bending strain range up to 5500 µÎµ. The testing results show no noticeable performance degradation after four bending cycles. This work demonstrates the potential of ß-phase P(VDF-TrFE) bulk acoustic wave filters to expand the scope of future flexible radio-frequency filter applications.

9.
ACS Appl Mater Interfaces ; 16(1): 1492-1501, 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38153799

RESUMEN

Piezoelectric poly(vinylidene fluoride) (PVDF) and its copolymers have been widely investigated for applications in wearable electric devices and sensing systems, owing to their intrinsic piezoelectricity and superior flexibility. However, their weak piezoelectricity poses major challenges for practical applications. To overcome these challenges, we propose a two-step synthesis approach to fabricate sandwich-structured piezoelectric films (BaTiO3@PDA/PVDF/BaTiO3@PDA) with significantly enhanced ferroelectric and piezoelectric properties. As compared to pristine PVDF films or conventional 0-3 composite films, a maximum polarization (Pmax) of 11.24 µC/cm2, a remanent polarization (Pr) of 5.83 µC/cm2, and an enhanced piezoelectric coefficient (d33 ∼ 14.6 pC/N) were achieved. Simulation and experimental results have demonstrated that the sandwich structure enhances the ability of composite films to withstand higher poling electric fields in comparison with 0-3 composites. The sandwich-structured piezoelectric films are further integrated into a wireless sensor system with a high force sensitivity of 288 mV/N, demonstrating great potential for movement monitoring applications. This facile approach shows great promise for the large-scale production of composite films with remarkable flexibility, ferroelectricity, and piezoelectricity for wearable sensing devices.

10.
Micromachines (Basel) ; 14(11)2023 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-38004943

RESUMEN

In this work, a longitudinally excited shear-wave resonator (YBAR) based on single-crystalline lithium tantalate (LiTaO3, LT) thin film is proposed. The YBAR has a 200 nm X-cut thin film and molybdenum electrode. A high effective electromechanical coupling coefficient (k2eff) of up to 19% for the suspension-type structure was obtained. Furthermore, a Bragg reflector (SiO2/Pt) with optimized layer thickness ratio was employed to improve the performance of the YBAR. Compared to the acoustic wave resonators with the conventional quarter-wave (λ/4) Bragg reflector, the proposed YBAR with an optimized Bragg reflector can reflect both the longitudinal and shear waves efficiently, and resonators with spurious-free response and high quality (Q) value were achieved. This work provides a potential solution to enabling high coupling micro-acoustic resonators with high Q factor in the 5G/6G communication system.

11.
Anal Chem ; 95(36): 13586-13595, 2023 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-37624148

RESUMEN

In this paper, we present a highly effective microfluidic emulsion system using an integrated microchannel plate (MCP), a porous glass membrane that is readily available and densely packs millions of through-microchannels, for high-throughput production of monodisperse droplets. The physical controls of droplet formation, including viscosity, flow rate, and pore size, have been extensively explored for optimum emulsification conditions. The performance of the device has been validated where monodisperse droplets with a narrow coefficient of variance (<5%) can be achieved at a dispersed phase flux of 3 mL h-1 from a piece of 4 × 4 mm2 MCP. The average droplet size is two times the nominal membrane pore diameter and thus can be easily controlled by choosing the appropriate membrane type. The preparation of hydrogel microspheres has also been demonstrated with a high throughput of 1.5 × 106 particles min-1. These microspheres with a uniform size range and rough surface morphology provide suitable bioenvironments and serve as ideal carriers for cell culture. Mouse fibroblasts are shown to be cultured on these 3D scaffolds with an average cell viability of over 96%. The cell attachment rate can reach up to 112 ± 7% in 24 h and the proliferation ability increases with the number of culture days. Furthermore, the device has been applied in the droplet digital polymerase chain reaction for absolute quantification of lung cancer-related PLAU genes. The detection limit achieved was noted to be 0.5 copies/µL with a dynamic range of 105 ranging from 1 × 102 to 1 × 106 copies/µL. Given the easy fabrication, robust performance, and simple operation, the emulsion system sets the stage for the laboratory's droplet-based assays and applications in tissue engineering.


Asunto(s)
Hidrogeles , Microfluídica , Animales , Ratones , Microesferas , Emulsiones , Vendajes
12.
Microsyst Nanoeng ; 9: 72, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37283782

RESUMEN

Miniaturized gas pumps based on electromagnetic effect have been intensively studied and widely applied in industries. However, the electromagnetic effect-based gas pumps normally have large sizes, high levels of noises and high power consumption, thus they are not suitable for wearable/portable applications. Herein, we propose a high-flowrate and high-pressure load valveless piezoelectric micropump with dimensions of 16 mm*16 mm*5 mm. The working frequency, vibration mode and displacement of the piezoelectric actuator, the velocity of gas flow, and the volume flowrate of the micropump are analyzed using the finite element analysis method. The maximum vibration amplitude of the piezoelectric actuator reaches ~29.4 µm. The output gas flowrate of the pump is approximately 135 mL/min, and the maximum output pressure exceeds 40 kPa. Then, a prototype of the piezoelectric micropump is fabricated. Results show that performance of the micropump is highly consistent with the numerical analysis with a high flowrate and pressure load, demonstrated its great potential for wearable/portable applications, especially for blood pressure monitoring.

13.
Biosensors (Basel) ; 13(4)2023 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-37185558

RESUMEN

Sleep apnea syndrome (SAS) is a common but underdiagnosed health problem related to impaired quality of life and increased cardiovascular risk. In order to solve the problem of complicated and expensive operation procedures for clinical diagnosis of sleep apnea, here we propose a small and low-cost wearable apnea diagnostic system. The system uses a photoplethysmography (PPG) optical sensor to collect human pulse wave signals and blood oxygen saturation synchronously. Then multiscale entropy and random forest algorithms are used to process the PPG signal for analysis and diagnosis of sleep apnea. The SAS determination is based on the comprehensive diagnosis of the PPG signal and blood oxygen saturation signal, and the blood oxygen is used to exclude the error induced by non-pathological factors. The performance of the system is compared with the Compumedics Grael PSG (Polysomnography) sleep monitoring system. This simple diagnostic system provides a feasible technical solution for portable and low-cost screening and diagnosis of SAS patients with a high accuracy of over 85%.


Asunto(s)
Síndromes de la Apnea del Sueño , Dispositivos Electrónicos Vestibles , Humanos , Calidad de Vida , Síndromes de la Apnea del Sueño/diagnóstico , Polisomnografía/métodos , Aprendizaje Automático , Fotopletismografía/métodos
14.
Nanotechnology ; 34(29)2023 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-37075709

RESUMEN

The performance of the Graphene/Si (Gr/Si) Schottky interface and its potential in future electronics strongly rely on the quality of interconnecting contacts with external circuitry. In this work, we investigate the dominating and limiting factors of Gr/Si interfaces designed for high light absorption, paying particular attention to the nature of the contact failure under high electrostatic discharge (ESD) conditions. Our findings indicate that severe current crowding at contact edges of the graphene is the dominating factor for the device breakdown. Material degradation and electrical breakdown are systematically analyzed by atomic force, Raman, scanning electron, and energy-dispersive x-ray spectroscopies. This work enlists the robustness and limitations of Gr/Si junction in photodiode architecture under high ESD conditions that can be used as general guidelines for 2D-3D electronic and optoelectronic devices.

15.
Diagnostics (Basel) ; 13(6)2023 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-36980466

RESUMEN

The pelvic floor dysfunction (PFD) has become a serious public health problem. Accurate diagnosis of regional pelvic floor muscle (PFM) malfunctions is vitally important for the prevention and treatment of PFD. However, there is a lack of reliable diagnostic devices to evaluate and diagnose regional PFM abnormality. In this work, we developed a multifunctional evaluation technology (MET) based on a novel airbag-type stretchable electrode array probe (ASEA) for the diagnosis of malfunctions of regional PFM. The inflatable ASEA has specifically distributed 32 electrodes along the muscles, and is able to adapt to different human bodies for tight contact with the muscles. These allow synchronous collection of high-quality multi-channel surface electromyography (MC-sEMG) signals, and then are used to diagnose regional PFM malfunctions and evaluate inter-regional correlation. Clinical trial was conducted on 15 postpartum stress urinary incontinence (PSUI) patients and 15 matched asymptomatic women. Results showed that SUI patients responded slowly to the command and have symptoms of muscle strength degeneration. The results were consistent with the relevant clinical manifestations, and proved the reliability of MET for multifunctional PFM evaluation. Furthermore, the MET can diagnose malfunctions of regional PFM, which is inaccessible with existing technology. The results also showed that the dysfunction of PSUI patients is mainly located in iliococcygeus, pubococcygeus, and urethral sphincter regions, and there is a weak correlation between these specific regions and nearby regions. In conclusion, MET provides a point-of-care diagnostic method for abnormal function of regional PFM, which has a potential for the targeted point-to-point electrical stimulation treatment and PFD pathology research.

16.
Sensors (Basel) ; 23(5)2023 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-36904975

RESUMEN

The manipulation of biomedical particles, such as separating circulating tumor cells from blood, based on standing surface acoustic wave (SSAW) has been widely used due to its advantages of label-free approaches and good biocompatibility. However, most of the existing SSAW-based separation technologies are dedicated to isolate bioparticles in only two different sizes. It is still challenging to fractionate various particles in more than two different sizes with high efficiency and accuracy. In this work, to tackle the problems of low efficiency for multiple cell particle separation, integrated multi-stage SSAW devices with different wavelengths driven by modulated signals were designed and studied. A three-dimensional microfluidic device model was proposed and analyzed using the finite element method (FEM). In addition, the effect of the slanted angle, acoustic pressure, and the resonant frequency of the SAW device on the particle separation were systemically studied. From the theoretical results, the separation efficiency of three different size particles based on the multi-stage SSAW devices reached 99%, which was significantly improved compared with conventional single-stage SSAW devices.

17.
Lab Chip ; 23(8): 1981-2004, 2023 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-36946437

RESUMEN

DNA has been considered a promising alternative to the current solid-state devices for digital information storage. The past decade has witnessed tremendous progress in the field of DNA data storage contributed by researchers from various disciplines. However, the current development status of DNA storage is still far from practical use, mainly due to its high material cost and time consumption for data reading/writing, as well as the lack of a comprehensive, automated, and integrated system. Microfluidics, being capable of handling and processing micro-scale fluid samples in a massively paralleled and highly integrated manner, has gradually been recognized as a promising candidate for addressing the aforementioned issues. In this review, we provide a discussion on recent efforts of applying microfluidics to advance the development of DNA data storage. Moreover, to showcase the tremendous potential that microfluidics can contribute to this field, we will further highlight the recent advancements of applying microfluidics to the key functional modules within the DNA data storage workflow. Finally, we share our perspectives on future directions for how to continue the infusion of microfluidics with DNA data storage and how to advance toward a truly integrated system and reach real-life applications.


Asunto(s)
ADN , Microfluídica , Almacenamiento y Recuperación de la Información
18.
Sensors (Basel) ; 23(4)2023 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-36850733

RESUMEN

P(VDF-TrFE) is a promising material for flexible acoustic devices owing to its good piezoelectric performance and excellent stretchability. However, the high density of internal pores and large surface roughness of the conventional P(VDF-TrFE) results in a high propagation attenuation for acoustic waves, which limits its use in flexible acoustic devices. In this paper, a novel method based on two-step annealing is proposed to effectively remove the pores inside the P(VDF-TrFE) film and reduce its surface roughness. The obtained P(VDF-TrFE) film possesses excellent characteristics, including a high breakdown strength of >300 kV/mm, a high-purity ß-phase content of more than 80%, and high piezoelectric coefficients (d33) of 42 pm/V. Based on the low-porosity ß-phase P(VDF-TrFE) film, we fabricated flexible film bulk acoustic resonators (FBARs) which exhibit high sharp resonance peaks. The pressure sensor was made by sandwiching the FBARs with two PDMS microneedle patches. Heartbeat and respiration rate monitoring were achieved using the pressure sensor. This work demonstrates the feasibility of high-performance flexible piezoelectric acoustic resonators based on low-porosity P(VDF-TrFE) films, which could see wider applications in the wearable sensors for both physical and chemical sensing.

19.
ACS Appl Mater Interfaces ; 15(3): 4652-4667, 2023 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-36698266

RESUMEN

Tendon injuries are some of the most commonly diagnosed musculoskeletal diseases. Tendon regeneration is sensitive to the topology of the substitute as it affects the cellular microenvironment and homeostasis. To bionic in vivo three-dimensional (3D) aligned microenvironment, an ordered 3D sandwich model was used to investigate the cell response in the tendon. First, high-resolution 3D printing provided parallel-grooved topographical cues on the hydrogel surface. Then the cells were seeded on its surface to acquire a 2D model. Afterward, an additional hydrogel coating layer was applied to the cells to create the 3D model. The interaction between cells and order structures in three-dimensions is yet to be explored. The study found that the tendon stem/progenitor cells (TSPCs) still maintain their ordering growth in the 3D model as in the 2D model. The study also found that the 3D-aligned TSPCs exhibited enhanced tenogenic differentiation through the PI3K-AKT signaling pathway and presented a less inflammatory phenotype than those in the 2D model. The in vivo implantation of such a 3D-aligned TSPC composite promoted tendon regeneration and mitigated heterotopic ossification in an Achilles defect model. These findings demonstrated that 3D-aligned TSPCs within a biomimetic topology environment are promising for functional tendon regeneration.


Asunto(s)
Tendón Calcáneo , Andamios del Tejido , Andamios del Tejido/química , Ingeniería de Tejidos/métodos , Biomimética , Fosfatidilinositol 3-Quinasas , Células Madre , Diferenciación Celular , Hidrogeles/química , Regeneración
20.
Adv Sci (Weinh) ; 10(2): e2204467, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36403238

RESUMEN

Active electrocorticogram (ECoG) electrodes can amplify weak electrophysiological signals and improve anti-interference ability; however, traditional active electrodes are opaque and cannot realize photoelectric collaborative observation. In this study, an active and fully transparent ECoG array based on zinc oxide thin-film transistors (ZnO TFTs) is developed as a local neural signal amplifier for electrophysiological monitoring. The transparency of the proposed ECoG array is up to 85%, which is superior to that of the previously reported active electrode arrays. Various electrical characterizations have demonstrated its ability to record electrophysiological signals with a higher signal-to-noise ratio of 19.9 dB compared to the Au grid (13.2 dB). The high transparency of the ZnO-TFT electrode array allows the concurrent collection of high-quality electrophysiological signals (32.2 dB) under direct optical stimulation of the optogenetic mice brain. The ECoG array can also work under 7-Tesla magnetic resonance imaging to record local brain signals without affecting brain tissue imaging. As the most transparent active ECoG array to date, it provides a powerful multimodal tool for brain observation, including recording brain activity under synchronized optical modulation and 7-Tesla magnetic resonance imaging.


Asunto(s)
Óxido de Zinc , Ratones , Animales , Electrocorticografía , Electrodos , Encéfalo/fisiología , Mapeo Encefálico/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...