Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
ACS Meas Sci Au ; 4(3): 247-259, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38910860

RESUMEN

Precision medicine is a new medical approach which considers both population characteristics and individual variability to provide customized healthcare. The transition from traditional reactive medicine to personalized medicine is based on a biomarker-driven process and a deep knowledge of biological mechanisms according to which the development of diseases occurs. In this context, the advancements in high-throughput omics technologies represent a unique opportunity to discover novel biomarkers and to provide an unbiased picture of the biological system. One of the medical fields in which omics science has started to be recently applied is that of ophthalmology. Ocular diseases are very common, and some of them could be highly disabling, thus leading to vision loss and blindness. The pathogenic mechanism of most ocular diseases may be dependent on various genetic and environmental factors, whose effect has not been yet completely understood. In this context, large-scale omics approaches are fundamental to have a comprehensive evaluation of the whole system and represent an essential tool for the development of novel therapies. This Review summarizes the recent advancements in omics science applied to ophthalmology in the last ten years, in particular by focusing on proteomics, metabolomics and lipidomics applications from an analytical perspective. The role of high-efficiency separation techniques coupled to (high-resolution) mass spectrometry ((HR)MS) is also discussed, as well as the impact of sampling, sample preparation and data analysis as integrating parts of the analytical workflow.

2.
Anal Bioanal Chem ; 416(18): 4091-4099, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38748248

RESUMEN

In the present study, twin-column recycling chromatography has been employed for the purification of a Cannabis extract by using a green solvent, ethanol, as the mobile phase. In particular, the complete removal of the psychoactive tetrahydrocannabinol (THC) from a Cannabis extract rich in cannabidiol (CBD) was achieved under continuous conditions. The performance of the method, in terms of compound purity, recovery, productivity and solvent consumption, was compared to that of traditional batch operations showing the potential of the twin-column recycling approach. The employment of a theoretical model to predict the band profiles of the two compounds during the recycling process has facilitated method development, thus further contributing to process sustainability by avoiding trial and error attempts or at least decreasing the number of steps significantly.


Asunto(s)
Cannabinoides , Cannabis , Tecnología Química Verde , Solventes , Solventes/química , Cannabinoides/aislamiento & purificación , Cannabinoides/análisis , Cannabinoides/química , Tecnología Química Verde/métodos , Cannabis/química , Reciclaje , Extractos Vegetales/química , Extractos Vegetales/aislamiento & purificación , Cannabidiol/aislamiento & purificación , Cannabidiol/análisis , Dronabinol/aislamiento & purificación , Dronabinol/análisis , Cromatografía Líquida de Alta Presión/métodos
3.
Anal Bioanal Chem ; 416(16): 3797-3809, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38702447

RESUMEN

The increasing interest in hemp and cannabis poses new questions about the influence of drying and storage conditions on the overall aroma and cannabinoids profile of these products. Cannabis inflorescences are subjected to drying shortly after harvest and then to storage in different containers. These steps may cause a process of rapid deterioration with consequent changes in precious secondary metabolite content, negatively impacting on the product quality and potency. In this context, in this work, the investigation of the effects of freeze vs tray drying and three storage conditions on the preservation of cannabis compounds has been performed. A multi-trait approach, combining both solid-phase microextraction (SPME) two-dimensional gas chromatography coupled to mass spectrometry (SPME-GC × GC-MS) and high-performance liquid chromatography (HPLC), is presented for the first time. This approach has permitted to obtain the detailed characterisation of the whole cannabis matrix in terms of volatile compounds and cannabinoids. Moreover, multivariate statistical analyses were performed on the obtained data, helping to show that freeze drying conditions is useful to preserve cannabinoid content, preventing decarboxylation of acid cannabinoids, but leads to a loss of volatile compounds which are responsible for the cannabis aroma. Furthermore, among storage conditions, storage in glass bottle seems more beneficial for the retention of the initial VOC profile compared to open to air dry tray and closed high-density polyethylene box. However, the glass bottle storage condition causes formation of neutral cannabinoids at the expenses of the highly priced acid forms. This work will contribute to help define optimal storage conditions useful to produce highly valuable and high-quality products.


Asunto(s)
Cannabinoides , Cannabis , Cromatografía de Gases y Espectrometría de Masas , Microextracción en Fase Sólida , Compuestos Orgánicos Volátiles , Cannabis/química , Cannabinoides/análisis , Cromatografía de Gases y Espectrometría de Masas/métodos , Microextracción en Fase Sólida/métodos , Compuestos Orgánicos Volátiles/análisis , Cromatografía Líquida de Alta Presión/métodos , Inflorescencia/química , Liofilización/métodos , Desecación/métodos
4.
Anal Bioanal Chem ; 416(10): 2553-2564, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38459965

RESUMEN

Crocin-I, a valuable natural compound found in saffron (Crocus sativus L.), is the most abundant among the various crocin structures. Developing a cost-effective and scalable purification process to produce high-purity crocin-I is of great interest for future investigations into its biological properties and its potential applications in the treatment of neurological disorders. However purifying crocin-I through single-column preparative chromatography (batch) poses a yield-purity trade-off due to structural similarities among crocins, meaning that the choice of the collection window sacrifices either yield in benefit of higher purity or vice versa. This study demonstrates how the continuous countercurrent operating mode resolves this dilemma. Herein, a twin-column MCSGP (multicolumn countercurrent solvent gradient purification) process was employed to purify crocin-I. This study involved an environmentally friendly ethanolic extraction of saffron stigma, followed by an investigation into the stability of the crocin-I within the feed under varying storage conditions to ensure a stable feed composition during the purification. Then, the batch purification process was initially designed, optimized, and subsequently followed by the scale-up to the MCSGP process. To ensure a fair comparison, both processes were evaluated under similar conditions (e.g., similar total column volume). The results showed that, at a purity grade of 99.7%, the MCSGP technique demonstrated significant results, namely + 334% increase in recovery + 307% increase in productivity, and - 92% reduction in solvent consumption. To make the purification process even greener, the only organic solvent employed was ethanol, without the addition of any additive. In conclusion, this study presents the MCSGP as a reliable, simple, and economical technique for purifying crocin-I from saffron extract, demonstrating for the first time that it can be effectively applied as a powerful approach for process intensification in the purification of natural products from complex matrices.


Asunto(s)
Distribución en Contracorriente , Crocus , Distribución en Contracorriente/métodos , Solventes/química , Carotenoides/química , Etanol/química
5.
Anal Bioanal Chem ; 416(8): 1809-1820, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38358532

RESUMEN

The existence of slow adsorption-desorption kinetics in chiral liquid chromatography is common knowledge. This may significantly contribute to worsening the efficiency and kinetic performance of a chromatographic run, especially when high flow rates are employed. Many attempts and protocols have been proposed to access this term, the so-called c ads , but they are based on different (theoretical) assumptions. As a consequence, no official method is available for the estimation of the adsorption-desorption kinetics term. In this work, a novel approach to access c ads is presented. This procedure combines experimental results obtained with kinetic and thermodynamic measurements. The investigations have been performed on two zwitterionic teicoplanin chiral stationary phases (CSPs) based on 1.9 µ m fully porous and 2.0 µ m superficially porous particles (FPPs and SPPs), using Z-D,L-Methionine as probe molecule. Kinetic studies have been performed through the combination of both stop-flow and dynamic measurements, while adsorption isotherms have been calculated through Inverse Method. This study has confirmed that, on both particle formats, analyte diffusion on the surface of the particle is negligible, meaning that adsorption is localized, and it has been demonstrated that adsorption-desorption kinetics is strongly dependent on particle geometry and, in particular, on the loading of chiral selector. These findings are fundamental not only to unravel novel aspects of the complex enantiorecognition mechanism but also to optimize the employment of CSPs for ultra-fast and preparative applications.

6.
J Chromatogr A ; 1713: 464530, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38035518

RESUMEN

Preparative liquid chromatography in reversed phase conditions (RPLC) is the most common approach adopted in the downstream processing for the purification of therapeutic peptides at industrial level. Due to the strict requirements on the quality imposed by the Regulatory Agencies, routinary methods based on the use of aqueous buffers and acetonitrile (ACN) as organic modifier are commonly used, where ACN is practically the only available choice for the purification of peptide derivatives. However, ACN is known to suffers of many shortcomings, such as drastic shortage in the market, high costs and, most importantly, it shows unwanted toxicity for human health and environment, which led it among the less environmentally friendly ones. For this reason, the selection of a suitable alternative becomes crucial for the sustainable downstream processing of peptides and biopharmaceuticals in general. In this paper, a promising green solvent, namely dimethyl carbonate (DMC) has been used for the separation of a peptide not only in linear conditions but also for its purification through non-linear overloaded chromatography. The performance of the process has been compared to that achievable with the common method where ACN is used as organic modifier and to that obtained with two additional solvents (namely ethanol and isopropanol), already used as greener alternatives to ACN. This proof-of-concept study showed that, thanks to its higher elution strength, DMC can be considered a green alternative to ACN, since it allows to reduce method duration while reaching good purities and recoveries. Indeed, at a target purity fixed to 98.5 %, DMC led to the best productivity with respect to all the other solvents tested, confirming its suitability as a sustainable alternative to ACN for the purification of complex biopharmaceutical products.


Asunto(s)
Cromatografía de Fase Inversa , Péptidos , Humanos , Cromatografía de Fase Inversa/métodos , Solventes/química , Acetonitrilos/química , Cromatografía Líquida de Alta Presión/métodos
7.
J Chromatogr A ; 1712: 464477, 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-37944433

RESUMEN

Nowadays, environmental problems are drawing the attention of governments and international organisations, which are therefore encouraging the transition to green industrial processes and approaches. In this context, chemists can help indicate a suitable direction. Beside the efforts focused on greening synthetic approaches, currently also analytical techniques and separations are under observation, especially those employing large volumes of organic solvents, such as reversed-phase liquid chromatography (RPLC). Acetonitrile has always been considered the best performing organic modifier for RPLC applications, due to its chemical features (complete miscibility in water, UV transparency, low viscosity etc); nevertheless, it suffers of severe shortcomings, and most importantly, it does not fully comply with Environmental, Health and Safety (EHS) requirements. For these reasons, alternative greener solvents are being investigated, especially easily available alcohols. In this work, chromatographic performance of the most common solvents used in reversed-phase chromatography, i.e., acetonitrile, ethanol and isopropanol, have been compared to a scarcely used solvent, dimethyl carbonate (DMC). The analytes of interest were two small molecules, caffeine and paracetamol, whose kinetics and retention behaviour obtained with the four solvents have been compared, and all contributions to band broadening have been assessed. Results about kinetic performance are very promising, indicating that a small amount (7 % v/v) of DMC is able to produce the same efficiency as a 2.5-times larger ACN volume (18 % v/v), and larger efficiency than alcohols. This paper reports, for the first time, fundamental studies concerning the mass transfer phenomena when DMC is used as an organic solvent in RPLC, and, together with the companion paper, represents the results of a research whose final aim was to discover whether DMC is suitable for chromatographic applications both in linear and preparative conditions.


Asunto(s)
Cromatografía de Fase Inversa , Etanol , Cromatografía de Fase Inversa/métodos , Solventes/química , Etanol/química , Acetonitrilos/química , Cromatografía Líquida de Alta Presión/métodos
8.
Anal Chem ; 95(25): 9630-9637, 2023 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-37294639

RESUMEN

The retention behavior of small molecules and N-protected amino acids on a zwitterionic teicoplanin chiral stationary phase (CSP), prepared on superficially porous particles (SPPs) of 2.0 µm particle diameter, has shown that efficiency and enantioselectivity, and so enantioresolution, dramatically change depending on the employed organic modifier. In particular, it was found that while methanol permits the boost of enantioselectivity and resolution of the amino acids, at the cost of efficiency, acetonitrile allows for the ability to reach extraordinary efficiency even at high flow rates (with reduced plate height <2 and up to 300,000 plates/m at the optimum flow rate). To understand these features, an approach based on the investigation of mass transfer through the CSP, the estimation of the binding constants of amino acids on the CSP, and the assessment of compositional properties of the interfacial region between bulk mobile phase and solid surface has been adopted.

9.
J Chromatogr A ; 1676: 463190, 2022 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-35704958

RESUMEN

A novel zwitterionic-teicoplanin chiral stationary phase (CSP), based on superficially porous particles (SPPs) of 2.7 µm particle diameter and 160 Å pore size, has been prepared and evaluated towards the enantioseparation of important classes of compounds, including chiral drugs, pesticides, and N-derivatized amino acids. The comparison with two analogous CSPs prepared on SPPs with 2.7 and 2.0 µm particle diameter and 90 Å pore size has revealed that the use of large-pore particles allows to dramatically improve both the enantioselectivity and the resolution-per-analysis-time, at the point that the column prepared with the new CSP outperformed the one packed with the finest particles. On the novel wide-pore CSP, the separation of fifteen racemates of pratical importance was significantly improved in terms of both enantioselectivity and resolution-per-analysis time-compared to the CSPs based on SPPs with smaller pores (90 Å). Such a CSP would be suitable for very fast enantioseparations allowing the saving of solvent for greener high-efficiency/high-throughput applications.


Asunto(s)
Aminoácidos , Teicoplanina , Cromatografía Líquida de Alta Presión , Porosidad , Solventes , Estereoisomerismo , Teicoplanina/química
10.
J Chromatogr A ; 1672: 463076, 2022 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-35468565

RESUMEN

The growing popularity of cannabis products and recent legalization of cannabis for recreational purposes have contributed to the increase of the demand for analytical methods able to give a detailed characterization of cannabis samples and derivatives. In this context, one of the aspects that is strongly emerging is about the hazardous potential of uncharacterised minor cannabinoids, including chiral ones, for which achiral potency testing methods currently employed do not give any information. For this reason, there is a growing interest towards the development of liquid chromatographic methods for the enantioseparation of cannabinoids. Much work is needed in this field where one of the major limitations is the lack of optically pure standards. This manuscript reports about the chromatographic behavior of five popular cannabinoids (including the cannabichromene racemate, CBC) on nine immobilised polysaccharide-based chiral stationary phases (CSPs) differently substituted, under reversed phase conditions. Results showed that chemo-selectivity of CSPs is not affected by changes in mobile phase composition, in the range of mobile phase investigated. In addition, the presence of electron withdrawing groups on the CSPs systematically leads to shorter retention times compared to when electron donating groups are present. An application of separation of cannabinoids from a real hemp extract on two of the chiral columns employed in this work revealed the presence of both CBC enantiomers in the sample.


Asunto(s)
Cannabinoides , Cannabis , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida/métodos , Cromatografía de Fase Inversa/métodos , Polisacáridos/química , Estereoisomerismo
11.
Anal Bioanal Chem ; 414(18): 5385-5395, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35146546

RESUMEN

This work reports about a screening of four adsorbents with different polarity employed for the separation of the main phytocannabinoids contained in Cannabis sativa L., under normal phase liquid chromatography (NPLC). The effect of polarity and type of interaction mechanisms of the adsorbents (namely Si-, CN-, Diol-, and NH2-based SPs) on retention has been investigated under a variety of conditions either by using different combinations of apolar solvents (heptane or hexane) and alcohols (ethanol or isopropanol). The columns have also been employed for the separation of a real cannabis sample. Graphical Abstract Investigating the effect of polarity of stationary and mobile phases on retention of cannabinoids in normal phase liquid chromatography.


Asunto(s)
Cannabinoides , Cannabis , Alcoholes , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida/métodos , Solventes/química
12.
Phytochem Anal ; 33(4): 507-516, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35064611

RESUMEN

INTRODUCTION: Blueberries are known for their very high content of biologically active phenolic compounds; nonetheless, differently from the North American and European species of blueberries, Neotropical blueberries have not been extensively studied yet. OBJECTIVES: In the present paper, the phenolic composition of Vaccinium floribundum Kunth, which is endemic to the Andean regions and grows 1,600 to 4,500 meters above sea level, was investigated by ultra-high-performance liquid chromatography coupled to high-resolution mass spectrometry (UHPLC-HRMS). Native and fermented berries were compared in terms of phenolic composition as well as antioxidant activity, total phenolic content, and total anthocyanin content. MATERIALS AND METHODS: V. floribundum native and fermented berries were extracted and analyzed by UHPLC-HRMS. The acquired datasets were processed by Compound Discoverer 3.1 using a dedicated data analysis workflow that was specifically set up for phenolic compound identification. RESULTS: In total, 309 compounds were tentatively identified, including anthocyanins, flavonoids, phenolic acids, and proanthocyanidins. The molecular transformations of phenolic compounds during fermentation were comprehensively investigated for the first time, and by a customized data processing workflow, 13 quinones and quinone methides were tentatively identified in the fermented samples. Compared to other species of the genus Vaccinium, a peculiar phenolic profile is observed, with low abundance of highly methylated compounds. CONCLUSION: Andean berries are a rich source of a wide variety of phenolic compounds. Untargeted MS analyses coupled to a dedicated data processing workflow allowed expanding the current knowledge on these berries, improving our understanding of the fate of phenolic compounds after fermentation.


Asunto(s)
Vaccinium , Antocianinas/análisis , Antioxidantes/análisis , Cromatografía Líquida de Alta Presión , Biología Computacional , Frutas/química , Espectrometría de Masas , Fenoles/análisis , Extractos Vegetales/química , Vaccinium/química
13.
J Chromatogr A ; 1655: 462492, 2021 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-34507140

RESUMEN

This review is a collection of recent applications of mass spectrometry studies for the characterization of phytocannabinoids in cannabis and hemp plant material and related products. The focus is mostly on recent applications using mass spectrometry as detector, in hyphenation to typical separation techniques (i.e., liquid chromatography or gas chromatography), but also with less common couplings or by simple direct analysis. The papers are described starting from the most common approach for targeted quantitative analysis, with applications using low-resolution mass spectrometry equipment, but also with the introduction of high-resolution mass analyzers as the detectors. This reflects a common trend in this field, and introduces the most recent applications using high-resolution mass spectrometry for untargeted analysis. The different approaches used for untargeted analysis are then described, from simple retrospective analysis of compounds without pure standards, through untargeted metabolomics strategies, and suspect screening methods, which are the ones currently allowing to achieve the most detailed qualitative characterization of the entire phytocannabinoid composition, including minor compounds which are usually overlooked in targeted studies and in potency evaluation. These approaches also represent powerful strategies to answer questions on biological and pharmacological activity of cannabis, and provide a sound technology for improved classification of cannabis varieties. Finally, open challenges are discussed for future directions in the detailed study of complex phytocannabinoid mixtures.


Asunto(s)
Cannabinoides , Cannabis , Cannabinoides/análisis , Cromatografía de Gases y Espectrometría de Masas , Espectrometría de Masas , Estudios Retrospectivos
14.
Molecules ; 26(15)2021 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-34361839

RESUMEN

The market of biomolecules with therapeutic scopes, including peptides, is continuously expanding. The interest towards this class of pharmaceuticals is stimulated by the broad range of bioactivities that peptides can trigger in the human body. The main production methods to obtain peptides are enzymatic hydrolysis, microbial fermentation, recombinant approach and, especially, chemical synthesis. None of these methods, however, produce exclusively the target product. Other species represent impurities that, for safety and pharmaceutical quality reasons, must be removed. The remarkable production volumes of peptide mixtures have generated a strong interest towards the purification procedures, particularly due to their relevant impact on the manufacturing costs. The purification method of choice is mainly preparative liquid chromatography, because of its flexibility, which allows one to choose case-by-case the experimental conditions that most suitably fit that particular purification problem. Different modes of chromatography that can cover almost every separation case are reviewed in this article. Additionally, an outlook to a very recent continuous chromatographic process (namely Multicolumn Countercurrent Solvent Gradient Purification, MCSGP) and future perspectives regarding purification strategies will be considered at the end of this review.


Asunto(s)
Péptidos/química , Péptidos/síntesis química , Péptidos/aislamiento & purificación , Cromatografía Liquida , Humanos , Péptidos/uso terapéutico
15.
J Chromatogr A ; 1651: 462304, 2021 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-34118531

RESUMEN

Hemp and cannabis industry is undergoing a renewed interest due to legalization of marijuana (a topic that all countries are discussing, especially in recent years) and the growing importance of therapeutic properties of cannabinoids. Together with an increment in the production of hemp and recreational cannabis, there has been an increasing demand for accurate potency testing of products (i.e. quantification of main cannabinoids present in the plant in terms of weight percentage) prior commercialization. This translates in an urgent need of reliable analytical methods to characterize cannabis and hemp samples. Cannabis and hemp preparations are commercialized under various forms (e.g., flowers, oils, candies or even baked goods) usually containing a large number of often very similar compounds making their separation very challenging. Strictly connected to this, another emerging topic concerns the need for the developing of large scale separation techniques for the purification of cannabinoids from complex matrices and for the preparation of analytical-grade standards (including the chiral ones). This paper reviews the most recent achievements in both these aspects. Cutting-edge applications and novel opportunities in potency testing by high performance liquid chromatography (HPLC) with UV detection (which is becoming the golden standard, according to several pharmacopeias, for this kind of measurements) are discussed. The focus has been given to the very important topic of enantio-discrimination of chiral cannabinoids, for which supercritical fluid chromatography (SFC) appears to be particularly suitable. The last part of the work covers the purification of cannabinoids through preparative chromatography. In this regard, particular attention has been given to the most innovative multi-column techniques allowing for the continuous purification of target molecules. The most recent advancements and future challenges in this field are discussed.


Asunto(s)
Cannabinoides/análisis , Técnicas de Química Analítica/métodos , Cromatografía Líquida de Alta Presión , Cromatografía con Fluido Supercrítico , Cannabis/química , Técnicas de Química Analítica/instrumentación , Flores/química , Extractos Vegetales/química
16.
J Chromatogr A ; 1637: 461854, 2021 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-33387912

RESUMEN

In this work, a detailed study of mass transfer properties of trans-stilbene oxide (TSO) enantiomers on two Whelk-O1 chiral stationary phases (CSPs) has been performed. The CSPs were prepared by using both fully-porous silica particles of 2.5 µm particle diameter and superficially-porous ones of 2.6 µm particle diameter as base materials. By combining stop-flow and dynamic measurements in normal-phase conditions, the different contributions to mass transfer have been estimated. The study of intraparticle diffusion has revealed that the adsorption of both enantiomers is localized (i.e., characterized by absence of surface diffusion). The determination of thermodynamic binding constants (measured through adsorption isotherms) supports this finding.


Asunto(s)
Estilbenos/química , Adsorción , Difusión , Cinética , Porosidad , Dióxido de Silicio/química , Estereoisomerismo , Temperatura
17.
Trends Analyt Chem ; 132: 116051, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32994652

RESUMEN

Single-column (batch) preparative chromatography is the technique of choice for purification of biotherapeutics but it is often characterized by an intrinsic limitation in terms of yield-purity trade-off, especially for separations containing a larger number of product-related impurities. This drawback can be alleviated by employing multicolumn continuous chromatography. Among the different methods working in continuous mode, in this paper we will focus in particular on Multicolumn Countercurrent Solvent Gradient Purification (MCSGP) which has been specifically designed for challenging separations of target biomolecules from their product-related impurities. The improvements come from the automatic internal recycling of the impure fractions inside the chromatographic system, which results in an increased yield without compromising the purity of the pool. In this article, steps of the manufacturing process of biopharmaceuticals will be described, as well as the advantages of continuous chromatography over batch processes, by particularly focusing on MCSGP.

18.
J Chromatogr A ; 1630: 461532, 2020 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-32950816

RESUMEN

An unusual convex-upward van Deemter curve was observed for the more retained enantiomer of a chiral sulfoxide (2-(benzylsulfinyl)benzamide) on a cellulose tris(4-chloro-3-methylphenylcarbamate)-based chiral stationary phase (CSP), prepared on silica particles of 1000 Å pore size. In contrast, the firstly eluted enantiomer of the same molecule exhibited the traditional convex-downward van Deemter curve. A detailed kinetic and thermodynamic investigation has revealed that this unusual phenomenon, which however has already been observed in chiral chromatography, originates when the adsorption of the compound is very strong and the solid-phase diffusion negligible. Experimentally, the intraparticle diffusion of the more retained enantiomer of the sulfoxide was found to be one order of magnitude smaller than that of the first eluted one. Overall, this translates into very little longitudinal diffusion (b-term of van Deemter curve) accompanied by high solid-liquid mass transfer resistance (c-term). Finally the comparison with another, differently-substituted chiral sulfoxide (whose enantiomers both exhibit traditional van Deemter curve behavior) has allowed to correlate these findings to the specific characteristics of the molecule.

19.
J Chromatogr A ; 1625: 461304, 2020 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-32709347

RESUMEN

A twin-column Multicolumn Countercurrent Solvent Gradient Purification (MCSGP) process has been developed for the purification of a therapeutic peptide, glucagon, from a crude synthetic mixture. This semi-continuous process uses two identical columns operating either in interconnected or in batch mode, thus enabling the internal recycle of the portions of the eluting stream which do not comply with purity specifications. Because of this feature, which actually results in the simulated countercurrent movement of the stationary phase with respect to the mobile one, the yield-purity trade-off typical of traditional batch preparative chromatography can be alleviated. Moreover, the purification process can be completely automatized. Aim of this work is to present a simple procedure for the development of the MCSGP process based on a single batch experiment, in the case of a therapeutic peptide of industrial relevance. This allowed to recover roughly 90% of the injected glucagon in a purified pool with a purity of about 90%. A comparison between the performance of the MCSGP process and the classical single column batch process indicates that percentage increase in the recovery of target product is +23% when transferring the method from batch conditions to MCSGP, with an unchanged purity of around 89%. This improvement comes at the expenses of a reduction of about 38% in productivity.


Asunto(s)
Distribución en Contracorriente/métodos , Péptidos/aislamiento & purificación , Solventes/química , Cromatografía Líquida de Alta Presión , Glucagón/aislamiento & purificación , Factores de Tiempo
20.
J Chromatogr A ; 1624: 461235, 2020 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-32540075

RESUMEN

In this study, 31 racemates of Nα-FMOC (fluorenylmethoxycarbonyl) amino acids (AAs) with different chemico-physical characteristics (neutral nonpolar, neutral polar, acidic and basic) have been successfully resolved in fast enantioselective chromatography on recently-developed zwitterionic-teicoplanin chiral stationary phases (CSPs). The CSPs were prepared by covalently bonding the teicoplanin selector on fully-porous particles of narrow dispersion particle-size distribution (particle diameter 1.9 µm) and superficially-porous particles (2.0 µm). Both the zwitterionic-teicoplanin CSPs have proved to be ideal media for the separation of this important class of compounds. In particular, the zwitterionic CSP prepared on superficially-porous particles exhibited superior enantioselectivity and resolution, compared to that made of fully porous particles, in virtue of more favorable thermodynamics. The zwitterionic nature of these CSPs allowed avoiding the annoying effect of Donnan's exclusion of enantiomers from the stationary phase. This effect, on the opposite, was frequently observed on a commercial teicoplanin CSP (Teicoshell) employed for comparative purposes. Noticeably, on the zwitterionic-teicoplanin CSPs, by using either acetonitrile- or methanol-rich mobile phases (MPs), it was possible to favor speed over enantioresolution and vice versa. This work gives further replies to the request for rapid determination of enantiomeric excess of Nα-FMOC proteinogenic (and non-proteinogenic) AAs, typically used as preferred chiral synthons in the solid-phase synthesis of therapeutic peptides.


Asunto(s)
Aminoácidos/aislamiento & purificación , Cromatografía/métodos , Fluorenos/aislamiento & purificación , Proteínas/química , Teicoplanina/química , Porosidad , Estereoisomerismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...