RESUMEN
This paper reports a pathological comparison between the synovium of the shoulder with rotator cuff tears (RCTs) with or without an allograft in the same patient and assesses allograft remodeling after superior capsular reconstruction (SCR). A 49-year-old man underwent SCR with a fascia lata allograft for irreparable RCTs. Two years postoperatively, the patient underwent arthroscopic rotator cuff repair for left RCTs and arthroscopic debridement to alleviate right shoulder pain. Additionally, revascularization was confirmed in the allograft of the fascia lata. In conclusion, allografts are considered highly safe and expected to be engrafted after SCR.
RESUMEN
Background: We assessed damaged anterior capsulolabral motion during axial shoulder rotation in patients with anterior shoulder instability. Methods: Twenty-nine shoulders of 28 patients with anterior shoulder instability who underwent cine-magnetic resonance imaging during axial rotation of the adducted arm were included. The motion was captured after an intra-articular injection of saline solution (10-20 mL). During imaging, the shoulder was rotated passively from maximum internal rotation to maximum external rotation in the first 10 s and then back to maximum internal rotation in the subsequent 10 s. We assessed the rotational angles of the damaged labrum during compressing and pulling the humeral head against the glenoid. Evaluation of the rotational angles was performed on a series of axial images through the humeral head center. Results: The mean angles that damaged labrum compressed and pulled off against the glenoid were 12.0 ± 19.1° and 2.8 ± 21.2°, respectively. Additionally, seven of the 29 shoulders showed that the damaged labrum compressed on the glenoid rim before the rotational angle exceeded 0° during external rotation. In 13 shoulders, the damaged labrum could remain repositioned on the glenoid rim over the neutral position during internal rotation. In two shoulders, the damaged labrum was not compressed against the glenoid at the maximum external rotation. The injected saline moved from the posterior to the anterior side of the glenohumeral joint during internal rotation in each shoulder. Conclusion: The damaged labrum could be positioned on the glenoid when the arm was in a traditional internal immobilization.
RESUMEN
Background There has been no report comparing shoulder kinematics and muscle activities during axial shoulder rotation in different positions. The purpose of this study was to investigate differences in shoulder kinematics and muscle activities during axial shoulder rotation in healthy subjects between standing and supine positions using three-dimensional/two-dimensional (3D/2D) registration techniques and electromyography (EMG). Methods Eleven healthy males agreed to participate in this study. We recorded the fluoroscopy time during active shoulder axial rotation with a 90° elbow flexion in both standing and supine positions, simultaneously recording surface EMG of the infraspinatus, anterior deltoid, posterior deltoid, and biceps brachii. Three-dimensional bone models were created from CT images, and shoulder kinematics were analyzed using 3D/2D registration techniques. Muscle activities were evaluated as a ratio of mean electromyographic values to 5-sec maximum voluntary isometric contractions. Results Scapular kinematics during axial shoulder rotation in the supine position showed similar patterns with those in the standing position. The scapula was more posteriorly tilted and more downwardly rotated in the supine posture than in standing (P < 0.001 for both). Acromiohumeral distance (AHD) in the supine posture was significantly larger than in standing. Muscle activities showed no significant differences between postures except for biceps (P < 0.001). Discussion Shoulder kinematics and muscle activities during axial rotation were similar in pattern between standing and supine postures, but there were shifts in scapular pose and AHD. The findings of this study suggest that posture may be an important consideration for the prescription of optimal shoulder therapy following surgery or for the treatment of shoulder disorders.
RESUMEN
OBJECTIVES: Inflammatory mediators play important roles in the pain associated with rotator cuff tears (RCTs), but their underlying mechanisms are unclear. Apelin, a neuropeptide, is upregulated under inflammatory conditions and possibly contributes to pain induced by rotator cuff tears. This translational study aimed to examine apelin expression and regulation by tumor necrosis factor alpha (TNF-α) in patients with RCT and in rat RCT models. METHODS: Synovial tissues were harvested from the glenohumeral joints of the shoulders in 46 patients who underwent arthroscopic Bankart repair for recurrent shoulder dislocations (RSDs) or arthroscopic rotator cuff repair for RCTs. The harvested tissues were extracted and processed by reverse transcriptase-polymerase chain reaction (RT-PCR). Rats underwent sham or RCT surgery; the rotator cuff tissues were extracted 1, 7, 14, 28, and 56 days after surgery and analyzed for mRNA expression levels of the TNF-α and apelin using RT-PCR. The cultured rotator cuff cells (RCCs) were stimulated with TNF-α to examine their role in the regulation of apelin expression. RESULTS: Apelin expression was higher in the RCT group than in the RSD group and significantly correlated with pain intensity. In rats, the expression was also higher in RCT. Apelin expression significantly increased during the acute and chronic phases in rats. CONCLUSIONS: In cultured RCCs, apelin mRNA levels significantly increased after TNF-α stimulation. Apelin levels were regulated by TNF-α and were highly expressed in patients with RCT and rats in RCT models. Thus, apelin may be a new pain management target for RCTs.
RESUMEN
Ankle joint instability after acute lateral ankle sprain (LAS) is an important factor for deciding treatment strategies. Nevertheless, the degree of ankle joint mechanical instability as a criterion for making clinical decisions is unclear. This study examined the reliability and validity of an Automated Length Measurement System (ALMS) in ultrasonography for assessing real-time anterior talofibular distance. Using a phantom model, we tested whether ALMS could detect two points within a landmark following movement of the ultrasonographic probe. Furthermore, we examined whether ALMS was comparable with the manual measurement method for 21 patients with an acute LAS (42 ankles) during the reverse anterior drawer test. Using the phantom model, ALMS measurements showed excellent reliability, with errors below 0.4 mm and with a small variance. The ALMS measurement was comparable to manually measured values (ICC = 0.53-0.71, p < 0.001) and detected differences in talofibular joint distances between unaffected and affected ankles of 1.41 mm (p < 0.001). ALMS shortened the measurement time by one-thirteenth for one sample compared to the manual measurement (p < 0.001). ALMS could be used to standardize and simplify ultrasonographic measurement methods for dynamic joint movements without human error in clinical applications.
Asunto(s)
Traumatismos del Tobillo , Inestabilidad de la Articulación , Ligamentos Laterales del Tobillo , Humanos , Articulación del Tobillo , Reproducibilidad de los Resultados , Tobillo , Inestabilidad de la Articulación/diagnósticoRESUMEN
Hypothesis and/or Background: Increased flexor digitorum superficialis (FDS) tendon activity can be a therapeutic target for elbow disorders in adolescent baseball players. The proportion of adolescent baseball players who can use FDS independently is unknown, and which finger is most often used remains unclear. This study investigated whether adolescent baseball players intentionally used FDS on each finger. Methods: Adolescent baseball players were recruited and assessed for FDS function for each finger using the standard technique. Results: Sixty-nine participants (mean age: 10.4 years) were recruited. Participants numbered 33, 56, 59, and 25 on the throwing side and those numbered 28, 46, 54, and 33 on the nonthrowing side could independently flex the proximal interphalangeal joint while holding their palms in the index, middle, ring, and small fingers, respectively. When assessing both throwing and nonthrowing participants, a significant number of participants could independently flex the proximal interphalangeals of the ring and middle fingers but had difficulty with the index and small fingers (P < .001). No significant difference was noted between the throwing and nonthrowing participants in any finger (P > .05). Discussion and/or Conclusion: One study reported that participating baseball players with elbow pain have more medial elbow joint space than those without pain symptoms. In another study on finger movements during pitching motion, the force of the thumb, index, middle, and ring fingers was greatest immediately before maximum external rotation. According to both reports, FDS function, especially in the index finger, can be a therapeutic target for medial-sided elbow injuries in adolescent baseball players.
RESUMEN
Objective: Approximately two-thirds of patients with history of shoulder dislocation may develop osteoarthritis (OA) of the glenohumeral joint. However, the biochemical mechanisms underlying the association between dislocation and OA are largely unknown. This study aimed to investigate macrophage markers and inflammatory cytokine expression associated with shoulder instability (SI) in comparison to rotator cuff tears (RCTs). Design: This study included 30 patients with SI and 30 patients with RCTs. Synovial membrane samples were harvested from the rotator interval during the arthroscopic anatomical repair for both groups. The localization of tumor necrosis factor-α (TNF-α), interleukin (IL)-1ß, and cluster of differentiation (CD) 68 in synovial membranes was determined by immunohistochemistry. Transcript-level expressions of the inflammatory cytokines (TNFA and IL1B) and macrophage markers pan-CD68 and -M1 (CD80 and CD86) were quantified. CD80 and CD86 expression in macrophages from the SI group was confirmed using flow cytometry. Results: TNF-α, IL-1ß, and CD68 were expressed in the synovial lining layer of the synovial tissue in both groups. In addition, the mRNA expressions of TNFA, IL1B, CD68, and CD80 were significantly higher in the SI group compared to the RCT group (P â= â0.012, 0.014, 0.022, 0.003, respectively). In samples from the SI group, 96.3% of CD68+/CD14+ macrophages were CD86-positive, whereas 2.5% of CD68+/CD14+/CD86+ cells were CD80-positive. Conclusions: Patients with SI had higher mRNA levels of TNFA, IL1B, CD68, and CD80 than those with RCTs. These findings may partially explain the biochemical mechanism underlying the frequent development and progression of osteoarthritis in patients with SI.
RESUMEN
Hypothesis: We hypothesized that the treatment of recalcitrant lateral epicondylitis requires accurate identification of the painful area to promote remodeling of the degenerated extensor insertion and to stabilize the tendon origin during tendon healing. Thus, we performed tenodesis with bone marrow venting under local anesthesia for recalcitrant lateral epicondylitis. Methods: Twenty patients (21 elbows) were treated with bone marrow venting at the painful area of the lateral epicondyle of the elbow and tenodesis using 2 soft anchors lateral to the capitellum (immediately distal to the painful area) and were followed up for ≥2 years. Patients were assessed using the numerical rating scale for pain and the Quick Disabilities of the Arm, Shoulder, and Hand questionnaire, and objective evaluation included active range of motion. Results: The mean preoperative and postoperative pain scores were 7.5 and 0.5, respectively, indicating significant pain relief (P < .001). The mean preoperative and postoperative Quick Disabilities of the Arm, Shoulder, and Hand questionnaire scores were 44.2 and 1.0, respectively (P < .001). Two elbows had a slightly positive Thomsen test at the final visit. No recurrence of intra-articular symptoms induced by synovial fringe impingement was observed. Patients experienced more pain at the bone-tendon junction of extensors than at the tendon parenchyma. Conclusion: Tenodesis with bone marrow venting under local anesthesia was effective for subjective patient satisfaction and positive clinical outcomes at ≥2 years of follow-up in patients with recalcitrant lateral epicondylitis. Intra-articular symptoms can be improved by stabilization of the lateral soft tissue without treatment for intra-articular lesions.
RESUMEN
BACKGROUND: Epidemiological studies have reported a positive association between hypercholesterolemia and shoulder disease. Previous studies have focused on the effect of hypercholesterolemia on tendinopathy. Moreover, hypercholesterolemia has also been linked to joint pathology in the knee and hand. However, the effect of hyperlipidemia on glenohumeral joint remain unclear. A hypercholesterolemic condition has been reported to alter levels of A Disintegrin and Metalloprotease with Thrombospondin Motifs (ADAMTSs) and matrix metalloproteases (MMPs) in synovium of the knee joint. Here, we evaluated the mRNA expression of ADAMTSs and MMPs in the glenohumeral synovium of patients with and without hypercholesterolemia. METHODS: Study participants were 73 patients who underwent arthroscopic rotator cuff repair for degenerative rotator cuff tears. They were divided into two groups according to total cholesterol (TC) and triglyceride levels. Synovial membrane samples were harvested at the rotator interval during surgery, and mRNA expression levels of the aggrecanases ADAM-TS4 and ADAM-TS5 and MMPs (MMP-1, 3, 9, and 13) were analyzed quantitatively. RESULTS: ADAM-TS5 and MMP1 mRNA levels were significantly higher in the high TC group than in the low TC group (P = 0.023 and P = 0.025, respectively). In contrast, no significant differences were observed in ADAMTS4 or MMPs 3, 9, and 13 (ADAMTS4, P = 0.547; MMP3, P = 0.55; MMP9, P = 0.521; and MMP13, P = 0.785). CONCLUSION: Hypercholesterolemia may alter MMP1 and ADAMTS5 expression in the synovium of the glenohumeral joint.
Asunto(s)
Proteína ADAMTS5/genética , Hipercolesterolemia/genética , Metaloproteinasa 1 de la Matriz/genética , Líquido Sinovial/metabolismo , Proteína ADAMTS5/metabolismo , Adulto , Anciano , Femenino , Humanos , Hipercolesterolemia/metabolismo , Masculino , Metaloproteinasa 1 de la Matriz/metabolismo , Persona de Mediana Edad , ARN Mensajero , Lesiones del Manguito de los Rotadores/metabolismo , Lesiones del Manguito de los Rotadores/cirugíaRESUMEN
ABSTRACT: Whether femoral varus derotational osteotomy (VDRO) alone or a combination of femoral and pelvic osteotomies should be performed for hip dislocation in nonambulatory children with cerebral palsy (CP) remains controversial. Few studies have reported radiographical results after the surgical treatment in nonambulatory children with CP. This study aimed to assess the results and determine predictors indicating progressive hip subluxation and redislocation after VDRO without pelvic osteotomy. We retrospectively analyzed 22 hips in 15 nonambulatory children with CP. All patients underwent VDRO without pelvic osteotomy and were followed up for at least 5âyears. The mean follow-up period was 7.3â±â1.9âyears. In radiological assessments, we investigated migration percentage (MP), center-edge angle, neck-shaft angle, teardrop distance, break in Shenton's line (SL), sharp's angle, acetabular ridge angle (ARA), and the change ratio of MP (Change MP). We classified patients with an MP of <40% at final follow-up in the Good group and those with an MP of ≥40% in the Poor group. The Good group included 10 children (14 hips), and the Poor group included 8 children (8 hips). No preoperative differences were found in the means of all the radiographical parameters. However, MP was significantly different between the groups from 1âyear postoperatively. ARA showed improvement 5âyears after surgery in the Good group. Change MP in the Good group was maintained from immediately after surgery to the final follow-up. Multivariate logistic regression analyses revealed that preoperative break in SL and Change MP immediately after surgery were parameters to predict MP at the final follow-up. In the receiver operating characteristic analysis, the cut-off values were estimated to be 19.2âmm for preoperative SL and 79.0% for Change MP immediately after surgery. Within 7.3âyears of follow-up, 63.6% of the patients who underwent VDRO without pelvic osteotomy had good results. Preoperative SL and postoperative Change MP can be considered as predictors of postoperative subluxation and/or dislocation.
Asunto(s)
Parálisis Cerebral/complicaciones , Luxación de la Cadera/cirugía , Luxaciones Articulares , Osteotomía/métodos , Niño , Femenino , Estudios de Seguimiento , Luxación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: Medial elbow apophysitis is a traction apophysitis observed in the medial epicondyle of the elbow in preadolescent baseball players. The purpose of this study was to determine the relationship between medial elbow apophysitis and elbow valgus instability in preadolescent baseball players. METHODS: The participants were classified into a control group and an injury group; the injury group included participants diagnosed with a medial elbow injury (inclusion criteria were only symptoms of the elbow joint or positive findings on physical examinations, or both). Elbow valgus instability was assessed by measuring the differences in ulnohumeral joint gapping width, with and without gravity stress induced by weight loading of the forearm using ultrasonography. RESULTS: The control and injury groups consisted of 81 and 23 preadolescent baseball players, respectively. In the throwing elbow, valgus instability in the injury group was significantly greater than that in the control group (1.07 vs. 0.57 mm, P = .001). In the non-throwing elbow, valgus instability in the injury group was significantly greater than that in the control group (0.57 vs. 0.37 mm, P = .011). The area under the curve for valgus instability of the throwing elbow was 0.89 mm (95% confidence interval, 0.64-0.77), and the cut-off value for elbow pain appearance was 0.80 mm. CONCLUSION: The increased elbow valgus instability in the injury group was associated with a medial elbow injury. For the elbow valgus instability of the non-throwing side in the injury group, we considered that players with medial elbow apophysitis inherently have elbow laxity.
RESUMEN
BACKGROUND: The rotator cuff undergoes natural degeneration with age, leading to age-related rotator cuff tear; however, the precise mechanism remains unclear. Transforming growth factor-beta (TGF-ß) concentrations rise with age and TGF-ß contributes to the pathophysiology of skeletal muscle. TGF-ß has also been shown to suppress expression of the myokine, apelin, in skin fibroblasts. We hypothesized that TGF-ß expression in the rotator cuff changes with age and regulates apelin expression, thereby contributing to rotator cuff degeneration. METHODS: We used quantitative reverse-transcription polymerase chain reaction (Q-RT-PCR) to measure the expression of apelin and tendon-related genes (Tnmd, Col1a1, and Col3a1) in the rotator cuff of young (12 weeks), adult (24 weeks), and old (48 weeks) rats. Using Q-RT-PCR and enzyme-linked immunosorbent assay, we also measured Tgfb mRNA and TGF-ß protein levels, respectively. Furthermore, we used Q-RT-PCR to measure apelin mRNA levels in rotator cuff-derived cells after treatment with 0 (control) and 10 ng/mL recombinant TGF-ß. RESULTS: Apelin mRNA levels were significantly lower in old compared to young and adult rats. Similarly, tendon-related genes, Tnmd, Col1a1, and Col3a1, were significantly lower in adult and old rats than young rats. In contrast, Tgfb mRNA and TGF-ß protein were significantly higher in old compared to young rats. Stimulation with exogenous TGF-ß significantly decreased Apelin mRNA expression compared to control. CONCLUSIONS: TGF-ß regulates apelin expression in the rotator cuff and may play a key role in the degenerative pathology of the rotator cuff with age.
Asunto(s)
Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Animales , Apelina , ARN Mensajero/genética , Ratas , Lesiones del Manguito de los Rotadores/genética , Factor de Crecimiento Transformador beta , Factores de Crecimiento TransformadoresRESUMEN
BACKGROUND: Subacromial impingement syndrome is a common disorder associated with functional impairment and disability of the shoulder. Internal/external glenohumeral rotation is important for shoulder function. However, because it is difficult to measure the glenohumeral joint rotation angle physically, the relationship between this angle and the clinical symptoms of subacromial impingement syndrome is still largely unknown. Using advanced cine-magnetic resonance imaging techniques, we designed a study to improve our understanding of the nature of this relationship. METHODS: We evaluated 100 shoulders with subacromial impingement syndrome. Patients underwent cine-magnetic resonance imaging during axial rotation with the arm adducted. During imaging, patients rotated their shoulder from maximum internal rotation to maximum external rotation over 10 seconds and then to maximum internal rotation over 10 seconds. The rotation angles were then evaluated using a series of axial images. The Constant-Murley (Constant) and UCLA scores for each patient were determined, and the correlation between the scores and rotational angles was assessed. Patients were divided into 3 groups according to the Constant pain score, and the rotational angles of each group were compared. Rotational angles were also compared between shoulders with and without night pain. RESULTS: The external rotation angle showed a significant but low correlation with the Constant and UCLA scores (ρ = 0.24 and 0.24, respectively), whereas the internal rotation angle did not. In comparing the pain groups of Constant score and UCLA score, the external rotation angle significantly decreased as pain increased (P < .01), demonstrating a negative correlation (ρ = -0.47, -0.41, respectively). Additionally, the shoulders of patients with night pain showed significantly more restriction of external rotation angles than the shoulders of those without night pain (P = .01). CONCLUSIONS: Limitation of the glenohumeral joint's external rotation is correlated with pain, for which we explore possible explanations. The results suggest that night pain can be effectively reduced using therapeutic interventions that target external rotational dysfunction.
RESUMEN
[Purpose] We followed-up patients who underwent arthroscopic rotator cuff repair (ARCR) for 2â years to assess the prognosis of rotator cuff tears and compared the outcomes of the patients with and without re-rupture. We also examined the usefulness of Shoulder36, a self-assessment tool, for assessing the long-term prognosis in patients undergoing ARCR. [Participants and Methods] We included 28 patients who received occupational therapy pre- and post-ARCR between April 2012 and August 2015 and categorized them based on the occurrence of re-rupture. We followed-up on their prognoses for 2â years using physical examination and Shoulder36 assessment. [Results] Re-rupture occurred in five patients within 3 months of treatment. During the 2â year follow-up, the control group showed a significant improvement in pain and bi-directional active range of motion during physical assessment and in five out of six domains during Shoulder36 assessment. In contrast, the re-rupture group showed significant differences for only three domains of the Shoulder36 assessment twelve months after surgery. [Conclusion] We confirmed the long-term functional improvement and maintenance in the re-rupture group, suggesting that continued rehabilitation, compensatory movements, and detailed guidance on daily life activities are required for patients after ARCR. Furthermore, Shoulder36 can be useful for assessing the prognosis of patients with and without re-rupture.
RESUMEN
BACKGROUND: Rotator cuff tears (RCTs) are often associated with severe shoulder pain. Non-steroidal anti-inflammatory drugs, not recommended for long-term use, do not effectively manage RCT-induced pain, resulting in reduced quality of life. To improve management, a better understanding of the fundamental properties of RCT pain is needed. Here, we aimed to compare the expression levels of nerve growth factor (NGF) and cyclooxygenase-2 (COX-2) mRNA in the synovial tissues of patients with RCT-induced pain and patients with non-painful recurrent shoulder dislocation (RSD). METHODS: The study included 32 patients with RCT who underwent arthroscopic rotator cuff repair and 28 patients with non-painful RSD who underwent arthroscopic Bankart repair. Synovial tissue samples were harvested from subacromial bursa and rotator interval of RCT patients and from the rotator interval of RSD patients. Samples were analyzed quantitatively expression levels for NGF and COX2 mRNA and NGF protein. RESULTS: NGF mRNA and protein levels were significantly higher in the rotator interval of RCT patients than in the rotator interval of RSD patients (p = 0.0017, p = 0.012, respectively), while COX2 mRNA levels did not differ significantly between the two patient groups. In RCT patients, COX2 mRNA was more highly expressed in the rotator interval than in the subacromial bursa (p = 0.038), whereas the mRNA and protein levels of NGF did not differ between the two tissues. The expression of NGF mRNA in the synovium of the rotator interval was significantly correlated with the numeric rating scale of pain (ρ = 0.38, p = 0.004). CONCLUSION: NGF mRNA and protein levels were elevated in patients with painful RCT compared with those in patients with non-painful RSD, whereas COX-2 levels were comparable in the two patient groups. These findings provide insights into novel potential strategies for clinical management of RCT.
Asunto(s)
Lesiones del Manguito de los Rotadores , Artroscopía , Humanos , Factor de Crecimiento Nervioso/genética , Manguito de los Rotadores , Membrana SinovialRESUMEN
BACKGROUND: One of the mechanisms of the efficacy of extracorporeal shock wave therapy (ESWT) for impaired muscle coordination of limbs is the destruction of Acetylcholine receptors (AChRs) at neuromuscular junction. The highly increased density of AChRs can change the acoustic impedance, and this change of the acoustic impedance can be the reason that radial shock wave (rESW) destroy AChRs selectively. However, the relationship between applied energy of rESWs and the therapeutic efficacy remains unclear, although some studies compared the clinical efficacy of rESWT between high- and low-energy applications. This study aimed to compare the CMAP change among different energy and pulses of rESW application. METHODS: Male Sprauger-Dawley rats were used. A device that generates radial shock waves pneumatically, was used to apply the following six patterns of radial extracorporeal shockwaves in different energy flux densities and pulses to the right calf of each rat: 1, 8000 pulses at 0.045 mJ/mm2; 2, 4000 pulses at 0.09 mJ/mm2; 3, 2000 pulses at 0.18 mJ/mm2; 4, 4000 pulses at 0.045 mJ/mm2; 5, 2000 pulses at 0.09 mJ/mm2; 6, 1000 pulses at 0.18 mJ/mm2. Left calf muscles were considered controls. RESULTS: There was a significant reduction in CMAP amplitude between control and rESW-exposed muscles in the group applied 4000 pulses with EFD at 0.09 mJ/mm2 and the group applied 2000 pulses with EFD at 0.18 mJ/mm2. However, the group applied 8000 pulses with EFD at 0.045 mJ/mm2 and all groups which was exposed to total 180 mJ rESW application did not show a significantly decreased CMAP amplitude compared with the untreated side. CONCLUSIONS: Total energy and energy flux density correlate with a decrease in CMAP amplitude by rESW application. These findings could be availed by clinicians in actual clinical setting for the proper application of rESW.
Asunto(s)
Tratamiento con Ondas de Choque Extracorpóreas , Ondas de Choque de Alta Energía , Animales , Masculino , Músculo Esquelético , Ratas , Resultado del TratamientoRESUMEN
BACKGROUND: Discrepancies exist between the magnitude of musculoskeletal problems and the competency of physicians practicing musculoskeletal medicine, which likely stems from medical school-level educational deficiencies. Therefore, inadequate orthopedic surgery education during medical school may affect the number of students aspiring to practice orthopedic surgery. However, the motivating factors underlying medical students' selection of a career specialty are largely unknown. This study aims to use a survey to examine the motivations of medical students who consider orthopedic surgery as a potential career specialty. METHODS: A questionnaire survey was administered to medical students in our medical faculty. The results were stratified on the basis of gender, year, and experience as a patient; results were then compared between students who wished to practice orthopedic surgery and those who did not consider it a potential specialty. RESULTS: Of the 499 students who responded to the questionnaire, 47% considered orthopedic surgery as their career specialty. Being male and having experienced orthopedic surgery as a patient were significant factors influencing the aspiration to practice orthopedic surgery (p < 0.001). In addition, the motivation for choosing orthopedic surgery was academic interest for 55% of students. In the first and fifth years, more than half of the students preferred an orthopedic surgery specialty. The percentage of fifth-year students who were candidates for orthopedic surgery as their career specialty significantly exceeded that of students in other years (p = 0.03). However, the percentage of students considering orthopedic surgery decreased in the sixth year. CONCLUSION: Our findings suggest that orthopedic surgeons should provide a clearer, more informative job description to attract female medical students' attention and change their negative perception of orthopedic surgery. Furthermore, including education that incorporates experiences closer to clinical practice at the medical-school level is important for increasing the number of candidates for orthopedics.
Asunto(s)
Procedimientos Ortopédicos , Ortopedia , Selección de Profesión , Estudios Transversales , Docentes Médicos , Femenino , Humanos , MasculinoRESUMEN
Tissue flossing aims to improve range of motion (ROM), reduce pain, and enhance injury prevention. However, evidence is lacking regarding its effects. Therefore, this study examined the effects of flossing on hamstring muscles function in comparison to dynamic stretching (DS). Seventeen healthy young men ([mean ± SD] age, 23.2 ± 1.1 years; height, 1.72 ± 0.08 m; body mass, 63.5 ± 9.3 kg) volunteered as subjects in this randomized crossover trial. The subjects received flossing, DS, and control interventions in random order at least 1 week apart to eliminate the influence of the previous intervention. Flossing involved passive twisting and active movement using a floss band (Sanctband COMPRE Floss Blueberry, Sanct Japan Co., Ltd.). DS was performed for 4 minutes in 30-second sets consisting of 15 repetitions of 2 seconds stretching. The following were measured before and after each intervention: straight leg raise (SLR) test, passive knee extension (KE) test, passive torque, passive stiffness, fascicle length in the biceps femoris long head as an indication of hamstring muscles flexibility, and maximal isometric knee flexion contraction, maximal eccentric knee extension/flexion contraction, rate of force development, and muscle activity. Flossing yielded significant improvements in the SLR test (mean difference in post-intervention changes between interventions: 5.4°, percentage change from pre- to post-value: 13.4%, p = 0.004), passive KE test (6.2°, 4.5%, p < 0.001), passive torque at end-ROM (3.8 Nm, 4.7%, p = 0.03), and maximal eccentric knee flexion contraction (14.9% body weight, 8.2%, p = 0.03) than control. Moreover, flossing yielded 2.1-fold greater improvements in the passive KE test (3.8°, 4.5%, p = 0.03) and yielded significant improvements in the maximal eccentric knee extension contraction (29.9% body weight, 13.8%, p = 0.02) than DS. Therefore, flossing on hamstring muscles is more beneficial than DS with respect to increasing ROM and muscle exertion.
Asunto(s)
Músculos Isquiosurales/fisiología , Ejercicios de Estiramiento Muscular , Modalidades de Fisioterapia/instrumentación , Adulto , Estudios Cruzados , Humanos , Articulación de la Rodilla/fisiología , Masculino , Contracción Muscular , Rango del Movimiento Articular , Torque , Adulto JovenRESUMEN
Although osteochondroma is a benign bone tumor often observed in daily practice, solitary osteochondroma of the bicipital tuberosity is rarely observed. Herein, we report a case of bilateral solitary osteochondroma of the bicipital tuberosity. A 76-year-old woman experienced crackling and painful clicking bilaterally in her proximal forearms during pronation-supination. X-ray imaging, computed tomography, and magnetic resonance imaging revealed that the symptom was caused by bilateral solitary osteochondroma of the bicipital tuberosity. Bone tumor resection was performed on both sides. After surgery, the symptoms improved. X-ray imaging performed 2 years after surgery revealed no tumor recurrence. When painful clicking occurs around the elbow joint, a solitary osteochondroma of the bicipital tuberosity should be suspected; this symptom should be examined, and the surgeon should consider surgery positively. Exposed subchondral bone may rub against, collide with, or impinge upon the ulna during forearm pronation-supination and induce pain.
Asunto(s)
Neoplasias Óseas/diagnóstico por imagen , Osteocondroma/diagnóstico por imagen , Cúbito , Anciano , Neoplasias Óseas/complicaciones , Neoplasias Óseas/cirugía , Articulación del Codo , Femenino , Humanos , Imagen por Resonancia Magnética , Osteocondroma/complicaciones , Osteocondroma/cirugía , Dolor/diagnóstico por imagen , Dolor/etiología , Pronación , Radiografía , Supinación , Tomografía Computarizada por Rayos XRESUMEN
BACKGROUND: Various arthroscopic tenodesis techniques for the treatment of long head of the biceps tendon pathologic abnormalities have been described. PURPOSE: This study evaluated the clinical outcomes of using a bioabsorbable interference screw and soft anchor for long head of the biceps tendon arthroscopic tenodesis. METHODS: Sixty patients treated by this technique between February 2013 and March 2015 were followed up for at least 2 years. In our operative technique, after the bone hole was made just proximal to the pectoralis major, the soft anchor was inserted at the bottom of the hole. After tenotomy of the long head of the biceps tendon proximal to the bone hole, the tendon was fixed into the bottom of the hole temporarily using the soft anchor. Finally, the tendon was fixed in the hole with a bioabsorbable interference screw. RESULTS: The UCLA score 15.1 points preoperatively and 32.4 points at follow-up (p < 0.05). The Constant 55.8 points preoperatively and 93.9 points at follow-up (p < 0.01). After biceps tenodesis, no cosmetic deformities were found in 56 patients (93.3%), and four patients (6.7%) had a Popeye deformity. On postoperative magnetic resonance evaluation, the long head of the biceps tendon was located on the bicipital groove without deviation in 53 cases (88.3%), on the bicipital groove with a partial deviation in 6 cases (10.0%), and outside the bicipital groove with complete deviation (dislocated) in 1 case (1.7%). CONCLUSION: We found that arthroscopic biceps tenodesis using a soft anchor provided a reliable means for treating biceps pathology with no cosmetic deformities and with good clinical results.