Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Nat Commun ; 15(1): 1722, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38409240

RESUMEN

Crimean-Congo hemorrhagic fever virus (CCHFV) is a WHO priority pathogen. Antibody-based medical countermeasures offer an important strategy to mitigate severe disease caused by CCHFV. Most efforts have focused on targeting the viral glycoproteins. However, glycoproteins are poorly conserved among viral strains. The CCHFV nucleocapsid protein (NP) is highly conserved between CCHFV strains. Here, we investigate the protective efficacy of a CCHFV monoclonal antibody targeting the NP. We find that an anti-NP monoclonal antibody (mAb-9D5) protected female mice against lethal CCHFV infection or resulted in a significant delay in mean time-to-death in mice that succumbed to disease compared to isotype control animals. Antibody protection is independent of Fc-receptor functionality and complement activity. The antibody bound NP from several CCHFV strains and exhibited robust cross-protection against the heterologous CCHFV strain Afg09-2990. Our work demonstrates that the NP is a viable target for antibody-based therapeutics, providing another direction for developing immunotherapeutics against CCHFV.


Asunto(s)
Virus de la Fiebre Hemorrágica de Crimea-Congo , Fiebre Hemorrágica de Crimea , Femenino , Animales , Ratones , Virus de la Fiebre Hemorrágica de Crimea-Congo/metabolismo , Proteínas de la Nucleocápside/metabolismo , Anticuerpos Monoclonales , Fiebre Hemorrágica de Crimea/prevención & control , Glicoproteínas/metabolismo , Anticuerpos Antivirales
2.
AJPM Focus ; 2(4): 100141, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37885754

RESUMEN

Introduction: Reported confirmed cases represent a small portion of overall true cases for many infectious diseases. The undercounting of true cases can be considerable when a significant portion of infected individuals are asymptomatic or minimally symptomatic, as is the case with COVID-19. Seroprevalence studies are an efficient way to assess the extent to which true cases are undercounted during a large-scale outbreak and can inform efforts to improve case identification and reporting. Methods: A longitudinal seroprevalence study of active duty U.S. military members was conducted from May 2020 through June 2021. A random selection of service member serum samples submitted to the Department of Defense Serum Repository was analyzed for the presence of antibodies reactive to SARS-CoV-2. The monthly seroprevalence rates were compared with those of cumulative confirmed cases reported during the study period. Results: Seroprevalence was 2.3% in May 2020 and increased to 74.0% by June 2021. The estimated true case count based on seroprevalence was 9.3 times greater than monthly reported cases at the beginning of the study period and fell to 1.7 by the end of the study. Conclusions: In our sample, confirmed case counts significantly underestimated true cases of COVID-19. The increased availability of testing over the study period and enhanced efforts to detect asymptomatic and minimally symptomatic cases likely contributed to the fall in the seroprevalence to reported case ratio.

3.
Microorganisms ; 9(3)2021 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-33806942

RESUMEN

Ebola virus is a continuing threat to human populations, causing a virulent hemorrhagic fever disease characterized by dysregulation of both the innate and adaptive host immune responses. Severe cases are distinguished by an early, elevated pro-inflammatory response followed by a pronounced lymphopenia with B and T cells unable to mount an effective anti-viral response. The precise mechanisms underlying the dysregulation of the host immune system are poorly understood. In recent years, focus on host-derived miRNAs showed these molecules to play an important role in the host gene regulation arsenal. Here, we describe an investigation of RNA biomarkers in the fatal Ebola virus disease (EVD) cynomolgus macaque model. We monitored both host mRNA and miRNA responses in whole blood longitudinally over the disease course in these non-human primates (NHPs). Analysis of the interactions between these classes of RNAs revealed several miRNA markers significantly correlated with downregulation of genes; specifically, the analysis revealed those involved in dysregulated immune pathways associated with EVD. In particular, we noted strong interactions between the miRNAs hsa-miR-122-5p and hsa-miR-125b-5p with immunological genes regulating both B and T-cell activation. This promising set of biomarkers will be useful in future studies of severe EVD pathogenesis in both NHPs and humans and may serve as potential prognostic targets.

4.
Appl Biosaf ; 25(2): 74-82, 2020 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-36035081

RESUMEN

Introduction: Inactivation of biological agents and particularly select agents has come under increased scrutiny since the US Army inadvertently shipped live anthrax both inside and outside the US, leading to more stringent regulations regarding inactivation. Methods: Formalin and Trizol® LS were used to inactivate virus samples in complex matrices. Cytotoxic chemicals were removed using either desalting or concentrating columns or through dilution using HYPERFlasks. Efficacy of inactivation was evaluated either through plaque assay or immunofluorescence assay. Results: All virus samples and tissue specimens were successfully inactivated using either formalin or Trizol® LS. Both the desalting columns and concentrating columns were able to remove cytotoxic chemicals to facilitate viral amplification in controls. Dilution of cytotoxic chemicals through HYPERFlasks was also successful provided that media was changed completely within 48 hours of first cell passage. Discussion: All inactivation testing demonstrates that both formalin and Trizol® LS successfully inactivate virus-infected cell lines and tissues, which is consistent with previously published literature. Each sample cleanup method has its benefits and pitfalls. Desalting columns can process the largest sample size but are also susceptible to plugging and degradation, whereas concentrating columns are not as vulnerable but can only process 5% of the sample load per run. Conclusion: Based on our results along with those of our colleagues, it is recommended that the regulatory authorities re-evaluate the requirements for each entity to validate well-established inactivation methods in house because there would be limited benefits despite the considerable resources required for this effort.

5.
Sci Adv ; 5(7): eaaw9535, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31309159

RESUMEN

Crimean-Congo hemorrhagic fever virus (CCHFV) is an important human pathogen. Limited evidence suggests that antibodies can protect humans against lethal CCHFV disease but the protective efficacy of antibodies has never been evaluated in adult animal models. Here, we used adult mice to investigate the protection provided against CCHFV infection by glycoprotein-targeting neutralizing and non-neutralizing monoclonal antibodies (mAbs). We identified a single non-neutralizing antibody (mAb-13G8) that protected adult type I interferon-deficient mice >90% when treatment was initiated before virus exposure and >60% when administered after virus exposure. Neutralizing antibodies known to protect neonatal mice from lethal CCHFV infection failed to confer protection regardless of immunoglobulin G subclass. The target of mAb-13G8 was identified as GP38, one of multiple proteolytically cleaved glycoproteins derived from the CCHFV glycoprotein precursor polyprotein. This study reveals GP38 as an important antibody target for limiting CCHFV pathogenesis and lays the foundation to develop immunotherapeutics against CCHFV in humans.


Asunto(s)
Anticuerpos Monoclonales de Origen Murino , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Virus de la Fiebre Hemorrágica de Crimea-Congo/inmunología , Fiebre Hemorrágica de Crimea , Proteínas Virales/inmunología , Animales , Anticuerpos Monoclonales de Origen Murino/inmunología , Anticuerpos Monoclonales de Origen Murino/farmacología , Anticuerpos Neutralizantes/inmunología , Anticuerpos Neutralizantes/farmacología , Anticuerpos Antivirales/inmunología , Anticuerpos Antivirales/farmacología , Fiebre Hemorrágica de Crimea/inmunología , Fiebre Hemorrágica de Crimea/prevención & control , Ratones , Ratones Noqueados
6.
Emerg Infect Dis ; 24(12): 2202-2209, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30457521

RESUMEN

During 2013-2014, we collected 1,926 serum samples from humans and 4,583 ticks (Hyalomma asiaticum or Dermacentor nuttalli) in select regions of Mongolia to determine the risk for Crimean-Congo hemorrhagic fever virus (CCHFV) infection among humans in this country. Testing of human serum samples by ELISA demonstrated an overall CCHFV antibody prevalence of 1.4%; Bayankhongor Province had the highest prevalence, 2.63%. We pooled and analyzed tick specimens by real-time reverse transcription PCR; 1 CCHFV-positive H. asiaticum tick pool from Ömnögovi was identified. In phylogenetic analyses, the virus's partial small segment clustered with CCHFV isolates from Central Asia, and the complete medium segment grouped with CCHFV isolates from Africa, Asia, and the Middle East. This study confirms CCHFV endemicity in Mongolia and provides information on risk for CCHFV infection. Further research is needed to better define the risk for CCHFV disease to improve risk mitigation, diagnostics, and surveillance.


Asunto(s)
Virus de la Fiebre Hemorrágica de Crimea-Congo/clasificación , Fiebre Hemorrágica de Crimea/epidemiología , Fiebre Hemorrágica de Crimea/virología , Animales , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/inmunología , Biología Computacional , Geografía Médica , Virus de la Fiebre Hemorrágica de Crimea-Congo/genética , Virus de la Fiebre Hemorrágica de Crimea-Congo/aislamiento & purificación , Fiebre Hemorrágica de Crimea/historia , Fiebre Hemorrágica de Crimea/transmisión , Historia del Siglo XXI , Humanos , Inmunoglobulina G/inmunología , Mongolia/epidemiología , Pruebas de Neutralización , Filogenia , ARN Viral , Análisis de Secuencia de ADN , Pruebas Serológicas , Garrapatas/virología
7.
Am J Trop Med Hyg ; 98(1): 211-215, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29165231

RESUMEN

Crimean-Congo hemorrhagic fever virus (CCHFV) is a tick-borne virus of the genus Nairovirus within the family Bunyaviridae. Infection can result in general myalgia, fever, and headache with some patients developing hemorrhagic fever with mortality rates ranging from 5% to 30%. CCHFV has a wide geographic range that includes Africa, Asia, the Middle East, and Europe with nucleotide sequence variation approaching 20% across the three negative-sense RNA genome segments. While phylogenetic clustering generally aligns with geographic origin of individual strains, distribution can be wide due to tick/CCHFV dispersion via migrating birds. This sequence diversity negatively impacts existing molecular diagnostic assays, leading to false negative diagnostic results. Here, we updated a previously developed CCHFV real-time reverse transcription polymerase chain reaction (RT-PCR) assay to include strains not detected using that original assay. Deep sequencing of eight different CCHFV strains, including three that were not detectable using the original assay, identified sequence variants within this assay target region. New primers and probe based on the sequencing results and newly deposited sequences in GenBank greatly improved assay sensitivity and inclusivity with the exception of the genetically diverse strain AP92. For example, we observed a four log improvement in IbAr10200 detection with a new limit of detection of 256 PFU/mL. Subsequent comparison of this assay to another commonly used CCHFV real-time RT-PCR assay targeting a different region of the viral genome showed improved detection, and both assays could be used to mitigate CCHFV diversity for diagnostics. Overall, this work demonstrated the importance of continued viral sequencing efforts for robust diagnostic assay development.


Asunto(s)
Virus de la Fiebre Hemorrágica de Crimea-Congo/genética , Fiebre Hemorrágica de Crimea/diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , ADN Viral/genética , Fiebre Hemorrágica de Crimea/virología , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos
8.
J Vis Exp ; (125)2017 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-28745647

RESUMEN

Transmission electron microscopy (TEM) is used to observe the ultrastructure of viruses and other microbial pathogens with nanometer resolution. Most biological materials do not contain dense elements capable of scattering electrons to create an image; therefore, a negative stain, which places dense heavy metal salts around the sample, is required. In order to visualize viruses in suspension under the TEM they must be applied to small grids coated with a transparent surface only nanometers thick. Due to their small size and fragility, these grids are difficult to handle and easily moved by air currents. The thin surface is easily damaged, leaving the sample difficult or impossible to image. Infectious viruses must be handled in a biosafety cabinet (BSC) and some require a biocontainment laboratory environment. Staining viruses in biosafety levels (BSL)-3 and -4 is especially challenging because these environments are more turbulent and technicians are required to wear personal protective equipment (PPE), which decreases dexterity. In this study, we evaluated a new device to assist in negative staining viruses in biocontainment. The device is a capsule that works as a specialized pipette tip. Once grids are loaded into the capsule, the user simply aspirates reagents into the capsule to deliver the virus and stains to the encapsulated grid, thus eliminating user handling of grids. Although this technique was designed specifically for use in BSL-3 or -4 biocontainment, it can ease sample preparation in any lab environment by enabling easy negative staining of virus. This same method can also be applied to prepare negative stained TEM specimens of nanoparticles, macromolecules and similar specimens.


Asunto(s)
Cápsulas/uso terapéutico , Microscopía Electrónica de Transmisión/métodos , Coloración Negativa/métodos , Manejo de Especímenes
9.
J Virol Methods ; 242: 9-13, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28012899

RESUMEN

Viral preparations are essential components in diagnostic research and development. The production of large quantities of virus traditionally is done by infecting numerous tissue culture flasks or roller bottles, which require large incubators and/or roller bottle racks. The Corning HYPERFlask® is a multilayer flask that uses a gas permeable film to provide gas exchange between the cells and culture medium and the atmospheric environment. This study evaluated the suitability of the HYPERFlask for production of Lassa, Ebola, Bundibugyo, Reston, and Marburg viruses and compared it to more traditional methods using tissue culture flasks and roller bottles. The HYPERFlask produced cultures were equivalent in virus titer and indistinguishable in immunodiagnostic assays. The use of the Corning HYPERFlask for viral production is a viable alternative to traditional tissue culture flasks and roller bottles. HYPERFlasks allow for large volumes of virus to be produced in a small space without specialized equipment.


Asunto(s)
Ebolavirus/crecimiento & desarrollo , Virus Lassa/crecimiento & desarrollo , Marburgvirus/crecimiento & desarrollo , Cultivo de Virus/instrumentación , Replicación Viral , Animales , Chlorocebus aethiops , Medios de Cultivo , Ebolavirus/aislamiento & purificación , Virus Lassa/aislamiento & purificación , Marburgvirus/aislamiento & purificación , Células Vero , Cultivo de Virus/métodos
10.
J Virol Methods ; 238: 70-76, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27751950

RESUMEN

Transmission electron microscopy can be used to observe the ultrastructure of viruses and other microbial pathogens with nanometer resolution. In a transmission electron microscope (TEM), the image is created by passing an electron beam through a specimen with contrast generated by electron scattering from dense elements in the specimen. Viruses do not normally contain dense elements, so a negative stain that places dense heavy metal salts around the sample is added to create a dark border. To prepare a virus sample for a negative stain transmission electron microscopy, a virus suspension is applied to a TEM grid specimen support, which is a 3mm diameter fragile specimen screen coated with a few nanometers of plastic film. Then, deionized (dI) water rinses and a negative stain solution are applied to the grid. All infectious viruses must be handled in a biosafety cabinet (BSC) and many require a biocontainment laboratory environment. Staining viruses in biosafety levels (BSL) 3 and 4 is especially challenging because the support grids are small, fragile, and easily moved by air currents. In this study we evaluated a new device for negative staining viruses called mPrep/g capsule. It is a capsule that holds up to two TEM grids during all processing steps and for storage after staining is complete. This study reports that the mPrep/g capsule method is valid and effective to negative stain virus specimens, especially in high containment laboratory environments.


Asunto(s)
Contención de Riesgos Biológicos , Microscopía Electrónica de Transmisión/métodos , Coloración Negativa/métodos , Manejo de Especímenes/métodos , Virus/ultraestructura , Virus Chikungunya/ultraestructura , Contención de Riesgos Biológicos/métodos , Ebolavirus/ultraestructura , Microscopía Electrónica de Transmisión/instrumentación , Microscopía Electrónica de Transmisión/normas , Virus/aislamiento & purificación
11.
Viruses ; 7(3): 857-72, 2015 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-25710889

RESUMEN

Development and evaluation of medical countermeasures for diagnostics, vaccines, and therapeutics requires production of standardized, reproducible, and well characterized virus preparations. For filoviruses this includes plaque assay for quantitation of infectious virus, transmission electron microscopy (TEM) for morphology and quantitation of virus particles, and real-time reverse transcription PCR for quantitation of viral RNA (qRT-PCR). The ViroCyt® Virus Counter (VC) 2100 (ViroCyt, Boulder, CO, USA) is a flow-based instrument capable of quantifying virus particles in solution. Using a proprietary combination of fluorescent dyes that stain both nucleic acid and protein in a single 30 min step, rapid, reproducible, and cost-effective quantification of filovirus particles was demonstrated. Using a seed stock of Ebola virus variant Kikwit, the linear range of the instrument was determined to be 2.8E+06 to 1.0E+09 virus particles per mL with coefficient of variation ranging from 9.4% to 31.5% for samples tested in triplicate. VC particle counts for various filovirus stocks were within one log of TEM particle counts. A linear relationship was established between the plaque assay, qRT-PCR, and the VC. VC results significantly correlated with both plaque assay and qRT-PCR. These results demonstrated that the VC is an easy, fast, and consistent method to quantify filoviruses in stock preparations.


Asunto(s)
Ebolavirus/aislamiento & purificación , Carga Viral/métodos , Animales , Humanos , Coloración y Etiquetado/métodos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...