Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Bioelectron Med ; 9(1): 16, 2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37464423

RESUMEN

BACKGROUND: Autonomic nerve stimulation is used as a treatment for a growing number of diseases. We have previously demonstrated that application of efferent vagus nerve stimulation (eVNS) has promising glucose lowering effects in a rat model of type 2 diabetes. This paradigm combines high frequency pulsatile stimulation to block nerve activation in the afferent direction with low frequency stimulation to activate the efferent nerve section. In this study we explored the effects of the parameters for nerve blocking on the ability to inhibit nerve activation in the afferent direction. The overarching aim is to establish a blocking stimulation strategy that could be applied using commercially available implantable pulse generators used in the clinic. METHODS: Male rats (n = 20) had the anterior abdominal vagus nerve implanted with a multi-electrode cuff. Evoked compound action potentials (ECAP) were recorded at the proximal end of the electrode cuff. The efficacy of high frequency stimulation to block the afferent ECAP was assessed by changes in the threshold and saturation level of the response. Blocking frequency and duty cycle of the blocking pulses were varied while maintaining a constant 4 mA current amplitude. RESULTS: During application of blocking at lower frequencies (≤ 4 kHz), the ECAP threshold increased (ANOVA, p < 0.001) and saturation level decreased (p < 0.001). Application of higher duty cycles (> 70%) led to an increase in evoked neural response threshold (p < 0.001) and a decrease in saturation level (p < 0.001). During the application of a constant pulse width and frequency (1 or 1.6 kHz, > 70% duty cycle), the charge delivered per pulse had a significant influence on the magnitude of the block (ANOVA, p = 0.003), and was focal (< 2 mm range). CONCLUSIONS: This study has determined the range of frequencies, duty cycles and currents of high frequency stimulation that generate an efficacious, focal axonal block of a predominantly C-fiber tract. These findings could have potential application for the treatment of type 2 diabetes.

2.
Physiol Rep ; 10(8): e15257, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35439355

RESUMEN

Vagus nerve stimulation is emerging as a promising treatment for type 2 diabetes. Here, we evaluated the ability of stimulation of the vagus nerve to reduce glycemia in awake, freely moving metabolically compromised rats. A model of type 2 diabetes (n = 10) was induced using a high-fat diet and low doses of streptozotocin. Stimulation of the abdominal vagus nerve was achieved by pairing 15 Hz pulses on a distal pair of electrodes with high-frequency blocking stimulation (26 kHz, 4 mA) on a proximal pair of electrodes to preferentially produce efferent conducting activity (eVNS). Stimulation was well tolerated in awake, freely moving rats. During 1 h of eVNS, glycemia decreased in 90% of subjects (-1.25 ± 1.25 mM h, p = 0.017), and 2 dB above neural threshold was established as the most effective "dose" of eVNS (p = 0.009). Following 5 weeks of implantation, eVNS was still effective, resulting in significantly decreased glycemia (-1.7 ± 0.6 mM h, p = 0.003) during 1 h of eVNS. There were no overt changes in fascicle area or signs of histopathological damage observed in implanted vagal nerve tissue following chronic implantation and stimulation. Demonstration of the biocompatibility and safety of eVNS in awake, metabolically compromised animals is a critical first step to establishing this therapy for clinical use. With further development, eVNS could be a promising novel therapy for treating type 2 diabetes.


Asunto(s)
Diabetes Mellitus Tipo 2 , Estimulación del Nervio Vago , Animales , Glucemia , Diabetes Mellitus Tipo 2/terapia , Frecuencia Cardíaca , Humanos , Ratas , Nervio Vago/fisiología , Estimulación del Nervio Vago/métodos
3.
Front Neurosci ; 15: 761525, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34803592

RESUMEN

Active implantable neurological devices like deep brain stimulators have been used over the past few decades to treat movement disorders such as those in people with Parkinson's disease and more recently, in psychiatric conditions like obsessive compulsive disorder. Electrode-tissue interfaces that support safe and effective targeting of specific brain regions are critical to success of these devices. Development of directional electrodes that activate smaller volumes of brain tissue requires electrodes to operate safely with higher charge densities. Coatings such as conductive hydrogels (CHs) provide lower impedances and higher charge injection limits (CILs) than standard platinum electrodes and support safer application of smaller electrode sizes. The aim of this study was to examine the chronic in vivo performance of a new low swelling CH coating that supports higher safe charge densities than traditional platinum electrodes. A range of hydrogel blends were engineered and their swelling and electrical performance compared. Electrochemical performance and stability of high and low swelling formulations were compared during insertion into a model brain in vitro and the formulation with lower swelling characteristics was chosen for the in vivo study. CH-coated or uncoated Pt electrode arrays were implanted into the brains of 14 rats, and their electrochemical performance was tested weekly for 8 weeks. Tissue response and neural survival was assessed histologically following electrode array removal. CH coating resulted in significantly lower voltage transient impedance, higher CIL, lower electrochemical impedance spectroscopy, and higher charge storage capacity compared to uncoated Pt electrodes in vivo, and this advantage was maintained over the 8-week implantation. There was no significant difference in evoked potential thresholds, signal-to-noise ratio, tissue response or neural survival between CH-coated and uncoated Pt groups. The significant electrochemical advantage and stability of CH coating in the brain supports the suitability of this coating technology for future development of smaller, higher fidelity electrode arrays with higher charge density requirement.

4.
J Neural Eng ; 17(4): 045014, 2020 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-32659750

RESUMEN

OBJECTIVE: Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing Nitrogen incorporated ultrananocrystalline (N-UNCD) diamond electrodes. APPROACH: A prototype implant containing up to twenty-five 120 × 120 µm N-UNCD electrodes was implanted into 16 anaesthetised cats and attached to the retina either using a single tack or via magnetic coupling with a suprachoroidally placed magnet. Multiunit responses to retinal stimulation using charge-balanced biphasic current pulses were recorded acutely in the visual cortex using a multichannel planar array. Several stimulus parameters were varied including; the stimulating electrode, stimulus polarity, phase duration, return configuration and the number of electrodes stimulated simultaneously. MAIN RESULTS: The rigid nature of the device and its form factor necessitated complex surgical procedures. Surgeries were considered successful in 10/16 animals and cortical responses to single electrode stimulation obtained in eight animals. Clinical imaging and histological outcomes showed severe retinal trauma caused by the device in situ in many instances. Cortical measures were found to significantly depend on the surgical outcomes of individual experiments, phase duration, return configuration and the number of electrodes stimulated simultaneously, but not stimulus polarity. Cortical thresholds were also found to increase over time within an experiment. SIGNIFICANCE: The study successfully demonstrated that an epiretinal prosthesis containing diamond electrodes could produce cortical activity with high precision, albeit only in a small number of cases. Both surgical approaches were highly challenging in terms of reliable and consistent attachment to and stabilisation against the retina, and often resulted in severe retinal trauma. There are key challenges (device form factor and attachment technique) to be resolved for such a device to progress towards clinical application, as current surgical techniques are unable to address these issues.


Asunto(s)
Diamante , Prótesis Visuales , Animales , Gatos , Estimulación Eléctrica , Electrodos , Electrodos Implantados , Estudios de Factibilidad , Retina
5.
Physiol Rep ; 8(11): e14479, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32512650

RESUMEN

Despite advancements in pharmacotherapies, glycemia is poorly controlled in type 2 diabetic patients. As the vagus nerve regulates energy metabolism, here we evaluated the effect various electrical vagus nerve stimulation strategies have on glycemia and glucose-regulating hormones, as a first step to developing a novel therapy of type 2 diabetes. Sprague-Dawley rats were anesthetized, the abdominal (anterior) vagus nerve implanted, and various stimulation strategies applied to the nerve: (a) 15 Hz; (b) 4 kHz, or 40 kHz and; (c) a combination of 15 Hz and 40 kHz to directionally activate afferent or efferent vagal fibers. Following a glucose bolus (500 mg/kg, I.V.), stimulation strategies were applied (60 min) and serial blood samples taken. No stimulation was used as a crossover control sequence. Applying 15 Hz stimulation significantly increased glucose (+2.9 ± 0.2 mM·hr, p = .015) and glucagon (+17.1 ± 8.0 pg·hr/ml, p = .022), compared to no stimulation. Application of 4 kHz stimulation also significantly increased glucose levels (+1.5 ± 0.5 mM·hr, p = .049), while 40 kHz frequency stimulation resulted in no changes to glucose levels but did significantly lower glucagon (-12.3 ± 1.1 pg·hr/ml, p = .0009). Directional afferent stimulation increased glucose (+2.4 ± 1.5 mM·hr) and glucagon levels (+39.5 ± 15.0 pg·hr/ml). Despite hyperglycemia resulting when VNS, aVNS, and 4 kHz stimulation strategies were applied, the changes in insulin levels were not significant (p ≥ .05). In summary, vagus nerve stimulation modulates glycemia by effecting glucagon and insulin secretions, and high-frequency 40 kHz stimulation may have potential application for the treatment of type 2 diabetes.


Asunto(s)
Glucemia/análisis , Glucagón/sangre , Insulina/sangre , Estimulación del Nervio Vago , Animales , Glucosa/administración & dosificación , Secreción de Insulina , Masculino , Páncreas/metabolismo , Ratas Sprague-Dawley
6.
J Neural Eng ; 17(2): 026008, 2020 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-32101807

RESUMEN

OBJECTIVE: The efficacy of deep brain stimulation can be limited by factors including poor selectivity of stimulation, targeting error, and complications related to implant reliability and stability. We aimed to improve surgical outcomes by evaluating electrode leads with smaller diameter electrode and microelectrodes incorporated which can be used for assisting targeting. APPROACH: Electrode arrays were constructed with two different diameters of 0.65 mm and the standard 1.3 mm. Micro-electrodes were incorporated into the slim electrode arrays for recording spiking neural activity. Arrays were bilaterally implanted into the medial geniculate body (MGB) in nine anaesthetised cats for 24-40 h using stereotactic techniques. Recordings of auditory evoked field potentials and multi-unit activity were obtained at 1 mm intervals along the electrode insertion track. Insertion trauma was evaluated histologically. MAIN RESULTS: Evoked auditory field potentials were recorded from ring and micro-electrodes in the vicinity of the medial geniculate body. Spiking activity was recorded from 81% of the microelectrodes approaching the MGB. Histological examination showed localized surgical trauma along the implant. The extent of haemorrhage surrounding the track was measured and found to be significantly reduced with the slim electrodes (541 ± 455 µm vs. 827 ± 647 µm; P < 0.001). Scoring of the trauma, focusing on tissue disruption, haemorrhage, oedema of glial parenchyma and pyknosis, revealed a significantly lower trauma score for the slim electrodes (P < 0.0001). SIGNIFICANCE: The slim electrodes reduced the extent of acute trauma, while still providing adequate electrode impedance for both stimulating and recording, and providing the option to target stimulate smaller volumes of tissue. The incorporation of microelectrodes into the electrode array may allow for a simplified, single-step surgical approach where confirmatory micro-targeting is done with the same lead used for permanent implantation.


Asunto(s)
Estimulación Encefálica Profunda , Animales , Gatos , Impedancia Eléctrica , Electrodos Implantados , Microelectrodos , Reproducibilidad de los Resultados
7.
J Neural Eng ; 16(6): 066002, 2019 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-31266002

RESUMEN

OBJECTIVE: With the strong drive towards miniaturization of active implantable medical devices and the need to improve the resolution of neural stimulation arrays, there is keen interest in the manufacture of small electrodes capable of safe, continuous stimulation. Traditional materials such as platinum do not possess the necessary electrochemical properties to stimulate neurons safely when electrodes are very small (i.e. typically less than about 300 µm (78 400 µm2)). While there are several commercially viable alternative electrode materials such as titanium nitride and iridium oxide, an attractive approach is modification of existing Pt arrays via a high electrochemical capacitance material coating. Such a composite electrode could still take advantage of the wide range of fabrication techniques used to make platinum-based devices. The coating, however, must be biocompatible, exhibit good adhesion and ideally be long lasting when implanted in the body. APPROACH: Platinum foils were roughened to various degrees with regular arrays of laser milled pits. Conducting diamond films were grown on the foils by microwave plasma chemical vapor deposition. The adhesion strength of the films to the platinum was assessed by prolonged sonication and accelerated aging. Electrochemical properties were evaluated and compared to previous work. MAIN RESULTS: In line with previous results, diamond coatings increased the charge injection capacity of the platinum foil by more than 300% after functionalization within an oxygen plasma. Roughening of the underlying platinum substrate by laser milling was required to generate strong adhesion between the diamond and the Pt foil. Electrical stress testing, near the limits of safe operation, showed that the diamond films were more electrochemically stable than platinum controls. SIGNIFICANCE: The article describes a new method to protect platinum electrodes from degradation in vivo. A 300% increase in charge injection means that device designers can safely employ diamond coated platinum stimulation electrodes at much smaller sizes and greater density than is possible for platinum.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Diamante/química , Capacidad Eléctrica , Técnicas Electroquímicas/métodos , Nanotecnología/métodos , Platino (Metal)/química , Técnicas Electroquímicas/instrumentación , Miniaturización/instrumentación , Miniaturización/métodos , Nanotecnología/instrumentación
8.
J Neural Eng ; 15(4): 041004, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29756600

RESUMEN

OBJECTIVE: Given the rapid expansion of the field of neural stimulation and the rigorous regulatory approval requirements required before these devices can be applied clinically, it is important that there is clarity around conducting preclinical safety and efficacy studies required for the development of this technology. APPROACH: The present review examines basic design principles associated with the development of a safe neural stimulator and describes the suite of preclinical safety studies that need to be considered when taking a device to clinical trial. MAIN RESULTS: Neural stimulators are active implantable devices that provide therapeutic intervention, sensory feedback or improved motor control via electrical stimulation of neural or neuro-muscular tissue in response to trauma or disease. Because of their complexity, regulatory bodies classify these devices in the highest risk category (Class III), and they are therefore required to go through a rigorous regulatory approval process before progressing to market. The successful development of these devices is achieved through close collaboration across disciplines including engineers, scientists and a surgical/clinical team, and the adherence to clear design principles. Preclinical studies form one of several key components in the development pathway from concept to product release of neural stimulators. Importantly, these studies provide iterative feedback in order to optimise the final design of the device. Key components of any preclinical evaluation include: in vitro studies that are focussed on device reliability and include accelerated testing under highly controlled environments; in vivo studies using animal models of the disease or injury in order to assess efficacy and, given an appropriate animal model, the safety of the technology under both passive and electrically active conditions; and human cadaver and ex vivo studies designed to ensure the device's form factor conforms to human anatomy, to optimise the surgical approach and to develop any specialist surgical tooling required. SIGNIFICANCE: The pipeline from concept to commercialisation of these devices is long and expensive; careful attention to both device design and its preclinical evaluation will have significant impact on the duration and cost associated with taking a device through to commercialisation. Carefully controlled in vitro and in vivo studies together with ex vivo and human cadaver trials are key components of a thorough preclinical evaluation of any new neural stimulator.


Asunto(s)
Estimulación Encefálica Profunda/métodos , Diseño de Equipo/métodos , Neuroestimuladores Implantables , Animales , Estimulación Encefálica Profunda/instrumentación , Estimulación Encefálica Profunda/tendencias , Diseño de Equipo/tendencias , Humanos , Neuroestimuladores Implantables/tendencias , Enfermedades del Sistema Nervioso/fisiopatología , Enfermedades del Sistema Nervioso/terapia , Resultado del Tratamiento
9.
Invest Ophthalmol Vis Sci ; 59(3): 1410-1424, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-29625464

RESUMEN

Purpose: Following successful clinical outcomes of the prototype suprachoroidal retinal prosthesis, Bionic Vision Australia has developed an upgraded 44-channel suprachoroidal retinal prosthesis to provide a wider field of view and more phosphenes. The aim was to evaluate the preclinical passive safety characteristics of the upgraded electrode array. Methods: Ten normal-sighted felines were unilaterally implanted with an array containing platinum electrodes (44 stimulating and 2 returns) on a silicone carrier near the area centralis. Clinical assessments (color fundus photos, optical coherence tomography, full-field electroretinography, intraocular pressure) were performed under anesthesia prior to surgery, and longitudinally for up to 20 weeks. Histopathology grading of fibrosis and inflammation was performed in two animals at 13 to 15 weeks. Results: Eight animals showed safe electrode array insertion (good retinal health) and good conformability of the array to the retinal curvature. Eight animals demonstrated good mechanical stability of the array with only minor (<2 disc diameters) lateral movement. Four cases of surgical or stability complications occurred due to (1) bulged choroid during surgery, (2) hemorrhage from a systemic bleeding disorder, (3) infection, and (4) partial erosion of thin posterior sclera. There was no change in retinal structure or function (other than that seen at surgery) at endpoint. Histopathology showed a mild foreign body response. Electrodes were intact on electrode array removal. Conclusions: The 44-channel suprachoroidal electrode array has an acceptable passive safety profile to proceed to clinical trial. The safety profile is expected to improve in human studies, as the complications seen are specific to limitations (anatomic differences) with the feline model.


Asunto(s)
Coroides/cirugía , Electrodos Implantados , Microelectrodos , Implantación de Prótesis , Retina/cirugía , Prótesis Visuales , Animales , Gatos , Modelos Animales de Enfermedad , Electrodos Implantados/efectos adversos , Implantación de Prótesis/efectos adversos , Prótesis Visuales/efectos adversos
10.
Artif Organs ; 40(3): E12-24, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26416723

RESUMEN

Successful visual prostheses require stable, long-term attachment. Epiretinal prostheses, in particular, require attachment methods to fix the prosthesis onto the retina. The most common method is fixation with a retinal tack; however, tacks cause retinal trauma, and surgical proficiency is important to ensure optimal placement of the prosthesis near the macula. Accordingly, alternate attachment methods are required. In this study, we detail a novel method of magnetic attachment for an epiretinal prosthesis using two prostheses components positioned on opposing sides of the retina. The magnetic attachment technique was piloted in a feline animal model (chronic, nonrecovery implantation). We also detail a new method to reliably control the magnet coupling force using heat. It was found that the force exerted upon the tissue that separates the two components could be minimized as the measured force is proportionately smaller at the working distance. We thus detail, for the first time, a surgical method using customized magnets to position and affix an epiretinal prosthesis on the retina. The position of the epiretinal prosthesis is reliable, and its location on the retina is accurately controlled by the placement of a secondary magnet in the suprachoroidal location. The electrode position above the retina is less than 50 microns at the center of the device, although there were pressure points seen at the two edges due to curvature misalignment. The degree of retinal compression found in this study was unacceptably high; nevertheless, the normal structure of the retina remained intact under the electrodes.


Asunto(s)
Imanes/química , Implantación de Prótesis/métodos , Retina/cirugía , Prótesis Visuales/química , Animales , Gatos , Electrodos Implantados , Calor , Magnetismo/métodos , Diseño de Prótesis , Retina/ultraestructura
11.
Artículo en Inglés | MEDLINE | ID: mdl-26737881

RESUMEN

The effect of miniaturizing the electrode lead for Deep Brain Stimulation (DBS) therapy was investigated in this work. A direct comparison was made between a miniature lead (0.65 mm diameter) and a lead of standard size (1.3 mm). Acute in vivo implantation in two cat brains was performed to evaluate surgical trauma and confirm capacity to target thalamic nuclei. Insertion into a homogeneous gel model of neural tissue was used to compare insertion forces while visualizing the process. The standard size cannula, used first to guide lead insertion, required substantially higher insertion force compared with the miniature version and produced a significantly larger region of tissue disruption. The characteristic hemorrhage and edema extended 119-352 µm from the implanted track surface of the miniature lead and cannula, while these extended 311-571 µm for the standard size lead and cannula. A miniature DBS implant can reduce the extent of trauma and could potentially help improve neural function preservation after functional neurosurgery.


Asunto(s)
Estimulación Encefálica Profunda/métodos , Electrodos Implantados , Animales , Encéfalo/patología , Encéfalo/cirugía , Gatos , Cuerpos Geniculados/patología , Microelectrodos , Procedimientos Neuroquirúrgicos
12.
PLoS One ; 9(12): e115239, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25521292

RESUMEN

UNLABELLED: Retinal visual prostheses ("bionic eyes") have the potential to restore vision to blind or profoundly vision-impaired patients. The medical bionic technology used to design, manufacture and implant such prostheses is still in its relative infancy, with various technologies and surgical approaches being evaluated. We hypothesised that a suprachoroidal implant location (between the sclera and choroid of the eye) would provide significant surgical and safety benefits for patients, allowing them to maintain preoperative residual vision as well as gaining prosthetic vision input from the device. This report details the first-in-human Phase 1 trial to investigate the use of retinal implants in the suprachoroidal space in three human subjects with end-stage retinitis pigmentosa. The success of the suprachoroidal surgical approach and its associated safety benefits, coupled with twelve-month post-operative efficacy data, holds promise for the field of vision restoration. TRIAL REGISTRATION: Clinicaltrials.gov NCT01603576.


Asunto(s)
Procedimientos Quirúrgicos Oftalmológicos/instrumentación , Retinitis Pigmentosa/cirugía , Prótesis Visuales/efectos adversos , Coroides/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Oftalmológicos/métodos , Complicaciones Posoperatorias , Esclerótica/cirugía
13.
J Neural Eng ; 11(4): 046017, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24965866

RESUMEN

OBJECTIVE: The research goal is to develop a wide-field retinal stimulating array for prosthetic vision. This study aimed at evaluating the efficacy of a suprachoroidal electrode array in evoking visual cortex activity after long term implantation. APPROACH: A planar silicone based electrode array (8 mm × 19 mm) was implanted into the suprachoroidal space in cats (ntotal = 10). It consisted of 20 platinum stimulating electrodes (600 µm diameter) and a trans-scleral cable terminated in a subcutaneous connector. Three months after implantation (nchronic = 6), or immediately after implantation (nacute = 4), an electrophysiological study was performed. Electrode total impedance was measured from voltage transients using 500 µs, 1 mA pulses. Electrically evoked potentials (EEPs) and multi-unit activity were recorded from the visual cortex in response to monopolar retinal stimulation. Dynamic range and cortical activation spread were calculated from the multi-unit recordings. MAIN RESULTS: The mean electrode total impedance in vivo following 3 months was 12.5 ± 0.3 kΩ. EEPs were recorded for 98% of the electrodes. The median evoked potential threshold was 150 nC (charge density 53 µC cm(-2)). The lowest stimulation thresholds were found proximal to the area centralis. Mean thresholds from multiunit activity were lower for chronic (181 ± 14 nC) compared to acute (322 ± 20 nC) electrodes (P < 0.001), but there was no difference in dynamic range or cortical activation spread. SIGNIFICANCE: Suprachoroidal stimulation threshold was lower in chronic than acute implantation and was within safe charge limits for platinum. Electrode-tissue impedance following chronic implantation was higher, indicating the need for sufficient compliance voltage (e.g. 12.8 V for mean impedance, threshold and dynamic range). The wide-field suprachoroidal array reliably activated the retina after chronic implantation.


Asunto(s)
Coroides/fisiología , Implantación de Prótesis , Retina/fisiología , Corteza Visual/fisiología , Prótesis Visuales , Animales , Gatos , Estimulación Eléctrica , Electrodos , Electrodos Implantados , Diseño de Prótesis
14.
PLoS One ; 9(5): e97182, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24853376

RESUMEN

PURPOSE: To assess the safety and efficacy of chronic electrical stimulation of the retina with a suprachoroidal visual prosthesis. METHODS: Seven normally-sighted feline subjects were implanted for 96-143 days with a suprachoroidal electrode array and six were chronically stimulated for 70-105 days at levels that activated the visual cortex. Charge balanced, biphasic, current pulses were delivered to platinum electrodes in a monopolar stimulation mode. Retinal integrity/function and the mechanical stability of the implant were assessed monthly using electroretinography (ERG), optical coherence tomography (OCT) and fundus photography. Electrode impedances were measured weekly and electrically-evoked visual cortex potentials (eEVCPs) were measured monthly to verify that chronic stimuli were suprathreshold. At the end of the chronic stimulation period, thresholds were confirmed with multi-unit recordings from the visual cortex. Randomized, blinded histological assessments were performed by two pathologists to compare the stimulated and non-stimulated retina and adjacent tissue. RESULTS: All subjects tolerated the surgical and stimulation procedure with no evidence of discomfort or unexpected adverse outcomes. After an initial post-operative settling period, electrode arrays were mechanically stable. Mean electrode impedances were stable between 11-15 kΩ during the implantation period. Visually-evoked ERGs & OCT were normal, and mean eEVCP thresholds did not substantially differ over time. In 81 of 84 electrode-adjacent tissue samples examined, there were no discernible histopathological differences between stimulated and unstimulated tissue. In the remaining three tissue samples there were minor focal fibroblastic and acute inflammatory responses. CONCLUSIONS: Chronic suprathreshold electrical stimulation of the retina using a suprachoroidal electrode array evoked a minimal tissue response and no adverse clinical or histological findings. Moreover, thresholds and electrode impedance remained stable for stimulation durations of up to 15 weeks. This study has demonstrated the safety and efficacy of suprachoroidal stimulation with charge balanced stimulus currents.


Asunto(s)
Estimulación Eléctrica , Retina/fisiología , Corteza Visual/fisiología , Prótesis Visuales/normas , Animales , Gatos , Impedancia Eléctrica , Electrodos Implantados , Electrorretinografía , Inmunohistoquímica , Modelos Lineales , Retina/patología , Tomografía de Coherencia Óptica
15.
Clin Exp Ophthalmol ; 42(7): 665-74, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24330322

RESUMEN

BACKGROUND: Current surgical techniques for retinal prosthetic implantation require long and complicated surgery, which can increase the risk of complications and adverse outcomes. METHOD: The suprachoroidal position is known to be an easier location to access surgically, and so this study aimed to develop a surgical procedure for implanting a prototype suprachoroidal retinal prosthesis. The array implantation procedure was developed in 14 enucleated eyes. A full-thickness scleral incision was made parallel to the intermuscular septum and superotemporal to the lateral rectus muscle. A pocket was created in the suprachoroidal space, and the moulded electrode array was inserted. The scleral incision was closed and scleral anchor point sutured. In 9 of the 14 eyes examined, the device insertion was obstructed by the posterior ciliary neurovascular bundle. Subsequently, the position of this neurovascular bundle in 10 eyes was characterized. Implantation and lead routing procedure was then developed in six human cadavers. The array was tunnelled forward from behind the pinna to the orbit. Next, a lateral canthotomy was made. Lead fixation was established by creating an orbitotomy drilled in the frontal process of the zygomatic bone. The lateral rectus muscle was detached, and implantation was carried out. Finally, pinna to lateral canthus measurements were taken on 61 patients in order to determine optimal lead length. RESULTS: These results identified potential anatomical obstructions and informed the anatomical fitting of the suprachoroidal retinal prosthesis. CONCLUSION: As a result of this work, a straightforward surgical approach for accurate anatomical suprachoroidal array and lead placement was developed for clinical application.


Asunto(s)
Coroides/cirugía , Procedimientos Quirúrgicos Oftalmológicos , Implantación de Prótesis/métodos , Prótesis Visuales , Cadáver , Femenino , Humanos , Masculino , Ensayo de Materiales , Colgajos Quirúrgicos , Técnicas de Sutura , Donantes de Tejidos
16.
J Vis Exp ; (78)2013 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-23963336

RESUMEN

With the recent development of retinal prostheses, it is important to develop reliable techniques for assessing the safety of these devices in preclinical studies. However, the standard fixation, preparation, and automated histology procedures are not ideal. Here we describe new procedures for evaluating the health of the retina directly adjacent to an implant. Retinal prostheses feature electrode arrays in contact with eye tissue. Previous methods have not been able to spatially localize the ocular tissue adjacent to individual electrodes within the array. In addition, standard histological processing often results in gross artifactual detachment of the retinal layers when assessing implanted eyes. Consequently, it has been difficult to assess localized damage, if present, caused by implantation and stimulation of an implanted electrode array. Therefore, we developed a method for identifying and localizing the ocular tissue adjacent to implanted electrodes using a (color-coded) dye marking scheme, and we modified an eye fixation technique to minimize artifactual retinal detachment. This method also rendered the sclera translucent, enabling localization of individual electrodes and specific parts of an implant. Finally, we used a matched control to increase the power of the histopathological assessments. In summary, this method enables reliable and efficient discrimination and assessment of the retinal cytoarchitecture in an implanted eye.


Asunto(s)
Inmunohistoquímica/métodos , Retina/citología , Prótesis Visuales , Electrodos Implantados , Humanos , Retina/patología
17.
Invest Ophthalmol Vis Sci ; 54(5): 3751-62, 2013 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-23611996

RESUMEN

PURPOSE: The safety of chronic implantation of a retinal prosthesis in the suprachoroidal space has not been established. This study aimed to determine the safety of a wide-field suprachoroidal electrode array following chronic implantation using histopathologic techniques and electroretinography. METHODS: A platinum electrode array in a wide silicone substrate was implanted unilaterally in the suprachoroidal space in adult cats (n = 7). The lead and connector were tunneled out of the orbit and positioned subcutaneously. Postsurgical recovery was assessed using fundus photography and electroretinography (ERG). Following 3 months of passive implantation, the animals were terminated and the eyes assessed for the pathologic response to implantation. RESULTS: The implant was mechanically stable in the suprachoroidal space during the course of the study. The implanted eye showed a transient increase in ERG response amplitude at 2 weeks, which returned to normal by 3 months. Pigmentary changes were observed at the distal end of the implant, near the optic disc. Histopathologic assessment revealed a largely intact retina and a thin fibrous capsule around the suprachoroidal implant cavity. The foreign body response was minimal, with sporadic presence of macrophages and no active inflammation. All implanted eyes were negative for bacterial or fungal infections. A midgrade granuloma and thick fibrous buildup surrounded the extraocular cable. Scleral closure was maintained in six of seven eyes. There were no staphylomas or choroidal incarceration. CONCLUSIONS: A wide-field retinal prosthesis was stable and well tolerated during long-term suprachoroidal implantation in a cat model. The surgical approach was reproducible and overall safe.


Asunto(s)
Coroides/fisiología , Reacción a Cuerpo Extraño/prevención & control , Complicaciones Posoperatorias/prevención & control , Implantación de Prótesis/métodos , Tretinoina/fisiología , Prótesis Visuales , Animales , Gatos , Electrodos Implantados/efectos adversos , Electrorretinografía , Fondo de Ojo , Modelos Animales , Implantación de Prótesis/efectos adversos , Factores de Tiempo , Prótesis Visuales/efectos adversos
18.
Graefes Arch Clin Exp Ophthalmol ; 250(3): 399-407, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21874343

RESUMEN

BACKGROUND: Our research goal is to develop a safe, reproducible surgical approach for implantation of a wide-field retinal stimulating array. The aim of this study was to evaluate the pathological response to acute implantation of a functional prototype electrode array in the suprachoroidal space. METHODS: The surgical techniques to implant a 72 platinum electrode array fabricated on 8 × 13 × 0.4 mm polyimide and silicone substrate were developed in a pilot study in anesthetized cats. For the main study, nine eyes were implanted in vivo and unoperated eyes were used as controls. Surgery consisted of a temporal approach with a full-thickness scleral incision 5 mm posterior to the limbus. A suprachoroidal "pocket" was created, the electrode array inserted to sit beneath the area centralis, and placement was confirmed visually. The eyes were collected subsequently for histopathology. RESULTS: The array was consistently inserted into the suprachoroidal space beneath the area centralis in nine eyes. There was a significant hemorrhage in two cases where implantation was complicated by choroidal congestion. Retinal folding occurred only when the array tip was within 2.6 mm of the optic disc (p < 0.01). There was choroidal incarceration at the incision in six eyes and scleral distortion at the array edges in five. No cases were found where the implant breached the retina, choroid, or sclera. CONCLUSIONS: A large stimulation array can be reliably inserted into the suprachoroidal space without trauma to the neuroretina. These findings suggest that this is an appropriate surgical approach for the placement of an electrode array for use in retinal stimulation.


Asunto(s)
Coroides/cirugía , Terapia por Estimulación Eléctrica/instrumentación , Electrodos Implantados , Lesiones Oculares/diagnóstico , Prótesis Visuales , Animales , Gatos , Espacio Extracelular , Microelectrodos , Proyectos Piloto , Implantación de Prótesis , Retina/lesiones , Umbral Sensorial , Agudeza Visual/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...