Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biomater Investig Dent ; 11: 40311, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38645926

RESUMEN

Objective: To evaluate the penetration of a dye in root dentin after activation with different laser wavelengths. Materials: Palatal roots of 38 human molars were enlarged and disinfected. Irrigation activation was performed with an Er:YAG laser: @50 mJ, 15 Hz (Er:YAG); a 9.3 µm CO2 laser: @40% power (CO2); diode lasers 455 nm/970 nm: @0.8 W, 15 Hz (D455, D970) and 808/980 nm: @1 W (D808, D980) and compared to positive control: etching with 35% H3PO4 (POS); negative control: water (NEG) and conventional needle irrigation: NaOCl and ethylenediaminetetraacetic acid (EDTA) (CONV). Methylene blue solution was introduced in the canal and laser-activated or left untouched for 100 s before the roots were dried and cut into horizontal slices. Dye penetration was automatically calculated by color recognition of two samples per root third (n = 8 per group in each coronal, middle and apical root thirds). The presence and absence of a smear layer was checked in two additional samples of the negative and positive control under scanning electron microscopy (SEM). Results: Full-depth infiltration was not achieved in any group. Dye penetration in CONV was significantly less than in Er:YAG, CO2, POS, D455, D970, D808 and similar to NEG and D980 when results of different root thirds were pooled. Conclusion: Laser activation using certain parameters enhanced dye penetration compared to conventional needle irrigation with NaOCl and EDTA (CONV).

2.
Am J Dent ; 37(1): 39-46, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38458982

RESUMEN

PURPOSE: To investigate the differences between irrigant propagation and temperature changes using laser-activated irrigation (LAI) at different settings in an artificial root canal model. METHODS: Using an artificial resin root canal model, irrigant activation was achieved in 19 experimental groups with eight samples each. A 9,300 nm CO2 laser, two diode lasers with different settings (wavelengths 455, 808, 970, and 980 nm) were compared to 2,940 nm Er:YAG laser and traditional needle irrigation. Er:YAG and CO2 laser were activated in the pulpal chamber only, while diode lasers and needles were inserted into the main root canal. Lasers were activated for 5x 20 seconds resulting in 100 seconds of activation or rinsing for each sample. After each activation of 20 seconds, a photo was taken of the side canals and the propagation of the dye was measured with a digital measuring tool after calibration. Further, the temperature of the irrigant was reported after activation of 20 seconds and repeated 5 times. Data were checked for normality and statistically compared. RESULTS: All lasers increased the irrigant propagation compared to conventional irrigation. Significant differences were found between groups regarding propagation and temperature (P< 0.0027). Er:YAG and CO2 laser had similar effects on irrigant propagation in middle and apical located side-canals with specific power parameters and were superior to diode lasers and syringe irrigation. The irrigant's temperature increased significantly with the diode and CO2 lasers. CLINICAL SIGNIFICANCE: Diode lasers and CO2 lasers have not been established for irrigant activation. 9,300 nm CO2 lasers absorb well in water and were shown to introduce vapor bubble formation and streaming in water. Diode lasers are highly accepted in periodontics. The laser light is not absorbed in water but interacts with bacteria as well as soft tissues and contributes therefore to infection control. With a modified laser tip it was however possible to introduce cavitation and streaming in irrigants.


Asunto(s)
Dióxido de Carbono , Láseres de Estado Sólido , Láseres de Semiconductores , Prueba de Estudio Conceptual , Irrigantes del Conducto Radicular , Cavidad Pulpar/microbiología , Agua , Preparación del Conducto Radicular/métodos
3.
Materials (Basel) ; 16(18)2023 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-37763602

RESUMEN

Objective: Testing the influence of various restorative materials (conventional or bulkfill composites) and filling techniques (single- or multi-layered techniques) on the in vitro marginal adaptation of large class II direct composites with supra and sub-gingival margins subjected to thermomechanical loading (TML). Methods: A total of 40 prepared teeth were attributed randomly to five experimental groups. In Group 1, restorations were made of multi-layered high-viscosity conventional composite (Tetric EvoCeram); in Groups 2 and 3, restorations were made of a high viscosity bulkfill composite (Tetric EvoCeram Bulk Fill) applied in one (Group 2) or three layers (Group 3); in Groups 4 and 5, restorations were made of a flowable bulkfill composite (SDR flow) applied in one (Group 4) or two layers (Group 5), covered with a layer of high-viscosity conventional composite (Ceram-X Universal). A single adhesive (OptiBond FL) was used in all groups. All specimens were submitted to a staged TML comprising three phases (2 × 500,000 and 1,000,000 cycles) at 50 N with 3350 thermal cycles (5 to 55 °C) every 500,000 cycles. The tooth-restoration interfaces on proximal surfaces were evaluated quantitatively by scanning electron microscopy, before and after each TML phase, hence at three timepoints (T0, T1, T2 and T3). The following segments were considered for evaluation: proximal, vertical enamel margins (assessed individually on both restoration sides), cervical enamel (restoration side above CEJ) and cervical dentin margin (restoration side below the CEJ). Results: TML induced a significant reduction in continuous adaptation at both enamel and dentin margins in all groups, with percentages of continuous margins ranging from 75.2 to 91.8% at T0, and decreasing to values ranging from 21.3 to 73.9% at T3. Both composite systems and layering protocols had a significant influence on marginal adaptation of the restorations, with statistical associations depending on the restoration group and the timepoint considered. Defective margins in enamel were all of a cohesive nature with micro-fractures, while in dentin, interfacial gaps were the main defect observed. Conclusions/Clinical significance: The present results highlighted significant degradation of marginal adaption after long-term in vitro fatigue test using materials even with high-viscosity conventional resin composites, applied with a proper layering approach in medium-large sub-gingival cavities. While no significant differences were observed at the dentin cervical margins, there was a tendency for better adaptation at the enamel margin when using a higher modulus material with a multi-layered technique.

4.
Dent J (Basel) ; 11(4)2023 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37185467

RESUMEN

Purpose: To evaluate and compare the tooth-whitening potential of five over-the-counter (OTC), peroxide-free dental bleaching methods as well as an experimental tooth-whitening solution containing 0.1% hydrogen peroxide complexed with doping agents with a gold standard (positive control) containing 16% carbamide peroxide. Material and Methods: Eighty permanent bovine incisor teeth were randomly allocated to eight different groups. Two teeth from each group were immerged into five staining solutions represented by coffee, tea, red wine, and curry mixed in warm oil or distilled water (control group) and stored at 37 °C for 28 days in an incubator. The teeth were then reallocated to the eight groups, resulting in ten samples per group, and each group was matched with a bleaching product. The bleaching procedures were executed following the manufacturer's recommendations. The color of each sample was assessed over a white and black background using a quantitative numerical measurement approach with a calibrated spectrophotometer. Spectrophotometric measurements were performed after exposing the teeth to the bleaching agent for 60 min (T2), 100 min (T3), and 200 min (T4), and ΔE00 was calculated. Results: When analyzed over a white background, the mean ΔE00 values ranged from 2.14 (placebo) to 6.32 (Opalescence PF). When analyzed over a black background, the mean ΔE00 values ranged from 2.31 (placebo) to 5.78 (Opalescence PF). Statistically significant ΔE00 color changes over time for the eight groups and five staining solutions at T1 and T4 were assessed for both backgrounds using repeated ANOVA followed by Fisher's LSD post hoc test (p-value < 0.01). Conclusions: All tested over-the-counter whitening kits except one exhibited positive color variation. However, the individual performance differed vastly from one brand to the other, and the overall performance was less effective compared to the conventional carbamide-peroxide-based positive control.

5.
Am J Dent ; 36(1): 21-24, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36917711

RESUMEN

PURPOSE: To evaluate in a retrospective practice-based clinical study, the effects of additional laser therapy on side effects following the removal of all four impacted third molars. The secondary objective was, based on those results, to rationalize a protocol for low-level laser therapy (LLLT) in terms of irradiation settings. METHODS: 96 subjects requiring simultaneous surgical removal of the four third molars were treated from 2017 to 2019. For each subject, one side was randomly assigned to laser treatment, the other receiving the placebo. LLLT was performed by applying an infrared diode laser of 810 nm. In the LLLT irradiated side of the mouth, three groups were randomly assigned to a specific protocol of irradiation. Controllable settings include power, energy density and also scanning technique. The main outcome was pain, registered on a visual analog scale (VAS) performed by the patients. RESULTS: There was a statistically significant difference for one of the tested protocols. Self-reported annoyance and pain scores were lower for the side submitted to a 30-second laser radiation at a power of 0.3 W with the slow scanning technique (P< 0.05). CLINICAL SIGNIFICANCE: The present treatment approach, using a one-time low-level laser therapy intra-oral application, showed a beneficial effect of LLLT reducing pain after third molar surgery, which should be confirmed through further study.


Asunto(s)
Terapia por Luz de Baja Intensidad , Humanos , Terapia por Luz de Baja Intensidad/efectos adversos , Terapia por Luz de Baja Intensidad/métodos , Tercer Molar/cirugía , Dolor Postoperatorio/etiología , Dolor Postoperatorio/terapia , Estudios Retrospectivos , Extracción Dental/efectos adversos , Extracción Dental/métodos
6.
J Prosthet Dent ; 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36333176

RESUMEN

STATEMENT OF PROBLEM: Three-dimensionally (3D)-printed composite resins have been marketed as materials for definitive restorations. However, limited information is available regarding the stability of the adhesive interface and the efficiency of 3D-printed composite resins. PURPOSE: The purpose of this in vitro study was to evaluate the integrity of the marginal adhesive interface before and after thermal and mechanical fatigue of an initial formulation of a 3D-printed composite resin and to evaluate the efficiency of this manufacturing method. MATERIAL AND METHODS: Freshly extracted molars were prepared for onlays and adhesively restored with either 3D-printed composite resin (VarseoSmile Crown Plus) (Group 3D), milled composite resin (Tetric CAD) (Group MCOMP), milled PMMA (Telio CAD) (Group PMMA), and milled lithium disilicate (IPS e.max CAD) (Group EM). Marginal analysis was performed under a scanning electron microscope before and after fatigue by thermomechanical cyclic loading, and initial and terminal percentages of continuous margin (%CM) were compared. The time required for the production of each type of restoration was recorded, and the production costs were also compared. RESULTS: Before aging, 3D, MCOMP, and EM presented comparable values of %CM (69.8%, 75.9%, and 63.1%, respectively) that were statistically significantly higher (P<.05) than those of PMMA (45.1%). After aging, 3D and EM had comparable results (44.7% and 43.7%, respectively), which were lower than those of the MCOMP group (68.5%) but higher than those of the PMMA group (20.5%). Regarding time efficiency, 3D printing took less time than MCOMP or PMMA if more than 8 restorations were fabricated. For the production costs, 3D printing was 5.5, 8.7, and 10.2 times less expensive than PMMA, MCOMP, and EM, respectively. The initial equipment cost was also lower for the additive manufacturing method. However, 3D printing did not always considerably reduce waste. CONCLUSIONS: In terms of marginal adaptation, the evaluated initial formulation of a 3D-printed composite resin behaved similarly to other well-established definitive restoration materials and better than milled PMMA, both before and after fatigue. Three-dimensionally printed resins present advantages in terms of equipment and consumable costs, even for a single restoration, but also for production time when more than 8 restorations were fabricated.

7.
Am J Dent ; 35(3): 123-127, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35798705

RESUMEN

PURPOSE: To evaluate the effect of light-curing exposure time and location on polymerization of a restorative bulk-fill resin composite to lute endocrowns. METHODS: A light-cured restorative bulk-fill resin composite (Filtek One Bulk Fill) was submitted to direct light-curing by a high-power LED light-curing unit for 20 seconds as the positive control group (n= 10). Five more groups (n= 10) were light-cured in a natural tooth mold from two sites (labial and lingual) through a nanohybrid resin composite CAD-CAM restoration (Lava Ultimate A2 LT), for different irradiation times: 90 seconds per site, 40 seconds per site, 30 seconds per site, 20 seconds per site and 10 seconds per site. Vickers microhardness measurements were made at two different depths and test/control ratios were calculated. Ratios of 0.8 were considered as an adequate level of curing. A quantile regression was run to identify the minimally sufficient time of light-curing, and a two-way ANOVA was used to compare the results to previous findings and evaluate the effect of curing location. RESULTS: Analysis showed that 40 seconds x 2 is the minimal irradiation time that presents a test/control ratio above 0.8. Quantile regressions showed that the required irradiation time to reach a test/control ratio of 0.8 at a confidence level of 95% is 41.5 seconds and 39.2 seconds at 200 µm and 500 µm depths in the luting agent, respectively. There was no statistically significant difference between microhardness of the two depths except for the irradiation time of 10 seconds. The two-site to three-site light curing comparison showed no statistically significant difference except for the 90-second time. CLINICAL SIGNIFICANCE: Systematic light-curing through the labial, lingual and occlusal surfaces of thick indirect restorations is not always required for sufficient polymerization and can even waste valuable clinical time especially in the case of multiple restorations luted with resin composites.


Asunto(s)
Luces de Curación Dental , Curación por Luz de Adhesivos Dentales , Resinas Compuestas , Diseño Asistido por Computadora , Cementos Dentales , Materiales Dentales , Cementos de Ionómero Vítreo , Dureza , Curación por Luz de Adhesivos Dentales/métodos , Ensayo de Materiales , Polimerizacion , Propiedades de Superficie
8.
Clin Exp Dent Res ; 8(1): 282-286, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34647425

RESUMEN

OBJECTIVES: To compare gloss retention of four different resin composites with their corresponding CAD/CAM composite blocks. MATERIALS AND METHODS: Four direct resin composites (Filtek Supreme XTE A2 Body (3M, USA), Tetric EvoCeram A2 (Ivoclar Vivadent, Liechtenstein), GrandioSO x-tra A2 (VOCO, Germany), G-aenial Universal A2 (GC, Japan)), and their corresponding CAD/CAM composite blocks were tested. A total of 288 samples were prepared and three different tests were performed: brushing, exposition to acidic fluoride gel and exposition to alcoholic solution. Gloss values were obtained by means of a glossmeter at T0 before aging and T60 after 1 h of aging. RESULTS: Mean gloss values ranged from 0.9 after brushing tests to 79.0 after the alcohol test witnessing a high gloss variability depending on the materials and the aging test. Statistical analysis by means of two-way repeated measures ANOVA followed by Fisher's LSD post-hoc test revealed significant differences between materials, storage media, and their interactions. CONCLUSION: Gloss retention seems to be dependent on the composite type (direct or CAD/CAM block) and composite brand and varies in respect to the type of aging. CAD/CAM materials showed a higher resistance toward alcohol exposure.


Asunto(s)
Diseño Asistido por Computadora , Cepillado Dental , Japón , Ensayo de Materiales , Propiedades de Superficie , Cepillado Dental/métodos
9.
J Dent ; 115: 103828, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34678337

RESUMEN

OBJECTIVES: to test if cavity dimensions and restorative protocol have potential to influence in-vitro adaptation of class II restoration after simulated thermo-occlusal stressing. METHODS: A total of 32 prepared teeth were randomly assigned to one of the 4 experimental groups depending on cavity size, composite system and filling technique; group 1: small cavity and multi-layered conventional restorative composite (Tetric Evo-ceram: TEC), group 2: small cavity and flowable bulk-filled composite (SDRFlow: SDR) + one single occlusal layer of conventional restorative composite (TEC), group 3: large cavity and multilayered conventional restorative composite (TEC) and group 4: large cavity and bulk-filled flowable composite (SDR) + one single occlusal layer conventional restorative composite (TEC). All specimens were submitted to 500'000 cycles of thermomechanical loading (50 N, 5 to 55 °C). The proximal tooth-restoration interface was analyzed quantitatively by SEM, prior and after thermomechanical loading. RESULTS: Before loading, continuous enamel adaptation varied from 61.49% (Gr 1) to 68.39% (Gr 4) proximally and from 50.93% (Gr2) to 68.65% (Gr1) cervically, with no statistical difference among groups for both segments. After thermomechanical loading, continuous enamel adaptation varied from 36.6% (Gr2) to 46.6% (Gr1) proximally, without significant difference, and from 20.2% (Gr4) to 51.3% (Gr1) cervically; statistical differences in cervical enamel adaptation were found in-between groups 1 and 2 (p = 0.0479), 1 and 4 (P = 0.0116), 2 and 3 (p = 0.0028) and 3 and 4 (p = 0.001). Before loading, dentin continuous adaptation varied from 55.32% (Gr3) to 81.82% (Gr4) with statistical difference in-between those groups (p = 0.045); after loading, dentin continuous adaptation varied from 31.56% (gr2) to 51% (Gr4) with a statistical difference between those 2 groups (p = 0.019). The drop in adaptations values after loading was significant in all groups and segments. CONCLUSIONS: The impact of the restorative technique and cavity size on marginal adaptation appeared essentially after simulated fatigue for enamel adaptation. Cervical enamel and dentin continuous adaption of small and large bulk-filled restorations dropped significantly while the change was lower in layered restorations made of conventional restorative composite. CLINICAL SIGNIFICANCE: Restorations made with bulk-filled flowable composite behaved differently from layered ones using conventional resin composite, according to cavity size and loading.


Asunto(s)
Adaptación Marginal Dental , Restauración Dental Permanente , Resinas Compuestas , Preparación de la Cavidad Dental , Esmalte Dental , Restauración Dental Permanente/métodos , Propiedades de Superficie
10.
Polymers (Basel) ; 13(20)2021 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-34685348

RESUMEN

Objectives: The aim of this study was to evaluate the effect of different enamel surface treatments on the micro-shear bond strength. Materials and methods: Sixty-four approximal surfaces from freshly extracted molars were randomly assigned to eight groups, according to combinations of the following enamel surface treatments: ground or unground, 37.5% phosphoric acid etching time of 15 or 30 s, and with or without primer application. The same bonding agent (Optibond FL™ Adhesive, Kerr) was then used for all groups, and a 1.8 mm diameter resin composite (Harmonize™, Kerr) cylinder was built up on the bonded surface. Samples underwent a shear force test at a crosshead speed of 1 mm/min until failure. Bond strength was calculated, and failure modes were inspected under an optical microscope. Results: Bond-strength values ranged from 8.2 MPa for 15 s etched unground enamel with primer application to 19.6 MPa for 30 s etched ground enamel without primer application. ANOVA and Fisher's LSD post hoc tests revealed significant differences between the groups. Conclusions: Etching time and grinding have a statistically significant effect on the micro-shear bond strength of a three-step etch-and-rinse adhesive system on enamel. Primer application does not seem to be beneficial for enamel adhesion.

11.
Quintessence Int ; 53(1): 90-102, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34595910

RESUMEN

OBJECTIVES: To review the dynamic analytical elements used in the functional assessment of the stomatognathic system, summarize the available scientific evidence, and consider interrelations with body posture and cognition. METHOD AND MATERIALS: A thorough literature search was conducted using PubMed, the Cochrane Library database, and Google Scholar. Peer-reviewed articles and literature reviews provided up-to-date information addressing three topics: (a) the available knowledge and recent evidence on the relationship between the morphologic aspects of dental/craniofacial anatomy and oral function/dysfunction, (b) mandibular dynamics, considering mobility, functional activity, and existing methodologies of analysis, and (c) a possible correlation between the stomatognathic system, body posture, and cognition. RESULTS: Modern dentistry may be regarded as a human adaptation strategy, helping to conserve healthy teeth for much longer without risking overall health. It is futile to treat patients using a mechanistic, sectorial approach that misrepresents patient behavior and requests, just as it is to affirm the absence of any structure-function relationships. However, it is also evident that there is a lack of general consensus on the precise functional assessment of the stomatognathic system, mostly due to the methodologic heterogeneity employed and the high risk of bias. Despite the abundant evidence produced with the aim of providing solid arguments to define dynamic models of functional assessment of the stomatognathic system, it is yet to become highly empirical, based as it is on operator experience in daily clinical practice. CONCLUSIONS: Further efforts from the scientific and clinical community, with the help of progress in technology, remain should this gap be filled and should substantial data on differences between pathologic and physiologic dynamic models of function be provided. Dentistry needs to employ - on a larger scale - objective, dynamic methods of analysis for the functional evaluation of the stomatognathic system, embracing concepts of "personalized medicine" and "interprofessional collaborations."


Asunto(s)
Sistema Estomatognático , Humanos
12.
Quintessence Int ; 52(10): 920-932, 2021 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-34595913

RESUMEN

OBJECTIVES: To review the elements of static analysis in the functional assessment of the stomatognathic system, as promoted for more than a century by gnathologists, and summarize the available scientific evidence, including anthropologic observations. METHOD AND MATERIALS: A thorough search was conducted using PubMed, the Cochrane Library database, and Google Scholar. From peer-reviewed articles and other scientific literature, up-to-date information addressing three topics was identified: (a) the anthropologic perspective with particular consideration for the role of progressive dental wear over time, (b) descriptions of gnathologic principles and evidence on their scientific validity, and (c) the methodologic inaccuracies introduced by seeking to correlate variables directly rather than allowing for causal inference. RESULTS: For decades gnathology attempted to describe a structure-function correlation within the stomatognathic system by means of a model whose principles were static and mechanistic references. No scientific validation was ever achieved, placing clinical and research consensus out of reach. CONCLUSIONS: A historical perspective helps to place the fundamentals of gnathology into context: They were conceived to solve technical difficulties but were then assumed to be physiologic stereotypes. This misconception led to a decades-long promotion of mechanistic theories to describe oral function, but the evidence available today supports a more flexible and adaptable approach. Gnathologic arguments have been relegated to become exclusively of technical relevance in oral rehabilitation.


Asunto(s)
Sistema Estomatognático , Humanos
13.
J Mech Behav Biomed Mater ; 121: 104647, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34171717

RESUMEN

Cracked endodontically treated molars (ETMs) are commonly treated with full crowns. Less invasive techniques could include fiber-reinforced composite (FRC) base and adhesively bonded endocrowns. The purpose of this study was to assess the fatigue resistance of ETMs restored with CAD/CAM resin composite endocrowns and reinforced with different FRC bases. Cracks were simulated in fifty mandibular molars by cutting the teeth longitudinally and reassembling the two parts. After performing endodontic treatments and preparing cavities, teeth were restored in one of the following methods (n = 10). In Group 1, cavity floors were lined with 0.5 mm of flowable composite (Universal Injectable; GUI, shade A2). In Groups 2 and 3, the cavity floors were covered with one and three layers of FRC-net (ES Net) respectively, whereas in Groups 4 and 5 with 1 mm and 2 mm of flowable FRC-resin (EverX Flow Dentin; EXFD) respectively. Endocrowns (Cerasmart 270; CE, A2 HT) with 5 mm thickness were adhesively luted with preheated composite and all specimens were subjected to cyclic loading in water at 5 Hz, starting with a load of 600 N (5000 cycles), followed by stages of 1000, 1300, 1600, 1900, 2200 and 2500 at a maximum of 20 000 cycles each. Results were analyzed using Kaplan-Meier survival analysis and the Log-Rank test (p = 0.05). The fatigue failure load of ES Net applied in three layers (1617 N ± 371) or in one layer (1499 N ± 306), as well as EXFD applied in 2 mm (1496 N ± 264) or in 1 mm (1434 N ± 372) did not differ significantly (p > 0.05). Control teeth fractured at 1255 N ± 350 (p > 0.05). In the fiber-reinforced groups, restorable fractures were observed in 50%-80%, with only 30% deemed restorable in the control group. The fractures originated mainly at the occlusal contact points and the main crack propagated in the corono-apical direction. No crack origin (primary or secondary) starting from the artificial pre-existing crack was observed in fractured specimens. FRC bases did not improve the fatigue resistance of cracked ETMs, but favorably influenced the failure mode.


Asunto(s)
Cerámica , Resinas Compuestas , Diseño Asistido por Computadora , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Ensayo de Materiales , Diente Molar , Propiedades de Superficie
14.
Odontology ; 109(2): 368-375, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32886263

RESUMEN

The purpose of this in-vitro study was to evaluate the fracture resistance and failure mode of non-invasively reinforced endodontically treated mandibular molars. Sixty freshly extracted defect-free mandibular molars were divided into four experimental groups with extensive MOD cavities on endodontically treated teeth with different restoration types and one control group with intact teeth (n = 12). The groups were as follows: "Normal": direct resin composite; "Ring": glass fiber-reinforced strip (Dentapreg) wrapped around buccal and lingual walls followed by direct resin composite; "Inlay": indirect CAD/CAM resin composite inlay; "Onlay": indirect CAD/CAM resin composite onlay; "Intact": Intact teeth (Control). Tetric EvoCeram and Adhese Universal (Ivoclar Vivadent) were used for direct restorations and Tetric CAD (Ivoclar Vivadent) adhesively luted with Adhese Universal and Variolink Esthetic LC (Ivoclar Vivadent) were used for indirect restorations. All teeth were submitted to thermo-mechanical cyclic loading. All samples were then submitted to a compressive load until fracture. Fracture load was noted and teeth were analyzed to classify the failure mode as either catastrophic (C) or non-catastrophic (NC). No statistically significant difference was found between fracture strength of the five groups when all specimens were considered (p = 0.1461). Intact group showed the lowest percentage of catastrophic failures (41.67%). Ring group presents less catastrophic failures (75%) than Normal group (83.34%), and failures of indirect restorations-Inlay and Onlay-were almost all catastrophic (91.67% and 100%, respectively).


Asunto(s)
Fracturas de los Dientes , Diente no Vital , Resinas Compuestas , Análisis del Estrés Dental , Resistencia Flexional , Humanos , Incrustaciones , Diente Molar
15.
Polymers (Basel) ; 14(1)2021 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-35012106

RESUMEN

Analysis of marginal adaptation of dental adhesive interfaces using scanning electron microscopy has proven to be a powerful nondestructive method to evaluate the quality of adhesion. This methodology is, however, time-consuming and needs expensive equipment. The purpose of this study was to evaluate the possibility and efficiency of using a digital optical microscope (DOM) to perform marginal analysis and to compare it with the scanning electron microscope (SEM) analysis. Fifteen defect-free molars were selected for this study. Class V cavities were prepared and restored with resin composite, and epoxy replicas were obtained from silicone impressions of the restored teeth. Custom-made image analysis software was then used to measure the percentage of the noncontinuous margins (NCM) of each sample. To compare the DOM to the gold standard, SEM, each sample was analyzed 10 times using the DOM and three times using the SEM, by the same experienced operator. The repeatability coefficient and concordance were evaluated, and a Bland and Altman analysis was used for comparison of the two methods of measurements. To validate the DOM analysis method, an ANOVA approach (Gage R R) was used. Repeatability and reproducibility, which are two components of precision to validate the DOM analysis system, were calculated. For this, the same restorations were analyzed by two additional operators three times with the DOM. The duration of each step of the analysis using both methods was also recorded as a secondary outcome. Regarding the repeatability of each method, the Friedman test showed no statistically significant difference within the repetitions of measurements by SEM and DOM (p = 0.523 and p = 0.123, respectively). Moreover, the Bland-Altman analysis revealed a bias of 0.86 and concluded no statistically significant difference between the two methods, DOM and SEM. ANOVA evaluated DOM measurement system variation including the variances of repeatability and reproducibility that represented, respectively, 0.3% and 4% of the variance components. Reproducibility or inter-operator variability represented the principal source of variability with a statistically significant difference (p = 0.024). The time required for analysis with SEM was almost double that of DOM. The use of digital optical microscopy appears to be a valid alternative to the SEM for the analysis of marginal adaptation of dental adhesive interfaces. Further studies to evaluate the effect of training of operators in digital optical microscopy could reveal higher accuracy for this method and inter-operator agreement when experience is gained.

16.
Sci Rep ; 10(1): 20211, 2020 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-33214593

RESUMEN

To investigate the safety and efficacy of Self-Assembling Peptide P11-4 (SAP P11-4) compared to placebo or fluoride varnish (FV), a randomized, controlled, blinded, split-mouth study with sequential design was conducted. Subjects presenting two teeth with White-Spot-Lesions (WSLs) were included and teeth were randomly assigned to test or control. Control received placebo at baseline (D0) and test SAP P11-4, all received FV at Day 90 (D90). Standardized photographs were taken at each visit, and WSL size changes were morphometrically assessed. Hierarchical Linear Modelling, considering paired and sequential design, was used to test four hypotheses. SAP P11-4 lesions (test, D90-D0) showed significant WSL size reduction compared to placebo (control, D90-D0; p = 0.008) or FV (control, D180-D90; p = 0.001). Combination of SAP P11-4 and delayed FV after 90 days (test, D180-D0), showed a significant difference compared to FV alone (control D270-D90; p = 0.003). No significant difference on FV efficacy was found when SAP P11-4 was applied 3 months before FV (test D270-D90; control D270-D90, p = 0.70). SAP P11-4 treatment resulted in superior caries regression compared to either placebo or FV, and FV efficacy seems not to be affected by SAP P11-4. SAP P11-4 was found to be a safe and effective WSL treatment.


Asunto(s)
Cariostáticos/uso terapéutico , Caries Dental/tratamiento farmacológico , Fluoruros Tópicos/uso terapéutico , Oligopéptidos/uso terapéutico , Adolescente , Adulto , Femenino , Humanos , Masculino , Resultado del Tratamiento , Adulto Joven
17.
Popul Health Metr ; 18(1): 29, 2020 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-33168009

RESUMEN

BACKGROUND: Most western countries are facing relevant demographic changes, and the percentage of older people is destined to rise in the next decades. This fact is likely to affect the sustainability of healthcare systems significantly, mainly due to the connected issue of chronicity. METHODS: In this paper, using an extensive and comprehensive administrative dataset, we analyse the phenomenon of frequent use of emergency departments (ED) in the oldest region in Europe (i.e. Liguria) over 4 years (2013-2016). Two alternative approaches are used to define categories of ED users based on the intensity and frequency of accesses and splitting patients into different age groups. RESULTS: Results allow identifying clinical and socio-demographic risk-factors connected to different levels of ED utilisation and highlight the influential role played by chronic conditions (particularly mental disorders, respiratory diseases) and by multiple chronic conditions. CONCLUSIONS: The study aims at representing an informative tool to support policy-makers in setting proper policies addressed, on the one side, towards the potentially preventable frequent users and, on the other, towards those accessing due to complex medical conditions. The results can help in building a warning system to help general practitioners in the identification of potential frequent users and to develop preventive policies.


Asunto(s)
Envejecimiento , Enfermedad Crónica , Servicio de Urgencia en Hospital , Aceptación de la Atención de Salud , Anciano , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Aceptación de la Atención de Salud/estadística & datos numéricos , Estudios Retrospectivos
18.
Am J Dent ; 33(3): 157-160, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32470242

RESUMEN

PURPOSE: To compare the gloss retention of four resin based materials, two direct resin composites (Tetric EvoCeram and Filtek Supreme) and two indirect resin composite CAD-CAM blocks (Tetric CAD and Lava Ultimate). METHODS: 36 samples of 1 mm thickness were readied of each test material and manually polished with polishing discs (Sof-Lex) up to the finest grit size. Three gloss measurements per sample were taken (one every 120 degrees of sample rotation) by means of a glossmeter (Novo-Curve) for a total of 60 values obtained per tested material. Samples of each material were then randomly divided into three equal groups and aged with 75% alcohol (Group 1), amine fluoride gel (Elmex gelée) (Group 2) or mechanical brushing (Group 3). Another set of gloss measurements was performed on all samples after 1 hour of aging. Gloss values were statistically evaluated by means of repeated measures ANOVA and Fisher's LSD post-hoc tests. RESULTS: Gloss retention values ranged from 59.0 (Tetric EvoCeram) to 70.9 (Lava Ultimate) for alcohol, from 59.3 (Filtek Supreme) to 67.5 (Lava Ultimate) for Elmex gelèe and from 33.3 (Tetric EvoCeram) to 53.4 (Lava Ultimate) for mechanical brushing. Statistical analysis revealed: (1) significant difference between intial and final gloss values for all materials and groups; (2) significant difference between final gloss values of all the materials in the alcohol group; (3) significant difference between final gloss values of Lava Ultimate and all the other materials in the Elmex gelèe group; (4) significant difference between final gloss values of Lava Ultimate and Tetric CAD with the other tested materials in the brushing group. CLINICAL SIGNIFICANCE: Direct resin composites in general are widely used, and CAD-CAM resin composite materials are becoming progressively more accessible. Making the choice between direct and indirect techniques is still a challenge, and understanding the advantages of CAD-CAM resin composites in the form of higher gloss retention, which translates into higher durability of esthetics, may be one the parameters facilitating the decision.


Asunto(s)
Resinas Compuestas , Diseño Asistido por Computadora , Pulido Dental , Ensayo de Materiales , Propiedades de Superficie , Cepillado Dental
19.
Am J Dent ; 32(1): 39-42, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30834730

RESUMEN

PURPOSE: To evaluate the color stability of three resin-based materials continuously exposed to various staining agents. METHODS: 144 disc-shaped specimens were made of each of the three tested composites (Essentia, Brillant, Inspiro). Half of them were 1 mm thick, the other half 1.2 mm thick. The thicker group was then polished up to 4,000 grit and reduced to 1 mm thickness, also. All specimens, after 24-hour dry storage in an incubator, received an initial color measurement by means of a calibrated reflectance spectrophotometer (SpectroShade). Specimens were then divided into six groups (n=6) and immersed in five staining solutions or artificial saliva (control). All specimens were kept in an incubator at 37°C for 28 days. Staining solutions (red wine, curry mixed in water, curry mixed in oil, tea and coffee) were changed every 7th day to avoid bacteria or yeast contamination. After 28 days of storage, spectrophotometric measurements were repeated and L*a*b* scores once more recorded to determine the color (ΔE00) changes. RESULTS: All tested materials showed significant color changes after 28 days staining immersion. ΔE00 of polished samples varied from 1.1 (Essentia/distilled water measured over a white background as well as Essentia, Inspiro/distilled water measured over a black background) to 32.5 (Inspiro/wine measured over a white background). CLINICAL SIGNIFICANCE: Staining of restorative materials seems to be dependent on the composition of the product itself. Unpolished samples were more prone to staining than the polished ones.


Asunto(s)
Resinas Compuestas , , Decoloración de Dientes , Café , Color , Ensayo de Materiales , Coloración y Etiquetado , Propiedades de Superficie
20.
Oral Health Prev Dent ; 16(5): 439-444, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30460357

RESUMEN

PURPOSE: To determine in vitro the protection potential against discolouration of two OTC (over-the-counter) desensitising products on enamel and dentin in comparison to a standard toothpaste and water by means of a spectrophotometer. MATERIALS AND METHODS: A total of 96 samples of bovine enamel-dentin complex and 48 of bovine dentin were alternatively immersed in red wine, tea, coffee or water after having been treated by a sodium monofluorophosphate- and calcium phosphate-based product (Curodont Protect), an amine fluoride-based toothpaste (Elmex Red), a stannous chloride-based toothpaste (Elmex Protection Erosion) or distilled water (negative control). Initial (T0) and final colour (T1, after 4 weeks of immersion in staining solutions) of each specimen were assessed by a spectrophotometer. Statistical analysis was done by means of repeated measures ANOVA followed by Fisher's LSD post-hoc test. Differences between T0 and T1 were considered stastistically significant at p ≤ 0.05. RESULTS: When enamel samples were measured over a black background, ΔE00 values (T0-T1) varied from 2.2 (SD 0.7) for amine fluoride-based product/water to 53.9 (SD 7.6) for amine fluoride-based-product/red wine. When dentin samples were measured over a black background, ΔE00 values (T0-T1) varied from 5.4 (SD 0.9) stannous chloride based product/water to 61.6 (SD 3.7) amine fluoride-based product/red wine. CONCLUSION: Specifically, the application of the sodium monofluorophosphate was able to statistically significantly (p ≤ 0.05) reduce discolouration induced by the staining solutions tested only on the enamel-dentin complex, while distilled water and the stannous fluoride-based product were able to statistically significantly (p ≤ 0.05) reduce discolouration induced by the staining solutions tested in pure dentin samples.


Asunto(s)
Desensibilizantes Dentinarios/uso terapéutico , Decoloración de Dientes/prevención & control , Pastas de Dientes/uso terapéutico , Fosfatos de Calcio/uso terapéutico , Café , Esmalte Dental/diagnóstico por imagen , Dentina/diagnóstico por imagen , Fluoruros/uso terapéutico , Humanos , Técnicas In Vitro , Medicamentos sin Prescripción , Fosfatos/uso terapéutico , Espectrofotometría , , Compuestos de Estaño/uso terapéutico , Decoloración de Dientes/diagnóstico por imagen , Vino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...