Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
J Clin Med ; 13(13)2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38999362

RESUMEN

Maintaining balance comes naturally to healthy people. In subjects with vestibulopathy, even when compensated, and especially if it is bilateral, maintaining balance requires cognitive effort. Pupillometry is an established method of quantifying cognitive effort. Background/Objectives: We hypothesized that pupillometry would be able to capture the increased effort required to maintain posture in subjects with bilateral vestibulopathy in increasingly difficult conditions. Additionally, we hypothesized that the cognitive workload during balance tasks, indexed by pupil size, would decrease with the activation of the BionicVEST cochleo-vestibular implants. Methods: Subjects with a cochleo-vestibular implant as of March 2023 were recruited, excluding those with ophthalmological issues that precluded pupillometry. Pupillometry was performed using a validated modified videonystagmography system. Computed dynamic posturography and a Modified Clinical Test of Sensory Integration on Balance were performed while the pupil was recorded. Tests were first performed after 24 h of deactivating the vestibular component of the implant. Thereafter, it was reactivated, and after 1 h of rest, the tests were repeated. The pupil recording was processed using custom software and the mean relative pupil diameter (MRPD) was calculated. Results: There was an average of 10.7% to 24.2% reduction in MRPD when the vestibular implant was active, with a greater effect seen in tasks of moderate difficulty, and lesser effect when the task was easy or of great difficulty. Conclusions: Despite technical challenges, pupillometry appears to be a promising method of quantifying the cognitive effort required for maintaining posture in subjects with bilateral vestibulopathy before and after vestibular implantation.

2.
Eur Arch Otorhinolaryngol ; 281(7): 3433-3441, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38180608

RESUMEN

PURPOSE:  Vestibular implant electrode positioning close to the afferent nerve fibers is considered to be key for effective and selective electrical stimulation. However, accurate positioning of vestibular implant electrodes inside the semicircular canal ampullae is challenging due to the inability to visualize the target during the surgical procedure. This study investigates the accuracy of a new surgical protocol with real-time fluoroscopy and intraoperative CT imaging, which facilitates electrode positioning during vestibular implant surgery. METHODS:  Single-center case-controlled cohort study with a historic control group at a tertiary referral center. Patients were implanted with a vestibulocochlear implant, using a combination of intraoperative fluoroscopy and cone beam CT imaging. The control group consisted of five patients who were previously implanted with the former implant prototype, without the use of intraoperative imaging. Electrode positioning was analyzed postoperatively with a high-resolution CT scan using 3D slicer software. The result was defined as accurate if the electrode position was within 1.5 mm of the center of the ampulla. RESULTS: With the new imaging protocol, all electrodes could be positioned within a 1.5 mm range of the center of the ampulla. The accuracy was significantly higher in the study group with intraoperative imaging (21/21 electrodes) compared to the control group without intraoperative imaging (10/15 electrodes), (p = 0.008). CONCLUSION:  The combined use of intraoperative fluoroscopy and CT imaging during vestibular implantation can improve the accuracy of electrode positioning. This might lead to better vestibular implant performance.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Humanos , Fluoroscopía/métodos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Estudios de Casos y Controles , Tomografía Computarizada de Haz Cónico/métodos , Electrodos Implantados , Adulto , Tomografía Computarizada por Rayos X/métodos , Cirugía Asistida por Computador/métodos
3.
Laryngoscope ; 134(5): 2349-2355, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38010817

RESUMEN

OBJECTIVES: Possible beneficial "crosstalk" during cochlear implant stimulation on otolith end organs has been hypothesized. The aim of this case-control study is to analyze the effect of electrical cochlear stimulation on the vestibule (otolith end-organ), when using a cochleo-vestibular implant, comparing vestibular stimulation (VI) and cochlear stimulation (CI). METHODS: Four patients with bilateral vestibulopathy were included. A double electrode array research implant was implanted in all cases. Dynamic Gait Index (DGI), VOR gain measured by using vestibular head impulse test (vHIT), acoustic cervical myogenic responses (cVEMP) recordings, and electrical cVEMP were used in all cases. Trans-impedance Matrix (TIM) analysis was used to evaluate the current flow from the cochlea to the vestibule. RESULTS: While patients did not have any clinical vestibular improvement with the CI stimulation alone, gait metrics of the patients revealed improvement when the vestibular electrode was stimulated. The average improvement in the DGI was 38% when the vestibular implant was activated, returning to the normal range in all cases. Our findings suggest that any current flow from the cochlear space to the otolith organs was insufficient for effective cross-stimulation. The functional results correlated with the data obtained in TIM analysis, confirming that there is no current flow from the cochlea to the vestibule. CONCLUSION: The only way to produce effective electrical otolith end-organ stimulation, demonstrated with this research implant, is by direct electrical stimulation of the otolith end organs. No effective cross-stimulation was found from cochlear electrode stimulation. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:2349-2355, 2024.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Potenciales Vestibulares Miogénicos Evocados , Vestíbulo del Laberinto , Humanos , Estudios de Casos y Controles , Potenciales Vestibulares Miogénicos Evocados/fisiología , Cóclea , Estimulación Eléctrica
5.
Artículo en Chino | MEDLINE | ID: mdl-37828894

RESUMEN

Bilateral vestibulopathy(BVP) is one of the common diseases in the vestibular nervous system, with an incidence rate of about 4%-7% in the population, which can lead to a variety of body dysfunctions. At present, there are two main treatment methods for BVP. One is vestibular rehabilitation. However, only part of BVP patients can finally benefit from vestibular rehabilitation, and most patients will remain with permanent vestibular dysfunction. Benefiting from the maturity of cochlear implant technology, European and American countries took the lead in the development of vestibular prosthesis(VP) technology to restore the vestibular function in patients with BVP. This review will focus on the development history, principles, future applications and the related research progress of VP in China.


Asunto(s)
Vestibulopatía Bilateral , Implantación Coclear , Implantes Cocleares , Vestíbulo del Laberinto , Humanos , Vestibulopatía Bilateral/terapia , China
6.
J Assoc Res Otolaryngol ; 24(4): 401-412, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37516679

RESUMEN

Patients with bilateral vestibulopathy suffer from a variety of complaints, leading to a high individual and social burden. Available treatments aim to alleviate the impact of this loss and improve compensatory strategies. Early experiments with electrical stimulation of the vestibular nerve in combination with knowledge gained by cochlear implant research, have inspired the development of a vestibular neuroprosthesis that can provide the missing vestibular input. The feasibility of this concept was first demonstrated in animals and later in humans. Currently, several research groups around the world are investigating prototype vestibular implants, in the form of vestibular implants as well as combined cochlear and vestibular implants. The aim of this review is to convey the presentations and discussions from the identically named symposium that was held during the 2021 MidWinter Meeting of the Association for Research in Otolaryngology, with researchers involved in the development of vestibular implants targeting the ampullary nerves. Substantial advancements in the development have been made. Yet, research and development processes face several challenges to improve this neuroprosthesis. These include, but are not limited to, optimization of the electrical stimulation profile, refining the surgical implantation procedure, preserving residual labyrinthine functions including hearing, as well as gaining regulatory approval and establishing a clinical care infrastructure similar to what exists for cochlear implants. It is believed by the authors that overcoming these challenges will accelerate the development and increase the impact of a clinically applicable vestibular implant.


Asunto(s)
Vestibulopatía Bilateral , Implantación Coclear , Implantes Cocleares , Vestíbulo del Laberinto , Animales , Humanos , Implantación Coclear/métodos , Vestíbulo del Laberinto/cirugía , Vestíbulo del Laberinto/fisiología , Cóclea
7.
Front Integr Neurosci ; 17: 1161860, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37265514

RESUMEN

Balance disorders are highly prevalent worldwide, causing substantial disability with high personal and socioeconomic impact. The prognosis in many of these patients is poor, and rehabilitation programs provide little help in many cases. This medical problem can be addressed using microelectronics by combining the highly successful cochlear implant experience to produce a vestibular prosthesis, using the technical advances in micro gyroscopes and micro accelerometers, which are the electronic equivalents of the semicircular canals (SCC) and the otolithic organs. Reaching this technological milestone fostered the possibility of using these electronic devices to substitute the vestibular function, mainly for visual stability and posture, in case of damage to the vestibular endorgans. The development of implantable and non-implantable devices showed diverse outcomes when considering the integrity of the vestibular pathways, the device parameters (current intensity, impedance, and waveform), and the targeted physiological function (balance and gaze). In this review, we will examine the development and testing of various prototypes of the vestibular implant (VI). The insight raised by examining the state-of-the-art vestibular prosthesis will facilitate the development of new device-development strategies and discuss the feasibility of complex combinations of implantable devices for disorders that directly affect balance and motor performance.

8.
J Neurophysiol ; 129(5): 1157-1176, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-37018758

RESUMEN

The otolith end organs inform the brain about gravitational and linear accelerations, driving the otolith-ocular reflex (OOR) to stabilize the eyes during translational motion (e.g., moving forward without rotating) and head tilt with respect to gravity. We previously characterized OOR responses of normal chinchillas to whole body tilt and translation and to prosthetic electrical stimulation targeting the utricle and saccule via electrodes implanted in otherwise normal ears. Here we extend that work to examine OOR responses to tilt and translation stimuli after unilateral intratympanic gentamicin injection and to natural/mechanical and prosthetic/electrical stimulation delivered separately or in combination to animals with bilateral vestibular hypofunction after right ear intratympanic gentamicin injection followed by surgical disruption of the left labyrinth at the time of electrode implantation. Unilateral intratympanic gentamicin injection decreased natural OOR response magnitude to about half of normal, without markedly changing OOR response direction or symmetry. Subsequent surgical disruption of the contralateral labyrinth at the time of electrode implantation surgery further decreased OOR magnitude during natural stimulation, consistent with bimodal-bilateral otolith end organ hypofunction (ototoxic on the right ear, surgical on the left ear). Delivery of pulse frequency- or pulse amplitude-modulated prosthetic/electrical stimulation targeting the left utricle and saccule in phase with whole body tilt and translation motion stimuli yielded responses closer to normal than the deficient OOR responses of those same animals in response to head tilt and translation alone.NEW & NOTEWORTHY Previous studies to expand the scope of prosthetic stimulation of the otolith end organs showed that selective stimulation of the utricle and saccule is possible. This article further defines those possibilities by characterizing a diseased animal model and subsequently studying its responses to electrical stimulation alone and in combination with mechanical motion. We show that we can partially restore responses to tilt and translation in animals with unilateral gentamicin ototoxic injury and contralateral surgical disruption.


Asunto(s)
Ototoxicidad , Vestíbulo del Laberinto , Animales , Reflejo Vestibuloocular/fisiología , Membrana Otolítica/fisiología , Chinchilla , Gentamicinas
9.
J Clin Med ; 11(19)2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-36233574

RESUMEN

(1) Background. Patients with bilateral vestibular disease (BVD) experience oscillopsia with a detriment to visual acuity (VA). This VA is driven mainly by the VOR that has two components: rotational and translational. VA can be tested by using dynamic visual acuity (DVA) on a treadmill because both systems are activated. The aim of this study is to compare VA before and after chronic electrical stimulation of the otolith organ. (2) Materials and Method. Five patients suffering from bilateral vestibular dysfunction (BVD), previously implanted with a new vestibular implant prototype, were included in this study with the aim to check VA with and without vestibular implant use (W and W/O) in static, 2 km/h and 4 km/h walking situations. DVAtreadmill was measured on a treadmill with a dynamic illegible E (DIE) test in static and dynamic conditions (while walking on the treadmill at 2 and 4 km/h). The DVA score was registered in a logarithm of the minimum angle of resolution (LogMAR) for each speed. In addition, every patient completed the oscillopsia severity questionnaire (OSQ) and video head impulse test (vHIT) before and after activation of the vestibular implant. (3) Results. The analysis shows a significant difference in OSQ scores and DVA with an improvement in dynamic conditions. Organized corrective saccades during the use of a vestibular implant with no changes in gain were also detected in the video head impulse tests (vHIT). (4) Conclusion. The vestibular implant with otolithic stimulation offers changes in the response of DVA, which makes this paper one of the first to address the possible restoration of it. It is not possible to rule out other contributing factors (presence of covert saccades, somatosensory system, …). More work seems necessary to understand the neurophysiological basis of these findings, but this implant is added as a therapeutic alternative for the improvement of oscillopsia.

10.
Biosens Bioelectron ; 214: 114521, 2022 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-35820254

RESUMEN

Balance disorders affect approximately 30% of the population throughout their lives and result in debilitating symptoms, such as spontaneous vertigo, nystagmus, and oscillopsia. The main cause of balance disorders is peripheral vestibular dysfunction, which may occur as a result of hair cell loss, neural dysfunction, or mechanical (and morphological) abnormality. The most common cause of vestibular dysfunction is arguably vestibular hair cell damage, which can result from an array of factors, such as ototoxicity, trauma, genetics, and ageing. One promising therapy is the vestibular prosthesis, which leverages the success of the cochlear implant, and endeavours to electrically integrate the primary vestibular afferents with the vestibular scene. Other translational approaches of interest include stem cell regeneration and gene therapies, which aim to restore or modify inner ear receptor function. However, both of these techniques are in their infancy and are currently undergoing further characterization and development in the laboratory, using animal models. Another promising translational avenue to treating vestibular hair cell dysfunction is the potential development of artificial biocompatible hair cell sensors, aiming to replicate functional hair cells and generate synthetic 'receptor potentials' for sensory coding of vestibular stimuli to the brain. Recently, artificial hair cell sensors have demonstrated significant promise, with improvements in their output, such as sensitivity and frequency selectivity. This article reviews the history and current state of bioelectronic devices to interface with the labyrinth, spanning the vestibular implant and artificial hair cell sensors.


Asunto(s)
Técnicas Biosensibles , Células Ciliadas Vestibulares , Animales , Terapia Genética/métodos , Células Ciliadas Vestibulares/fisiología , Modelos Animales , Sistema Vestibular
11.
Audiol Neurootol ; 27(6): 458-468, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35817001

RESUMEN

INTRODUCTION: Different eye movement analysis algorithms are used in vestibular implant research to quantify the electrically evoked vestibulo-ocular reflex (eVOR). Often, standard techniques are used as applied for quantification of the natural VOR in healthy subjects and patients with vestibular loss. However, in previous research, it was observed that the morphology of the VOR and eVOR may differ substantially. In this study, it was investigated if the analysis techniques for eVOR need to be adapted to optimize a truthful quantification of the eVOR (VOR gain, orientation of the VOR axis, asymmetry, and phase shift). METHODS: "Natural" VOR responses were obtained in six age-matched healthy subjects, and eVOR responses were obtained in eight bilateral-vestibulopathy patients fitted with a vestibular implant. Three conditions were tested: "nVOR" 1-Hz sinusoidal whole-body rotations of healthy subjects in a rotatory chair, "eVOR" 1-Hz sinusoidal electrical vestibular implant stimulation without whole-body rotations in bilateral-vestibulopathy patients, and "dVOR" 1-Hz sinusoidal whole-body rotations in bilateral-vestibulopathy patients using the chair-mounted gyroscope output to drive the electrical vestibular implant stimulation (therefore also in sync 1 Hz sinusoidal). VOR outcomes were determined from the obtained VOR responses, using three different eye movement analysis paradigms: (1) peak eye velocity detection using the raw eye traces; (2) peak eye velocity detection using full-cycle sine fitting of eye traces; (3) peak eye velocity detection using half-cycle sine fitting of eye traces. RESULTS: The type of eye movement analysis algorithm significantly influenced VOR outcomes, especially regarding the VOR gain and asymmetry of the eVOR in bilateral-vestibulopathy patients fitted with a vestibular implant. Full-cycle fitting lowered VOR gain in the eVOR condition (mean difference: 0.14 ± 0.06 95% CI, p = 0.018). Half-cycle fitting lowered VOR gain in the dVOR condition (mean difference: 0.08 ± 0.04 95% CI, p = 0.009). In the eVOR condition, half-cycle fitting was able to demonstrate the asymmetry between the excitatory and inhibitory phases of stimulation in comparison with the full-cycle fitting (mean difference: 0.19 ± 0.12 95% CI, p = 0.024). The VOR axis and phase shift did not differ significantly between eye movement analysis algorithms. In healthy subjects, no clinically significant effect of eye movement analysis algorithms on VOR outcomes was observed. CONCLUSION: For the analysis of the eVOR, the excitatory and inhibitory phases of stimulation should be analysed separately due to the inherent asymmetry of the eVOR. A half-cycle fitting method can be used as a more accurate alternative for the analysis of the full-cycle traces.


Asunto(s)
Vestibulopatía Bilateral , Vestíbulo del Laberinto , Humanos , Reflejo Vestibuloocular/fisiología , Movimientos Oculares , Prótesis e Implantes
12.
J Clin Med ; 11(4)2022 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-35207405

RESUMEN

An ongoing EU Horizon 2020 Project called BionicVEST is investigating the effect of constant electrical stimulation (ES) of the inferior vestibular nerve in patients with bilateral vestibular dysfunction (BVD). The evidence is that constant ES results in improved postural stability and gait performance, and so the question of central importance concerns how constant ES of mainly saccular afferents in these BVD patients could cause this improved performance. We suggest that the constant ES substitutes for the absent saccular neural input to the vestibular nuclei and the cerebellum in these BVD patients and indirectly via these structures to other structures, which have been of great recent interest in motor control. One target area, the anterior midline cerebellum (the uvula), has recently been targeted as a location for deep-brain stimulation in human patients to improve postural stability and gait. There are projections from midline cerebellum to basal ganglia, including the striatum, which are structures involved in the initiation of gait. It may be that the effect of this activation of peripheral saccular afferent neurons is analogous to the effect of deep-brain stimulation (DBS) by electrodes in basal ganglia acting to help alleviate the symptoms of patients with Parkinson's disease.

13.
J Neurol ; 269(10): 5229-5238, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34374862

RESUMEN

BACKGROUND: Certain cases of superior semicircular canal dehiscence or benign paroxysmal positional vertigo can be treated by plugging of the affected semicircular canal. However, the extent of the impact on vestibular function and hearing during postoperative follow-up is not known. OBJECTIVE: To evaluate the evolution of vestibular function and hearing after plugging of a semicircular canal. METHODS: Six patients underwent testing before and 1 week, 2 months, and 6 months after plugging of the superior or posterior semicircular canal. Testing included caloric irrigation test, video Head Impulse Test (vHIT), cervical and ocular Vestibular Evoked Myogenic Potentials (VEMPs) and audiometry. RESULTS: Initially, ipsilateral caloric response decreased in all patients and vHIT vestibulo-ocular reflex (VOR) gain of each ipsilateral semicircular canal decreased in 4/6 patients. In 4/6 patients, postoperative caloric response recovered to > 60% of the preoperative value. In 5/6 patients, vHIT VOR gain was restored to > 85% of the preoperative value for both ipsilateral non-plugged semicircular canals. In the plugged semicircular canal, this gain decreased in 4/5 patients and recovered to > 50% of the preoperative value. Four patients preserved cervical and ocular VEMP responses. Bone conduction hearing deteriorated in 3/6 patients, but recovered within 6 months postoperatively, although one patient had a persistent loss of 15 dB at 8 kHz. CONCLUSION: Plugging of a semicircular canal can affect both vestibular function and hearing. After initial deterioration, most patients show recovery during follow-up. However, a vestibular function loss or high-frequency hearing loss can persist. This stresses the importance of adequate counseling of patients considering plugging of a semicircular canal.


Asunto(s)
Canales Semicirculares , Potenciales Vestibulares Miogénicos Evocados , Audiometría , Prueba de Impulso Cefálico , Humanos , Reflejo Vestibuloocular/fisiología , Canales Semicirculares/fisiología
14.
J Neurol ; 269(10): 5249-5257, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34894283

RESUMEN

OBJECTIVES: The aim of this study was to explore expectations of patients with bilateral vestibulopathy regarding vestibular implant treatment. This could advance the definition of recommendations for future core outcome sets of vestibular implantation and help to determine on which characteristics of bilateral vestibulopathy future vestibular implant research should focus. METHODS: Semi-structured interviews were conducted with 50 patients diagnosed with bilateral vestibulopathy at Maastricht UMC + . Interviews followed a semi-structured interview guide and were recorded and transcribed. Transcripts were analyzed thematically by two independent researchers. A consensus meeting took place to produce a joint interpretation for greater dimensionality and to confirm key themes. RESULTS: Overall, patient expectations centralized around three key themes: (physical) symptom reduction, functions and activities, and quality of life. These themes appeared to be interrelated. Patient expectations focused on the activity walking (in a straight line), reducing the symptom oscillopsia and being able to live the life they had before bilateral vestibulopathy developed. In general, patients indicated to be satisfied with small improvements. CONCLUSION: This study demonstrated that patient expectations regarding a vestibular implant focus on three key themes: symptom reduction, functions and activities, and quality of life. These themes closely match the functional improvements shown in recent vestibular implantation research. The results of this study provide a clear guideline from the patient perspective on which characteristics of bilateral vestibulopathy, future vestibular implant research should focus. TRIAL REGISTRATION: NL52768.068.15/METC.


Asunto(s)
Vestibulopatía Bilateral , Vestíbulo del Laberinto , Humanos , Calidad de Vida , Trastornos de la Visión
15.
Front Neurol ; 12: 663803, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34113311

RESUMEN

Objective: Several studies have demonstrated the possibility to obtain vestibular potentials elicited with electrical stimulation from cochlear and vestibular implants. The objective of this study is to analyze the vestibular-evoked myogenic potentials (VEMPs) obtained from patients implanted with cochlear and vestibulo-cochlear implant. Material and Methods: We compared two groups: in the first group, four cochlear implant (CI) recipients with present acoustic cVEMPs before CI surgery were included. In the second group, three patients with bilaterally absent cVEMPs and bilateral vestibular dysfunction were selected. The latter group received a unilateral cochleo-vestibular implant. We analyze the electrically elicited cVEMPs in all patients after stimulation with cochlear and vestibular electrode array stimulation. Results: We present the results obtained post-operatively in both groups. All patients (100%) with direct electrical vestibular stimulation via the vestibular electrode array had present cVEMPs. The P1 and N1 latencies were 11.33-13.6 ms and 18.3-21 ms, respectively. In CI patients, electrical cVEMPs were present only in one of the four subjects (25%) with cochlear implant ("cross") stimulation, and P1 and N1 latencies were 9.67 and 16.33, respectively. In these patients, the responses present shorter latencies than those observed acoustically. Conclusions: Electrically evoked cVEMPs can be present after cochlear and vestibular stimulation and suggest stimulation of vestibular elements, although clinical effect must be further studied.

16.
J Neurol ; 267(Suppl 1): 241-255, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33030608

RESUMEN

OBJECTIVE: To optimize the current diagnostic and treatment procedures for patients with bilateral vestibulopathy (BV), this study aimed to determine the complete spectrum of symptoms associated with BV. METHOD: A prospective mixed-method study design was used. Qualitative data were collected by performing semi-structured interviews about symptoms, context, and behavior. The interviews were recorded and transcribed until no new information was obtained. Transcriptions were analyzed in consensus by two independent researchers. In comparison to the qualitative results, quantitative data were collected using the Dizziness Handicap Inventory (DHI), Hospital Anxiety and Depression Scale (HADS) and a health-related quality of life questionnaire (EQ-5D-5L). RESULTS: Eighteen interviews were transcribed. Reported symptoms were divided into fourteen physical symptoms, four cognitive symptoms, and six emotions. Symptoms increased in many situations, such as darkness (100%), uneven ground (61%), cycling (94%) or driving a car (56%). These symptoms associated with BV often resulted in behavioral changes: activities were performed more slowly, with greater attention, or were avoided. The DHI showed a mean score of severe handicap (54.67). The HADS questionnaire showed on average normal results (anxiety = 7.67, depression = 6.22). The EQ-5D-5L demonstrated a mean index value of 0.680, which is lower compared to the Dutch age-adjusted reference 0.839 (60-70 years). CONCLUSION: BV frequently leads to physical, cognitive, and emotional complaints, which often results in a diminished quality of life. Importantly, this wide range of symptoms is currently underrated in literature and should be taken into consideration during the development of candidacy criteria and/or outcome measures for therapeutic interventions such as the vestibular implant.


Asunto(s)
Vestibulopatía Bilateral , Adolescente , Adulto , Anciano , Niño , Preescolar , Mareo , Humanos , Lactante , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida , Vértigo , Adulto Joven
17.
Artículo en Chino | MEDLINE | ID: mdl-32791603

RESUMEN

Vestibular dysfunction can seriously affect patients' daily life and work. There is an urgent need for new methods to treat vestibular dysfunction. As awareness of these diseases increases, efforts are being made to improve vestibular function through a number of vestibular assistant systems. As far as current development is concerned, vestibular assistant system mainly focuses on two fields: external prosthesis and vestibular implant. This review shows the current status and future development trend of the vestibular assistant system.


Asunto(s)
Enfermedades Vestibulares , Vestíbulo del Laberinto , Humanos , Prótesis e Implantes
18.
J Neurol ; 267(Suppl 1): 273-284, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32778921

RESUMEN

BACKGROUND AND PURPOSE: Vestibular implants seem to be a promising treatment for patients suffering from severe bilateral vestibulopathy. To optimize outcomes, we need to investigate how, and to which extent, the different vestibular pathways are activated. Here we characterized the simultaneous responses to electrical stimuli of three different vestibular pathways. METHODS: Three vestibular implant recipients were included. First, activation thresholds and amplitude growth functions of electrically evoked vestibulo-ocular reflexes (eVOR), cervical myogenic potentials (ecVEMPs) and vestibular percepts (vestibulo-thalamo-cortical, VTC) were recorded upon stimulation with single, biphasic current pulses (200 µs/phase) delivered through five different vestibular electrodes. Latencies of eVOR and ecVEMPs were also characterized. Then we compared the amplitude growth functions of the three pathways using different stimulation profiles (1-pulse, 200 µs/phase; 1-pulse, 50 µs/phase; 4-pulses, 50 µs/phase, 1600 pulses-per-second) in one patient (two electrodes). RESULTS: The median latencies of the eVOR and ecVEMPs were 8 ms (8-9 ms) and 10.2 ms (9.6-11.8 ms), respectively. While the amplitude of eVOR and ecVEMP responses increased with increasing stimulation current, the VTC pathway showed a different, step-like behavior. In this study, the 200 µs/phase paradigm appeared to give the best balance to enhance responses at lower stimulation currents. CONCLUSIONS: This study is a first attempt to evaluate the simultaneous activation of different vestibular pathways. However, this issue deserves further and more detailed investigation to determine the actual possibility of selective stimulation of a given pathway, as well as the functional impact of the contribution of each pathway to the overall rehabilitation process.


Asunto(s)
Vestibulopatía Bilateral , Vestíbulo del Laberinto , Estimulación Eléctrica , Humanos , Reflejo Vestibuloocular , Canales Semicirculares
19.
J Vestib Res ; 30(3): 213-223, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32651339

RESUMEN

This opinion statement proposes a set of candidacy criteria for vestibular implantation of adult patients with bilateral vestibulopathy (BVP) in a research setting. The criteria include disabling chronic symptoms like postural imbalance, unsteadiness of gait and/or head movement-induced oscillopsia, combined with objective signs of reduced or absent vestibular function in both ears. These signs include abnormal test results recorded during head impulses (video head impulse test or scleral coil technique), bithermal caloric testing and rotatory chair testing (sinusoidal stimulation of 0.1 Hz). Vestibular implant (VI) implantation criteria are not the same as diagnostic criteria for bilateral vestibulopathy. The major difference between VI-implantation criteria and the approved diagnostic criteria for BVP are that all included vestibular tests of semicircular canal function (head impulse test, caloric test, and rotatory chair test) need to show significant impairments of vestibular function in the implantation criteria. For this, a two-step paradigm was developed. First, at least one of the vestibular tests needs to fulfill stringent criteria, close to those for BVP. If this is applicable, then the other vestibular tests have to fulfill a second set of criteria which are less stringent than the original criteria for BVP. If the VI-implantation is intended to excite the utricle and/or saccule (otolith stimulation), responses to cervical and ocular vestibular evoked myogenic potentials must be absent in addition to the above mentioned abnormalities of semicircular canal function. Finally, requirements for safe and potentially effective stimulation should be met, including implanting patients with BVP of peripheral origin only, and assessing possible medical and psychiatric contraindications.


Asunto(s)
Vestibulopatía Bilateral/diagnóstico , Vestibulopatía Bilateral/cirugía , Investigación Biomédica/normas , Implantes Cocleares/normas , Sociedades Médicas/normas , Pruebas de Función Vestibular/normas , Vestibulopatía Bilateral/fisiopatología , Investigación Biomédica/métodos , Pruebas Calóricas/métodos , Pruebas Calóricas/normas , Prueba de Impulso Cefálico/métodos , Prueba de Impulso Cefálico/normas , Humanos , Pruebas de Función Vestibular/métodos , Vestíbulo del Laberinto/fisiopatología , Vestíbulo del Laberinto/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...